Preview only show first 10 pages with watermark. For full document please download

Tropical Concord Manual

   EMBED


Share

Transcript

® R9 Issue 3 1/00 PRODUCT MANUAL ▼ TROPICAL CONCORD CONTENTS 1. Introduction ....................................................... 2 2. User Instructions ................................................ 2 3. Specification ...................................................... 3 4. Installation ......................................................... 4 5. Maintenance ...................................................... 5 6. Fault Finding ..................................................... 6 7. Exploded View – Vertical ................................. 7 8. Spare Parts List – Vertical ................................. 8 9. Wiring Diagram..................................................9 1 ▼ TROPICAL CONCORD ® 1. INTRODUCTION 2. USER INSTRUCTIONS The Tropical Concord is a range of beer coolers designed to be sited either remote or under the counter. They are designed to operate in high ambient conditions and are ruggedly constructed to withstand tropical conditions. A recirculation pump provides both constant agitation of the water bath and a flow of recirculating chilled water around the python. The recirculating water keeps the beer in the python cold. The cooler has been designed with simplicity and reliability in mind. ❖ Operation of the cooler To maintain the safe operation and reliability of the cooler during normal use, please observe the following points:The cooler is designed to run continuously. During normal use it should only be switched off when cooling will not be required for a period longer than 24 hours. The cooler should be restarted at least 8 hours (dependant on model) before it is to be used. Do not spill or let liquids drip on the cooler – if liquids do spill onto the unit, electrically isolate before wiping the spillage’s up. Do not place items close to the cooler as this can reduce the airflow to and reliability of the cooler. Do not place items on top of the cooler as this may cause damage to the agitator/pump assemblies. Do not move the unit once full of water. Do not block the water tank overflow – any condensation generated by the cooler must be allowed to run away. Note: In the event of malfunction switch off and electrically unplug the cooler. Always use a qualified Service Engineer to repair the unit – there are no user serviceable components. A mains on light is provided on the front of the cooler to indicate that an electrical supply is present. Nominally the cooler will produce 16kg of ice. A full Product data sheet is available detailing the technical specification and range of cooler models. The Tropical Concords have the part number range 48 117G xxx. This product manual is applicable for both the vertical and horizontal versions. ❖ Cleaning routine Beer coils can be internally cleaned as part of the regular draught beer system cleaning as follows:1. Purge the beer lines with clean, cool water. 2. Add a chlorinated alkaline cleaning solution, diluted with the correct amount of water, to the system. 3. Allow to stand in the pipes for the time specified by the cleaning solution manufacturer – usually 30 minutes. 4. Flush the system with clean, cool water to remove all traces of the cleaning solution. 5. Refill the system with beer. The outside of the cooler can be cleaned using a mild non-foaming aerosol cleaner sprayed onto a dry cloth and wiped over the surface of the cooler. Electrically unplug the unit whilst cleaning. 2 ▼ TROPICAL CONCORD ® 3. SPECIFICATION For a full and detailed specification refer to the product data sheets. PERFORMANCE ❖ Ice bank weight 14kg (nominal) DIMENSIONS ❖ ❖ ❖ ❖ ❖ Vertical Vertical No 6 pump No 2 pump Width 440mm 440mm Depth 530mm 530mm Height 780mm 715mm Weight 85kg (operating) Water bath capacity: 23 litres ELECTRICAL See rating plate located on the cooler (or product data sheets) for the electrical rating of this cooler. 3 ▼ TROPICAL CONCORD ® 4. INSTALLATION 7. Electrically isolate the cooler. Connect the beer inlet and outlet lines and python water recirculation lines (if used) – check for leaks from each joint before completing the insulation. The python insulation should be carefully finished to ensure that all cold surfaces are fully insulated and to prevent air from entering beneath the insulated surface. Note: The dispense performance is dependant on well constructed and well insulated pythons. 8. Sanitise the unit – see User instructions. 9. Electrically switch the unit on. 10. The system is now ready for operation but will not give best results until the ice bank is fully formed and the python temperatures are stabilised. Installation to be carried out by a suitably trained person only. Compliance with local Bylaws and Codes of Practise must be ensured. To ensure trouble free operation it is essential that the unit is installed correctly and sanitised prior to use. 1. The cooler should be sited on a firm level surface, in a well ventilated position, and at a maximum distance of 2 metres from an electrical supply. To ensure efficient and reliable operation of the refrigeration system allow 75mm clearance around the unit and that there is an un-impeded flow of air to and from the condenser grilles Allow for future access to the lid and service panels. 2. If not already fitted, fit the appropriate electrical pug to the service cord – consult local Electrical legislation for correct method of installation. WARNING – THIS APPLIANCE MUST BE EARTHED. Do not connect the cooler at this point. Always connect the cooler to an appropriately rated electrical fuse or circuit breaker. 3. Remove/turn the filler cap or lid inspection panel (as appropriate) and fill the bath with cool, clean, water until the water flows from the overflow. Do not use de-ionised water or add any substance to the water. Do not leave hose pipes unattended whilst filling the water bath – the overflow will not remove water quickly enough to prevent water from spilling onto electrical components. Once filled with water do not move the unit. 4. If a recirculation pump is fitted, block the outlet. 5. Ensure that all covers and access panels are screwed in place. 6. Ensure that the cooler is electrically safe. The cooler may now be electrically switched on to allow it to cool whilst the rest of the installation is completed. The cooler will displace water through the overflow as it forms its ice. 4 ▼ TROPICAL CONCORD ® 5. MAINTENANCE Maintenance to be carried out by a suitably trained person only. Compliance with local Bylaws and Codes of Practise must be ensured. The cooler requires occasional checking and cleaning as follows – 1. Check that the water level in the tank is up to the overflow. Remove the inspection/fill cover and observe the water level. 2. Check that the airflow to the cooler is unimpeded and clean the condenser fins. To clean the fins – electrically isolate the unit, use a soft bristle brush to clean the condenser fins of dirt, dust etc.. Take care not to damage the fins during cleaning. 3. Check the condition of the python insulation and that the pump is circulating water. 4. At regular intervals to be determined by the user and/or owner of the cooler, check for electrical safety. If any maintenance/servicing is required, refer to the fault finding chart, wiring diagram and exploded drawings contained in this manual and always ensure that the following are observed – 5. When replacing components always use IMI Cornelius approved spare parts. Failure to do so will invalidate the coolers approvals. 6. Always electrically isolate the cooler before removing covers or carrying out any work. 7. After working on the cooler ensure that the unit is left electrically safe and that all covers and cover fixings are refitted. 8. If replacing a condenser fan motor always fit a new fan blade. 9. If removing a recirculation pump do not invert the assembly as water will run into the motor. Do not knock or jar the assembly as this may damage the bearings. 10. The drier must be replaced each time the refrigeration system is opened. 11. Always replace seals, screws covers etc. after servicing the cooler. 5 ▼ TROPICAL CONCORD ® 6. FAULT FINDING Problem Possible Fault Possible Cause Action Beer frozen in coil Ice bank too large Faulty ice bank control Poorly positioned ice sensor Replace Reposition Beer warm Reduced ice weight or long time to form ice Faulty ice bank control Fuse blown No electrical supply Replace Check and replace Check Refrigeration system failure Poor condenser cooling Replace base unit Pump not connected Pump failed Pump or python blocked Connect pump Replace pump Check for kinks in pipes. Clear out debris from lines Insufficient water in tank Top up water level Beer too warm into cooler Keg badly positioned Condenser airflow warming keg Reposition keg Reposition keg Poor agitation of water onto coils Motor failure Replace motor/pump Pump impeller failed Excessive algae growth in bath Replace Clean bath and coil outer surface Poor python insulation Re-insulate Poor python routing – heat pick-up Re-route Poor airflow to condenser Re-site cooler Ice bank formed when not required Switch to winter mode No water recirculation Poor system installation Beer too cold Summer mode selected Check clearance around cooler and fan motor operation. Check condenser and clean if necessary Note: Refrigeration system failure could be – Start device for compressor failed, over temperature device in compressor tripped, open circuit on compressor motor windings, refrigerant gas leak, capillary tube blockage etc. These faults are best diagnosed and repaired off site in a workshop environment. 6 ▼ TROPICAL CONCORD ® ▼ TROPICAL TROPICAL CONCORD CONCORD ® 7. EXPLODED VIEW –VERTICAL 1 2 3 11 10 4 5 6 9 8 7 7 ® 8. SPARE PARTS LIST – VERTICAL ITEM No. PART No. DESCRIPTION 1. 99 1174 004 99 2ZU232A Pump No. 2 (230V, 50/60Hz) Pump No. 6 (230V, 50/60Hz) 2. 03 1BFO 41A 03 1BF0 33A No. 62 propeller 44.5mm dia (No. 2 pump) No. 62 propeller -62mm dia (No. 6 pump) 3. 58 1170 010 58 1170 012 Coil Assy. Prod 1P PLN OD7.9 SS Coil Assy. Prod 2P PLN OD7.9 SS 4. 2EL412A Neon Red 5. 99 0420 072 Start Relay (230V, 50/60Hz) 6. 99 0420 059 Start Capacitor (230V, 50/60Hz) 7. 85 6012 045 10" Alu Fan Blade C/W 8. 99 1174 011 Mod to Fan Motor 9. 44 0000 209 Comp Set SC18G HST 10. 58 1174 007 Thermostat Superspot 11. . 58 1174 008 58 1174 016 58 1174 018 Mod’d Mains Lead Mod’d Mains Cable Mod’d Mains Cable Euro 8 ▼ TROPICAL TROPICAL CONCORD CONCORD 9. WIRING DIAGRAM WH BR BL GY = = = = White Brown (Live) Blue (Neutral) Green/Yellow (Earth) 9 ▼ TROPICAL CONCORD ® Please complete fully all parts 1-4 1. ▼ ORDER FORM/ PROFORMA INVOICE ® OFFICE USE ONLY Customer Order Number: Cornelius Account No. Name: --------------------------------------------------------------- Company Name: ---------------------------------------------------------Day Time Phone Number: ---------------------------------------- Fax Number: --------------------------------------------------------------2. Invoice Address: -------------------------------------------------- Delivery Address: ------------------------------------------------- ----------------------------------------------------------------------- ----------------------------------------------------------------------- ---------------------------------------- Post Code: ----------------- ---------------------------------------- Post Code: ----------------- Special Instructions: ------------------------------------------------------------------------------------------------------------------------------OFFICE USE ONLY 3. Part Number Qty Required Price per Unit Part Description Total Cost OFFICE USE ONLY Acknowledgement No. Cheque Clearance Date Cost Due Date Delivery Request Date VAT @ 17.5% Total Order Value IMI Cornelius standard terms & conditions of sale apply. 4. Please indicate payment method: Account Cheque Postal Order Access/Visa Cheques or Postal Orders should be made payable to IMI Cornelius (UK) Ltd. For Access or Visa Payments, please indicate your card number. Expiry Date: --------------------------Signature: ------------------------------------------------ Name: -------------------------------------------------- Date: -------------------Address: -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Post Code: -----------------------------------Please return to: IMI CORNELIUS (UK) LTD Rawson Spring Way Riverdale Industrial Estate Sheffield S6 1PG TEL: 0114 285 5886 ORDER 8.30 am ☎ HOTLINE 5.15 pm FAX: 0114 232 1070 ▼ ® IMI CORNELIUS (UK) LTD ® Tything Road Alcester Warwickshire England B49 6EU Telephone: 01789 763101 Facsimile: 01789 400595