Preview only show first 10 pages with watermark. For full document please download

Tt Series Transmitters

   EMBED


Share

Transcript

www.texmate.com Since 1976 TT Series Transmitters Custom input and output signal adjustment can be recalibrated with TT Configurator software. Transmitters can be configurated without connecting to a power source. MODEL OFFERED TT-1S1M Single Channel input and Single 4-20mA output TT-2D2MM Dual Inputs; Dual 4-20mA output TT-2D2MC Dual Inputs; Single 4-20mA & Single RS-485 output TTM-2S2MM Dual same signal Inputs; Single 4-20mA output and Single 4-20mA output with Math Function TTM-2S2MC Dual same signal Inputs; Single 4-20mA output with math function & Single RS-485 output FEATURES Output = A(Input1) + B(Input2) C 4Various input signal Resistance thermometer (Pt100) Thermocouple (J,K,T,E,B,R,S,N,C) Voltage/Current transmitter (mV/V/mA) A,B,C values adjustable via utility software. Square root function may be suitched ON or OFF. 4Configurable without power connected 4Full 3-way isolation for 2800 Vrms. 4Compact, 18.5mm, DIN rail mount. Input 1 4Single or Dual 0/4 to 20 mA or optional 0 to 10V Analog output (dual inputs models only) Input 2 I N P U T S I S O L A T I O N O U T P U T S Output 1 Output 2 I S O L AT I O N 4Fault signal on sensor break presettable 24VDC POWER 4Optional RS485 communication interface with Modbus RTU 1 (Z668) www.texmate.com Since 1976 TT Series Transmitters FUNCTIONAL DIAGRAM 2800 PINOUTS *Inputs must be of same type INPUT 2 _ _ _ V C 7 1 _ _ C 2 V _ 3 + + 1 _ _ RTD INPUT 1 4 _ 5 8 9 2 3 + + V _ _ _ 1 OUTPUT1 TT-1S1M C _ 2 3 + + _ _ _ 5 6 10 11 12 + _ OUTPUT2 TT-2D2MM V C 1 _ _ C RTD _ 2 3 + + _ _ _ V 5 6 10 11 12 1 _ _ _ 3 + + + RTD INPUT 1* 4 5 6 10 11 12 24V DC 2 T/C OUTPUT1 _ + + 9 V _ RTD C 8 + OUTPUT1 _ + + _ 4 5 6 10 11 12 24V DC TX _ TX RS-485 _ OUTPUT2 + TX _ TX RS-485 TT-2D2MC TTM-2S2MM TT-2S2MC 2 + C 7 + +RTD + + T/C INPUT 1* 4 24V DC 9 T/C OUTPUT1 _ + + INPUT 2* 8 V _ + +RTD + + T/C 7 INPUT 1 4 24V DC 9 T/C OUTPUT1 _ + + INPUT 2* 8 V _ INPUT 1 + 6 V C _ _ RTD + RTD + + T/C 7 + T/C LOAD + 10-36 VDC C _ + T/C +RTD + + T/C INPUT 2 (Z668) www.texmate.com Since 1976 TT Series Transmitters APPLICATIONS *Inputs must be of same type Single Channel Transmitter Dual Channel With Math 1 _ _ C 2 V _ 3 + + Set square root A,B,C constants via Utility software + 4 _ 5 LOAD + 9 1 2 3 + 4 5 6 10 11 12 _ 24V DC RTD 12-36 VDC 8 OUTPUT1 _ + + T/C 7 _ INPUT 1* Output = A(Input1) + B(Input2) C INPUT 1 Current Voltage Thermocouple RTD INPUT 2* _ + + + TX _ TX RS-485 TT-2S2MC 6 OUTPUT1 Quad Loop Splitter TT-1S1M TT-2D2MM _ Dual Loop Repeater + 7 8 9 INPUT 1 1 2 3 2 3 4 5 6 10 11 12 OUTPUT2 _ INPUT OUTPUT1 + Isolated 4 to 20 mA TT-2D2MM + _ 4 to 20 mA Isolated 4 to 20 mA _ + 7 8 9 1 2 3 + 4 5 6 10 11 12 OUTPUT2 _ 1 4 to 20 mA INPUT 2 24V DC 9 _ 24V DC 4 to 20 mA _ + _ 8 Isolated 4 to 20 mA _ + TT-2D2MM + 7 Isolated 4 to 20 mA _ + OUTPUT1 + 4 5 6 10 11 12 OUTPUT2 _ 24V DC + OUTPUT1 + _ Isolated 4 to 20 mA Isolated 4 to 20 mA 3 (Z668) www.texmate.com Since 1976 TT Series Transmitters SPECIFICATIONS Output signal : DC 4/0~20mA or optional DC 0~10V Output resolution : 0.6uA. Output response time : <200mS. Communication : Modbus RS485 RTU protocol, 4800~38400 bps Power supply : 18~36 VDC, internal protection against polarity inversion Input signal Maximum Range Thermocouple J -50 to 1000°C (-58 to 1832°F) Thermocouple K -50 to 1370°C (-58 to 2498°F) Thermocouple T -270 to 400°C (-454 to 752°F) Thermocouple E -50 to 700°C (-58 to 1292°F) Thermocouple B 0 to 1750°C (32 to 3182°F) Thermocouple R Thermocouple S Accuracy ±1°C ±2°C ±2°C Thermocouple N -50 to 1300°C (-58 to 2372°F) Thermocouple C -50 to 1800°C (-58 to 3272°F) Pt100* -200 to 600°C (-328 to 1112°F) ±0.2°C mV -60.00 mV to 60.00 mV ±0.01mV 2 -10.000 to 10.000 Vdc ±1mV Current 2 0.000 to 24.000 mAdc ±3μA * Factory setting TT-1SIM Single Input Only Single 4-20mA Output TT-2D2MM Two Independent Inputs Output1 = 4-20mA (IN1) Output2 = 4-20mA (IN2) TT-2D2MC Two Independent Inputs Output1 = 4-20mA (IN1) Output2 = RS-485 (IN2) TTM-2S2MM Two Inputs (must be of same type) Output1 = 4-20mA (IN1 or f(IN1,IN2)) Output2 = 4-20mA (IN2) TTM-2S2MC Two Inputs (must be of same type) Output1 = 4-20mA (IN1 or f(IN1,IN2)) Output2 = RS-485 (IN2) Accuracy is not guaranteed between 0 and 400°C (0 and 752°F) for type B, R and S. Rang set by an internal DIP switch. 87mm (3.43”) 2 Description of Outputs CASE DIMENSIONS 83 mm (3.27”) 1 Number of Inputs 1 -50 to 1750°C (-58 to 3182°F) Voltage Model No. 75 mm (2.95”) Since 1976 • For ordering info call: 1-800-TEXMATE or 760 598-9899 • Email: [email protected] • 24 Hours • Fax: (760) 598-9828 • For tech assistance call: (760) 598-9899 450 State Place, Escondido, CA 92029 4 18.5 mm (0.73”) Local Distributor Address Copyright © 2017 Texmate Inc. All Rights Reserved. (Z668) Math NO Yes