Quick Reference Guide TriStar For SP3202VSPND, go to “Set Pump Address” Default Speeds = = = = SPEED 1 SPEED 2 SPEED 3 SPEED 4 1000 rpm 1750 rpm 2500 rpm 3250 rpm * QUICK CLEAN 3450 rpm Total HP 1.85/ 230V Single Phase 60Hz *Max allowed speed of 60mins Configuration Menu MENU until appears, then hold down < & until you see CHECK SYSTEM TIMERS ACTIVE SPEED 1 + are changed using the + SPEED 2 SPEED 3 to edit items, flashing items + Press to advance, < to back up < STOP/RESUME < < Press < Push MENU QUICK CLEAN SPEED 4 - or - Timers Menu - Stand Alone until appears, then press - to view schedule days, use / - to modify, then < Repeat this process until all desired timers are set MENU to exit, and then + To save changes, press then press / - to modify start time, then + Push + use / to save to adjust end < use + + Next set Timer speed to advance < to change timer name, then press < Push to modify < use + MENU < Push to review Quick Reference Guide - Check System Connecting TriStar for Relay Control 1. Power pump through filter relay: FILTER Relay 240VAC from breaker DIGITAL INPUT SW200 ON B COM I COM OVRD STEP 3 STEP 2 +12V A STEP 1 12 345 RS485 L2 L1 2. Wire low voltage circuits for each relay with 300V rated conductors 3. Verify pump is configured for Relay Control: Locate and unlock Configuration Menu (instructions on front) MENU then + < Press if shows “Standalone” press + until Press to save any changes 4. Set speeds under the ‘Timer’s Menu’ Connecting TriStar to Hayward Automation*VSPND Model ONLY* Consult controller manual for compatibility AND select appropriate pump address 1. Connect with shielded 300V communciation wire (utilizing a twisted pair) 2. Set dip switches according to automation system configuration DIGITAL INPUT SW200 RS485 +12V A B COM 2 3 To take a closer look or see other Hayward products please go to: 1 2 3 4 OVRD #5 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON I COM #4 OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON STEP 3 #3 OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON STEP 2 #2 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON ON #1 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 12 345 Pool Filter Aux 1 / Spa Filter Aux 2 Aux 3 Aux 4 Aux 5 Aux 6 Aux 7 Aux 8 Aux 9 Aux 10 Aux 11 Aux 12 Aux 13 Aux 14 Lights Button STEP 1 PUMP ADDRESS Hayward Controller (RS485) www.hayward.com or call 1-800-432-8387 QRG3201VSP (Rev. A)