Transcript
TS190L Multifunction Telecom Switch
INTEGRATED CIRCUITS DIVISION Parameter Blocking Voltage Load Current On-Resistance (max)
Rating 400 150 25
Description
Units VP mArms / mADC
The TS190L integrated circuit device combines a current limited, 400V, normally open (1-Form-A) relay with an optocoupler in a single package. The relay, with enhanced peak load current handling capability, uses optically coupled MOSFET technology to provide 3750Vrms of input to output isolation.
Features • Current Limiting • 3750Vrms Input/Output Isolation • Low Drive Power Requirements (TTL/CMOS Compatible) • FCC Compatible • VDE Compatible • No EMI/RFI Generation • No Moving Parts • High Reliability • Arc-Free With No Snubbing Circuits • Small 8-Pin Package • Machine Insertable, Wave Solderable • Surface Mount Tape & Reel Version Available
Its optically coupled outputs, which use the patented OptoMOS architecture, are controlled by a highly efficient GaAIAs infrared LED. Telecom circuit designers, using the TS190L, can now take advantage of two discrete functions in a single component that uses less space than traditional discrete component solutions. Approvals • UL Recognized Component: File E76270 • CSA Certified Component: Certificate 1175739 • EN/IEC 60950 Certified Component: TUV Certificate: B 10 05 49410 006
Applications
Ordering Information
• Telecommunications • Telecom Switching • Tip/Ring Circuits • Modem Switching (Laptop, Notebook, Pocket Size) • Hook Switch • Dial Pulsing • Ground Start • Ringing Injection • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • Medical Equipment-Patient/Equipment Isolation • Security • Aerospace • Industrial Controls
Part # TS190PL TS190PLTR
Description 8-Pin Flatpack (50/Tube) 8-Pin Flatpack (1000/Reel)
Pin Configuration + LED - Relay – LED - Relay Collector - Phototransistor Emitter - Phototransistor
1
8
2
7
3
6
4
5
Load - Relay (MOSFET Output) Load - Relay (MOSFET Output) LED - Phototransistor –/+ LED - Phototransistor +/–
Switching Characteristics of Normally Open Devices Form-A IF 90% 10%
ILOAD ton
Pb DS-TS190L-R07
toff
e3 www.ixysic.com
1
INTEGRATED CIRCUITS DIVISION
TS190L
Absolute Maximum Ratings @ 25ºC Parameter Relay Blocking Voltage Reverse Input Voltage Relay Input Power Dissipation 1 Relay Input Control Current Peak (10ms) Detector Input Control Current Peak (10ms) Total Power Dissipation 2 Isolation Voltage, Input to Output Operational Temperature Storage Temperature 1
Derate linearly 1.33 mW / ºC
2
Derate linearly 6.67 mW / ºC
Ratings 400 5 150 50 1 100 1 800 3750 -40 to +85 -40 to +125
Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied.
Units VP V mW mA A mA A mW Vrms °C °C
Electrical Characteristics @25ºC: Relay Section Parameter Output Characteristics Load Current, Continuous Load Current Limiting On-Resistance Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics Input Control Current to Activate Input Control Current to Deactivate Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance
Conditions
Symbol
Min
Typ
Max
Units
IL=150mA VL=400V
IL ICL RON ILEAK
190 -
235 18 -
150 280 25 1
mArms / mADC mA
VL=50V, f=1MHz
ton toff COUT
-
25
1 0.25 -
ms ms pF
IL=150mA IF=5mA VR=5V
IF IF VF IR
0.4 0.9 -
0.7 1.2 -
5 1.4 10
mA mA V A
-
CI/O
-
3
-
pF
IF=5mA, VL=10V
A
Electrical Characteristics @25ºC: Detector Section Parameter Output Characteristics Phototransistor Blocking Voltage Phototransistor Dark Current Saturation Voltage Current Transfer Ratio Input Characteristics Input Control Current Input Voltage Drop Input Current (Detector must be off) Isolation, Input to Output Common Characteristics Input to Output Capacitance
2
Conditions
Symbol
Min
Typ
Max
Units
IC=10A VCE=5V, IF=0mA IC=2mA, IF=16mA IF=6mA, VCE=0.5V
BVCEO ICEO VCEsat CTR
20 33
50 50 0.3 100
500 0.5 -
V nA V %
IC=2mA, VCE=0.5V IF=5mA IC=1A, VCE=5V -
IF VF IF VI/O
0.9 5 3750
2 1.2 25 -
6 1.4 -
mA V A Vrms
-
CI/O
-
3
-
pF
www.ixysic.com
R07
INTEGRATED CIRCUITS DIVISION
TS190L
RELAY PERFORMANCE DATA @25ºC (Unless Otherwise Noted)* Typical LED Forward Voltage Drop (N=50, IF=5mA)
Typical Turn-On Time (N=50, IF=5mA, IL=150mADC)
Device Count (N)
25 20 15 10 5
25
20
20
15 10 5 0
0 1.17
1.19
1.21
1.23
15 10 5 0
0.15
1.25
0.21
0.27
0.33
0.39
0.45
0.51
0.038 0.045 0.052 0.059 0.066 0.073 0.080
LED Forward Voltage Drop (V)
Turn-On Time (ms)
Turn-Off Time (ms)
Typical IF for Switch Operation (N=50, IL=150mADC)
Typical IF for Switch Dropout (N=50, IL=150mADC)
Typical On-Resistance Distribution (N=50, IF=5mA, IL=150mADC)
25
25
20
20
Device Count (N)
Device Count (N)
25
15 10 5 0
35 30 Device Count (N)
Device Count (N)
30
Device Count (N)
35
Typical Turn-Off Time (N=50, IF=5mA, IL=150mADC)
15 10 5
1.55
1.85
2.15
2.45
2.75
20 15 10 5
0 1.25
25
0
3.05
0.95
1.25
LED Current (mA)
1.55
1.85
2.15
2.45
2.75
17.5
18.5
19.5
20.5
21.5
22.5
23.5
On-Resistance (:)
LED Current (mA)
Typical Blocking Voltage Distribution (N=50) 35
Device Count (N)
30 25 20 15 10 5 0 448
456
464
472
480
488
496
Blocking Voltage (VP)
Typical Turn-On Time vs. LED Forward Current (IL=150mADC)
0.30
1.8
1.4
IF=50mA IF=30mA IF=20mA IF=10mA IF=5mA
1.2 1.0 0.8
Turn-Off Time (ms)
1.6
0.20 0.15 0.10 0.05
-20
0
20
40
60
Temperature (ºC)
80
100
120
0.06 0.05 0.04 0.03 0.02
0 -40
Typical Turn-Off Time vs. LED Forward Current (IL=150mADC)
0.07
0.25 Turn-On Time (ms)
LED Forward Voltage Drop (V)
Typical LED Forward Voltage Drop vs. Temperature
0.01 0
5
10
15
20
25
30
35
40
LED Forward Current (mA)
45
50
0
5
10
15
20
25
30
35
40
45
50
Forward Current (mA)
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R07
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
TS190L
RELAY PERFORMANCE DATA @25ºC (Unless Otherwise Noted)* Typical Turn-On Time vs. Temperature (IL=150mADC)
IF=5mA IF=10mA IF=20mA
1.00 0.75 0.50 0.25 0 -40
4.0
-20
0
20
40
60
80
100
20 15 10 5
-20
0
20
40
60
80
-40
100
-20
0
20
40
60
80
Temperature (ºC)
Typical IF for Switch Operation vs. Temperature (IL=150mADC)
Typical IF for Switch Dropout vs. Temperature (IL=150mADC)
Maximum Load Current vs. Temperature
4.0
3.0 2.5 2.0
3.0 2.5 2.0 1.5 1.0
1.0 0
20
40
60
80
250 200 150
I F = 20mA I F = 10mA I F = 5mA
100 50 0
-20
-40
100
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
Temperature (ºC)
Temperature (ºC)
Temperature (ºC)
Typical Load Current vs. Load Voltage (IF=5mA)
Typical Blocking Voltage vs. Temperature
Typical Leakage vs. Temperature Measured Across Pins 7&8
Blocking Voltage (VP )
100 50 0 -50 -100 -150 -2.5 -2.0 -1.5 -1.0 -0.5
490
0.035
485
0.030
475 470 465 460 455
-40
0.5 1.0 1.5 2.0 2.5
-20
0.020 0.015 0.010
0
20
40
60
80
0 -40
100
-20
0
Temperature (ºC)
Load Voltage (V)
350
1.0
300
Current Limit (mA)
1.2
0.8 0.6 0.4 0.2 0 10μs 100μs 1ms 10ms 100ms
20
40
60
80
100
Temperature (ºC)
Typical Current Limiting vs. Temperature (IF=5mA)
Energy Rating Curve
Load Current (A)
0.025
0.005
450 445
0
120
480 Leakage (PA)
-20
100
300 Load Current (mA)
LED Current (mA)
LED Current (mA)
25
Temperature (ºC)
1.5
Load Current (mA)
30
3.5
-40
Typical On-Resistance vs. Temperature (IF=5mA, IL=150mADC)
Temperature (ºC)
3.5
150
0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 -40
On-Resistance (:)
1.25 Turn-Off Time (ms)
Turn-On Time (ms)
1.50
Typical Turn-Off Time vs. Temperature (IF=5mA, IL=150mADC)
250 200 150 100
1s
10s 100s
-40
-20
0
20
40
60
80
100
Temperature (ºC)
Time
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department.
4
www.ixysic.com
R07
INTEGRATED CIRCUITS DIVISION
TS190L
DETECTOR PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
7
3.5
6
3.0 2.5 2.0 1.5 1.0
5 4
2 1
0
0
4
6
8
10
12
14
Forward Current (mA)
16
18
20
IF=1mA IF=2mA IF=5mA IF=10mA IF=15mA IF=20mA
3
0.5 2
12
-40
-20
0
20
40
60
Temperature (ºC)
100
120
Collector Current (mA)
8
4.0 Normalized CTR
Normalized CTR
4.5
0
Typical Collector Current vs. Forward Current (VCE=0.5V)
Typical Normalized CTR vs. Temperature (VCE=0.5V)
Typical Normalized CTR vs. Forward Current (VCE=0.5V)
10 8 6 4 2 0
0
2
4
6
8
10
12
14
16
18
20
Forward Current (mA)
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R07
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
TS190L
Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device
Moisture Sensitivity Level (MSL) Rating
TS190PL
MSL 1
ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device
Maximum Temperature x Time
TS190PL
260ºC for 30 seconds
Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used.
Pb
6
e3
www.ixysic.com
R07
INTEGRATED CIRCUITS DIVISION
TS190L Mechanical Dimensions
TS190PL 0 MIN / 0.102 MAX (0 MIN / 0.004 MAX)
2.540 ± 0.127 (0.100 ± 0.005) 6.350 ± 0.127 (0.250 ± 0.005)
7.620 ± 0.254 (0.300 ± 0.010)
9.398 ± 0.127 (0.370 ± 0.005)
Pin 1
2.286 MAX. (0.090 MAX.)
2.54 (0.10) 0.635 ± 0.127 (0.025 ± 0.005) 8.70 (0.3425)
1.55 (0.0610)
0.203 ± 0.013 (0.008 ± 0.0005)
9.652 ± 0.381 (0.380 ± 0.015)
PCB Land Pattern
0.65 (0.0255)
2.159 ± 0.025 (0.085 ± 0.001)
0.457 ± 0.076 (0.018 ± 0.003) 0.864 ± 0.120 (0.034 ± 0.004)
Dimensions mm (inches)
TS190PLTR Tape & Reel 2.00 (0.079)
330.2 DIA. (13.00 DIA.)
Top Cover Tape Thickness 0.102 MAX. (0.004 MAX.)
Embossment
W = 16.00 (0.63)
7.50 (0.295)
Bo = 10.30 (0.406)
K0 = 2.70 (0.106) K1 = 2.00 (0.079)
Embossed Carrier
4.00 (0.157)
P = 12.00 (0.472) User Direction of Feed
Ao = 10.30 (0.406) Dimensions mm (inches)
NOTES: 1. All dimensions carry tolerances of EIA Standard 481-2 2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
7
Specification: DS-TS190L-R07 ©Copyright 2012, IXYS Integrated Circuits Division All rights reserved. Printed in USA. 12/22/2012
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
IXYS: TS190PL TS190PLTR