Preview only show first 10 pages with watermark. For full document please download

Ts190l Multifunction Telecom Switch

   EMBED


Share

Transcript

TS190L Multifunction Telecom Switch Parameters Load Voltage Ratings 400 Units VP Load Current 150 Max RON 25 mA Ω Features • Small 8-Pin Package • Through-hole and surface mount packages available • Low Drive Power Requirements (TTL/CMOS Compatible) • No Moving Parts • High Reliability • Arc-Free With No Snubbing Circuits • 3750Vrms Input/Output Isolation • FCC Compatible • VDE Compatible • No EMI/RFI Generation • Machine Insertable, Wave Solderable • Tape & Reel available for surface mount packages. • Telecommunications • Telecom Switching • Tip/Ring Circuits • Modem Switching (Laptop, Notebook, Pocket Size) • Hook Switch • Dial Pulsing • Ground Start • Ringing Injection • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • Medical Equipment-Patient/Equipment Isolation • Security • Aerospace • Industrial Controls RoHS DS-TS190L-R05 TS190L is a 400VP, 150mA, 25Ω, 1-Form-A current limiting relay with a bidirectional input, single transistor output optocoupler in a single package. The Solid State Relay (SSR) features enhanced peak load voltage capability with improved peak load current handling for specialized telecom applications. Approvals • UL Recognized: File Number E76270 • CSA Certified: File Number LR 43639-10 • Complies with: • EN 60950 • IEZC 950 • AS/NZ 3260 • EN 41003 Ordering Information Applications 2002/95/EC Description Part # TS190L Description 8-Pin DIP (50/Tube) TS190PL 8-Pin Flatpack (50/Tube) TS190PLTR 8-Pin Flatpack (1000/Reel) TS190LS 8-Pin Surface Mount (50/Tube) TS190LSTR 8-Pin Surface Mount (1000/Reel) Pin Configuration + LED - Relay – LED - Relay Collector - Phototransistor Emitter - Phototransistor 1 8 2 7 3 6 4 5 Load - Relay (MOSFET Output) Load - Relay (MOSFET Output) LED - Phototransistor –/+ LED - Phototransistor +/– e3 www.clare.com 1 TS190L Absolute Maximum Ratings Parameter Relay Portion Blocking Voltage Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Detector Portion Blocking Voltage Input Control Current Peak (10ms) Common Ratings Total Power Dissipation 2 Isolation Voltage Input to Output Operational Temperature Storage Temperature 1 Derate Linearly 1.33 mw/˚C 2 Derate Linearly 6.67 mw/˚C Ratings Units 400 5 50 1 150 VP V mA A mW 20 100 1 VP mA A 800 3750 -40 to +85 -40 to +125 mW Vrms °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Electrical absolute maximum ratings are at 25°C Electrical Characteristics Parameter Relay Portion (Pins 7, 8) Output Characteristics @ 25°C Load Current (Continuous) Load Current Limit On-Resistance Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Relay Portion (Pins 1, 2) Input Characteristics @ 25°C Input Control Current Conditions - Symbol Min Typ Max Units IL - - 150 mA mA Ω - ICL 190 235 280 IL=150mA RON - 18 25 VL=400V ILEAK - - 1 µA IF=5mA, VL=10V TON - - 1 ms IF=5mA, VL=10V TOFF - - 0.25 ms 50V; f=1MHz COUT - 25 - pF IL=150mA IF 5 - - mA - IF 0.4 0.7 - mA IF=5mA VF 0.9 1.2 1.4 V VR =5V Reverse Input Current Relay Portion Common Characteristics, Input to Output IR - - 10 µA CI/O - 3 - pF Input Dropout Current Input Voltage Drop Capacitance 2 - www.clare.com R05 TS190L Electrical Characteristics (Continued) Parameter Detector Portion (Pins 3,4) Output Characteristics @ 25°C Phototransistor Blocking Voltage Conditions Symbol Min Typ Max Units IC=10µA BVCEO 20 50 - V VCE=5V, IF=0mA ICEO - 50 500 nA Saturation Voltage IC=2mA, IF=16mA VCEsat - 0.3 0.5 V Current Transfer Ratio Detector Portion (Pins 5,6) Input Characteristics @ 25°C IF=6mA, VCE=0.5V CTR 33 100 - % Input Control Current IC=2mA, VCE=0.5V IF - 2 6 mA IF=5mA VF 0.9 1.2 1.4 V IF 5 25 - µA CI/O - 3 - pF Phototransistor Output Dark Current Input Voltage Drop IC=1µA, VCE=5V Input Current (Detector must be off) Detector Portion Common Characteristics, Input to Output Capacitance R05 - www.clare.com 3 TS190L PERFORMANCE DATA* 35 30 30 25 20 15 10 15 10 0 0 1.23 1.25 17.5 18.5 19.5 15 10 5 1.85 2.15 2.45 2.75 Load Current (mA) 5 0.95 1.25 1.55 2.15 2.45 5 200 150 IF = 20mA IF = 10mA IF = 5mA 100 Turn-On (ms) 470 465 460 455 -40 -20 0 20 40 60 80 20 40 10 5 0.15 0.21 0.27 60 Temperature (°C) 80 100 0.33 0.39 0.45 0.51 TS190L Typical Leakage vs. Temperature IF = Pins 7 & 8) (Measured across 0.025 0.020 0.015 0.010 100 0 120 -40 -20 0 TS190L Typical Turn-On vs. Temperature (Load Current = 150mADC) 1.00 0.75 IF = 5mA 0.50 0 IF = 10mA IF = 20mA -40 -20 0 20 40 20 40 60 80 100 Temperature (°C) 0.25 450 496 0.005 1.25 475 488 15 0.035 50 1.50 480 480 TS190L Typical Turn-On Time (N=50 Ambient Temperature = 25°C) (Load Current = 150mADC; IF = 5mADC) Temperature (°C) 485 472 0.030 TS190L Typical Blocking Voltage vs. Temperature 0 464 Turn-On (ms) 250 0 0.038 0.045 0.052 0.059 0.066 0.073 0.080 -20 456 20 0 2.75 TS190L Typical Load Current vs. Temperature Turn-Off (ms) Blocking Voltage (VP ) 1.85 60 Temperature (°C) 80 100 Turn-Off (ms) Device Count (N) 10 -40 448 Blocking Voltage (V) 10 300 15 445 0 23.5 LED Current (mA) TS190L Typical Turn-Off Time (N=50 Ambient Temperature = 25°C) (Load Current = 150mADC; IF = 5mADC) 490 22.5 15 3.05 20 0 10 25 LED Current (mA) 25 21.5 20 0 1.55 20.5 Device Count (N) 20 1.25 15 TS190L Typical IF for Switch Dropout (N=50 Ambient Temperature = 25°C; Load Current = 150mADC) 25 Device Count (N) Device Count (N) TS190L Typical IF for Switch Operation (N=50 Ambient Temperature = 25°C) (Load Current = 150mADC) 0 20 On-Resistance (Ω) LED Forward Voltage Drop (V) 25 25 5 Leakage (µA) 1.21 TS190L Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25°C) 30 20 5 1.19 35 25 5 1.17 TS190L Typical On-Resistance Distribution (N=50 Ambient Temperature = 25°C) (Load Current = 150mADC; IF = 5mADC) Device Count (N) 35 Device Count (N) Device Count (N) TS190L Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25°C; IF = 5mADC) 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 TS190L Typical Turn-Off vs. Temperature (Load Current = 150mADC) IF = 5mA -40 -20 0 20 40 60 80 100 Temperature (°C) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com R05 TS190L PERFORMANCE DATA* TS190L Typical LED Forward Voltage Drop vs. Temperature IF = 50mA IF = 30mA IF = 20mA IF = 10mA IF = 5mA 1.2 1.0 0.8 -40 -20 0 20 40 60 80 100 0.07 0.25 0.06 Turn-Off (ms) 1.4 Turn-On (ms) 1.6 0.30 0.20 0.15 0.03 0.02 0 120 0 5 10 30 35 40 45 0.01 50 15 10 0 20 40 10 60 80 3.0 2.5 2.0 100 150 -40 -20 1.2 100 20 25 30 35 40 45 50 4.0 1.5 1.0 15 3.5 TS190L Typical Load Current vs. Load Voltage (Ambient Temperature = 25°C; IF = 5mA) 0 20 40 60 80 3.0 2.5 2.0 1.5 1.0 100 -40 -20 0 20 40 60 80 100 Temperature (°C) Temperature (°C) TS190L Energy Rating Curve TS190L Typical Current Limiting Characteristics vs. Temperature IF = 5mA 350 0 -50 -100 Current Limit (mA) Load Current (A) 1.0 50 0.8 0.6 0.4 0.2 -150 -2.5 -2.0 -1.5 -1.0 -0.5 0 0 10µs 100µs 1ms 10ms 100ms 0.5 1.0 1.5 2.0 2.5 Load Voltage (V) 1s 300 250 200 150 100 10s 100s Time TS190L Typical Normalized CTR vs. Forward Current (VCE = 0.5V) -40 8 12 4.0 7 10 Normalized CTR 3.0 2.5 2.0 1.5 1.0 0.5 6 2 4 6 8 10 12 IF (mA) 14 16 18 20 4 IF = 1mA IF = 2mA IF = 5mA IF = 10mA IF = 15mA IF = 20mA 3 2 0 20 40 60 80 100 8 5 1 0 0 TS190L Typical Collector Current vs. Forward Current (VCE = 0.5V) TS190L Typical Normalized CTR vs. Temperature (VCE = 0.5V) 3.5 -20 Temperature (°C) 4.5 0 5 TS190L Typical IF for Switch Dropout vs. Temperature (Load Current = 150mADC) LED Current (mA) LED Current (mA) 20 -20 0 Forward Current (mA) 4.0 Temperature (°C) Load Current (mA) 25 3.5 25 Normalized CTR 20 TS190L Typical IF for Switch Operation vs. Temperature (Load Current = 150mADC) 30 On-Resistance (Ω) 15 LED Forward Current (mA) TS190L Typical On-Resistance vs. Temperature (Load Current = 150mADC; IF = 5mADC) -40 0.04 0.05 Temperature (°C) 5 0.05 0.10 -40 -20 0 20 40 60 Temperature (°C) 80 100 120 IC (mA) LED Forward Voltage Drop (V) 1.8 TS190L Typical Turn-Off vs. LED Forward Current (Load Current = 150mADC) TS190L Typical LED Forward Current vs. Turn-On (Load Current = 150mADC) 6 4 2 0 0 2 4 6 8 10 12 14 16 18 20 IF (mA) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R05 www.clare.com 5 TS190L Manufacturing Information Soldering Recommended soldering processes are limited to 260ºC component body temperature for 10 seconds. Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents. e3 RoHS 2002/95/EC MECHANICAL DIMENSIONS 8-Pin DIP Through Hole (Standard) 2.540 ± 0.127 8-0.800 DIA. (0.100 ± 0.005) (8-0.031 DIA.) 2.540 ± 0.127 (0.100 ± 0.005) 7.620 ± 0.254 (0.300 ± 0.010) 7.239 TYP. (0.285) PC Board Pattern (Top View) 9.652 ± 0.381 (0.380 ± 0.015) 3.302 (0.130) 9.144 ± 0.508 (0.360 ± 0.020) 6.350 ± 0.127 (0.250 ± 0.005) 9.144 TYP. (0.360) 6.350 ± 0.127 (0.250 ± 0.005) 7.620 ± 0.127 (0.300 ± 0.005) 0.457 ± 0.076 (0.018 ± 0.003) 7.620 ± 0.127 (0.300 ± 0.005) 8.077 ± 0.127 (0.318 ± 0.005) 8-Pin Surface Mount (“S” Suffix) 7.620 ± 0.254 (0.300 ± 0.010) 4.445 ± 0.127 (0.175 ± 0.005) 3.302 (0.130) PC Board Pattern (Top View) 2.540 ± 0.127 9.652 ± 0.381 (0.380 ± 0.015) (0.100 ± 0.005) 2.540 ± 0.127 (0.100 ± 0.005) 0.635 TYP. (0.025) 8.305 ± 0.127 (0.327 ± 0.005) 9.525 ± 0.254 (0.375 ± 0.010) 6.350 ± 0.127 (0.250 ± 0.005) 1.905 ± 0.127 (0.075 ± 0.005) 0.254 TYP. (0.010) 0.457 ± 0.076 (0.018 ± 0.003) 1.498 ± 0.127 (0.059 ± 0.005) 8.077 ± 0.127 (0.318 ± 0.005) PC Board Pattern (Top View) 9.652 ± 0.381 (0.380 ± 0.015) 8-Pin Flatpack (“P” Suffix) 2.540 ± 0.127 (0.100 ± 0.005) 7.620 ± 0.254 2.159 TYP. (0.300 ± 0.010) (0.085) 2.286 MAX. (0.090) 0.635 ± 0.127 (0.025) 6.350 ± 0.127 (0.250 ± 0.005) 2.540 ± 0.127 (0.100 ± 0.005) 9.398 ± 0.127 (0.370 ± 0.005) 0.203 (0.008) 0.457 ± 0.076 (0.018 ± 0.003) 8.077 ± 0.127 (0.318 ± 0.005) 8.763 ± 0.127 (0.345 ± 0.005) 1.193 (0.047) 0.787 (0.031) Dimensions: mm (inches) 6 www.clare.com R05 MECHANICAL DIMENSIONS Tape and Reel Packaging for 8-Pin Surface Mount Package 330.2 DIA. (13.00 DIA.) Top Cover Tape Thickness 0.102 MAX. (0.004 MAX.) 1 8 W = 16.30 max (0.642 max) Bo = 10.30 (0.406) Top Cover Tape P = 12.00 (0.472) Embossed Carrier Embossment K1 = 4.20 (0.165) Ao = 10.30 (0.406) User Direction of Feed K0 = 4.90 (0.193) NOTE: Tape dimensions not shown, comply with JEDEC Standard EIA-481-2 Tape and Reel Packaging for 8-Pin Flatpack Package 330.2 DIA. (13.00 DIA.) Top Cover Tape Thickness 0.102 MAX. (0.004 MAX.) 1 8 W = 16.30 max (0.642 max) Bo = 10.30 (0.406) Top Cover Tape Embossed Carrier P = 12.00 (0.472) Embossment K1 = 2.20 (0.079) Ao = 10.30 (0.406) User Direction of Feed K0 = 2.70 (0.106) NOTE: Tape dimensions not shown, comply with JEDEC Standard EIA-481-2 Dimensions: mm (inches) For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. 7 Specification: DS-TS190L-R05 © Copyright 2005, Clare, Inc. All rights reserved. Printed in USA. 11/18/05