Transcript
2, 000 V AC breakdown voltage, 2 Form C and 2 A relays
RoHS compliant
TX RELAYS
FEATURES
TYPICAL APPLICATIONS
1. 2,000 V breakdown voltage between contact and coil 2. Outstanding surge resistance. 1,500 V 10×160μ sec. (FCC part 68) (open contacts) 2,500 V 2×10μ sec. (Telcordia) (contact and coil) 3. Nominal operating power: High sensitivity of 140mW 4. High contact capacity: 2 A 30 V DC 5. Compact size 15.0 (L) × 7.4 (W) × 8.2 (H) mm .591 (L) × .291 (W) × .323 (H) inch 6. High contact reliability High contact reliability is achieved by the use of gold-clad twin crossbar contacts, low-gas formation materials, mold sealing the coil section, and by controlling organic gas in the coil. *We also offer a range of products with AgPd contacts suitable for use in low level load analog circuits (Max. 10V DC 10 mA).
1. Communications (xDSL, Transmission) 2. Measurement 3. Security 4. Home appliances, and audio/visual equipment 5. Medical equipment
ORDERING INFORMATION TX 2 Contact arrangement 2: 2 Form C Surface-mount availability Nil: Standard PC board terminal type SA: SA type Operating function Nil: Single side stable LT: 2 coil latching Terminal shape Nil: Standard PC board terminal or surface-mount terminal Nominal coil voltage (DC)* 3, 4.5, 5, 6, 9, 12, 24V Contact material Nil: Standard contact (Ag+Au clad) 1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable) Packing style Nil: Tube packing X: Tape and reel (picked from 1/3/4/5-pin side) Z: Tape and reel packing (picked from the 8/9/10/12-pin side) Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
–1–
ASCTB18E 201407-T
TX TYPES 1. Standard PC board terminal Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
Single side stable Part No. TX2-3V TX2-4.5V TX2-5V TX2-6V TX2-9V TX2-12V TX2-24V
2 coil latching Part No. TX2-LT-3V TX2-LT-4.5V TX2-LT-5V TX2-LT-6V TX2-LT-9V TX2-LT-12V TX2-LT-24V
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2. Surface-mount terminal 1) Tube packing Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
Single side stable Part No. TX2SA-3V TX2SA-4.5V TX2SA-5V TX2SA-6V TX2SA-9V TX2SA-12V TX2SA-24V
2 coil latching Part No. TX2SA-LT-3V TX2SA-LT-4.5V TX2SA-LT-5V TX2SA-LT-6V TX2SA-LT-9V TX2SA-LT-12V TX2SA-LT-24V
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Tape and reel packing Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
Single side stable Part No. TX2SA-3V-Z TX2SA-4.5V-Z TX2SA-5V-Z TX2SA-6V-Z TX2SA-9V-Z TX2SA-12V-Z TX2SA-24V-Z
2 coil latching Part No. TX2SA-LT-3V-Z TX2SA-LT-4.5V-Z TX2SA-LT-5V-Z TX2SA-LT-6V-Z TX2SA-LT-9V-Z TX2SA-LT-12V-Z TX2SA-LT-24V-Z
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. 2. Please add “-1” to the end of the part number for AgPd contacts (low level load).
RATING 1. Coil data 1) Single side stable Nominal coil voltage 3
Pick-up voltage (at 20°C 68°F)
Drop-out voltage (at 20°C 68°F)
V DC
4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
75%V or less of nominal voltage* (Initial)
10%V or more of nominal voltage* (Initial)
Nominal operating current [±10%] (at 20°C 68°F) 46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 5.8 mA
Coil resistance [±10%] (at 20°C 68°F)
Nominal operating power
Max. applied voltage (at 20°C 68°F)
140 mW
150%V of nominal voltage
64.3 Ω 145 178 257 579 1,028 4,114
Ω Ω Ω Ω Ω Ω
2) 2 coil latching Nominal coil voltage 3
Set voltage (at 20°C 68°F)
Reset voltage (at 20°C 68°F)
V DC
4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
75%V or less of nominal voltage* (Initial)
75%V or less of nominal voltage* (Initial)
Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil 66.7 mA 66.7 mA 44.5 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
44.5 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance [±10%] (at 20°C 68°F) Set coil 45 Ω
Reset coil 45 Ω
101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω
101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω
Nominal operating power Set coil
Reset coil
200 mW
200 mW
Max. applied voltage (at 20°C 68°F
150%V of nominal voltage
*Pulse drive (JIS C 5442-1986)
–2–
ASCTB18E 201407-T
TX 2. Specifications Characteristics
Contact
Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Single side stable Nominal operating power 2 coil latching Insulation resistance (Initial) Between open contacts Breakdown voltage Between contact and coil (Initial) Between contact sets Between open contacts Surge breakdown voltage (Initial) Between contacts and coil
Rating
Electrical characteristics
Temperature rise (at 20°C 68°F) Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical (Standard contact) Shock resistance
Mechanical characteristics
Expected life
Conditions for operation, transport and storage*2
Conditions
Max. operating speed (at rated load) Unit weight
Specifications 2 Form C Max. 100 mΩ (By voltage drop 6 V DC 1A) Standard contact: Ag+Au clad, AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable) Standard contact: 2 A 30 V DC, AgPd contact: 1 A 30 V DC (resistive load) Standard contact: 60 W (DC), AgPd contact: 30 W (DC) (resistive load) 220V DC Standard contact: 2 A, AgPd contact: 1 A 10μA 10mV DC 140 mW (3 to 24 V DC) 200 mW (3 to 24 V DC) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. 1,000 Vrms for 1min. (Detection current: 10mA) 2,000 Vrms for 1min. (Detection current: 10mA) 1,000 Vrms for 1min. (Detection current: 10mA) 1,500 V (10×160μs) (FCC Part 68) 2,500 V (2×10μs) (Telcordia) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5 mm Min. 108 (at 180 cpm) Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive) (at 20 cpm) Ambient temperature: –40°C to +85°C (up to 24 V coil) –40°F to +185°F (up to 24 V coil) [–40°C to +70°C (48 V coil) –40°F to +158°F (48 V coil)]; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 2 g .071 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level]) *2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA 1. Maximum switching capacity
2. Life curve
3. Mechanical life
Ratio against the rated voltage, %V
Tested sample: TX2-5V, 10 pcs. Operating speed: 180 cpm
2.0
100 No. of operations ×104
Switching current, A
3.0
DC resistive load
1.0
0.5 0.4 0.3
50 30V DC resistive load
30 20 10
0.2
100 90 80
Pick-up voltage
70
Max.
60
Min.
50 40 30
Drop-out voltage
20
Max. Min.
10 0
20 30
0
50 100 200 300 Contact voltage, V
0
1.0 2.0 Switching current, A
10
100 1,000 No. of operations, ×104
10,000
4. Electrical life (2A 30V DC resistive load)
5. Coil temperature rise
Tested sample: TX2-5V, 6 pcs. Operating speed: 20 cpm
Tested sample: TX2-5V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F, 85°C 185°F
Change of contact resistance 100
90
90
80
Pick-up voltage
70
Max.
60
Min.
50 40
Drop-out voltage
30
Max.
20
80 70 60 50 40
Max.
30
Min.
+25°C +77°F +85°C +185°F
60 50 40 30
2A 2A
20
0A 0A
20 Min.
10 0
70 Temperature rise, °C
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
1
2
3
4 5 6 7 8 9 No. of operations, ×104
10
10
10 0
1
2
3
4 5 6 7 8 9 No. of operations, ×104
–3–
10
0
100 110
120 130 140 150 Coil applied voltage, %
ASCTB18E 201407-T
TX 6-(2). Operate and release time (without diode)
7. Ambient temperature characteristics
Tested sample: TX2-5V, 10 pcs.
Tested sample: TX2-5V, 10 pcs.
Tested sample: TX2-5V, 5 pcs.
5 Operate and release time, ms
4
Max. Min.
3
Max. Min.
2
Operate and release time, ms
5 Operate time Release time
Rate of change, %
6-(1). Operate and release time (with diode)
Operate time Release time
4
Max. Min.
3
–40 –20 2
1
0
0
20
Drop-out voltage x x Pick-up voltage
20 40 60 80 Ambient temperature, °C –20
Max. Min.
1
0
40
–40 70
80
90 100 110 120 Coil applied voltage, %V
70
80
90 100 110 120 Coil applied voltage, %V
Tested sample: TX2-12V, 2 pcs.
Tested sample: TX2-12V, 2 pcs.
Insertion loss, dB
8-(2). High frequency characteristics (Insertion loss)
Isolation, dB
8-(1). High frequency characteristics (Isolation)
100
50
9. Malfunctional shock (single side stable) Tested sample: TX2-5V, 6 pcs.
Z' Y Y'
Z XX'
Deenergized condition Energized condition
Y 1000m/s 2
X 1000m/s2
Z 1000m/s2
1000m/s 2 Z'
1000m/s2 X'
1.0 0.8 0.6 0.4 1000m/s 2 Y'
0.2 10
100 Frequency, MHz
1,000
10
100 Frequency, MHz
1,000
Tested sample: TX2-12V, 6 pcs. ON
ON
Pick-up voltage 0 –5
ON
Rate of change, %
Rate of change, %
5
Rate of change, %
10-(2). Influence of adjacent mounting
Tested sample: TX2-12V, 6 pcs. Rate of change, %
10-(1). Influence of adjacent mounting
OFF OFF
5 Drop-out voltage
0 –5
OFF 0
2 4 6 8 10 .079 .157 .236 .315 .394 Inter-relay distance
ON
5 Pick-up voltage 0
ON
–5
ON OFF
5 Drop-out voltage 0
OFF –5 OFF 0
, mm inch
2 4 6 8 10 .079 .157 .236 .315 .394 Inter-relay distance
, mm inch
11. Pulse dialing test
Circuit
+
458 Ω
0.08 μF 48V DC
–
0.08 μF
458 Ω Wire spring relay
4 TX 3
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
Change of contact resistance
100
100
90
90
80
Pick-up voltage
70
Max. Min.
60 50 40 Drop-out voltage
30 20
Max. Min.
80 70 60 50
Max.
40 Min.
30 20 10
10 0
Contact resistance, mΩ
Tested sample: TX2-5V, 6 pcs. (35 mA 48 V DC wire spring relay load)
10
20 30 40 No. of operation, ×104
50
0
10
20 30 40 No. of operations, ×104
50
Note: Data of surface-mount type are the same as those of PC board terminal type.
–4–
ASCTB18E 201407-T
TX DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. Standard PC board terminal and Self clinching terminal Single side stable type CAD Data External dimensions
2 coil latching type External dimensions
Standard PC board terminal 15.00 .591
Standard PC board terminal
7.40 .291
0.50 .020 1.15 .045
5.08 .200
3.50 .138
2.54 .100
0.65 .026
0.50 .020 1.15 .045
0.25 5.08 .010 .200
5.08 .200
2.54 .100
General tolerance: ±0.3 ±.012
PC board pattern (Bottom view)
Schematic (Bottom view) Single side stable
10.16 .400
2.54 .100
+ 5.08 .200
–
8-1.0 dia. 8-.039 dia.
1
PC board pattern (Bottom view) 12.7 .500
3 4 5 2.54 .100
10 9 8 10-1.0 dia. 10-.039 dia.
(Deenergized condition)
0.25 5.08 .010 .200
3.50 .138
Schematic (Bottom view) 2 coil latching +
5.08 .200 12
8.20 .323
General tolerance: ±0.3 ±.012
Direction indication
Tolerance: ±0.1 ±.004
7.40 .291
15.00 .591
0.65 .026 8.20 .323
1
– 12
3 4 5 6
10 9 8 7
+ –
Direction indication
Tolerance: ±0.1 ±.004
(Reset condition)
2. Surface-mount terminal CAD Data
External dimensions (General tolerance: ±0.3 ±.012) Single side stable type 2 coil latching type
Type
15 .591 8.2 8.4 .323 .331
SA type 0.5 .020
0.65 .026 5.08 .200
15 .591
7.4 .291
5.08 .200 9.4±0.5 .370±.020
2.54 .100
Suggested mounting pad (Top view) (Tolerance: ±0.1 ±.004) Single side stable type 2 coil latching type 7.4 .291
8.2 8.4 .323 .331
0.25 .010 0.5 .020
0.65 .026 5.08 .200
2.54 .100
5.08 .200 9.4±0.5 .370±.020
1 3.16 .039 .124 0.25 .010
5.08 .200
2.54 .100
5.08 1 .200 3.16 .039 .124 7.24 .285
2.54 .100
7.24 .285
Schematic (Top view) Single side stable
– +
12
10 9 8
1
3
4 5
Direction indication
(Deenergized condition)
2 coil latching – +
12
10 9 8 7
1
3
4 5 6
– +
Direction indication
(Reset condition)
–5–
ASCTB18E 201407-T
TX NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1) stripe
Stopper (gray)
Stopper (green)
2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions
2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500gf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less A
C
B
mm inch 1.5 Relay polarity bar .059 (Z type)
+0.1 0 +.004 0
dia. dia. 2.0 .079
1.75 .069
4.0 .157
0.4 .016
C A
Relays
B
11.5 .453
D 16.0 10.0 .394 .630
15.5 .610
24.0 ±0.3 ±0.2 .945 ±.012 9.2±.008 .362
Tape coming out direction
Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided.
(2) Dimensions of plastic reel mm inch
2.0 .079 13 dia. .512 dia.
21 dia. .827 dia.
For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”.
380 dia. 14.961 dia. 80 dia. 3.150 dia.
–6–
ASCTB18E 201407-T
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic: TX2-4.5V TX2-L2-5V TX2-5V TX2SA-5V TX2SA-5V-Z TX2-12V TX2SA-12V TX2-24V TX2SA-24V TX2SA-24VZ TX2SA-12V-1 TXS2SL-9V-1 TX2SL-3V TX2-L-3V TX2-3V TX2SA-L2-3V TX2SA-3V TX2SA-L2-4.5V TX2SA4.5V TX2SS-4.5V TX2-L-5V TX2-9V TX2SA-L2-5V TX2SL-5V TX2SA-L2-12V TX2SA-12V-Z TX2SL-24V TX2SS24V TX2-48V TX2SS-48V TX2-L2-4.5V TX2-L2-9V TX2-L-4.5V TX2SL-4.5V TX2SA-9V TX2-L2-24V TX2-L2-12V TX2SS-5V TX2SL-12V TX2-LT-12V TX2-LT-24V TX2-LT-4.5V TX2SA-LT-12V TX2SA-LT-3V TX2SA-LT-4.5V TX2SA-LT-4.5V-Z TX2SA-LT-5V TX2SA-LT-5V-Z TX2SL-LT-3V TX2SL-LT-3V-X TX2SL-LT-3V-Z TX2SL-LT-4.5V TX2SA-3V-1 TX2SA-LT-24V-Z TX2SS-LT-5V-Z TX2SA-LT-12V-X TX2-L-12V-1 TX2SS-LT-12V-X TX2SS-LT-5V-X TX2SA-12V-1-X TX2SA-12V-1-Z TX2-L-9V-1 TX2SA-3V-1-Z TX2SS-LT-12V-Z TX2SS-LT-3V TX2SA-3V-1-X