Transcript
USER MANUAL
THERA GB2 MONITOR
Code 50121889
TTHERA GB2 EN REV.0116
THERA GB2 MONITOR
2
INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen from our ISO-9001 certification and from the manufacturing of products like this one. Its advanced technology and exacting quality control will ensure that customers and users enjoy the many features this system offers. To obtain the maximum benefit from these features and a properly wired installation, we kindly recommend that you spend a few minutes of your time reading this manual.
CONTENTS Introduction.................................................................................................................................................................... 2 Contents.........................................................................................................................................................................2 Safety precautions..........................................................................................................................................................2 Characteristics............................................................................................................................................................... 3 System operation........................................................................................................................................................... 3 Monitor description........................................................................................................................................................... Description...................................................................................................................................................................4 Function push buttons.................................................................................................................................................. 4 Connection terminals................................................................................................................................................... 4 Configuration dip switch............................................................................................................................................... 4 Setting the monitor's address codes............................................................................................................................. 5 Installation of the monitor in a surface box....................................................................................................................... 6 Installation of the monitor in an embedding box................................................................................................................7 Operation....................................................................................................................................................................... Description............... ....................................................................................................................................................8 1.1 Receiving a call from the door panel........................................................................................................................8 1.2 The call is unanswered (resident unavailable).........................................................................................................9 1.3 Ending a call from the door panel............................................................................................................................ 9 1.4 Answering a call from the door panel.....................................................................................................................10 Monitor screen and volume settings menu (normal, bright, soft image or user / brightness, contrast and colour)........10-11 User menu....................................................................................................................................................................... Accessing the menu................................................................................................................................................... 11 1.1 Displaying the main door panel image...................................................................................................................12 1.2 Displaying images from the door panels................................................................................................................13 1.3 Displaying camera images (D-CAM-GB2 module required).................................................................................. 14 2.1 Intercom calls (inner Broadcast)........................................................................................................................... 15 2.2 Intercom calls within an apartment........................................................................................................................16 2.3 Intercom calls between apartments................................................................................................................. 17-18 2.4 Calling the surveillance monitor............................................................................................................................ 19 3.1 Viewing photos and videos of door panel calls/cameras and deleting photos and videos (Micro-SD card required for video)......................................................................................................................20 4.1 Viewing the call log................................................................................................................................................21 5.1 Do not disturb mode.............................................................................................................................................. 22 6.1 Divert call mode (GSM-GB2 module required).......................................................................................................23 7.1 Exiting the user menu function...............................................................................................................................24 8.1 Settings (sounds, date and time, language, default setup, installer setup, etc.).................................................24-31 Monitor cleaning........................................................................................................................................................... 31 Annex: Changing the monitor's day mode time range..............................................................................................33-34
SAFETY PRECAUTIONS - Do not use excessive force when tightening the monitor's connection block screws. - Always disconnect the power supply before making modifications to the equipment. - The fitting and handling of these devices must be carried out by authorised personnel. - The wiring must run at least 40 cm away from any other wiring installations. - Install the monitor in a dry protected location free from the risk of dripping or splashing water. - Do not place in humid, dusty or smoky locations, or near sources of heat. - Before connecting the system to the mains, check the connections between the door panel, power supply, distributors and monitors. - Always follow the instructions contained in this manual.
THERA GB2 MONITOR CHARACTERISTICS - Hands-free monitor. - 7" TFT colour screen. - Monitor with simple installation (unpolarised 2 wire BUS). - Touch screen for access and selection of menu functions: User menu: - Display image from door panel(s). - Display camera images (D-CAM-GB2 module required). - Intercom calls within an apartment (inner broadcast). - Intercom calls within an apartment (inner call). - Intercom calls between apartments (name list call). - Call the surveillance monitor. - Display photos of door panel calls/cameras and delete photos (internal memory, capacity 118 photos). - Display videos of door panel calls/cameras and delete videos (Micro-SD card required, using this card cancels the photos option). - Calls received log. - Do not disturb mode (door panel or intercom calls are not received). - Divert call (GSM-GB2 module required). - Setup: ring tone, call volume, auto switch-on time, rename door/camera, time and date. - Language selection (Spanish, English, French, Portuguese or Dutch). Installer menu: - Monitor as master or (slave 1, slave 2 or slave 3). Up to 4 monitors per apartment. - Surveillance monitor. - Allow the door panel image to be displayed on the slave monitor during a call. - Activate intercom calls between apartments. Screen and volume settings menu: (during auto switch-on or communication). - Scene: Normal, bright, soft or user image. - Brightness, contrast and colour. - Monitor speaker volume. - Start / stop communication capacitive touch switch. In standby it also displays the door panel image. - Menu access capacitive touch switch. - Door release activation capacitive push button. - Different ring tones indicate the origin of the call (door panel, intercom or apartment door). - Dip switches for setting the monitor address (call code). - Input for calls from the landing door. - Call repeater output (SAR-12/24).
SYSTEM OPERATION - To make a call, the visitor must press the button of the apartment; an acoustic tone will be heard confirming the call is in progress once the push button has been pressed and the LED will turn on. If vocal synthesis is activated then a “call is in progress” message will be heard confirming the call is in progress. At this moment the apartment's monitor receives the call. During the call the visitor can correct his call by pressing a push button corresponding to a different apartment, in which case the original call is cancelled. - The call lasts for 40 seconds. Without alerting the visitor, their image appears on the master monitor during this time. To view the picture on a slave monitor this function must first be activated in the monitor. For kit villa application: the image appears on the monitor (with address code 0 “apartment 1” or monitor with address code 16 if the call is in “apartment 2”) when receiving the call without the visitor being alerted. If the call is not answered within 40 seconds, LED will turn off and the channel will be freed. - To establish communication, press the monitor's push button and the door panel's LED will turn on. If the vocal synthesis is enabled the message “you can speak now” will be Heard confirming the communication is activated. - Communication will last for one and a half minutes or until the push button is pressed again. When communication has finished, LEDs and will turn off and the system will be freed. If vocal synthesis is activated then a “communication is finished” message will be heard in the door panel confirming the communication has finished. - To open the door press the push button during the call or communication processes: one press will activate the door release for five seconds and LED will also turn on for five seconds. If vocal synthesis is activated then a “door is open” message will be heard in the door panel. - The descriptions of the function push buttons are found on page 4.
3
4
THERA GB2 MONITOR MONITOR DESCRIPTION
7” TFT colour screen. Start/stop communication push button. During standby: Display the door panel image.
Micro SD Card
Menu access button. Door release push button. Microphone. Monitor status light.
Attachment holes. BUS connection terminals. ON 1
Con#guration DIP switch.
DIP 2
3
4
5
6
Connector.
Installation terminals and dip switch: Connection terminals: L1, L2: BUS Connection. HZ+, HZ-: Door bell push button connection. CALL REPEATER, GND: Call repeater connection , (SAR-12/24). (12Vcc/50mA maximum).
ON 1
DIP 2
3
4
5
6
Configuration dip switch: Dip6: Sets the end of line. Set to ON in monitors where the bus cable terminates. Set to OFF only in intermediate monitors. Dip1 a Dip5: Set the monitor address (addresses 0 to 31). Switches set to OFF have a value of zero. The values of the switches set to ON are shown in the enclosed chart. The monitor code will be the sum of the values of the switches set to ON.
L1 L2 ON
Value chart Switch number: 1 2 3 4 ON value: 1 2 4 8 16
5
ON 1
DIP 2
3
4
5
6
Example: 0 + 0 + 4 + 0 +16 = 20
1
DIP 2
3
4
5
6
(YELLOW): DO NOT USE (BLACK): GND (RED): CALL REPEATER (GREEN): HZ(WHITE): HZ+
5
THERA GB2 MONITOR MONITOR DESCRIPTION Setting the monitor's address codes (addresses 0 to 31): Dip6: Sets the end of line. Set to ON in monitors where the bus cable terminates. Set to OFF only in intermediate monitors.
Dip6 to OFF
Dip6 to ON ON 1
DIP 2
3
4
5
6
ON 1
DIP 2
3
4
5
6
Dip1 to Dip5: Set the monitor address (addresses 0 to 31).
Code 00
Code 09
ON 1
DIP 2
3
4
5
6
ON 1
Code 01 DIP 2
3
4
5
6
DIP 3
4
1
5
6
DIP 3
4
1
5
6
DIP 3
4
1
5
6
DIP 3
4
1
5
6
DIP 3
4
1
5
6
DIP 3
4
1
5
6
DIP 3
4
1
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
1
5
6
3
4
5
6
5
6
DIP 2
3
4
3
4
5
6
1
DIP 2
3
4
5
6
DIP 2
3
4
5
6
DIP 2
3
4
5
ON 1
6
DIP 2
3
4
5
ON 1
6
DIP 2
3
4
5
ON 1
6
DIP 2
3
4
5
6
5
ON 1
6
DIP 2
3
4
4
5
6
ON 1
DIP 2
3
4
5
6
ON 1
DIP 2
3
4
5
6
ON 1
DIP 2
3
4
5
6
Code 31
ON 1
3
Code 30
ON 1
2
Code 29
Code 26
ON 1
2
Code 25 DIP
2
DIP
Code 24 DIP
2
1
DIP
Code 28
Code 23 DIP
2
6
Code 22 DIP
2
5
Code 21 DIP
2
4
ON
Code 17
ON 2
DIP 2
3
ON
Code 20
ON
Code 08
1
6
Code 16
ON 2
5
ON
Code 07
1
4
Code 15
ON 2
3
ON
Code 06
1
2
2
ON
Code 14
ON 2
DIP
ON
Code 05
1
1
Code 13
ON 2
6
DIP
Code 19
ON
Code 04
1
5
Code 12
ON 2
4
ON
Code 03
1
3
Code 27
ON
Code 11
ON 2
2
ON
Code 02
1
DIP
Code 10
ON 1
Code 18
5
6
ON 1
DIP 2
3
4
5
6
6
THERA GB2 MONITOR INSTALLING THE MONITOR IN A SUP-GB2 SURFACE BOX Avoid placing the monitor near sources of heat, in dusty locations or smoky environments.
Positioning the SUP-GB2 surface box: The upper part of the SUP-GB2 surface box must be positioned at a height of 1.60 m. The minimum distance between the sides of the surface box and the closest object must be 5 cm.
1.60m
Fixing the SUP-GB2 surface box to the wall: To #x the SUP-GB2 surface box to the wall, drill two 6 mm diameter holes and use the screws and plugs supplied with the SUP-GB2.
4 x 30
Positioning the monitor: Connect the cables to the monitor (see page 4), position the monitor perpendicular to the SUP-GB2 surface box ensuring that the holes in the base of the monitor line up with those on surface box 1 , and then move the monitor towards surface box 2 , until the monitor is #xed with the magnets located on monitor 3 . Remember to remove the protective covering from the front of the monitor once installation has been completed.
1
2
3
7
THERA GB2 MONITOR INSTALLING THE MONITOR IN A UNIVERSAL EMBEDDING BOX Avoid placing the monitor near sources of heat, in dusty locations or smoky environments.
Positioning the embedding box: Make a hole in the wall to position the top of the universal embedding box at a height of 1.60 m from the ground. The minimum distance between the embedding box and the closest object must be 5 cm.
1.60m
Positioning the embedding box and mounting the terminal block: Pass the cable through the hole made in the embedding box. Embed the box and ensure that it is level and $ush. Fix the terminal block of the monitor with the screws supplied with the embedding box.
Screws supplied with the embedding box.
Positioning the monitor: Connect the cables to the monitor (see page 4), position the monitor perpendicular to the terminal block ensuring that the holes in the base of the monitor line up with those on terminal block 1 , and then move the monitor towards terminal block 2 , until the monitor is #xed with the magnets located on monitor 3 . Remember to remove the protective covering from the front of the monitor once installation has been completed.
1
2
3
8
THERA GB2 MONITOR OPERATION Monitor description upon receiving a call and during communication: Elapsed call/communication time. Door panel that made the call. Communication enabled. Door 1 activated. Door 2 activated. Photo or video capture activated, (Micro-SD card required for video recording).
00:30 PL-1
1
2
REC
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End call/communication. Activate door release 1. Call: light blinks. Communication: light #xed. Start/stop communication.
1.1 Receiving a call from the door panel: When a call is received, the monitor(s) will play a melody (the status light of the monitor(s) will blink) and show the image of the door panel on the main monitor without alerting the visitor. If the call is not answered in 40 seconds the monitor returns to standby. The monitor automatically takes a photo or records a video (Micro-SD card required for video).
00:30 PL-1
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End call.
To open the door, press the door release push button during the call: one press will activate the lock release for 5 seconds. Continued overleaf
9
THERA GB2 MONITOR OPERATION Continued from the previous page.
1.2 The call is unanswered (resident unavailable): When a call is received, the monitor(s) will play a melody (the status light of the monitor(s) will blink) and show the image of the door panel on the main monitor without alerting the visitor. If the call is not answered in 40 seconds the monitor returns to standby. The monitor automatically takes a photo or records a video (Micro-SD card required for video). A low and variable intensity monitor status light indicates that there is a missed call (see “call log” in the monitor's menu). 00:30 PL-1
1.3 Ending a call from the door panel: When a call is received, the monitor(s) will play a melody (the status light of the monitor(s) will blink) and show the image of the door panel on the main monitor without alerting the visitor. The monitor automatically takes a photo or records a video (Micro-SD card required for video). To end the call, press option . To open the door, press button during the call: one press will activate the lock release for 5 seconds. A low and variable intensity monitor status light indicates that there is a missed call (see “call log” in the monitor's menu).
00:30 PL-1
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End call.
To open the door, press the door release push button during the communication or call processes: one press will activate the lock release for 5 seconds.
Continued overleaf
10
THERA GB2 MONITOR OPERATION Continued from the previous page.
1.4 Answering a call from the door panel: When a call is received, the monitor(s) will play a melody (the status light of the monitor(s) will blink) and show the image of the door panel on the main monitor without alerting the visitor. The monitor automatically takes a photo or records a video (Micro-SD card required for video). To answer the call, press button . Communication will last for one and a half minutes or until button is pressed again. To open the door, press button during the communication or call processes: one press will activate the lock release for 5 seconds.
00:30 PL-1
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End call/communication.
Start/stop communication. To open the door, press the door release push button during the communication or call processes: one press will activate the lock release for 5 seconds.
SCREEN AND VOLUME SETTINGS MENU To access the screen and volume settings menu in the monitor, it must be in communication or auto switch-on mode. Next, press option , and the #rst selection screen will be displayed. 00:30 PL-1
00:30 PL-1
To access scene settings press option . The following selection screen is displayed. Select the type of image required (normal, brightly, soft or user) by pressing the respective option. Press “door panel image” shown on the screen to exit and return to the #rst selection screen.
First selection screen 00:30 PL-1
5 5 5 Normal Brightly
Soft
User
4
Continued overleaf
11
THERA GB2 MONITOR OPERATION Continued from the previous page. To access the brightness, contrast and colour settings, press option . The following selection screen is displayed. Press option or in each selection #eld to increase or decrease brightness , contrast and colour . Press “door panel image” shown on the screen to exit and return to the #rst selection screen.
First selection screen 00:30 PL-1
5 5 5 Normal Brightly Soft User
4
To access the monitor's volume setting, press option . The following selection screen is displayed. Press option or in selection to increase or decrease the volume. Press “door panel image” shown on the screen to exit and return to the #rst selection screen. Press option to exit the screen and volume settings menu.
First selection screen 00:30 PL-1
5 5 5 Normal Brightly Soft User
4
USER MENU To access the menu, the monitor must be in standby. Then press on the screen or press menu button
.
The main menu options screen will then appear.
Main menu screen
08 : 45 Mon. 09/11/2015
INFO SYSTEM
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Continued overleaf
12
THERA GB2 MONITOR USER MENU Continued from the previous page.
1.1 Displaying the main door panel image: To display the main door panel image, press “Camera/Door”. The following selection screen will be displayed. Press option “Door1”.
08 45 08 08 ::: 45 45 Mon. Mon. Mon. 09/11/2015 09/11/2015 09/11/2015
INFO SYSTEM
CAMERA PLACA / /PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Monitor settings.
DOOR 1
DOOR 2
DOOR 3 2
CAMERA 1
CAMERA 2
CAMERA DOOR 2 3
DOOR 4
CAMERA 4
Main menu.
The following screen will display the image from the door panel with address 1, it will also indicate the selected door panel 'PL-1' and the elapsed connection time. The connection will last for 30 seconds or until option is pressed. 00:30 PL-1
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End auto switch-on. (Return to the selection screen).
To establish audio and video communication with the selected door panel press button . The screen will display symbol . Communication will last for 30 seconds or until button is pressed again or option is pressed. To open the door, press the button during the image display or communication processes: one press will activate the lock release for 5 seconds. This symbol is displayed only when communication mode is enabled. 00:30 PL-1
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End communication with the door panel. (Return to the selection screen).
Continued overleaf
13
THERA GB2 MONITOR USER MENU Continued from the previous page.
1.2 Displaying images from the door panels: To display the image from one of the installed door panels, press “Camera/Door”. The following selection screen will be displayed. Press the option corresponding to the desired door panel “Door” from which to visualise an image.
08 45 08 08 ::: 45 45 Mon. Mon. Mon. 09/11/2015 09/11/2015 09/11/2015
INFO SYSTEM
CAMERA PLACA / /PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Monitor settings.
DOOR 1
DOOR 2
DOOR 3 2
CAMERA 1
CAMERA 2
CAMERA DOOR 2 3
DOOR 4
CAMERA 4
Main menu.
The following screen will display the image from the door panel with address 2, it will also indicate the selected door panel 'PL-2' and the elapsed connection time. The connection will last for 30 seconds or until option is pressed. 00:30 PL-2
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End auto switch-on. (Return to the selection screen).
To establish audio and video communication with the selected door panel press button . The screen will display symbol . Communication will last for 30 seconds or until button is pressed again or option is pressed. To open the door, press the button during the image display or communication processes: one press will activate the lock release for 5 seconds. This symbol is displayed only when communication mode is enabled. 00:30 PL-1
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End communication with the door panel. (Return to the selection screen).
Continued overleaf
14
THERA GB2 MONITOR USER MENU Continued from the previous page.
1.3 Displaying camera images (D-CAM-GB2 module required): To display the image from one of the installed cameras, press “Camera/Door”. The following selection screen will be displayed. Press the option corresponding to the desired camera from which to visualise an image
08 45 08 08 ::: 45 45 Mon. Mon. Mon. 09/11/2015 09/11/2015 09/11/2015
INFO SYSTEM
CAMERA PLACA / /PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Monitor settings.
DOOR 1
DOOR 2
DOOR 3 2
CAMERA 1
CAMERA 2
CAMERA DOOR 2 3
DOOR 4
CAMERA 4
Main menu.
The following screen will display the image from the selected camera with address 2, it will also indicate the selected camera 'CM-2' and the elapsed connection time. The connection will last for 30 seconds or until option is pressed. 00:30 CM-2
Screen settings: Scene, brightness, colour and monitor volume (see settings on pages 10-11). Take photo or record video manually. Video recording (Micro-SD card required). Activate door release 1. Activate door release 2. Start communication. End auto switch-on. (Return to the selection screen).
Continued overleaf
15
THERA GB2 MONITOR USER MENU Continued from the previous page.
2.1 Intercom (inner Broadcast): To access the Inner Broadcast function, press option “Intercom” . The following selection screen will be displayed. Press “Inner Broadcast”.
08 :: 45 45 08 Mon. Mon. 09/11/2015 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INNER DIFUSIÓN BROADCAST
INNER CALL
NAME LIST CALL
CALL GUARD UNIT VIGILANTE
Main menu. INFO SYSTEM
A tone on the monitor performing the broadcast will indicate that the function is active and the following communication screen will be displayed (the other monitors do not display a communication screen). It is now possible to talk and listen to the other monitors in the apartment from each of the monitors. Communication will last for one and a half minutes or until option is pressed from the monitor that has performed the broadcast function
During communication
Increase communication volume. Reduce communication volume. End communication. If a call is received from the door panel during the inner broadcast process, the intercom call will be cancelled. A melody in the apartment's monitors will play to indicate that a call is being made and an image will appear on the master monitor. To establish communication with the door panel, press button on any of the monitors. If a call is received from another apartment during the inner broadcast process, the intercom call will be cancelled. A melody in the apartment's monitors will play to indicate that a call is being made and the address of the apartment making the intercom call will appear (see “intercom calls between apartments” on page 17).
Continued overleaf
16
THERA GB2 MONITOR USER MENU Continued from the previous page.
2.2 Intercom calls within an apartment: To access the intercom calls within an apartment function, press option “Intercom”. The following selection screen will be displayed. Press “Inner call”.
08 :: 45 45 08 Mon. Mon. 09/11/2015 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INNER DIFUSIÓN BROADCAST
INNER CALL
NAME LIST CALL
CALL GUARD UNIT VIGILANTE
Main menu. INFO SYSTEM
The following call screen will appear and a melody in the other monitors of the apartment will play to indicate the presence of the intercom call. The call will end if it is not answered within 40 seconds or if option is pressed.
Making an intercom call
Redial. End call and return to the selection screen. Press button
or option
to accept the call and establish communication or press option
to reject it.
Receiving an intercom call
Recibe llamada intercomunicación Establish communication. End call. If the call is accepted, communication will last for 1 and a half minutes or until option
is pressed.
During communication
Recibe llamada intercomunicación
Increase communication volume. Reduce communication volume. End communication.
If a call is received from the door panel during the intercom process, the intercom call will be cancelled. A melody in the apartment's monitors will play to indicate that a call is being made and an image will appear on the master monitor. To establish communication with the door panel, press button on any of the monitors. If a call is received from another apartment during the intercom process, the intercom call will be cancelled. A melody in the apartment's monitors will play to indicate that a call is being made and the address of the apartment making the intercom call will appear (see “intercom calls between apartments” on page 17). Continued overleaf
17
THERA GB2 MONITOR USER MENU Continued from the previous page.
2.3 Intercom calls between apartments: To access the intercom calls between apartments function, press option “Intercom”. The following selection screen will be displayed. Press “Name List Call”. Selection screen
08 :: 45 45 08 Mon. Mon. 09/11/2015 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INNER DIFUSIÓN BROADCAST
INNER CALL
NAME LIST CALL
CALL GUARD UNIT VIGILANTE
INFO SYSTEM
The following apartment selection screen will be displayed. Press the apartment to be called. Then press option to make the call.
Apartment selection screen Name List
[ 00 ] Mr. Smith
Make the call.
[ 01 ] Mr. Carter
Edit name list.
[ 02 ] Mr. Bell [ 03 ] Mrs. Coleman
Scroll forwards in the phone book.
[ 04 ] Mrs. Lee
Scroll backwards in the phone book.
[ 05 ] Mrs. Kelly
Return to the selection screen.
The following call screen will be displayed indicating the address and name of the apartment to be called. In the called apartment the monitor(s) will emit a melody indicating an intercom call and display the address and name of the apartment making the call. The call will end if it is not answered within 40 seconds or if option is pressed.
Making an intercom call [ 01 ] Mr. Carter
Redial. End call and return to the selection screen. Press button
or option
to accept the call and establish communication or press option
to reject it.
Receiving an intercom call
Recibe llamada intercomunicación Establish communication. End call. Continued overleaf
18
THERA GB2 MONITOR USER MENU Continued from the previous page. If the call is accepted, communication will last for 1 and a half minutes or until option
is pressed.
During communication
Recibe llamada intercomunicación
Increase communication volume. Reduce communication volume. End communication.
If during an intercom call there is a call from the door panel to either apartment, the said intercom call will be cancelled. The monitor will emit a melody notifying the incoming call and the image will appear on the master monitor. To establish communication with the door panel press push button on the monitor. If there are slave monitors in the apartment, press push button on either of these.
Continued overleaf
19
THERA GB2 MONITOR USER MENU Continued from the previous page.
2.4 Calling the surveillance monitor: To access the building's surveillance monitor call function (if there is one), press option “Intercom”. The following selection screen will be displayed. Press “Call Guard Unit”.
Selection screen
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INNER DIFUSIÓN BROADCAST
INNER CALL
NAME LIST CALL
CALL GUARD UNIT VIGILANTE
INFO SYSTEM
The following call screen will be displayed and a melody will play, indicating the “GU” address of the surveillance monitor to be called. The call will end if it is not answered within 40 seconds or if option is pressed.
Making an intercom call GU
Redial. End call and return to the selection screen. Press button
or option
to accept the call and establish communication or press option
to reject it.
Receiving an intercom call [ 01 ] Mr. Carter
Recibe llamada intercomunicación Establish communication. End call. If the call is accepted, communication will last for 1 and a half minutes or until option
is pressed.
During communication
Recibe llamada intercomunicación
Increase communication volume. Reduce communication volume. End communication.
If an apartment receives a call from the door panel while calling or communicating with the surveillance monitor, the call to or communication with the surveillance monitor will be cancelled. The apartment's monitor will emit a melody notifying the call from the door panel and the image will appear on the master monitor. To establish communication with the door panel press push button on the monitor. If there are slave monitors in the apartment, press push button on either of these. Continued overleaf
20
THERA GB2 MONITOR USER MENU Continued from the previous page.
3.1 Viewing photos and videos of door panel calls/cameras and deleting photos and videos: Note: By default, the monitor enables photos to be taken. For the video option, a Micro-SD card is required. Use of this card cancels the photo option. To view photos and videos from calls/cameras, press “Playback”. The following selection screen will be displayed. Use options and to select the desired video. If the Micro-SD card is being used, the length of each video is 10 seconds. Press option to pause or play the video.
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
/ PLACA
Image: 001/002
INFO SYSTEM
2015 / 11 / 09
11 : 39 : 09
To delete photos and videos, use options and to select the photo or video to be deleted and then press option to bring up the following deletion screen. Press option to delete the selected photo or video or press option to exit without deleting and return to the previous screen.
/ PLACA
Image: 001/002
/ PLACA
2015 / 11 / 09
Press option
11 : 39 : 09
2015 / 11 / 09
11 : 39 : 09
to return to the main menu.
08 08 :: 45 45 Mon. Mon. 09/11/2015 09/11/2015
/ PLACA
Image: 001/001
Image: 001/002
2015 / 11 / 09
11 : 39 : 09
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INFO SYSTEM
Continued overleaf
21
THERA GB2 MONITOR USER MENU Continued from the previous page.
4.1 Viewing the call log: To view the call log, press “Call log”. The following screen will be displayed. Call Log 08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
DONO NOT MOLESTAR DISTRURB
DIVERT
PLAYBACK
LIGHT
01/02
09-11 12:24
PL-1
08-11 12:14
[01] Mr. Smith
08-11 12:10
[01] Mr. Smith
08-11 12:24
PL-1
08-11 12:10
PL-1
08-11 11:14
PL-1
CALL LOG
CLOSE
INFO SYSTEM
“Call log” screen description. Page 01 of a total of 02 pages is displayed. Call Log
01/02
09-11 12:24
PL-1
08-11 12:14
[01] Mr. Smith
08-11 12:10
[01] Mr. Smith
08-11 12:24
PL-1
08-11 12:10
PL-1
08-11 11:14
PL-1
Delete all call records. Show previous page. Show next page. Return to the main menu screen. Origin of call and/or who was called. Time of call. Day-month of call. Photo or video of missed call (door panels only). Down arrow indicates incoming call (red: not answered). Up arrow indicates outgoing call
If a door panel call record is pressed. Record selected. Call Log
01/02
09-11 12:24
PL-1
08-11 12:14
[01] Mr. Smith
08-11 12:10
[01] Mr. Smith
08-11 12:24
PL-1
08-11 12:10
PL-1
08-11 11:14
PL-1
Display captured photo or video (displayed on “Playback” screen). Delete selected record. Show previous page. Show next page. Return to the main menu screen.
If an intercom call from an apartment record is pressed. Record selected. Call Log
01/02
09-11 12:24
PL-1
08-11 12:14
[01] Mr. Smith
08-11 12:10
[01] Mr. Smith
08-11 12:24
PL-1
08-11 12:10
PL-1
08-11 11:14
PL-1
Call the apartment of the selected record. Delete selected record. Show previous page. Show next page. Return to the main menu screen.
Continued overleaf
22
THERA GB2 MONITOR USER MENU Continued from the previous page.
5.1 Do not disturb mode. To access the “Do not disturb” mode functions, press option displayed.
. The following selection screen will be
Do Not Disturb 08 : 45 Mon. 09/11/2015
Normal CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
For 1 Hour For 8 Hour Always
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INFO SYSTEM
To activate the do not disturb mode functions, press option “Always”. Icon will be activated in the pressed option and icon will be displayed on the main menu indicating that the function has been activated. The monitor will not receive door panel nor intercom calls. To exit do not disturb mode, press option “Normal” and icon will disappear from the main menu screen. Do Not Disturb
Normal For 1 Hour
08 :: 45 45 08 Mon. Mon. 09/11/2015 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
For 8 Hour Always
INFO SYSTEM
To activate do not disturb for “1 Hour” mode, press option “1 Hour”. Icon will be activated in the pressed option (the remaining time appears on the screen) and icon will be displayed on the main menu screen indicating that the function has been activated. The monitor will not receive door panel nor intercom calls. Do not disturb mode will be activated for 1 hour or until option “Normal” is pressed and icon is no longer displayed. Do Not Disturb
Normal For 1 Hour
08 :: 45 45 08 Mon. Mon. 09/11/2015 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
For 8 Hour Always Time Remaining: 00 : 59 : 59 INFO SYSTEM
To activate do not disturb for “8 Hours” mode, press option “8 Hours”. Icon will be activated in the pressed option (the remaining time appears on the screen) and icon will be displayed on the main menu screen indicating that the function has been activated. The monitor will not receive door panel nor intercom calls. Do not disturb mode will be activated for 8 hours or until option “Normal” is pressed and icon is no longer displayed. Do Not Disturb
Normal For 1 Hour
08 :: 45 45 08 Mon. Mon. 09/11/2015 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
For 8 Hour Always Time Remaining: 08 : 59 : 59 INFO SYSTEM
Continued overleaf
23
THERA GB2 MONITOR USER MENU Continued from the previous page.
6.1 Divert call mode (GSM-GB2 module required): To access the divert call functions, press option “Divert”. The following selection screen will be displayed. Press option “1), 2) or 3)” to edit up to 3 #xed or mobile telephone numbers to which the call from the door panel will be diverted. Selection screen Divert Options 08 : 45 Mon. 09/11/2015
No divert CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
If No Answer Divert calls 1) -
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
2) 3) -
INFO SYSTEM
The following telephone number screen will be displayed. Enter the telephone number with the numeric buttons. To save the number press “OK” and, on the selection screen, press . To exit, press . To exit without saving, press and, on the selection screen, press . To enter a 2nd and 3rd telephone number, press option “2), 3)” and repeat the same steps as in option “1)”.
Selection screen TEL NUMBER 1
Divert Options
6191718XX No divert If No Answer Divert calls 1) -6191718XX 2) 3) -
The following selection screen will be displayed with the edited number(s). Then select the required divert option. Icon will be activated in the required option and icon will be displayed on the main menu screen indicating that the function has been activated. To exit divert mode, press option “No divert” and icon will disappear from the main menu screen.
Selection screen Door panel call mode, no divert. Divert Options
Door panel call mode, divert if not answered within 35 seconds.
No divert
Door panel call mode, immediate divert.
If No Answer
Check status of GSM-GB2 module.
Divert calls 1) 6191718XX
Press to send SMS to telephone numbers 1) and 2).
2) 6292324XX
Save telephone numbers added.
3) 9764865XX
Return to the main menu screen.
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Divert mode activated. INFO SYSTEM
Continued overleaf
24
THERA GB2 MONITOR USER MENU Continued from the previous page.
7.1 Exiting the user menu function: To exit the monitor's user menu function, press
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
.
Monitor in standby
INFO SYSTEM
8.1 Settings. To access the setup functions, press
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
. The following settings screen will be displayed.
INFO SYSTEM
Settings Sounds Date & Time Language More... About Home
Continued overleaf
25
THERA GB2 MONITOR USER MENU
Continued from the previous page. 8.1.1 To access the ringtone and volume settings, press “Sounds”. The following settings screen will be displayed (default settings: Door ringtone “19”, Intercom “01”, Door bell “03” and Alert “04”. Volume day “06” and night “03”). 19 TelRing
Ring Tune
Settings Door 1
Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Door 2
19
Door 3
19
19
Door 4
Intercom
19
01
TIMBRE Bell
03
Alert
04
Date & Time Language Volume
More... About Home
Door Ring Mode
Day
06
United
Night
03
Separate
To change the door panel ringtones, press option “Door 1” and then press or to select the melody. Repeat the process to change the ringtones for the other call types. To select a separate ringtone for each of the 4 doors or a single ringtone for all 4 doors, press option “United” or “Separate”. Quick access to other settings.
Door 1
Door 2
19
Select from 20 melodies.
19 TelRing
Ring Tune Door 3
19
19
Door 4
19
Intercom
01
TIMBRE Bell
03
Alert
04
Call type. Call ringtone. Set call volume “Day”.
Volume
Door Ring Mode
Day
06
United
Night
03
Separate
Select a single ringtone for all 4 doors. Select separate ringtones for each of the 4 doors. Set call volume “Night”.
To change the volume level in “Day” and “Night” mode for the different types of ringtones, press option of the corresponding mode. Press option to return to the main menu page. 19 TelRing
Ring Tune Door 1
Door 2
19
or
Door 3
19
19
Door 4
19
Volume
Intercom
01
TIMBRE Bell
03
Alert
04
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Door Ring Mode
Day
06
United
Night
03
Separate
INFO SYSTEM
To continue with the setup functions, press
. The following settings screen will be displayed.
Settings 08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Date & Time Language DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
More... About
INFO SYSTEM
Home
Continued overleaf
26
THERA GB2 MONITOR USER MENU Continued from the previous page. 8.1.2 To access the time and date settings, press option “Date & Time”. The following settings screen will be displayed.
Date & Time Fecha y hora
Settings Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Date & Time Language More...
Sync Sincronizar
About Sync From System Clock Sincronizar desde reloj sistema
Home
To change the time and date, press the selection #eld to change “2015” and then press option values. Repeat the process with the remaining selection #elds.
or
to set the
Quick access to other settings. Press to accept and save the changed values.
Date & Time
Selection #elds (year - month - day). Selection #elds (hours: minutes: seconds). Change the selected value. Sync
No function.
Sync From System Clock
To accept and save the changed values, press
. Then press
to return to the main menu page.
Date & Time
08 : 45 Mon. 09/11/2015
Sync
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Sync From System Clock INFO SYSTEM
To continue with the setup functions, press
. The following settings screen will be displayed.
Settings 08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Date & Time Language DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
More... About
INFO SYSTEM
Home
Continued overleaf
27
THERA GB2 MONITOR USER MENU Continued from the previous page. 8.1.3 To access the language settings, press option “Language”. The following settings screen will be displayed.
Language
Settings
English
Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
Español
Date & Time
Francais
Language More...
DONO NOT MOLESTAR DISTRURB
Nederlands DIVERT
LIGHT
CLOSE
Portugues
About Home
To change the language, press the required language (default setting: Spanish). Quick access to other settings. Language
Press to accept and save the changed values.
19 TelRing
English Español Francais Nederlands Portugues
To accept and save the selected language, press
. Then press
to return to the main menu page.
Language
English
08 : 45 Mon. 09/11/2015
Español
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Francais Nederlands Portugues INFO SYSTEM
To continue with the setup functions, press
. The following settings screen will be displayed.
Settings 08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Date & Time Language DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
More... About
INFO SYSTEM
Home
Continued overleaf
28
THERA GB2 MONITOR USER MENU Continued from the previous page.
8.1.4 To access the rename door/camera and auto switch-on time settings, press option “More”. The following settings screen will be displayed. Door Rename
Camera Rename
Settings Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
Date & Time Language More...
DONO NOT MOLESTAR DISTRURB
DIVERT
CLOSE
LIGHT
PL - 1
CM - 1
PL - 2
CM - 2
PL - 3
CM - 3
PL - 4
CM - 4
Autoswitch On time
About 30 sec
Home
To rename a door/camera, press on the selection #eld for that door/camera. The following text editing screen will be displayed. Using the alphanumeric buttons, enter the new text for the door/camera. To save, press “OK”. To exit without saving, press . From the selection screen, repeat the steps to rename the doors/cameras in the other selection #elds. Door Rename
Camera Rename
PL - 1 PL - 1
CM - 1
PL - 2
CM - 2
PL - 3
CM - 3
PL - 4
CM - 4
Autoswitch On time
, .
30 sec
To set the auto switch-on time, press option menu page. Door Rename
or
(default setting: 30 sec.). Then press
to return to the main
Camera Rename
PL - 1
CM - 1
PL - 2
CM - 2
PL - 3
CM - 3
PL - 4
CM - 4
08 : 45 Mon. 09/11/2015
Autoswitch On time
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
30 sec INFO SYSTEM
To continue with the setup functions, press option
. The following settings screen will be displayed.
Settings 08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
Date & Time Language DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
More... About
INFO SYSTEM
Home
Continued overleaf
29
THERA GB2 MONITOR USER MENU Continued from the previous page. 8.1.5 To access the default setup, Micro-SD card and installer menu settings, press option “About” or page 31). The following selection and monitor information screen will be displayed.
(see
Selection screen About
Settings Sounds
CAMERA / PLACA
INTERCOM
PLAYBACK
Date & Time Language More...
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
About Home
Local Address
00.00
Video standard
AUTO
System Version
01.01.06
CALL LOG
Display Driver
1.6
Font
1.2
UI
1.1
CLOSE
To access the default setup function, press option . The following screen will be displayed. Press option to con#rm and retain the default settings in “8.1 Settings” (see pages 25, 27 and 28) or press option to return to the selection screen.
Selection screen Acerca About de Dirección Local Address
00.00
Video standard
AUTO
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
Restore To Default?
To access the Micro-SD card function, press option . The following information and selection screen will be displayed. Note that the monitor has a $ash memory for photos but, if video recording is required, a Micro-SD card must be inserted. Micro-SD card must be inserted. Selection screen Driver standard Fuente pantalla 1.2 Video Interface desistema usuario de 1.6 1.1 AUTO Dirección Versión del 00.00 01.01.04 Acerca
About
Información Memo Information de memoria
Local Address
00.00
Video standard
AUTO
System Version
01.01.06
Display Driver
1.6
SD Tarjeta CardSD
004G
Video Capacidad Capacity total videos 0227 0227 Capacidad Video Usage utilizada
0021 0021
Memoria Flash Flash
Font
1.2
Capacidad Image Capacity total fotos
0118 0118
UI
1.1
Image Capacidad Usage utilizada
0000 0000
To format the Micro-SD card, press option . The following screen will be displayed. Press option the Micro-SD card or option to return to the selection screen. Micro-SD card must be inserted.
to format
Información Memo Information de memoria SD Tarjeta CardSD
004G
Video Capacidad Capacity total videos 0227 0227 Video Capacidad Usage utilizada
Format SD Card And Restart?
0021 0021
Flash Memoria Flash Capacidad Image Capacity total fotos
0118 0118
Image Capacidad Usage utilizada
0000 0000
Continued overleaf
30
THERA GB2 MONITOR USER MENU Continued from the previous page. To copy photos from the flash memory to the Micro-SD card, press option . The following screen will be displayed. Press option to copy photos to the Micro-SD card or option to return to the selection screen. Micro-SD card must be inserted. Información Memo Information de Información de memoria memoria SD Tarjeta CardSD Tarjeta SD
004G 004G Copy Pictures To SD?
Video Capacidad Capacity total 0227 Capacidad total videos videos 0227 0227 Video Capacidad Usage utilizada Capacidad utilizada
0021 0021 0021
Flash Memoria Memoria Flash Flash Image Capacidad Capacity total Capacidad total fotos fotos
0118 0118 0118
Image Capacidad Usage utilizada Capacidad utilizada
0010 0000 0010
To exit the card selection and information screen, press “About” screen will be displayed. Información Memo Information de Información de memoria memoria SD Tarjeta CardSD Tarjeta SD
004G 004G
Video Capacidad Capacity total 0227 Capacidad total videos videos 0227 0227 Video Capacidad Usage utilizada Capacidad utilizada
0021 0021 0021
Flash Memoria Memoria Flash Flash
. The following monitor selection and information
Acerca de
About
Local Address Dirección
00.0000.00
standard VideoVideo standard System Version Versión del sistema
AUTOAUTO 01.01.06 01.01.04
Driver DriverDisplay pantalla
1.6
1.6
Image Capacidad Capacity total Capacidad total fotos fotos
0118 0118 0118
Font Fuente
1.2
1.2
Image Capacidad Usage utilizada Capacidad utilizada
0010 0000 0010
UI de usuario Interface
1.1 1.1
To access the installer menu, press button
for 3 seconds. The following setup screen will be displayed.
Driver standard Fuente pantalla 1.2 Video Interface desistema usuario de 1.6 1.1 AUTO Dirección Versión del 00.00 01.01.04 Acerca
About
INSTALLER SETUP
_
Local Address
00.00
Video standard
AUTO
System Version
01.01.06
Display Driver
1.6
Font
1.2
UI
1.1
Then enter the function code with the numeric buttons. Con#rm the function code entered by pressing option “OK”. Press option to exit and return to the monitor's selection and information screen. INSTALLER SETUP
About
8000 Local Address
00.00
Video standard
AUTO
System Version
01.01.06
Display Driver
1.6
Font
1.2
UI
1.1
Continued overleaf
31
THERA GB2 MONITOR USER MENU Continued from the previous page. Function codes (installer):
* [8000]: Master monitor (factory).
* [8001]to [8003]: Slave monitor 1 to 3.
[8004]: Surveillance monitor. [9015]: Intercom enabled (factory)
[8005]: Without surveillance monitor (factory). [9016]: Intercom disabled.
* Each apartment must have only one master unit: Any further units in the apartment must be con#gured as slaves. To exit the monitor's selection and information screen, press
. The menu screen will be displayed.
Main menu screen
Selection screen Acerca About de Dirección Local Address
00.00
Video standard
AUTO
08 : 45 Mon. 09/11/2015
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INFO SYSTEM
For quick access to the default setup, Micro-SD card and installer menu settings, press option . The following monitor selection and information screen will be displayed (follow the steps contained on pages 29, 30 and 31 to adjust the settings). To exit and return to the menu screen, press .
Main menu screen
Selection screen Acerca About de
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
DONO NOT MOLESTAR DISTRURB
INTERCOM
DIVERT
PLAYBACK
LIGHT
Dirección Local Address
00.00
Video standard
AUTO
CALL LOG
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
CLOSE
INFO SYSTEM
To exit the monitor's user menu function, press
.
Monitor in standby
Main menu screen
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INFO SYSTEM
CLEANING THE MONITOR - Do not use dissolvents, detergents or cleaning products that contain acids, vinegar or abrasive components. - Use a soft, damp cloth (not wet) that does leave lint behind. - Always wipe the monitor in the same direction, from top to bottom. - After cleaning the monitor remove any moisture using a soft, dry cloth that doesn't leave lint behind.
Sistemas de comunicación S.A.
[email protected] www.golmar.es
Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis . Golmar reserves the right to make any modifications without prior notice.
33
THERA GB2 MONITOR USER MENU (ANNEX) To change the “Day” mode start and finish time: The monitor's ringtone is louder during the time set as day mode (default setting of 06:00 to 18:00). Step 1: Set Dip1 of the monitor's con#guration dip switch to ON.
ON 1
L1 L2
DIP 2
3
4
5
6
ON 1
DIP 2
3
4
5
6
Step 2: To access the menu, the monitor must be in standby. Then press on the screen or press menu button main menu options screen will be displayed. Monitor in standby Menu screen
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
. The
INFO SYSTEM
Then press
. The following selection and information screen will be displayed. Menu screen
Selection and information screen Acerca About de
08 : 45 Mon. 09/11/2015
CAMERA / PLACA
DONO NOT MOLESTAR DISTRURB
INTERCOM
PLAYBACK
DIVERT
LIGHT
Dirección Local Address
00.00
Video standard
AUTO
CALL LOG
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
CLOSE
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
INFO SYSTEM
To access the installer menu, press button for 3 seconds. The following installer screen will be displayed. Press button again for 3 seconds. The installer screen will be displayed again. Function codes of more than 4 digits can be entered on this #nal screen. Selection and information screen Installer screen INSTALLER SETUP
Acerca About de
_
Dirección Local Address
00.00
Video standard
AUTO
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
Continued overleaf
34
THERA GB2 MONITOR Continued from the previous page.
Step 3: Then enter the function code with the alphanumeric buttons. Con#rm the function code entered by pressing option “OK”. Press option to exit and return to the monitor's selection and information screen. Installer screen Selection and information screen INSTALLER SETUP
Acerca About de
1#0#62#2#0#07,15# Dirección Local Address
00.00
Video standard
AUTO
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
Function code: To set day mode to start at 07:00 in the morning and #nish at 21:00 at night, enter the following code (with the hours in hexadecimal): 1#0#62#2#0#07,15# Day mode #nish time (in hexadecimal). Day mode start time (in hexadecimal). Decimal time to hexadecimal time conversion table: Decimal 01 02 03 04 05 06
Hexadecimal 01 02 03 04 05 06
Decimal 07 08 09 10 11 12
Hexadecimal 07 08 09 0a 0b 0c
Decimal Hexadecimal 13 0d 14 0e 15 0f 16 10 17 11 18 12
Decimal 19 20 21 22 23 24
Hexadecimal 13 14 15 16 17 18
Important: If the function code contains letters, enter them in lowercase. Step 4:To exit the monitor's selection and information screen, press option
. The menu screen will be displayed.
Selection and information screen Menu screen
Acerca About de 08 : 45 Mon. 09/11/2015
Dirección Local Address
00.00
Video standard
AUTO
Versión Version del sistema System
01.01.04 01.01.06
Driver pantalla Display Driver
1.6
Fuente Font
1.2
Interface de usuario UI
1.1 1.1
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE
INFO SYSTEM
Then press option
to exit the monitor's user menu function.
Menu screen
08 : 45 Mon. 09/11/2015
INFO SYSTEM
Monitor in standby
CAMERA / PLACA
INTERCOM
PLAYBACK
CALL LOG
DONO NOT MOLESTAR DISTRURB
DIVERT
LIGHT
CLOSE