TRSL-3380WG / TRSL-3380AWG / TRSL-3380CWG / TRSL-3380ACWG (RoHS Compliant) 3.3V / 1550 nm / 155 Mbps SFF LC 2X10 SINGLE-MODE TRANSCEIVER **********************************************************************************************************************************************************************
FEATURES
DESCRIPTION
l l l l l l l
The TRSL-3380WG series single mode transceivers is small form factor, low power, high performance module for bi-directional serial optical data communications such as SONET OC-3 LR-2 / SDH STM-1 (L-1.2) and Fast Ethernet. This module is designed for single mode fiber and operates at a nominal wavelength of 1550 nm. A guaranteed minimum optical link budget of 29 dB is offered which can correspond to a link distance of over 80 km (assuming worst case fiber loss of 0.25 dB/km). The transmitter section uses a multiple quantum well laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. A PECL logic interface simplifies interface to external circuitry.
Duplex LC Single Mode Transceiver SONET OC-3 LR-2 / SDH STM-1 (L-1.2) Compliant Small Form Factor, RJ-45 size, 2X10 pin Package 1550 nm DFB LD Transmitter 29 dB Link Power Budget at Least Distance up to 80 km Analog Monitor Function -- Transmitter Laser Bias Current -- Transmitter Laser Optical Power Monitor -- Receiver Photo Detector Current l LVPECL Signal Input / Output l LVTTL Transmitter Disable Input l LVPECL Signal Detect Output: TRSL-3380WG l LVTTL Signal Detect Output: TRSL-3380CWG l Single +3.3 V Power Supply l 0 to 70oC Operating: TRSL-3380WG l -40 to 85oC Operating: TRSL-3380AWG l Wave Solderable and Aqueous Washable l Class 1 Laser International Safety Standard IEC 60825 Compliant
APPLICATIONS l ATM 155 Mbps Links l SONET/SDH Equipment Interconnect l Fast Ethernet 100 Mb/s Links
LASER SAFETY This single mode transceiver is a Class 1 laser product. It complies with IEC 60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug.
ORDER INFORMATION P/No. TRSL-3380WG TRSL-3380AWG
Bit Rate (Mb/s) 125 / 155 125 / 155
SDH /SONET LR-2/L-1.2 LR-2/L-1.2
Distance (km) 80 80
Wavelength Package (nm) 1550 DFB 2X10 LC 1550 DFB 2X10 LC
Temp. TX Power RX Sens. RoHS (oC) (dBm) (dBm) Compliant 0 to 70 0 to -5 -34 Yes -40 to 85 0 to -5 -34 Yes
Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature
Symbol Tstg Topr
Soldering Temperature Power Supply Voltage Input Voltage
--Vcc ---
Output Current
Iout
Min -40 0 -20
Units o C o C
0 GND
Max 85 70 85 260 4.5 Vcc
0
30
mA
Min 3.13 0 -20
Typ 3.3
Max 3.47 70 85 200 280
o
C V V
Notes TRSL-3380WG TRSL-3380AWG 10 seconds on leads only
Recommended Operating Conditions Parameter Power Supply Voltage Operating Temperature
Symbol Vcc Topr
Data Rate Power Supply Current
Icc
125 / 155 200
Units / Notes V o C / TRSL-3380WG o C / TRSL-3380AWG Mb/s mA
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
12/1/2005 V2.0
Optoway
TRSL-3380WG
2
**********************************************************************************************************************************************************************
Transmitter Specifications (0 oC < Topr < 70 oC, 3.13V < Vcc < 3.47V) Parameter Optical Optical Transmit Power Output Center Wavelength Output Spectrum Width Side Mode Suppression Ratio Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Relative Intensity Noise Total Jitter Electrical Data Input Current – Low Data Input Current – High Differential Input Voltage Data Input Voltage – Low Data Input Voltage -- High Disable Input Voltage -- Low Disable Input Voltage -- High Shut Off Time for TxDis
Symbol
Min
Typ
Max
Units
Notes
Po -5 --0 dBm 1480 1550 1580 nm λ ----1 nm ∆λ SMSR 30 dB ER 10 ----dB Compliant with Bellcore GR-253-CORE and ITU recommendation G.957 tr 2 ns tf 2 ns RIN -116 dB/Hz TJ 1 ns IIL IIH VIH - VIL V IL - VCC V IH - VCC VTDIS,L VTDIS,H tDIS
-350 350 300 -2.0 -1.1 0 Vcc – 1.3
-1.58 -0.74 0.5 Vcc 1
µA µA mV V V V V ms
1 -20 dB Width
10% to 90% Values 10% to 90% Values 2
3 3 TX Output Enabled TX Ouput Disabled
Notes: 1. Output power is power coupled into a 9/125 µm single mode fiber. 2. Measured with a 223-1 PRBS with 72 ones and 72 zeros. 3. These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs.
Receiver Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V) Parameter Optical Sensitivity Maximum Input Power Signal Detect -- Asserted Signal Detect -- Deasserted Signal detect -- Hysteresis Wavelength of Operation Electrical Data Output Voltage – Low Data Output Voltage – High Signal Detect Output Voltage -- Low Signal Detect Output Voltage -- High Signal Detect Output Voltage -- Low Signal Detect Output Voltage -- High
Symbol
Min
Typ
Max
Units
Notes
--Pin Pa Pd
---3 ---47 1.0 1100
---
-34 ---34 ---
dBm dBm dBm dBm dB nm
1
V OL - VCC V OH - VCC V OL - VCC V OH - VCC VOL VOH
-2.0 -1.1 -2.0 -1.1 2.0
---------
1600 -1.58 -0.74 -1.58 -0.74 0.5
V V V V V V
Transition: low to high Transition: high to low
2 2 TRSL-3380WG TRSL-3380CWG
Notes: 1. Minimum sensitivity and saturation levels at BER=1E-10 for a 223-1 PRBS with 72 ones and 72 zeros. 2. These outputs are compatible with 10K, 10KH and 100K ECL and PECL outputs.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
12/1/2005 V2.0
Optoway
TRSL-3380WG
3
**********************************************************************************************************************************************************************
ANALOG DIAGNOSTICS FUNCTIONS Parameter Transmitter Laser Bias Current Monitor Monitor Photodiode Current Monitor Receiver Received Photocurrent Photodiode Responsivity Applied Voltage at VpdR pin
Symbol
Min
Bmon+, BmonPmon+,Pmon-
0 0
Rpd R Vpd
0 0.5 2.4
Typ
0.9
Max
Units
Notes
Vcc Vcc
V V
1 2
1 1.0 Vcc
mA A/W V
3 3
Notes: 1. PIN 17 and 18 provide an analog voltage output proportional to the laser bias current, based on the following formula: Ibias = V (Bmon+ - Bmon-) / 10 Ω. See below the equivalent circuit. 2. PIN 19 and 20 provide an analog voltage output proportional to the monitor photodiode current, based on the following formula: Imon = V (Pmon+ - Pon-) / 200Ω. See below the equivalent circuit. 3. PIN 1 is used to monitor the received photocurrent. It must be connected to a positive voltage within the specified above. The received power is given by the photocurrent multiplied by the photodiode responsivity. VCC
VCC
LD
Monitor PD Vpdr
3K
I bias
BM+
3K
Pmon+
RX PD
I pd
200ohm
10ohm 3K
bias circuit
I mon
BM-
3K
Pmon-
control circuit
T
Analog Monitoring Function Connections
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
12/1/2005 V2.0
Optoway
TRSL-3380WG
4
**********************************************************************************************************************************************************************
CONNECTION DIAGRAM
PIN Symbol
Notes
PIN Symbol
1
VpdR Receiver power monitor. This pin must be 11
2 3
connected to a positive power supply (Vcc), preferably via a small resistor. Supplier photocurrent and maybe used to monitor receiver power. Receiver ground. 12 Receiver ground. 13
VeeR VeeR
Notes
VccT +3.3V dc transmitter power supply
VeeT Transmitter ground. T Dis Transmitter Disable. Connect this pin to logic “1”
4 5 6 7 8
NC NC VeeR VccR SD
No connected No connected Receiver ground. +3.3V dc receiver power supply Signal detect. Logic 1 indicate a normal operation.
14 15 16 17 18
TD + TD − VeeT Bmon− Bmon+
9 10
RD− RD+
Receiver Dataout Bar Receiver Dataout
19 20
PmonPmon+
MS
MS
to disable module. To enable module connect to logic low “0” Transmitter Data In Transmitter Data In Bar Transmitter ground. Laser Bias Monitoring – Negative End Laser Bias Monitoring – Positive End (Bmon+ - Bmon-) = 10 Ω X laser bias current Laser Power Monitoring -- Negative end Laser Power Monitoring -- Positive end (Pmon+ - Pmon-) = 200 Ω X monitor photdiode current
Mounting Studs. Connect to Chassis Ground
RECOMMENDED CIRCUIT SCHEMATIC Vcc3.3V
MICROSTRIP1
Tdis(LVTTL)
TD-
Z=50R MICROSTRIP2
Bmon-
LVPECL TD+
Z=5OR
Bmon+
150ohm
PmonPmon+
150ohm
VCC3.3V
20 19 18 17 16 15 14 13 12 11
1uH
Pmon+ PmonBmon+ BmonVeeTX TDTD+ Tdis VeeTX VccTX
100nF
Vcc3.3V Vcc3.3V
130R
1 2 3 4 5 6 7 8 9 10
RX
PHY DEVICE
10uF
1uH
VpdR VeeRX VeeRX NC NC VeeRX VccRX SD RDRD+
TX
100nF
100nF
Vcc3.3V
10uF RD+
200R
82R
MICROSTRIP3
VCCRX(3.3V)
RD-
Z=5OR
3K Vpdr
LVPECL
130R
Z=50R MICROSTRIP4
10nF
82R
1K
SD
TO LVPECL STAGE
Note: 1. TX input is terminated inside the module. 2. Veer and Veet are not internally connected to each other. 3. 50 Ω line pattern and component placements on TD+/TD- and RD+/RD- lines shall be symmetrical for better impedance matching. ***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw
12/1/2005 V2.0
Optoway
TRSL-3380WG
5
**********************************************************************************************************************************************************************
PACKAGE DIAGRAM Units in mm
1) Standard Case
TRSL-3380WG / TRSL-3380AWG / TRSL-3380CWG / TRSL-3380ACWG 2) Extended Case
TRSL-3380WEG / TRSL-3380AWEG / TRSL-3380CWEG / TRSL-3380ACWEG Note: Specifications subject to change without notice.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303 Tel: 886-3-5979798 Fax: 886-3-5979737 E-mail:
[email protected] http: // www.optoway.com.tw