TRS-73120G
1
***********************************************************************************************************************************************************************
TRS-73120G/TRS-73120CG/TRS-73120TG/TRS-73120CTG/ RS-73120FG/TRS-73120CFG 3.3V / 1550 nm / 1.25 Gbps RoHS Compliant Optical Single-Mode Transceiver **********************************************************************************************************************************************************************
FEATURES
DESCRIPTION
l l l l l l l l l l l l l l l
The TRS-73120G series single mode transceivers is low power, high performance module for bi-directional serial optical data communications such Gigabit Ethernet and Fibre Channel. This module is designed for single mode fiber and operates at a nominal wavelength of 1550 nm. A guaranteed minimum optical link budget of 32 dB is offered which can correspond to a link distance of over 120 km (assuming worst case fiber loss of 0.25 dB/km). The transmitter section uses a multiple quantum well laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs Avalanche photodetector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. A PECL logic interface simplifies interface to external circuitry.
Duplex SC Single Mode Transceiver: TRS-73120G Duplex ST Single Mode Transceiver: TRS-73120TG Duplex FC Single Mode Transceiver: TRS-73120FG Compliant with IEEE-802.3z Gigabit Ethernet 1550 nm DFB LD Transmitter High Sensitivity APD Receiver 32 dB Power Budget At Least 0 to 70oC Operating Industry Standard 1 x 9 Footprint Single +3.3V Power Supply RoHS Compliant LVPECL Signal Detect Output: TRS-73120G LVTTL Signal Detect Output: TRS-73120CG Wave Solderable and Aqueous Washable Class 1 Laser International Safety Standard IEC 60825 Compliant
LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC 60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug.
APPLICATIONS l Switch to Switch Interface l High Speed Interface for File Servers l High Performance Desktops
ORDER INFORMATION P/No. TRS-73120G
Bit Rate (Mb/s) 1250
IEEE 802.3z EZX
Package Distance Wavelength Voltage (km) (nm) (V) 120 1550 DFB 3.3 1X9 SC/ST/FC
Temp. (oC) 0 to 70
TX Power RX Sens. RoHS (dBm) (dBm) Compliant 5 to 0 -32 Yes
Note: TRS-XXXXXFG for FC duplex transceiver, TRS-XXXXXTG for ST duplex transceiver, TRS-XXXXX-EMG for SC duplex transceiver with extended EMI shielding, TRS-XXXXXCXG for transceiver with TTL signal detection output.
Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Soldering Temperature Power Supply Voltage Input Voltage Output Current
Symbol Tstg Topr --Vcc --Iout
Min -40 0 0 GND
Max 85 70 260 4.5 Vcc
Units o C o C o C V V
0
30
mA
Min 3.13 0
Typ 3.3
Max 3.47 70 1300 280
Notes
10 seconds on leads only
Recommended Operating Conditions Parameter Power Supply Voltage Operating Temperature Data Rate Power Supply Current
Symbol Vcc Topr
1250 Icc
Units V o C Mb/s mA
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
10/1/2005 V3.0
Optoway
TRS-73120G
2
**********************************************************************************************************************************************************************
Transmitter Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3. 47V) Parameter Optical Optical Transmit Power Output Center Wavelength Output Spectrum Width Side Mode Suppression Ratio Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Relative Intensity Noise Total Jitter Electrical Data Input Current – Low Data Input Current – High Differential Input Voltage Data Input Voltage – Low Data Input Voltage -- High
Symbol
Min
Typ
Max
Units
Notes
Po 0 1500 λ --∆λ SMSR 30 ER 9 Compliant with IEEE 802.3z tr tf RIN TJ
--1550 ---
5 1580 1
1
---
---
dBm nm nm dB dB
0.26 0.26 -120 0.227
ns ns dB/Hz ns
IIL IIH VIH - VIL V IL - VCC V IH - VCC
-350 350 300 -2.0 -1.1
-1.58 -0.74
µA µA mV V V
-20 dB Width
20% to 80% Values 20% to 80% Values 2
3 3
Notes: 1. Output power is power coupled into a 9/125 µm single mode fiber. 2. Measured with a 27-1 PRBS. 3. These inputs are compatible with 10K, 10KH and 100K ECL and LVPECL inputs.
Receiver Specifications (0oC < Topr < 70oC, 3.13 V < Vcc < 3.47V) Parameter Optical Sensitivity Maximum Input Power Signal Detect -- Asserted Signal Detect -- Deasserted Signal detect -- Hysteresis Wavelength of Operation Electrical Data Output Voltage – Low Data Output Voltage – High Signal Detect Output Voltage -- Low Signal Detect Output Voltage -- High Signal Detect Output Voltage -- Low Signal Detect Output Voltage -- High
Symbol
Min
Typ
Max
Units
Notes
--Pin Pa Pd
---9 ---43 1.0 1100
---
-32 ---32 ---
dBm dBm dBm dBm dB nm
1
VOL - V CC VOH - V CC VOL - V CC VOH - V CC VSDL VSDH
-2.0 -1.1 -2.0 -1.1
---------
1600 -1.58 -0.74 -1.58 -0.74 0.8
2.0
V V V V V V
Transition: low to high Transition: high to low
3 3 TRS-73120G TRS-73120CG
Notes: 1. Minimum sensitivity and saturation levels at BER=1E-12 for a 2 7-1 PRBS at ER= 9 dB. 2. These outputs are compatible with 10K, 10KH and 100K ECL and PECL outputs.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
10/1/2005 V3.0
Optoway
TRS-73120G
3
**********************************************************************************************************************************************************************
CONNECTION DIAGRAM Receiver Signal Ground 1 (Rx GND) Receiver Data Out 2 (RD+) Receiver Data Out Bar 3 (RD−) Signal Detect 4 (SD) Receiver Power Supply 5 (Rx Vcc) Transmitter Power Supply 6 (Tx Vcc) Transmitter Data In Bar 7 (TD−) Transmitter Data In 8 (TD+) Transmitter Signal Ground 9 (Tx GND)
PIN 1 2 3 4 5 6 7 8 9
Symbol Rx GND RD+ RD− SD Rx Vcc Tx Vcc TD− TD+ Tx GND
N/C
TOP VIEW
N/C
Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal +3.3V dc power for the receiver section +3.3V dc power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this plan to the transmitter ground plane
RECOMMENDED CIRCUIT SCHEMATIC Transceiver
LD Driver
SerDes IC TX GND
9
TD+
8
VCC 3.3V
TD+
0.1uF
Z=50R
100R
LVPECL TD-
7
TD0.1uF
Z=50R
TX Vcc
1uH
6
Vcc 3.3V
10nF
10uF
VCC 3.3V
1uH R1
RX Vcc
5
SD Level
10nF
10uF
R2 VCC 3.3V
SD
4
RD0.1uF POST
3
RDZ=50R R7
180R
LVPECL
Amp RD+ 0.1uF
2
RD+ Z=50R
180R RX GND
1 CDR or PHY DEVICE
For TTL SD Level, R1=R2=N.C., R7=100 ohm For PECL SD Level, R1=130 ohm, R2=82 ohm, R7=100 ohm The split-load terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc and Tx Vcc. A GND plane under the module is required for good EMI and sensitivity performance.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
10/1/2005 V3.0
Optoway
TRS-73120G
4
**********************************************************************************************************************************************************************
PACKAGE DIAGRAM Units in mm
1) SC Type With Extended Shielding
TX OPTIC AL
RX OPTIC AL
TRS-73120-EMG / TRS-73120C-EMG 2) ST Type
TX OPTIC AL
RX OPTIC AL
TRS-73120TG / TRS-73120CTG
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
10/1/2005 V3.0
Optoway
TRS-73120G
5
**********************************************************************************************************************************************************************
3) FC Type 12.7
TX OPTICAL
RX OPTICAL
2.54*8 20.32
O1.3
20.32
13.7
10
10.18
0.75
5.97
13.9
25.4
34.5MAX
TRS-73120FG / TRS-73120CFG Note: Specifications subject to change without notice.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
10/1/2005 V3.0