Preview only show first 10 pages with watermark. For full document please download

True Rms Industrial Multimeter

   EMBED


Share

Transcript

True RMS Industrial Multimeter Technical Data MT1887 The MT1887 measures true-rms AC voltage and current readings, that yields accurate results on sine waves as well as non-sinusoidal waveforms using a frequency range of 50Hz to 1kHz. The MT1887 has a large LCD display screen where the accuracy is stated in 40,000 high resolution counts, supported with a 41 segment analogue bargraph and white back light, ideal for use in dimly lit areas. The MT1887 is an ideal tool for troubleshooting power distribution, industrial automations and for electronic and electrical field applications. This popular meter is also available in an intrinsically safe version. Features Include: IEC 61010-1 CAT lV 600V IEC 61010-1 CAT lll 1000V NCV IP67 Waterproof True Temperature 40000 RMS ACV/ACA · · · · · · · · · · · · · · · · · · COUNTS High Resolution General Specifications · · · Measures True RMS , AC Voltage and Current readings NEW! NCV detection IP67 Dust & Waterproof with O-Ring sealed casing Auto Range with Manual Override Measures Frequency on Electronic and Electrical Circuits Measures Resistance up to 40MΩ >1ms Peak Hold function Temperature between 20 °C to 1000 °C 4~20mA % Process loop measurements Capacitance to 40mF Relative Mode Data Hold Function Min/Max Recordings 0.06% Basic accuracy Diode Test and Continuity Buzzer Auto Power Off High resolution 40,000 Count LCD with 41 segment analogue bargraph IPG7 Overmould housing which disperses various shock over more of the case than conventional holsters Integrated Test Lead Holder Back Light for dimly lit areas Intrinsically safe version available on request Enclosure : Double molded, IP67 waterproof Shock (Drop Test) : 2 Meters Display : 4000 Count LCD display PEAK : Captures peaks >1ms AC Response : True rms AC True RMS : The term stands for "Root Mean Square", which represents the method of calculation of the voltage or current value. Average responding multimeters are calculated to read correctly only on sine waves and they will read inaccurately on non-sine wave or distorted signals. True rms meters read acurately on either type of signal. ACV Bandwidth : 50Hz to 1000Hz Diode Test : Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical Continuity Check : Audible signal will sound if the resistance is less than 35Ω Polarity Automatic; Minus (-) sign for negative Overrange Indication : "OL" is displayed Auto Power Off : Meter automatically shuts down after approximately 15 minutes of inactivity Measuring Rate : 2 Times per second nominal Low Battery Indication : " + " Is displayed if battery voltage drops below operating voltage ...to be continued p2/ General Specifications Battery : One 9 volt (NEDA 1604) battery Fuses : mA/A ranges: 0.5A/1000V ceramic fast blow : A range: 10A/1000V ceramic fast blow Operating Temperature : 5°C to 50°C Storage Temperature : -20°C to 60°C Operating Humidity : Max 80% up to 31°C decreasing linearly to 50% at 40°C 80% Storage Humidity 2000 Meters maximum Operating Altitude Weight : 375g Dimensions : 182 (H) x 82(W) x 55 (D) mm Safety : This meter is intended for origin of installation use and protected against the users by double insulation per ENS610101-1 and IEC61010-1 Measurement Range Resolution DC Voltage (Auto-ranging) 400.0mV 0.01mV 4.000V 0.1mV 40.00V 1mV 400.0V 10mV 1000V 100mV ± 1.0% of rdg ± 2 dgts 400.0mV 0.1mV ± 1.0% of rdg ± 4 dgts (50Hz to 100Hz) 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V 400.00μA 0.1μA 4000.0μA 1 μA 40.000mA 0.01mA 400.00mA 0.1mA 10A 0.01A 400.0μA 0.1μA 1μA 1 μA 0.01mA 0.01mA 0.1mA 0.1mA AC Voltage (Auto-ranging) DC Current (Auto-ranging for μA and mA) AC Current (Auto-ranging for μA and mA) Accuracy ± 0.06% of rdg ± 2 dgts ± 1.0% of rdg ± 3 dgts (50Hz to 1000Hz) ± 1.0% of rdg ± 3 dgts ± 1.5% of rdg ± 3 dgts 0.01A 0.01A Temperature 20°C ~ 1000°C 1°C ± 1.0% + 2.5°C -58°F ~ 1832°F 1°F ± 1.0% + 4.5°F Resistance (Auto-ranging) 400.0Ω 0.01Ω 4.000kΩ 0.0001Ω 40.00kΩ 0.001Ω 400.0kΩ 0.01Ω 4.000MΩ 0.0001MΩ Capacitance (Auto-ranging) Frequency Electronic (Auto-ranging) ± 0.3% of rdg ± 4 dgts 40.00MΩ 0.001MΩ ± 2.0% of rdg ± 10 dgts 40.000nF 1pF ± 3.5% of rdg ± 40 dgts 400.00nF 0.01nF 4.0000μF 0.1nF 40.000μF 1nF 400.00μF 10nF 4.000μF 0.1μF 40mF 0.001mF 40.000Hz 0.001Hz 400.00Hz 0.01Hz 4.0000kHz 0.0001kHz 40.000kHz 0.001kHz 400.00kHz 0.01kHz 4.0000MHZ 0.0001MHz 40.000MHZ 0.001MHz 100.00MHz 0.01MHz ± 3.5% of rdg ± 10 dgts ± 5.0% of rdg ± 10 dgts ± 0.1% of rdg ± 1 dgts Measurement Range Resolution Accuracy Frequency Electrical 40.00 ~ 400Hz 0.01Hz ± 0.5% of rdg Sensitivity: 15Vms Duty Cycle 0.1 ~ 99.9Hz 0.01% ± 1.2% of rdg ± 2 dgts 4 ~ 20mA% -25% tp 125% 0.01% ± 50 dgts Ordering Information HEAD OFFICE Cnr Rover and Jaguar Roads,Rustivia Ext 3, Elandsfontein P.O. Box 888, Isando 1600,South Africa Telephone: +27 11 822 1551 Sales Fax: +27 11 822 2806 Admin Fax: +27 11 822 1411 e-mail: [email protected] National Tel: 08 61 MAJORT / 08 61 62 5678 BRANCHES - DURBAN 6A Pastel Park, Wareing Road, Pinetown P.O. Box 15550, Ashwood 3605 Telephone: +27 31 701 5830 Sales Fax: +27 31 701 6986 BRANCHES - CAPE TOWN 109 Kyalami Drive, Killarney Gardens P.O. Box 60122, Tabelview 7439 Telephone: +27 21 556 3091 Sales Fax: +27 21 556 3093 BRANCHES - PORT ELIZABETH 175 Kempston Road, Sidwell P.O. Box 22499, Port Elizabeth 6000 Telephone: +27 41 453 3818 Sales Fax: +27 86 633 9809 www.major-tech.com