Preview only show first 10 pages with watermark. For full document please download

Tx-s Agpd Contact Type

   EMBED


Share

Transcript

TX-S Very High Sensitivity, 50 mW (nominal operating) Relay with LT style pin layout FEATURES 1. Nominal operating power: High sensitivity of 50 mW By using the highly efficient polar magnetic circuit “seesaw balance mechanism”, a nominal operating power of 50 mW (minimum operating power of 32 mW) has been achieved. 2. Compact size 15.0(L)  7.4(W)  8.2(H) .591(L)  .291(W)  .323(H) 3. High contact reliability High contact reliability is achieved by the use of gold-clad twin crossbar contacts, low-gas formation materials, mold sealing the coil section, and by controlling organic gas in the coil. *We also offer a range of products with AgPd contacts suitable for use in low level load analog circuits (max. 10V DC 10 mA). 4. Outstanding surge resistance Surge breakdown voltage between open contacts: 1,500 V 10160 sec. (FCC part 68) Surge breakdown voltage between contact and coil: 2,500 V 210 sec. (Telcordia) 5. Low thermal electromotive force (approx. 0.3 V) The structure of the mold-sealed body block of the coil section achieves nominal operating power of 50 mW and high sensitivity, along with low thermal electromotive force, reduced to approximately 0.3 V. TX-S RELAYS 6. A range of surface-mount types is also available. SA: Low-profile surface-mount terminal type SS: Space saving surface-mount terminal type 7. Sealed construction allows automatic washing. 8. Sealed according to RTIII (IP67 TYPICAL APPLICATIONS 1. Communications (XDSL, Transmission) 2. Measurement 3. Security 4. Home appliances, and audio/visual equipment 5. Automotive equipment 6. Medical equipment ORDERING INFORMATION TXS 2 Contact arrangement 2: 2 Form C Surface-mount availability Nil: Standard PC board terminal type SA: SA type SS: SS type Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching LT: 2 coil latching Terminal shape Nil: Standard PC board terminal or surface-mount terminal Nominal coil voltage (DC) 1.5, 3, 4.5, 6, 9, 12, 24V Contact material Nil: Standard contact (Ag+Au clad) 1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable) Packing style Nil: Tube packing X: Tape and reel (picked from 1/3/4/5-pin side) Z: Tape and reel packing (picked from the 8/9/10/12-pin side) ds_61022_en_txs: 280114D 1 TX-S TYPES 1. Standard PC board terminal Contact arrangement Nominal coil voltage 2 Form C 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. TXS2-1.5V TXS2-3V TXS2-4.5V TXS2-6V TXS2-9V TXS2-12V TXS2-24V 1 coil latching Part No. TXS2-L-1.5V TXS2-L-3V TXS2-L-4.5V TXS2-L-6V TXS2-L-9V TXS2-L-12V TXS2-L-24V 2 coil latching (L2) Part No. TXS2-L2-1.5V TXS2-L2-3V TXS2-L2-4.5V TXS2-L2-6V TXS2-L2-9V TXS2-L2-12V TXS2-L2-24V 2 coil latching (LT) Part No. TXS2-LT-1.5V TXS2-LT-3V TXS2-LT-4.5V TXS2-LT-6V TXS2-LT-9V TXS2-LT-12V TXS2-LT-24V 2 coil latching (L2) Part No. TXS2S-L2-1.5V TXS2S-L2-3V TXS2S-L2-4.5V TXS2S-L2-6V TXS2S-L2-9V TXS2S-L2-12V TXS2S-L2-24V 2 coil latching (LT) Part No. TXS2S-LT-1.5V TXS2S-LT-3V TXS2S-LT-4.5V TXS2S-LT-6V TXS2S-LT-9V TXS2S-LT-12V TXS2S-LT-24V 2 coil latching (L2) Part No. TXS2S-L2-1.5V-Z TXS2S-L2-3V-Z TXS2S-L2-4.5V-Z TXS2S-L2-6V-Z TXS2S-L2-9V-Z TXS2S-L2-12V-Z TXS2S-L2-24V-Z 2 coil latching (LT) Part No. TXS2S-LT-1.5V-Z TXS2S-LT-3V-Z TXS2S-LT-4.5V-Z TXS2S-LT-6V-Z TXS2S-LT-9V-Z TXS2S-LT-12V-Z TXS2S-LT-24V-Z Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load). 2. Surface-mount terminal 1) Tube packing Contact arrangement Nominal coil voltage 2 Form C 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. TXS2S-1.5V TXS2S-3V TXS2S-4.5V TXS2S-6V TXS2S-9V TXS2S-12V TXS2S-24V 1 coil latching Part No. TXS2S-L-1.5V TXS2S-L-3V TXS2S-L-4.5V TXS2S-L-6V TXS2S-L-9V TXS2S-L-12V TXS2S-L-24V : For each surface-mounted terminal identification, input the following letter. SA type: A, SS type: S Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load). 2) Tape and reel packing Contact arrangement Nominal coil voltage 2 Form C 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. TXS2S-1.5V-Z TXS2S-3V-Z TXS2S-4.5V-Z TXS2S-6V-Z TXS2S-9V-Z TXS2S-12V-Z TXS2S-24V-Z 1 coil latching Part No. TXS2S-L-1.5V-Z TXS2S-L-3V-Z TXS2S-L-4.5V-Z TXS2S-L-6V-Z TXS2S-L-9V-Z TXS2S-L-12V-Z TXS2S-L-24V-Z : For each surface-mounted terminal identification, input the following letter. SA type: A, SS type: S Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. 2. Please add “-1” to the end of the part number for AgPd contacts (low level load). (Ex. TXS2SA-1.5V-1-Z) RATING 1. Coil data 1) Single side stable Nominal coil voltage Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) Nominal operating power Max. applied voltage (at 20C 68F) 50mW 150%V of nominal voltage 1.5V DC 33.3mA 45 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC 16.7mA 11.1mA 8.3mA 5.6mA 4.2mA 2.9mA 180 405 720 1,620 2,880 8,229 70mW Coil resistance [10%] (at 20C 68F) Nominal operating power Max. applied voltage (at 20C 68F) 35mW 150%V of nominal voltage 80%V or less of nominal voltage* (Initial) 10%V or more of nominal voltage* (Initial) 2) 1 coil latching 1.5V DC Nominal operating current [10%] (at 20C 68F) 23.3mA 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC 11.7mA 7.8mA 5.8mA 3.9mA 2.9mA 2.1mA Nominal coil voltage 2 Set voltage (at 20C 68F) 80%V or less of nominal voltage* (Initial) Reset voltage (at 20C 68F) 80%V or less of nominal voltage* (Initial) 64.3 257 579 1,029 2,314 4,114 11,520 50mW ds_61022_en_txs: 280114D TX-S 3) 2 coil latching (L2, LT) Nominal coil voltage Set voltage (at 20C 68F) Reset voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) Set coil Reset coil 1.5V DC 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC 80%V or less of nominal voltage* (Initial) 80%V or less of nominal voltage* (Initial) 46.7mA 23.3mA 15.6mA 11.7mA 7.8mA 5.8mA 6.3mA 46.7mA 23.3mA 15.6mA 11.7mA 7.8mA 5.8mA 6.3mA Coil resistance [10%] (at 20C 68F) Set coil Reset coil 32.1 129 289 514 1,157 2,057 3,840 32.1 129 289 514 1,157 2,057 3,840 Nominal operating power Set coil Reset coil 70mW 70mW 150mW 150mW Max. applied voltage (at 20C 68F) 150%V of nominal voltage *Pulse drive (JIS C 5442-1986) 2. Specifications Characteristics Contact Item Arrangement Initial contact resistance, max. Contact material Rating Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Nominal operating power Single side stable 1 coil latching 2 coil latching Insulation resistance (Initial) Electrical characteristics 750 Vrms for 1min. (Detection current: 10mA) 1,800 Vrms for 1min. (Detection current: 10mA) 1,000 Vrms for 1min. (Detection current: 10mA) Surge breakdown voltage (Initial) Between open contacts Between contacts and coil 1,500 V (10160s) (FCC Part 68) 2,500 V (210s) (Telcordia) Max. 50C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.) Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Release time [Reset time] (at 20C 68F) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical Shock resistance Conditions Conditions for operation, transport and storage*2 Max. operating speed (at rated load) Unit weight *1 *2 Min. 1,000M (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. Between open contacts Between contact and coil Between contact sets Operate time [Set time] (at 20C 68F) Expected life 10A 10mV DC 50 mW (1.5 to 12 V DC), 70 mW (24 V DC) 35 mW (1.5 to 12 V DC), 50 mW (24 V DC) 70 mW (1.5 to 12 V DC), 150 mW (24 V DC) Breakdown voltage (Initial) Temperature rise (at 20C 68F) Mechanical characteristics Specifications 2 Form C Max. 100 m (By voltage drop 6 V DC 1A) Standard contact: Ag+Au clad, AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable) 1 A 30 V DC (resistive load) 30 W (DC) (resistive load) 110V DC 1A Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 5 mm Min. 5107 (at 180 times/min.) Min. 2105 (1 A 30 V DC resistive) (at 20 times/min.) Ambient temperature: –40C to +70C –40F to +158F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. Approx. 2 g .071 oz This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level].) Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information. ds_61022_en_txs: 280114D 3 TX-S REFERENCE DATA 1. Maximum switching capacity 2. Life curve 3. Mechanical life 1.0 0.5 0.4 Ratio against the rated voltage, %V DC resistive load (cosφ = 1) No. of operations x104 Contact current, A Tested sample: TXS2-4.5V, 10 pcs. Operating speed: 180 times/min. 30V DC resistive load 100 10 0.3 0.2 100 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 30 0 100 200 Contact voltage, V 0.5 0 1.0 Switching current, A 10 100 1,000 5,000 No. of operations, ×104 4. Electrical life (1 A 30 V DC resistive load) 5-(1). Coil temperature rise Tested sample: TXS2-4.5V, 6 pcs. Operating speed: 20 times/min. Tested sample: TXS2-4.5V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25C 77F, 70C 158F Change of contact resistance 100 90 90 80 Pick-up voltage 70 Max. Min. 60 50 40 Room temperature :x +70°C +158°F :x 80 70 60 50 Max. 40 30 30 Drop-out voltage 20 Max. Min. Min. 20 1A 1A 0A 0A 10 20 10 10 0 30 Temperature rise, °C 100 Contact resistance, mΩ Ratio against the rated voltage, %V Change of pick-up and drop-out voltage 0 5 10 15 0 20 No. of operations, ×10 0 0 5 10 20 15 No. of operations, ×10 4 90 100 110 120 130 140 150 160 Coil applied voltage, %V 4 5-(2). Coil temperature rise 6-(1). Operate and release time (with diode) 6-(2). Operate and release time (without diode) Tested sample: TXS2-24V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25C 77F, 70C 158F Tested sample: TXS2-4.5V, 10 pcs. Tested sample: TXS2-4.5V, 10 pcs. 30 20 1A 1A 0A 0A 10 Operate time Release time 6 5 4 3 2 Max. Min. Max. Min. Operate and release time, ms Operate and release time, ms Temperature rise, °C 7 7 Room temperature :x +70°C +158°F :x 90 100 110 120 130 140 150 0 160 Coil applied voltage, %V Rate of change, % Tested sample: TXS2-4.5V, 5 pcs. –40 –20 0 30 20 Drop-out voltage x x 10 Pick-up voltage 20 40 60 80 Ambient –10 temperature, °C Max. Min. 3 2 0 90 110 120 100 Coil applied voltage, %V Max. Min. 80 90 100 110 120 Coil applied voltage, %V 8-(2). High frequency characteristics (Insertion loss) Tested sample: TXS2-4.5V, 2 pcs. Tested sample: TXS2-4.5V, 2 pcs. 100 50 1.0 0.8 0.6 0.4 –20 0.2 –30 10 100 Frequency, MHz 4 4 8-(1). High frequency characteristics (Isolation) Isolation, dB 7. Ambient temperature characteristics 80 Insertion loss, dB 0 5 1 1 Operate time Release time 6 1,000 10 100 Frequency, MHz 1,000 ds_61022_en_txs: 280114D TX-S 9-(1). Malfunctional shock (single side stable) 9-(2). Malfunctional shock (latching) 10. Thermal electromotive force Tested sample: TXS2-4.5V, 6 pcs. Tested sample: TXS2-L2-4.5V, 6 pcs. Tested sample: TXS2-4.5V, 6 pcs. X’ Y Y’ Y Deenergized condition Energized condition X Z Z’ 2 X 1000m/s2 Z 1000m/s2 1000m/s2 Z’ 1000m/s2 X’ 20 Reset state Set state Y x = 0.30 18 2 Y Y’ 1000m/s X’ 1000m/s 16 X 1000m/s2 Z 1000m/s2 1000m/s2 Z’ 1000m/s2 X’ 1000m/s2 Y’ 14 Quantity X Z Z’ 12 10 8 6 4 1000m/s2 Y’ 2 0 0 0.15 0.25 0.35 0.45 0.55 Thermal electromotive force, μV 11-(2). Influence of adjacent mounting 11-(3). Influence of adjacent mounting Tested sample: TXS2-4.5V, 6 pcs. Tested sample: TXS2-4.5V, 6 pcs. Tested sample: TXS2-4.5V, 6 pcs. 10 5 Pick-up voltage ON Rate of change, % Drop-out voltage OFF OFF –5 OFF –15 ON 10 ON 5 Pick-up voltage ON 0 Drop-out voltage 0 –5 –15 2 4 6 8 10 12 14 16 .079 .157 .236 .315 .394 .472 .551 .630 Inter-relay distance , mm inch 12. Pulse dialing test + 0.08 μF DC48V – 458Ω 0.08 μF 458Ω Wire spring relay OFF 4 3 Pick-up voltage ON ON Drop-out voltage OFF –5 OFF 2 4 6 8 10 12 14 16 .079 .157 .236 .315 .394 .472 .551 .630 Inter-relay distance , mm inch OFF 0 OFF 2 4 6 8 10 12 14 16 .079 .157 .236 .315 .394 .472 .551 .630 Inter-relay distance , mm inch Change of contact resistance 100 100 90 80 Pick-up voltage Max. Min. 70 60 50 40 Drop-out voltage 30 Max. Min. 20 10 0 ON 5 –15 Change of pick-up and drop-out voltage (35 mA 48V DC wire spring relay load) Tested sample: TXS2-4.5V, 6 pcs. ON 10 –10 OFF 0 15 0 OFF –10 –10 Ratio against the rated voltage, %V Rate of change, % 0 15 Rate of change, % ON Rate of change, % ON Contact resistance, mΩ 15 Rate of change, % Rate of change, % 11-(1). Influence of adjacent mounting 90 80 70 60 50 40 Max. 30 Min. 20 10 0 10 20 30 40 50 No. of operation, ×10 4 0 0 10 20 30 40 50 No. of operation, ×104 Note: Data of surface-mount type are the same as those of PC board terminal type. ds_61022_en_txs: 280114D 5 TX-S DIMENSIONS (mm inch) CAD Data Data from our Web site. Download CAD 1. Standard PC board terminal CAD Data External dimensions (General tolerance: 0.3 .012) Single side stable and 2 coil latching type (L2, LT) 1 coil latching type Type 15.00 .591 7.40 .291 7.40 .291 15.00 .591 0.50 .020 1.15 .045 5.08 .200 3.50 .138 2.54 .100 0.50 .020 1.15 .045 0.25 5.08 .010 .200 10.16 .400 2.54 .100 0.65 .026 8.20 .323 0.65 8.20 .026 .323 Standard PC board terminal PC board pattern (Bottom view) (Tolerance: 0.1 .004) Single side stable and 1 coil latching type 2 coil latching type (L2, LT) 12.7 .500 2.54 .100 5.08 .200 5.08 .200 0.25 5.08 .010 .200 3.50 .138 2.54 .100 8-1.0 dia. 8-.039 dia. 5.08 .200 10-1.0 dia. 10-.039 dia. Schematic (Bottom view) Single side stable + – 1 12 1 coil latching 3 4 5 – + 10 9 8 Direction indication 1 2 coil latching (L2) 3 4 5 12 10 9 8 Direction indication (Deenergized condition) 1 3 4 5 6 + – + – 12 10 9 8 7 2 coil latching (LT) + – 12 Direction indication (Reset condition) 1 3 4 5 6 10 9 8 7 + – Direction indication (Reset condition) (Reset condition) 2. Surface-mount terminal CAD Data External dimensions (General tolerance: 0.3 .012) Single side stable and 2 coil latching type (L2, LT) 1 coil latching type Type 15 .591 8.2 8.4 .323 .331 SA type 0.5 .020 0.65 .026 5.08 .200 15 .591 7.4 .291 5.08 .200 9.4±0.5 .370±.020 2.54 .100 15 .591 8.2 8.4 .323 .331 0.65 .026 5.08 .200 2.54 .100 0.65 .026 0.5 .020 5.08 .200 0.25 .010 0.65 .026 0.5 .020 5.08 .200 2.54 .100 2.54 .100 2 coil latching type (L2, LT) 1 3.16 .039 .124 5.08 .200 2.54 .100 7.24 .285 7.24 .285 1 2.16 .039 .085 5.08 .200 7.4±0.5 .291±.020 5.08 .200 0.25 .010 8.2 Max.10 .323 .394 5.08 .200 7.4±0.5 .291±.020 2.54 .100 1 3.16 .039 .124 7.4 .291 8.2 Max.10 .323 .394 SS type 5.08 .200 9.4±0.5 .370±.020 15 .591 7.4 .291 Single side stable and 1 coil latching type 7.4 .291 0.25 .010 0.5 .020 Suggested mounting pad (Top view) (Tolerance: 0.1 .004) 0.25 .010 5.08 .200 2.54 .100 1 2.16 .085 .039 6.24 .246 5.08 .200 2.54 .100 6.24 .246 Schematic (Top view) Single side stable 12 10 9 8 1 3 4 5 Direction indication (Deenergized condition) 6 1 coil latching 12 10 9 8 1 3 4 5 Direction indication (Reset condition) 2 coil latching (L2) 12 10 9 8 7 1 3 4 5 6 Direction indication (Reset condition) 2 coil latching (LT) 12 10 9 8 7 1 3 4 5 6 Direction indication (Reset condition) ds_61022_en_txs: 280114D TX-S NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1) stripe Stopper (gray) Stopper (green) 2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type 2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500gf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less A C B mm inch 1.5 +0.1 0 dia. Relay polarity bar .059 +.004 dia. 2.0 0 (Z type) .079 1.75 .069 4.0 .157 0.4 .016 C A B 11.5 .453 D 16.0 10.0 .394 .630 Relays 15.5 .610 24.0 ±0.3 ±0.2 .945 ±.012 9.2±.008 .362 Tape coming out direction Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. (ii) SS type mm inch 1.5 +0.1 0 dia. Relay polarity bar .059 +.004 dia. 2.0 0 (Z type) .079 4.0 .157 1.75 .069 0.4 .016 11.5 .453 15.5 .610 16.0 .630 Relays Tape coming out direction 8.0 24.0 ±0.3 ±.012 .315 .945 10.8±0.2 .425±.008 (2) Dimensions of plastic reel mm inch 2.0 .079 13 dia. .512 dia. 21 dia. .827 dia. 380 dia. 14.961 dia. 80 dia. 3.150 dia. For Cautions for Use, see Relay Technical Information. ds_61022_en_txs: 280114D 7