Transcript
TTL to Fiber Optic Modems 05/24/16
USA & International Headquarters 1101 N. Raddant Road Batavia, IL 60510 Phone: (630) 761-3640 Fax: (630) 761-3644 Web Site: http://www.sitech-bitdriver.com ©2016 S.I. Tech, Inc. All Copy and Images
S.I.TECH
TTL PRODUCTS
S.I. Tech Inc., Batavia, IL 60510 Phone: (630) 761-3640 Fax: (630) 761-3644 Web Site: http://www.sitech-bitdriver.com
1
S.I.TECH TTL PRODUCTS 1. Point to Point: HOST COMPUTER TTL PORT
TTL PORT
FIBER OPTIC S.I.TECH 2856
R
T
T
R
TTL PORT S.I.TECH 2856
S.I.TECH 2856
TTL PORT
TTL PORT
FIBER OPTIC R
T
T
R
S.I.TECH 2856
S.I.TECH 2856
CONTROLLER 1
TTL PORT
FIBER OPTIC R
T
T
R
S.I.TECH 2856
CONTROLLER 2
CONTROLLER 3
2. Multiplexer:
DTE1
HOST COMPUTER
4 or 8 Channel
TTL
S.I.Tech F.O. MUX 2454/2458 F.O.MUX
Fiber Optic T T
R
R
DTE2 S.I.Tech F.O. MUX 2454/2458 F.O.MUX
TTL
4 or 8 Channel
4 to 1 or 8 to 1 cable
DTE7
4 to 1 or 8 to 1 cable
DTE8
2
S.I. Tech Inc., Batavia, IL 60510 Phone: (630) 761-3640 Fax: (630) 761-3644 Web Site: http://www.sitech-bitdriver.com
S.I.TECH
S.I. Tech Inc., Batavia, IL 60510 Phone: (630) 761-3640 Fax: (630) 761-3644 Web Site: http://www.sitech-bitdriver.com
3
S.I.TECH TTL TO FIBER OPTIC BIT-DRIVERS® DIP MODEL 2805
DIP MODEL 2806
2816
2817
2820
Metal 40 pin DIP configuration Optical-to-TTL Bit-Driver® Receiver Data Rate is DC to 20 Mbps NRZ Connection is by solder pads or DIP socket Package size is 2.0x1.12x0.37 inches SMA Connector
One way (T & R) or Two way (Full Duplex) High Speed TTL Miniature Units Flange Mounting Data rate from 100 Kbps to 50 Mbps Multimode or Single mode Rack Mount Option Available
One way (T & R) or Two way (Full Duplex) TTL Miniature Units Flange Mounting Data rate to 20 Mbps Multimode or Single mode 5VDC or 12VDC Power
Consist of two (2) 850nm or 1310nm transmitters, or 850nm and 1310nm TR Miniature Units Flange Mounting Data rate to 50 Mbps Multimode or Single mode
2821
4
Metal 24 pin DIP configuration TTL-to-Optical Bit-Driver® Transmitter Data Rate is DC to 20 Mbps NRZ Connection is by solder pads or DIP socket Package size is 1.2x0.75x0.37 inches SMA Connector
Consist of two (2) 850nm or 1310nm transmitters, or 850nm and 1310nm REC Miniature Units Flange Mounting Data rate to 50 Mbps Multimode or Single mode
S.I. Tech Inc., Batavia, IL 60510 Phone: (630) 761-3640 Fax: (630) 761-3644 Web Site: http://www.sitech-bitdriver.com
S.I.TECH 2856
2860
2865
Asynchronous Simplex or Full Duplex Optical Bit-Driver® Max Data Rate is 20 Mbps Supports 50 or 75 ohm coax Power, Transmit Data, and Receive Data LED indicators
4 CH TTL or RS-422 Data rate to 20 Mbps Triax and BNC Connectors 1U high rack 19” Military Systems, Instrumentation
Unmounted Circuit Card configuration TTL-to-Optical BitDriver® Transmitter-Receiver. Data Rate is DC to 20Mbps NRZ Connection is to solder pads in 16 pin DIP configuration Card size is 3¾ x 3 inches with 2.4 x 2.55 inch mounting centers. Multimode is standard, Single mode optional
2867
3 Channel RS422 and TTL Switchable Input to Fiber Optic Bit Driver with Continuous RS-422 and TTL Outputs Up to 20 Mbps Data rate 1U High Case Multimode or Single mode Uses BNC and Terminal Blocks Used in Military System
TTL TO FIBER OPTIC MULTIPLEXERS 2006 (See RS232 Section)
TTL is an Optional Interface on Model 2006
S.I. Tech Inc., Batavia, IL 60510 Phone: (630) 761-3640 Fax: (630) 761-3644 Web Site: http://www.sitech-bitdriver.com
5
Model 2805 TR/2806 REC Fiber Optic Transmitter/Receiver Pair
S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-Drivers. OPERATING DISTANCE FOR FIBER OPTIC CABLE Fiber Size Attenuation Distance Distance (Microns) dB/Km Meters Feet 62.5 50
SYSTEM
TYPICAL APPLICATION T
R
R
DTE
Transmitter 2805 Receiver 2806 DCE
Computer CPU Process Equipment
22
21
20
19
5
6
18
17
7
8
16
15
14
N U O R G
13
12 U
N
D
11 O
70Ω
70Ω
10
R
IN PU T TE #1 R M IN A O T PT IO IO N N IN PU T #2
9
G
4
3
R ES L IS OA TO D R
2
1
R ES L IS OA TO D R G R O U N D
75Ω
35Ω
LED
1KΩ
140Ω
23
D
R ES L IS OA TO D R LE D C AT H O G D R E O U N D
c
c
S.I.TECH 2805 TRANSMITTER 24
TTL Signal
DTE: Data Terminal Equipment DCE: Data Communication Equipment
Computer CPU Process Controller
OPTICAL TRANSMITTER Output Power at 100 mA LED Current: 10 microwatts (-20 dBm) into 50 micron fiber. Output power is pin selectable over a 10 dB range Wavelength: 820 nanometers Emitter Type: LED Optical Connector: SMA compatible metal receptacle
PREAMP
PIN DIODE
R
O
U
N
D
21 22 23 24 25
AMP
COMPAMP
3
R
O
S
O
T U O
T
4
U
5
O
V -5
20 19 18 17 16
2
1
36 37 38 39 40 + O 5 D UT V IS P AB U G LE T R O U N D
G
R O +v U N cc D
S.I.TECH 2806 RECEIVER
G
OPTICAL RECEIVER Wavelength: 670 to 950 nanometers, 820 to 900 nanometers is optimum Minimum Sensitivity: (BER ≤ 10 -9 ) 1 microwatt (-30 dBm) @ 820 nanometers Maximum Sensitivity: 10 microwatts Minimum Optical Risetime required: 0.25 microseconds Optical Connector: SMA compatible metal receptacle Operating Temperature: 0 oC to 50 oC Size: TR2805 (24 pin DIP) 1.2" X 0.75" X 0.37 " (3X1.9X0.94 cm) REC 2806 (40 pin DIP) 2.0" X 1.12 " X 0.37" (5X2.8X0.94 cm) Hybrid circuit in an all metal DIP Weight: TR/REC pair - 0.25 lb (100 grams) Stand Alone Version: Model 2856 with power supply and Bit-Driver enclosure 2817-T/R Mini Version P.C.Board Version: S.I.Tech 2865
Transmitter 2805 Receiver 2806 DCE
TTL Signal
FIBER T CABLE
vc
ELECTRICAL SIGNAL INPUT/OUTPUT FOR TRANSMITTER AND RECEIVER Format: TTL Connector: Solder pads or DIP socket Duty Cycle: 0 to 100% Minimum Pulse Width: 50 nanoseconds Data Rate: DC to 20 Mbps NRZ Input impedance: TTL, optional 75 ohm TTL levels Output Impedance: Standard TTL logic output (sink 16 milliamps, source 400 microamps)
Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
vc
Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable Typical Bit Error Rate: Better than 10 -9
6600 6600
2000 2000
4.0 3.0
D O RIV U E TP R U T
2806
75Ω
S.I.Tech
TE R M IN O AT PT IO IO N N R ES L IS OA TO D R
2805
Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application.
5V A O NA U LO TP U G T
S.I.Tech
TRANSMISSION LINE INTERFACE
+
DUAL IN-LINE PACKAGE FOR PC BOARD MOUNT
Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice.
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. ©2005 S.I. Tech, Inc.
Model 2816-T/R
TTL OUT
TRANSMISSION LINE INTERFACE Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application.
MODEL 2816-T/R
BIT-DRIVER
TTL IN
Tx
PWR Rx 8-15VDC
High Speed TTL to Fiber Optic Transmitter/Receiver
S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-Drivers.
Operating Distance for Fiber Optic Cable SYSTEM
Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable or 10 Km using single mode fiber Typical Bit Error Rate: Better than 10 -9
ELECTRICAL SIGNAL INPUT/OUTPUT FOR TRANSMITTER AND RECEIVER Format: TTL Connector: BNC Data Rate: 100 Kbps - 50 Mbps Input Impedance: TTL levels 10 KΩ Output Impedance: TTL levels into 50Ω Input Power: 8 to 14VDC 250mA Max. Optional 5VDC@150mA OPTICAL TRANSMITTER LED Current: 30 microwatts (-15 dBm) into 62.5 micron fiber Wavelength: 820 nanometers (1300 nm option) Emitter Type: LED Optical Connector: ST OPTICAL RECEIVER Wavelength: 820 nm (1300 & 1550 nm option) Minimum Sensitivity: (BER ≤ 10 -9 ) 3 microwatt (-25 dBm) @ 820 nanometers Optical Connector: ST Operating Temperature: 0 oC to 50 oC (optional extended temp for multimode) Size: 5.125" X 2.125" X 1.0" (13.00 X 5.40 X 2.54 cm) Weight: 6 oz (170 Grams)
Fiber Size (Microns) 50 62.5 10 SM*
Attenuation Distance Distance (dB/Km) (Meters) (Feet) Wavelength (nm) Wavelength (nm) Wavelength (nm) 850 1300 1550 850 1300 1550 850 1300 1550 2000 6000 6600 20000 3.0 1.0 2000 6000 6600 20000 4.0 1.0 - 10000 12000 - 33000 40000 0.35 0.25
* Single mode (1300 and 1550 nm) option Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
Power Consumption 50Ω TTL Load
50% Duty Cycle No TTL Load 2816 TR 2816 T 2816 R
130 mA X 110 mA
100 mA 60 mA 50 mA
ORDERING INFORMATION Model Numbers 2816 TTL to Fiber, Transmitter/Receiver, Multimode, ST Connector 2816-SM TTL to Fiber, Transmitter/Receiver, Single mode, ST Connector 2816-T TTL to Fiber, Transmitter, Multimode, ST Connector 2816-R TTL to Fiber, Receiver, Multimode, ST Connector 2816-T-SM TTL to Fiber, Transmitter, Single mode, ST Connector, 1300nm 2816-R-SM TTL to Fiber, Receiver, Single mode, ST Connector, 1300nm 2816-T-SM(15) TTL to Fiber, Transmitter, Single Mode 1550 nm 2816-R-SM(15) TTL to Fiber, Receiver, Single Mode 1550 nm Notes: 1. Power Supply #2121 (110VAC to 9 VDC) is recommended for all models-USA 2. Optional Power Supply #2164 is for 230VAC applications 3. Optional Power Supply #2166 for 5VDC
TYPICAL APPLICATION
Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice. UL R
Computer CPU Process Controller Instrument
TTL Signal
S.I.Tech 2816-T/R
T R
FIBER CABLE
R T
S.I.Tech 2816-T/R
TTL Computer CPU Signal
Process Controller Instrument
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2011 S.I. Tech, Inc.
Model 2816-16R-T & 2816-16R-R High Speed TTL to Fiber Optic Transmitter/Receiver - 16 Channel TRANSMISSION LINE INTERFACE Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application. S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-Drivers. S.I.Tech #2816-16R-T & R can be used as 16 TTL channels with 16 fibers or using WDM, 8 fibers can be used. SYSTEM Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable or 10 Km using single mode fiber on each channel Typical Bit Error Rate: Better than 10-9 ELECTRICAL SIGNAL INPUT/OUTPUT FOR TRANSMITTER AND RECEIVER Format: TTL - 16 Channel Connector: BNC Data Rate: 100 Kbps - 50 Mbps Input Impedance: TTL levels 10 KΩ Output Impedance: TTL levels into 50Ω Input Power: 110/230VAC, 12W
OPTICAL TRANSMITTER LED Current: 30 microwatts (-15 dBm) into 62.5 micron fiber Wavelength: 820 nanometers (1300 nm option) Emitter Type: LED Optical Connector: ST OPTICAL RECEIVER Wavelength: 820 nm (1300 & 1550 nm option) Minimum Sensitivity: (BER ≤ 10 -9 ) 3 microwatt (-25 dBm) @ 820 nanometers Optical Connector: ST Operating Temperature: 0 oC to 50 oC (optional extended temp for multimode) Size: 17”W X 3.50”H X 7.5”D (43.2 X 8.6 X 19.0 cm) Weight: 6 lbs. (3KG)
Operating Distance for Fiber Optic Cable Fiber Size (Microns) 50 62.5 10 SM*
Attenuation Distance Distance (dB/Km) (Meters) (Feet) Wavelength (nm) Wavelength (nm) Wavelength (nm) 850 1300 1550 850 1300 1550 850 1300 1550 2000 6000 6600 20000 3.0 1.0 2000 6000 6600 20000 4.0 1.0 - 10000 12000 - 33000 40000 0.35 0.25
* Single mode (1300 and 1550 nm) option Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection. WDMs: S.I.Tech #8513 for Multimode. S.I.Tech #1315 for Single mode.
Power Consumption/Channel 50% Duty Cycle
No TTL Load
50Ω TTL Load
2816 T 2816 R
60 mA 50 mA
X 110 mA
ORDERING INFORMATION - RELATED PRODUCTS Model Numbers 2816 2816-SM 2816-T 2816-R 2816-T-SM 2816-R-SM 2816-T-SM(15) 2816-R-SM(15) 2820 2821
TTL to Fiber, Transmitter/Receiver, Multimode, ST Connector TTL to Fiber, Transmitter/Receiver, Single mode, ST Connector TTL to Fiber, Transmitter, Multimode, ST Connector TTL to Fiber, Receiver, Multimode, ST Connector TTL to Fiber, Transmitter, Single mode, ST Connector, 1300nm TTL to Fiber, Receiver, Single mode, ST Connector, 1300nm TTL to Fiber, Transmitter, Single Mode 1550 nm TTL to Fiber, Receiver, Single Mode 1550 nm TTL to Fiber, 2CH transmitter TTL to Fiber, 2CH Receiver
Notes: 1. Power Supply #2121 (110VAC to 9 VDC) is recommended for all models-USA 2. Optional Power Supply #2164 is for 230VAC applications 3. Optional Power Supply #2166 for 5VDC
TYPICAL APPLICATION
Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice.
Computer CPU Process Controller Instrument
16 TTL Signals
16 TTL Signals
16 Fibers S.I.Tech 2816-16R T
S.I.Tech 2816-16R R
Computer CPU Process Controller Instrument
UL R
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2012 S.I. Tech, Inc.
Model 2817-T/R
TTL OUT
MODEL 2817-T/R
BIT-DRIVER
TTL IN
Tx
PWR Rx 8-15VDC
TTL to Fiber Optic Transmitter/Receiver
SYSTEM Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable or 10 Km using single mode fiber Typical Bit Error Rate: Better than 10 -9
ELECTRICAL SIGNAL INPUT/OUTPUT FOR TRANSMITTER AND RECEIVER Format: TTL Connector: BNC Data Rate: Up to 20Mbps Input Impedance: TTL levels 10 KΩ Output Impedance: TTL levels into 50Ω Input Power: 8 to 15VDC 250mA Max. Optional 5VDC@150mA
TRANSMISSION LINE INTERFACE Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application. S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-Drivers.
OPTICAL TRANSMITTER LED Current: 30 microwatts (-15 dBm) into 62.5 micron fiber Wavelength: 820 nanometers (1300 nm option) Emitter Type: LED Optical Connector: ST
Operating Distance for Fiber Optic Cable Fiber Size (Microns) 50 62.5 10 SM*
Attenuation Distance Distance (dB/Km) (Meters) (Feet) Wavelength (nm) Wavelength (nm) Wavelength (nm) 850 1300 1550 850 1300 1550 850 1300 1550 2000 6000 6600 20000 3.0 1.0 2000 6000 6600 20000 4.0 1.0 - 10000 12000 - 33000 40000 0.35 0.25
* Single mode (1300 and 1550 nm) option Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
ORDERING INFORMATION OPTICAL RECEIVER Wavelength: 820 nm (1300 & 1550 nm option) Minimum Sensitivity: (BER ≤ 10 -9 ) 3 microwatt (-25 dBm) @ 820 nanometers Maximum Sensitivity: 10 microwatts Optical Connector: ST Operating Temperature: 0 oC to 50 oC (optional extended temp for multimode) Storage Temperature: -40 - 80 oC Relative Humidity: 10 to 95% Non-Condensation Size: 5.125" X 2.125" X 1.0" (13.00 X 5.40 X 2.54 cm) Card Version: 2317 Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice. UL
Model Numbers 2817 TTL to Fiber, Transmitter/Receiver, Multimode, ST Connector 2817-SM TTL to Fiber, Transmitter/Receiver, Single mode, ST Connector 2817-T TTL to Fiber, Transmitter, Multimode, ST Connector 2817-R TTL to Fiber, Receiver, Multimode, ST Connector 2817-T-SM TTL to Fiber, Transmitter, Single mode, ST Connector, 1300nm 2817-R-SM TTL to Fiber, Receiver, Single mode, ST Connector, 1300nm 2817-T-SM(15) TTL to Fiber, Transmitter, Single Mode 1550 nm 2817-R-SM(15) TTL to Fiber, Receiver, Single Mode 1550 nm Notes: 1. Power Supply #2121 (110VAC to 9 VDC) is recommended for all models-USA 2. Optional Power Supply #2164 is for 230VAC applications 3. Optional Power Supply #2166 for 5VDC
TYPICAL APPLICATION Computer CPU Process Controller Instrument
TTL Signal
S.I.Tech 2817-T/R
T R
FIBER CABLE
R T
S.I.Tech 2817-T/R
TTL Computer CPU Signal
Process Controller Instrument
R
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2016 S.I. Tech, Inc.
Model 2820
TRANSMISSION LINE INTERFACE Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application.
MODEL 2820
BIT-DRIVER TTL IN
Tx
PWR 5VDC
TTL IN
Tx
High Speed TTL to Fiber Optic Transmitters
S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-Drivers. Model 2820 consist of 2 850nm or 1310nm transmitters, or 850nm and 1310nm TR. Power Consumption: 150mA (50% Duty Cycle)
SYSTEM
Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable or 10 Km using single mode fiber Typical Bit Error Rate: Better than 10-9
ELECTRICAL SIGNAL INPUT FOR TRANSMITTER Format: TTL Connector: BNC Data Rate: DC - 50 Mbps Input Impedance: TTL levels 10 KΩ Input Power: 9-32VDC 1.5W Max. Optional 5VDC@250mA
OPTICAL TRANSMITTER LED Current: 30 microwatts (-15 dBm) into 62.5 micron fiber Wavelength: 820 nanometers (1300 nm option) Emitter Type: LED Optical Connector: ST Operating Temperature: 0 oC to 50 oC (optional extended temp for multimode) Size: 5.125" X 2.125" X 1.0" (13.00 X 5.40 X 2.54 cm) Weight: 6 oz (170 Grams)
Operating Distance for Fiber Optic Cable Fiber Size (Microns) 50 62.5 10 SM*
Attenuation Distance Distance (dB/Km) (Meters) (Feet) Wavelength (nm) Wavelength (nm) Wavelength (nm) 850 1300 1550 850 1300 1550 850 1300 1550 2000 6000 6600 20000 3.0 1.0 2000 6000 6600 20000 4.0 1.0 - 10000 12000 - 33000 40000 0.35 0.25
* Single mode (1300 and 1550 nm) option
ORDERING INFORMATION Model Numbers 2820 TTL to Fiber, 2 Transmitters, Multimode, ST Connector 2820-SM TTL to Fiber, 2 Transmitters, Single mode, ST Connector, 1300nm 2820-MM-SM TTL to Fiber, 2 Transmitters, 1 MM, 1 SM Notes: 1. Power Supply #2121 (110VAC to 9 VDC) is recommended for all models-USA 2. Optional Power Supply #2164 is for 230VAC applications 3. Optional Power Supply #2166 for 5VDC
TYPICAL APPLICATION Computer CPU Process Controller Instrument
TTL Signals
Computer TTL CPU Signals Process Controller Instrument
S.I.Tech 2820
T
FIBER CABLE
R
T
S.I.Tech 2820
T
R
1 FIBER
T WDM
WDM
S.I.Tech 2821
R R
S.I.Tech 2821
TTL Signals
TTL Signals
Computer CPU Process Controller Instrument
Computer CPU Process Controller Instrument
Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice. UL R
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2012 S.I. Tech, Inc.
Model 2821
TRANSMISSION LINE INTERFACE Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application.
MODEL 2821
TTL OUT
BIT-DRIVER
Rx
PWR 5VDC
TTL OUT
Rx
High Speed TTL to Fiber Optic Receivers
S.I.Tech offers complete links including fiber optic cable, connectors, cable assemblies, and Bit-Drivers. Model 2821 consist of 2 850nm or 1310nm Receivers or 850nm and 1310 receiver. Operating Distance for Fiber Optic Cable
SYSTEM
Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable or 10 Km using single mode fiber Typical Bit Error Rate: Better than 10 -9
Fiber Size (Microns) 50 62.5 10 SM*
Attenuation Distance Distance (dB/Km) (Meters) (Feet) Wavelength (nm) Wavelength (nm) Wavelength (nm) 850 1300 1550 850 1300 1550 850 1300 1550 2000 6000 6600 20000 3.0 1.0 2000 6000 6600 20000 4.0 1.0 - 10000 12000 - 33000 40000 0.35 0.25
* Single mode (1300 and 1550 nm) option
ELECTRICAL SIGNAL OUTPUT FOR RECEIVER Format: TTL Connector: BNC Data Rate: DC - 50 Mbps Output Impedance: TTL levels into 50Ω Input Power: 9-32VDC 1.5W Max. Optional 5VDC@250mA
OPTICAL RECEIVER Wavelength: 820 nm (1300 & 1550 nm option) Minimum Sensitivity: (BER ≤ 10-9) 3 microwatt (-25dBm) @820 nenometers Optical Connector: ST Operating Temperature: 0 oC to 50 oC (optional extended temp for multimode) Size: 5.125" X 2.125" X 1.0" (13.00 X 5.40 X 2.54 cm) Weight: 6 oz (170 Grams)
Power Consumption 50% Duty Cycle No TTL Load
ORDERING INFORMATION Model Numbers 2821 TTL to Fiber, 2 Receivers, Multimode, ST Connector 2821-SM TTL to Fiber, 2 Receivers, Single mode, ST Connector, 1300nm 2821-MM-SM TTL to Fiber, 2 Receivers, 1 MM, 1 SM Notes: 1. Power Supply #2121 (110VAC to 9 VDC) is recommended for all models-USA 2. Optional Power Supply #2164 is for 230VAC applications 3. Optional Power Supply #2166 for 5VDC
TYPICAL APPLICATION Computer CPU Process Controller Instrument
Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice.
220 mA
150 mA
2821
50Ω TTL Load
TTL Signals
Computer TTL CPU Signals Process Controller Instrument
S.I.Tech 2820
T
FIBER CABLE
R
T
S.I.Tech 2820
T
R
1 FIBER
T WDM
WDM
S.I.Tech 2821
R R
S.I.Tech 2821
TTL Signals
TTL Signals
Computer CPU Process Controller Instrument
Computer CPU Process Controller Instrument
UL R
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2012 S.I. Tech, Inc.
Model 2856 TTL to Fiber Optic Bit-Driver S.I. Tech Model 2856 is designed to convert TTL data to a light signal so that information can be transmitted over fiber optics. At the remote end, another 2856 will convert this data from light to TTL format.
S.I.Tech Bit-Driver
Asynchronous Optical
Model 2856 PWR
TD
RD
Operation Mode: Asynchronous, simplex or full duplex, 20 Mbps Input/Output Interface: TTL, 50 or 75 ohm coax. BNC bulkhead jack Transmission Line Interface: 2 ST fiber optic receptacles (SMA option) Transmission Distance: See distance chart Transmitter Output Power: 30 microwatts into 50 micron fiber Wavelength: 820 nanometers (1300 nm option) Receiver Wavelength: 820 nanometers (1300 nm option) Minimum Sensitivity: 3 microwatts @ 820 nanometers Bit Error Rate: 10 -9 Operating Temperature: 0 oC to 50 oC Input Power: 110 VAC 50/60 Hz Metal Enclosure: 7.5" x 7" x 3" (19 x 17.8 x 7.6 cm) Weight: 3 lbs. (1.36 kg) 230 Volt Version: 2856V Mini Version: 2817-T/R
Operating Distance for Fiber Optic Cable Fiber Size (Microns) 50 62.5 10 SM*
Distance Distance Attenuation (Meters) (Feet) (dB/Km) Wavelength (nm) Wavelength (nm) Wavelength (nm) 850 1300 1550 850 1300 1550 850 1300 1550 2000 6000 6600 20000 3.0 1.0 2000 6000 6600 20000 4.0 1.0 - 10000 12000 - 33000 40000 0.35 0.25
* Single mode (1300nm) option Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
Related Products Model Numbers 2856 2856-V 2856-SM 2856-2R 2856-4R 2856-4R-SM
Meets FCC Requirements of Class A, Part 15 Computing Device Standard. UL & CSA listed. Specifications subject to change without notice.
TTL to Fiber, Multimode, 110VAC, ST TTL to Fiber, Multimode, 230VAC, ST TTL to Fiber, Single Mode, 110VAC, ST TTL to Fiber, 2 Ch Rack Mounted, 110VAC, ST TTL to Fiber, 4 Ch Rack Mounted, 110VAC, ST TTL to Fiber, 4 Ch Rck Mnt, Single mode, 110VAC, ST
S.I.TECH BIT-DRIVER MODEL 2856-4R-SM
TD
RD
CHANNEL1
TD
RD
CHANNEL2
ON OFF
AC POWER
TD
RD
CHANNEL3
TD
RD
CHANNEL4
TYPICAL APPLICATION FIBER OPTIC CABLE
DTE CPU PROCESS CONTROLLER
R
COAX TTL
S.I.TECH 2856
T
R
T
S.I.TECH 2856
COAX TTL
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. ©2005 S.I. Tech, Inc.
Model 2860 RS-422 and TTL to Fiber Optic Bit-Driver The S.I.Tech Model 2860 is designed for high speed RS-422 and TTL data communication using fiber. This system uses TRIAX and BNC connectors for interfacing to high speed network. The model 2860 provides 4 independent channels for data, clock, etc.
S.I.TECH BIT-DRIVER MODEL 2860 TD
RD
TD
CHANNEL 1
CH 4 TX J1
TX
RX
J3
J4
CH 3 TX J1
TD
OFF
CHANNEL 2
RX J2
ON
RD
RX
J3
J4
CH 2
RX J2
RD
CHANNEL 3
POWER
TX
TX 85-260VAC 50/60 Hz 10W
J1
TX
RX
J3
J4
RX J2
TD
RD
CHANNEL 4
CH 1 TX J1
TX
RX
J3
J4
TRIAX CONNECTOR
RX J2
Ground BNC CONNECTOR Operation Mode: Asynchronous, simplex or full duplex, 20 Mbps Input/Output Interface: RS-422/TTL, 4 channel system, 4 Triax & 4 BNC connectors Transmission Line Interface: 8 ST connector fiber optic receptacles (SMA option) Transmission Distance: 2 Km - 6600 ft. (5 Km option) Transmitter Output Power: 30 microwatts into 50 micron fiber System Wavelength: 820 nanometers (1300 nm option) Minimum Sensitivity: 3 microwatts @ 820 nanometers at less than 10 -9 bit error rate Operating Temperature: 0 oC to 50 oC Input Power: 110 VAC 60 Hz Metal Enclosure: 1U 19" rack 17"W X 1.75"H X 7.5"D (43.2 X 4.3 X 19.0 CM) Weight: 5 lbs. (2.3 kg) 230 Volt Version: 2860V
Ground
Fiber Size (Microns) 62.5 50 10SM*
Attenuation dB/Km
Distance Meters
4.0 3.0 1.0
2000 2000 10000
Distance Feet 6600 6600 33000
* Single mode (1300nm) option (SC, ST, or FC) Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
Note: 2860-4R-SM: 4 CH, Single Mode J3: RS422 Input J4: TTL Output
Meets FCC Requirements of Class A, Part 15 Computing Device Standard. UL listed. Specifications subject to change without notice.
TYPICAL APPLICATION
RS-422 S.I.Tech 2857-4R
T
SM FIBER 1 2 3 4
R S.I.Tech 2860-4R
1 2 3 4
TTL TTL/RS422 EC
1 2 3 4
RS422
T S.I.Tech 2860-4R
SM FIBER 1 2 3 4
R S.I.Tech 2856-4R
TTL
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2009 S.I. Tech, Inc.
Model 2861 RS-422 and TTL to Fiber Optic Bit-Driver The S.I.Tech Model 2861 is designed for high speed RS-422 and TTL data communication using fiber. This system uses special 5 coax connectors for interfacing to high speed network. Model 2861 provides 5 independent channels for data, clock, etc. • Ruggedized for Field Application (Option) • Conformal Coated (Option) • Unit has Isolated Filtered Power Supply and Isolated Grounds
Coax Connectors
Operation Mode: Asynchronous, simplex or full duplex, 20 Mbps Input/Output Interface: RS-422/TTL, 5 channel system, 5 special coax connectors Transmission Line Interface: 10 ST connector fiber optic receptacles (SMA option) Transmission Distance: 2 Km - 6600 ft. (5 Km option) Transmitter Output Power: 30 microwatts into 50 micron fiber System Wavelength: 820 nanometers (1300 nm option) Minimum Sensitivity: 3 microwatts @ 820 nanometers at less than 10 -9 bit error rate Operating Temperature: 0 oC to 50 oC (-20 to +60oC for SM) Input Power: 110 VAC 60 Hz (18 to 36VDC Option) Metal Enclosure: 1U 19" rack 17"W X 1.75"H X 7.5"D (43.2 X 4.3 X 19.0 CM) Weight: 5 lbs. (2.3 kg) 230 Volt Version: 2861V
Fiber Size (Microns)
Attenuation dB/Km
62.5 50 10SM*
4.0 3.0 1.0
Distance Meters 2000 2000 10000
Distance Feet 6600 6600 33000
* Single mode (1300nm) option (SC, ST, or FC) Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
Note: 2861-5R-SM: 5 CH, Single Mode J3: RS422 Input J4: TTL Output
Meets FCC Requirements of Class A, Part 15 Computing Device Standard. UL listed. Specifications subject to change without notice.
TYPICAL APPLICATION
RS-422 S.I.Tech
SM T 1 FIBER 2 3 4 5
TTL
R S.I.Tech 2861-5R
1 2 3 4 5
TTL/RS422 EC
1 2 3 4 5
SM T 1 FIBER
RS422 S.I.Tech 2861-5R
2 3 4 5
R S.I.Tech
TTL
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2014 S.I. Tech, Inc.
Model 2865 TR/REC Fiber Optic Transmitter/Receiver Pair TRANSMISSION LINE INTERFACE Operating distance is dependent upon optical fiber core diameter and the cable's optical attenuation. The table below indicates three cables that may be used at any data rate. These cables are available in connectorized assemblies to meet the exact configuration of your application.
Pin 1
S.I.Tech offers complete links including fiber optic cable, connectors cable assemblies and Bit-Drivers.
Pin 8
SYSTEM
Transmission: Up to 6500 ft. (2 Km) with suitable graded index fiber optic cable Typical Bit Error Rate: Batter than 10 -9
ELECTRICAL SIGNAL INOUT/OUTOUT FOR TRANSMITTER AND RECEIVER Format: TTL Connector: Solder pads or DIP socket Duty Cycle: 0 to 100% Minimum Pulse Width: 50 nanoseconds Data Rate: DC to 20 Mbps NRZ Input impedance: TTL, optional 75 ohm TTL levels Output Impedance: Standard TTL logic output (sink 16 milliamps source 400 microamps) OPTICAL TRANSMITTER Output Power at 100 mA LED Current: 10 microwatts (-20 dBm) into 50 micron fiber Wavelength: 820 nanometers (1300 nm option) Emitter Type: LED Optical Connector: ST or SMA compatible metal receptacle OPTICAL RECEIVER Wavelength: 670 to 950 nanometers, 820 to 900 nanometers is optimum (1300 nm option) Minmum Sensitivity: (BER ≤ 10 -9 ) 1 microwatt (-30 dBm) @ 820 nanometers Maximum Sensitivity: 10 microwatts Minimum Optical Risetime required: 0.25 microseconds Optical Connector: ST or SMA compatible metal receptacle Operating Temperature: 0 oC to 50 oC Size: 2.70 X 2.85 in. (6.86 X 7.24 cm) Mini Version: 2817-T/R
OPERATING DISTANCE FOR FIBER OPTIC CABLE
Fiber Size (Microns)
Attenuation dB/km
100 62.5 50 10*
Distance Meters 2000 2000 2000 7000
5.0 4.0 3.0 1.0
Distance Feet 6600 6600 6600 23000
* Single mode, 1300 nm option Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
TYPICAL APPLICATION Computer CPU Process Controller (DTE)
TTL Signal
S.I.Tech 2865 (DCE)
FIBER T CABLE
T
S.I.Tech 2865 (DCE)
R R DTE: Data Terminal Equipment DCE: Data Communication Equipment
TTL Computer CPU Signal
Process Controller (DTE)
Pin Assighment - Transmitter/Receiver Board Pin No. (Dip Conn.) 1-8 9 10 11 12,13 14,15 16
Description Ground + 11 VDC to Receiver - 5 VDC to Receiver Receive Data from Receiver + 5 VDC to Receiver + 5 VDC to Transmitter Transmit Data to Transmitter
Meets FCC requirements of Class A, Part 15 Computing Devices Standard. Specifications subject to change without notice. For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. ©2005 S.I. Tech, Inc.
Model 2867 RS-422 and TTL to Fiber Optic Bit-Driver The S.I.Tech Model 2867 is designed for high speed RS-422 and TTL data communication using fiber. This system uses Terminal block and BNC connectors for interfacing to high speed network. The model 2867 provides 3 independent channels for data, clock, etc.
TERMINAL BLOCK Tx
Rx
IN
OUT
G
BNC CONNECTOR Operation Mode: Asynchronous, simplex or full duplex, 20 Mbps Input/Output Interface: RS-422/TTL, 3 channel system, 3 terminal blocks & 6 BNC connectors Transmission Line Interface: 6 ST connector fiber optic receptacles (FC Option-SM) Transmission Distance: See table Transmitter Output Power: 30 microwatts into 50 micron fiber System Wavelength: 820 nanometers (1300 nm option) Minimum Sensitivity: 3 microwatts @ 820 nanometers at less than 10 -9 bit error rate Operating Temperature: 0 oC to 50 oC Input Power: 85-260VAC, 50/60Hz, 10W Metal Enclosure: 1U 19" rack 17"W X 1.75"H X 7.5"D (43.2 X 4.3 X 19.0 CM) Weight: 5 lbs. (2.3 kg)
Fiber Size (Microns) 62.5 50 10SM*
Attenuation dB/Km (1300nm) 1.0 1.0 0.35
Distance Meters 5000 5000 20000
Distance Feet 16000 16000 65000
* Single mode (1300nm) Optical unit connection: Connect the optical transmission line to the T and R receptacles. Note which cable channel goes to T or R by noting cable imprint. On the other end, reverse the connection.
Note: 2867-3R-SM: 3 CH, Single Mode 2867 has built in switches for switching channel between TTL and RS-422 inputs.
Meets FCC Requirements of Class A, Part 15 Computing Device Standard. UL listed. RoHS compliance. Specifications subject to change without notice.
TYPICAL APPLICATION Tx1 Tx2 Tx3
RS-422
SMF
2867
2867
SMF
2867
RS-422
2867
TTL Rx1 Rx2 Rx3
RS-422
TELEMETRY
For application engineering assistance: 630-761-3640 FAX: 630-761-3644 S.I.Tech, P.O.Box 609, Geneva, Illinois 60134 U.S.A. Web site: http://www.sitech-bitdriver.com. C 2009 S.I. Tech, Inc.