2, 000 V AC breakdown voltage, 2 Form C and 2 A relays RoHS compliant TX RELAYS FEATURES TYPICAL APPLICATIONS 1. 2,000 V breakdown voltage between contact and coil 2. Outstanding surge resistance. 1,500 V 10×160μ sec. (FCC part 68) (open contacts) 2,500 V 2×10μ sec. (Telcordia) (contact and coil) 3. Nominal operating power: High sensitivity of 140mW 4. High contact capacity: 2 A 30 V DC 5. Compact size 15.0 (L) × 7.4 (W) × 8.2 (H) mm .591 (L) × .291 (W) × .323 (H) inch 6. High contact reliability High contact reliability is achieved by the use of gold-clad twin crossbar contacts, low-gas formation materials, mold sealing the coil section, and by controlling organic gas in the coil. *We also offer a range of products with AgPd contacts suitable for use in low level load analog circuits (Max. 10V DC 10 mA). 1. Communications (xDSL, Transmission) 2. Measurement 3. Security 4. Home appliances, and audio/visual equipment 5. Medical equipment ORDERING INFORMATION TX 2 Contact arrangement 2: 2 Form C Surface-mount availability Nil: Standard PC board terminal type SA: SA type Operating function Nil: Single side stable LT: 2 coil latching Terminal shape Nil: Standard PC board terminal or surface-mount terminal Nominal coil voltage (DC)* 3, 4.5, 5, 6, 9, 12, 24V Contact material Nil: Standard contact (Ag+Au clad) 1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable) Packing style Nil: Tube packing X: Tape and reel (picked from 1/3/4/5-pin side) Z: Tape and reel packing (picked from the 8/9/10/12-pin side) Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay. –1– ASCTB18E 201407-T TX TYPES 1. Standard PC board terminal Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC Single side stable Part No. TX2-3V TX2-4.5V TX2-5V TX2-6V TX2-9V TX2-12V TX2-24V 2 coil latching Part No. TX2-LT-3V TX2-LT-4.5V TX2-LT-5V TX2-LT-6V TX2-LT-9V TX2-LT-12V TX2-LT-24V Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load). 2. Surface-mount terminal 1) Tube packing Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC Single side stable Part No. TX2SA-3V TX2SA-4.5V TX2SA-5V TX2SA-6V TX2SA-9V TX2SA-12V TX2SA-24V 2 coil latching Part No. TX2SA-LT-3V TX2SA-LT-4.5V TX2SA-LT-5V TX2SA-LT-6V TX2SA-LT-9V TX2SA-LT-12V TX2SA-LT-24V Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load). 2) Tape and reel packing Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC Single side stable Part No. TX2SA-3V-Z TX2SA-4.5V-Z TX2SA-5V-Z TX2SA-6V-Z TX2SA-9V-Z TX2SA-12V-Z TX2SA-24V-Z 2 coil latching Part No. TX2SA-LT-3V-Z TX2SA-LT-4.5V-Z TX2SA-LT-5V-Z TX2SA-LT-6V-Z TX2SA-LT-9V-Z TX2SA-LT-12V-Z TX2SA-LT-24V-Z Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. 2. Please add “-1” to the end of the part number for AgPd contacts (low level load). RATING 1. Coil data 1) Single side stable Nominal coil voltage 3 Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 75%V or less of nominal voltage* (Initial) 10%V or more of nominal voltage* (Initial) Nominal operating current [±10%] (at 20°C 68°F) 46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 5.8 mA Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 140 mW 150%V of nominal voltage 64.3 Ω 145 178 257 579 1,028 4,114 Ω Ω Ω Ω Ω Ω 2) 2 coil latching Nominal coil voltage 3 Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 75%V or less of nominal voltage* (Initial) 75%V or less of nominal voltage* (Initial) Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil 66.7 mA 66.7 mA 44.5 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA 44.5 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA Coil resistance [±10%] (at 20°C 68°F) Set coil 45 Ω Reset coil 45 Ω 101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω 101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω Nominal operating power Set coil Reset coil 200 mW 200 mW Max. applied voltage (at 20°C 68°F 150%V of nominal voltage *Pulse drive (JIS C 5442-1986) –2– ASCTB18E 201407-T TX 2. Specifications Characteristics Contact Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Single side stable Nominal operating power 2 coil latching Insulation resistance (Initial) Between open contacts Breakdown voltage Between contact and coil (Initial) Between contact sets Between open contacts Surge breakdown voltage (Initial) Between contacts and coil Rating Electrical characteristics Temperature rise (at 20°C 68°F) Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical (Standard contact) Shock resistance Mechanical characteristics Expected life Conditions for operation, transport and storage*2 Conditions Max. operating speed (at rated load) Unit weight Specifications 2 Form C Max. 100 mΩ (By voltage drop 6 V DC 1A) Standard contact: Ag+Au clad, AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable) Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load) Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load) 220V DC Standard contact: 2 A, AgPd contact: 1 A 10μA 10mV DC 140 mW (3 to 24 V DC) 200 mW (3 to 24 V DC) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. 1,000 Vrms for 1min. (Detection current: 10mA) 2,000 Vrms for 1min. (Detection current: 10mA) 1,000 Vrms for 1min. (Detection current: 10mA) 1,500 V (10×160μs) (FCC Part 68) 2,500 V (2×10μs) (Telcordia) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5 mm Min. 108 (at 180 cpm) Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive) (at 20 cpm) Ambient temperature: –40°C to +85°C (up to 24 V coil) –40°F to +185°F (up to 24 V coil) [–40°C to +70°C (48 V coil) –40°F to +158°F (48 V coil)]; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 2 g .071 oz Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level]) *2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES. REFERENCE DATA 1. Maximum switching capacity 2. Life curve 3. Mechanical life Ratio against the rated voltage, %V Tested sample: TX2-5V, 10 pcs. Operating speed: 180 cpm 2.0 100 No. of operations ×104 Switching current, A 3.0 DC resistive load 1.0 0.5 0.4 0.3 50 30V DC resistive load 30 20 10 0.2 100 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 30 Drop-out voltage 20 Max. Min. 10 0 20 30 0 50 100 200 300 Contact voltage, V 0 1.0 2.0 Switching current, A 10 100 1,000 No. of operations, ×104 10,000 4. Electrical life (2A 30V DC resistive load) 5. Coil temperature rise Tested sample: TX2-5V, 6 pcs. Operating speed: 20 cpm Tested sample: TX2-5V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F, 85°C 185°F Change of contact resistance 100 90 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. 20 80 70 60 50 40 Max. 30 Min. +25°C +77°F +85°C +185°F 60 50 40 30 2A 2A 20 0A 0A 20 Min. 10 0 70 Temperature rise, °C 100 Contact resistance, mΩ Ratio against the rated voltage, %V Change of pick-up and drop-out voltage 1 2 3 4 5 6 7 8 9 No. of operations, ×104 10 10 10 0 1 2 3 4 5 6 7 8 9 No. of operations, ×104 –3– 10 0 100 110 120 130 140 150 Coil applied voltage, % ASCTB18E 201407-T TX 6-(2). Operate and release time (without diode) 7. Ambient temperature characteristics Tested sample: TX2-5V, 10 pcs. Tested sample: TX2-5V, 10 pcs. Tested sample: TX2-5V, 5 pcs. 5 Operate and release time, ms 4 Max. Min. 3 Max. Min. 2 Operate and release time, ms 5 Operate time Release time Rate of change, % 6-(1). Operate and release time (with diode) Operate time Release time 4 Max. Min. 3 –40 –20 2 1 0 0 20 Drop-out voltage x x Pick-up voltage 20 40 60 80 Ambient temperature, °C –20 Max. Min. 1 0 40 –40 70 80 90 100 110 120 Coil applied voltage, %V 70 80 90 100 110 120 Coil applied voltage, %V Tested sample: TX2-12V, 2 pcs. Tested sample: TX2-12V, 2 pcs. Insertion loss, dB 8-(2). High frequency characteristics (Insertion loss) Isolation, dB 8-(1). High frequency characteristics (Isolation) 100 50 9. Malfunctional shock (single side stable) Tested sample: TX2-5V, 6 pcs. Z' Y Y' Z XX' Deenergized condition Energized condition Y 1000m/s 2 X 1000m/s2 Z 1000m/s2 1000m/s 2 Z' 1000m/s2 X' 1.0 0.8 0.6 0.4 1000m/s 2 Y' 0.2 10 100 Frequency, MHz 1,000 10 100 Frequency, MHz 1,000 Tested sample: TX2-12V, 6 pcs. ON ON Pick-up voltage 0 –5 ON Rate of change, % Rate of change, % 5 Rate of change, % 10-(2). Influence of adjacent mounting Tested sample: TX2-12V, 6 pcs. Rate of change, % 10-(1). Influence of adjacent mounting OFF OFF 5 Drop-out voltage 0 –5 OFF 0 2 4 6 8 10 .079 .157 .236 .315 .394 Inter-relay distance ON 5 Pick-up voltage 0 ON –5 ON OFF 5 Drop-out voltage 0 OFF –5 OFF 0 , mm inch 2 4 6 8 10 .079 .157 .236 .315 .394 Inter-relay distance , mm inch 11. Pulse dialing test Circuit + 458 Ω 0.08 μF 48V DC – 0.08 μF 458 Ω Wire spring relay 4 TX 3 Ratio against the rated voltage, %V Change of pick-up and drop-out voltage Change of contact resistance 100 100 90 90 80 Pick-up voltage 70 Max. Min. 60 50 40 Drop-out voltage 30 20 Max. Min. 80 70 60 50 Max. 40 Min. 30 20 10 10 0 Contact resistance, mΩ Tested sample: TX2-5V, 6 pcs. (35 mA 48 V DC wire spring relay load) 10 20 30 40 No. of operation, ×104 50 0 10 20 30 40 No. of operations, ×104 50 Note: Data of surface-mount type are the same as those of PC board terminal type. –4– ASCTB18E 201407-T TX DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1. Standard PC board terminal and Self clinching terminal Single side stable type CAD Data External dimensions 2 coil latching type External dimensions Standard PC board terminal 15.00 .591 Standard PC board terminal 7.40 .291 0.50 .020 1.15 .045 5.08 .200 3.50 .138 2.54 .100 0.65 .026 0.50 .020 1.15 .045 0.25 5.08 .010 .200 5.08 .200 2.54 .100 General tolerance: ±0.3 ±.012 PC board pattern (Bottom view) Schematic (Bottom view) Single side stable 10.16 .400 2.54 .100 + 5.08 .200 – 8-1.0 dia. 8-.039 dia. 1 PC board pattern (Bottom view) 12.7 .500 3 4 5 2.54 .100 10 9 8 10-1.0 dia. 10-.039 dia. (Deenergized condition) 0.25 5.08 .010 .200 3.50 .138 Schematic (Bottom view) 2 coil latching + 5.08 .200 12 8.20 .323 General tolerance: ±0.3 ±.012 Direction indication Tolerance: ±0.1 ±.004 7.40 .291 15.00 .591 0.65 .026 8.20 .323 1 – 12 3 4 5 6 10 9 8 7 + – Direction indication Tolerance: ±0.1 ±.004 (Reset condition) 2. Surface-mount terminal CAD Data External dimensions (General tolerance: ±0.3 ±.012) Single side stable type 2 coil latching type Type 15 .591 8.2 8.4 .323 .331 SA type 0.5 .020 0.65 .026 5.08 .200 15 .591 7.4 .291 5.08 .200 9.4±0.5 .370±.020 2.54 .100 Suggested mounting pad (Top view) (Tolerance: ±0.1 ±.004) Single side stable type 2 coil latching type 7.4 .291 8.2 8.4 .323 .331 0.25 .010 0.5 .020 0.65 .026 5.08 .200 2.54 .100 5.08 .200 9.4±0.5 .370±.020 1 3.16 .039 .124 0.25 .010 5.08 .200 2.54 .100 5.08 1 .200 3.16 .039 .124 7.24 .285 2.54 .100 7.24 .285 Schematic (Top view) Single side stable – + 12 10 9 8 1 3 4 5 Direction indication (Deenergized condition) 2 coil latching – + 12 10 9 8 7 1 3 4 5 6 – + Direction indication (Reset condition) –5– ASCTB18E 201407-T TX NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1) stripe Stopper (gray) Stopper (green) 2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions 2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500gf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less A C B mm inch 1.5 Relay polarity bar .059 (Z type) +0.1 0 +.004 0 dia. dia. 2.0 .079 1.75 .069 4.0 .157 0.4 .016 C A Relays B 11.5 .453 D 16.0 10.0 .394 .630 15.5 .610 24.0 ±0.3 ±0.2 .945 ±.012 9.2±.008 .362 Tape coming out direction Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. (2) Dimensions of plastic reel mm inch 2.0 .079 13 dia. .512 dia. 21 dia. .827 dia. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”. 380 dia. 14.961 dia. 80 dia. 3.150 dia. –6– ASCTB18E 201407-T Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: TX2-4.5V TX2-L2-5V TX2-5V TX2SA-5V TX2SA-5V-Z TX2-12V TX2SA-12V TX2-24V TX2SA-24V TX2SA-24VZ TX2SA-12V-1 TXS2SL-9V-1 TX2SL-3V TX2-L-3V TX2-3V TX2SA-L2-3V TX2SA-3V TX2SA-L2-4.5V TX2SA4.5V TX2SS-4.5V TX2-L-5V TX2-9V TX2SA-L2-5V TX2SL-5V TX2SA-L2-12V TX2SA-12V-Z TX2SL-24V TX2SS24V TX2-48V TX2SS-48V TX2-L2-4.5V TX2-L2-9V TX2-L-4.5V TX2SL-4.5V TX2SA-9V TX2-L2-24V TX2-L2-12V TX2SS-5V TX2SL-12V TX2-LT-12V TX2-LT-24V TX2-LT-4.5V TX2SA-LT-12V TX2SA-LT-3V TX2SA-LT-4.5V TX2SA-LT-4.5V-Z TX2SA-LT-5V TX2SA-LT-5V-Z TX2SL-LT-3V TX2SL-LT-3V-X TX2SL-LT-3V-Z TX2SL-LT-4.5V TX2SA-3V-1 TX2SA-LT-24V-Z TX2SS-LT-5V-Z TX2SA-LT-12V-X TX2-L-12V-1 TX2SS-LT-12V-X TX2SS-LT-5V-X TX2SA-12V-1-X TX2SA-12V-1-Z TX2-L-9V-1 TX2SA-3V-1-Z TX2SS-LT-12V-Z TX2SS-LT-3V TX2SA-3V-1-X