Preview only show first 10 pages with watermark. For full document please download

Tx-s Relays Tx-s Features Very High Sensitivity,

   EMBED


Share

Transcript

TX-S Very High Sensitivity, 50 mW (nominal operating) Relay with LT style pin layout TX-S RELAYS FEATURES 1. Nominal operating power: High sensitivity of 50mW By using the highly efficient polar magnetic circuit “seesaw balance mechanism”, a nominal operating power of 50 mW (minimum operating power of 32 mW) has been achieved. 2. Compact size 15.0(L) × 7.4(W) × 8.2(H) .591(L) × .291(W) × .323(H) 3. High contact reliability High contact reliability is achieved by the use of gold-clad twin crossbar contacts, low-gas formation materials, mold sealing the coil section, and by controlling organic gas in the coil. *We also offer a range of products with AgPd contacts suitable for use in low level load analog circuits (Max. 10V DC 10 mA). 4. Outstanding surge resistance. Surge breakdown voltage between open contacts: 1,500 V 10×160 µsec. (FCC part 68) Surge breakdown voltage between contact and coil: 2,500 V 2×10 µsec. (Telcordia) RoHS compliant 5. Low thermal electromotive force (approx. 0.3 µV) The structure of the mold-sealed body block of the coil section achieves nominal operating power of 50 mW and high sensitivity, along with low thermal electromotive force, reduced to approximately 0.3 µV. 6. Sealed construction allows automatic washing. TYPICAL APPLICATIONS 1. Communications (XDSL, Transmission) 2. Measurement 3. Security 4. Home appliances, and audio/visual equipment 5. Medical equipment ORDERING INFORMATION TXS 2 Contact arrangement 2: 2 Form C Surface-mount availability Nil: Standard PC board terminal type SA: SA type Operating function Nil: Single side stable LT: 2 coil latching Terminal shape Nil: Standard PC board terminal or surface-mount terminal Nominal coil voltage (DC) 3, 4.5, 6, 9, 12, 24V Contact material Nil: Standard contact (Ag+Au clad) 1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable) Packing style Nil: Tube packing X: Tape and reel (picked from 1/3/4/5-pin side) Z: Tape and reel packing (picked from the 8/9/10/12-pin side) ASCTB15E 201209-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ TX-S TYPES 1. Standard PC board terminal Contact arrangement Nominal coil voltage 2 Form C 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. TXS2-3V TXS2-4.5V TXS2-6V TXS2-9V TXS2-12V TXS2-24V 2 coil latching Part No. TXS2-LT-3V TXS2-LT-4.5V TXS2-LT-6V TXS2-LT-9V TXS2-LT-12V TXS2-LT-24V Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load). 2. Surface-mount terminal 1) Tube packing Contact arrangement Nominal coil voltage 2 Form C 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. TXS2SA-3V TXS2SA-4.5V TXS2SA-6V TXS2SA-9V TXS2SA-12V TXS2SA-24V 2 coil latching Part No. TXS2SA-LT-3V TXS2SA-LT-4.5V TXS2SA-LT-6V TXS2SA-LT-9V TXS2SA-LT-12V TXS2SA-LT-24V Standard packing: Tube: 40 pcs.; Case: 1,000 pcs. Note: Please add “-1” to the end of the part number for AgPd contacts (low level load). 2) Tape and reel packing Contact arrangement Nominal coil voltage 2 Form C 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC Single side stable Part No. TXS2SA-3V-Z TXS2SA-4.5V-Z TXS2SA-6V-Z TXS2SA-9V-Z TXS2SA-12V-Z TXS2SA-24V-Z 2 coil latching Part No. TXS2SA-LT-3V-Z TXS2SA-LT-4.5V-Z TXS2SA-LT-6V-Z TXS2SA-LT-9V-Z TXS2SA-LT-12V-Z TXS2SA-LT-24V-Z Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. 2. Please add “-1” to the end of the part number for AgPd contacts (low level load). (Ex. TXS2SA-3V-1-Z) RATING 1. Coil data 1) Single side stable Nominal operating current [±10%] (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) 3V DC 16.7mA 180Ω 4.5V DC 6V DC 9V DC 12V DC 24V DC 11.1mA 8.3mA 5.6mA 4.2mA 2.9mA 405Ω 720Ω 1,620Ω 2,880Ω 8,229Ω Nominal coil voltage Pick-up voltage (at 20°C 68°F) 80%V or less of nominal voltage* (Initial) Drop-out voltage (at 20°C 68°F) 10%V or more of nominal voltage* (Initial) Nominal operating power Max. applied voltage (at 20°C 68°F) 50mW 150%V of nominal voltage 70mW 2) 2 coil latching Nominal coil voltage Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) 3V DC 4.5V DC 6V DC 9V DC 12V DC 24V DC 80%V or less of nominal voltage* (Initial) 80%V or less of nominal voltage* (Initial) Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil Coil resistance [±10%] (at 20°C 68°F) Set coil Reset coil 23.3mA 23.3mA 129Ω 129Ω 15.6mA 11.7mA 7.8mA 5.8mA 6.3mA 15.6mA 11.7mA 7.8mA 5.8mA 6.3mA 289Ω 514Ω 1,157Ω 2,057Ω 3,840Ω 289Ω 514Ω 1,157Ω 2,057Ω 3,840Ω Nominal operating power Set coil Reset coil 70mW 70mW 150mW 150mW Max. applied voltage (at 20°C 68°F) 150%V of nominal voltage *Pulse drive (JIS C 5442-1986) Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB15E 201209-T TX-S 2. Specifications Characteristics Contact Item Arrangement Initial contact resistance, max. Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Specifications 2 Form C Max. 100 mΩ (By voltage drop 6 V DC 1A) Standard contact: Ag+Au clad, AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable) 1 A 30 V DC (resistive load) 30 W (DC) (resistive load) 110V DC 1A 10µA 10mV DC Single side stable 2 coil latching Insulation resistance (Initial) 50 mW (3 to 12 V DC), 70 mW (24 V DC) 70 mW (3 to 12 V DC), 150 mW (24 V DC) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. Contact material Rating Nominal operating power Electrical characteristics Breakdown voltage (Initial) Between open contacts Between contact and coil Between contact sets 750 Vrms for 1min. (Detection current: 10mA) 1,800 Vrms for 1min. (Detection current: 10mA) 1,000 Vrms for 1min. (Detection current: 10mA) Surge breakdown voltage (Initial) Between open contacts Between contacts and coil 1,500 V (10×160µs) (FCC Part 68) 2,500 V (2×10µs) (Telcordia) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.) Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 5 mm Min. 5×107 (at 180 cpm) Min. 2×105 (1 A 30 V DC resistive) (at 20 cpm) Ambient temperature: –40°C to +70°C –40°F to +158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 2 g .071 oz Temperature rise (at 20°C 68°F) Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical Shock resistance Mechanical characteristics Expected life Conditions Conditions for operation, transport and storage*2 Max. operating speed (at rated load) Unit weight Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level]) *2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). REFERENCE DATA 1. Maximum switching capacity 2. Life curve 3. Mechanical life 1.0 0.5 0.4 0.3 100 30V DC resistive load 10 0.2 Ratio against the rated voltage, %V DC resistive load (cosφ = 1) No. of operations ×104 Contact current, A Tested sample: TXS2-4.5V, 10 pcs. Operating speed: 180 cpm 100 90 80 Pick-up voltage 70 60 Max. Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 30 ASCTB15E 201209-T 100 200 Contact voltage, V 0 Panasonic Corporation 0.5 1.0 Switching current, A Automation Controls Business Unit 0 10 100 1,000 5,000 No. of operations, ×104 industrial.panasonic.com/ac/e/ TX-S 4. Electrical life (1 A 30 V DC resistive load) 5-(1). Coil temperature rise Tested sample: TXS2-4.5V, 6 pcs. Operating speed: 20 cpm Tested sample: TXS2-4.5V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F, 70°C 158°F Change of contact resistance 100 90 90 80 Pick-up voltage 70 Max. Min. 60 50 40 30 80 70 60 50 Max. 40 Max. Min. 20 1A 1A 0A 0A 10 Min. 20 10 0 Room temperature :x +70°C +158°F :x 30 Drop-out voltage 20 30 Temperature rise, °C 100 Contact resistance, mΩ Ratio against the rated voltage, %V Change of pick-up and drop-out voltage 10 0 5 10 0 20 15 0 5 No. of operations, ×104 10 0 20 15 90 100 110 No. of operations, ×104 120 130 140 150 160 Coil applied voltage, %V 5-(2). Coil temperature rise 6-(1). Operate and release time (with diode) 6-(2). Operate and release time (without diode) Tested sample: TXS2-24V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F, 70°C 158°F Tested sample: TXS2-4.5V, 10 pcs. Tested sample: TXS2-4.5V, 10 pcs. 7 20 1A 1A 0A 0A 10 7 Operate time Release time 6 5 4 3 2 Max. Min. Max. Min. Operate and release time, ms Temperature rise, °C Room temperature :x +70°C +158°F :x Operate and release time, ms 30 1 0 130 120 140 150 80 160 20 Drop-out voltage x x 10 Pick-up voltage 0 20 40 60 80 Ambient –10 temperature, °C 2 Max. Min. 80 90 100 110 8-(2). High frequency characteristics (Insertion loss) Tested sample: TXS2-4.5V, 2 pcs. Tested sample: TXS2-4.5V, 2 pcs. 100 50 1.0 0.8 0.6 –20 0.4 –30 0.2 10 100 1,000 10 Frequency, MHz 100 Frequency, MHz 9-(1). Malfunctional shock (single side stable) 9-(2). Malfunctional shock (latching) 10. Thermal electromotive force Tested sample: TXS2-4.5V, 6 pcs. Tested sample: TXS2-LT-4.5V, 6 pcs. Tested sample: TXS2-4.5V, 6 pcs. X’ Deenergized condition Energized condition Y 1000m/s 2 Y Y’ X Z 1000m/s2 1000m/s2 1000m/s Z’ X Z Z’ 2 1000m/s X’ 2 X’ 1000m/s x = 0.30 18 16 X Z 1000m/s2 1000m/s2 1000m/s Z’ 1,000 20 Reset state Set state Y 2 2 1000m/s X’ 2 Quantity X Z Z’ Y Y’ 120 Coil applied voltage, %V Insertion loss, dB –40 –20 30 Min. 3 8-(1). High frequency characteristics (Isolation) Isolation, dB Rate of change, % Tested sample: TXS2-4.5V, 5 pcs. Max. 4 0 100 90 110 120 Coil applied voltage, %V Coil applied voltage, %V 7. Ambient temperature characteristics 5 1 0 90 100 110 Operate time Release time 6 14 12 10 8 6 4 1000m/s Y’ 2 1000m/s Y’ 2 2 0 0 0.15 0.25 0.35 0.45 0.55 Thermal electromotive force, µV Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB15E 201209-T TX-S 11-(2). Influence of adjacent mounting 11-(3). Influence of adjacent mounting Tested sample: TXS2-4.5V, 6 pcs. Tested sample: TXS2-4.5V, 6 pcs. Tested sample: TXS2-4.5V, 6 pcs. ON 10 5 Pick-up voltage ON Drop-out voltage Rate of change, % Rate of change, % 0 OFF OFF –5 OFF –15 ON 10 ON 5 Pick-up voltage ON 0 Drop-out voltage 0 –5 –15 2 4 6 8 10 12 14 16 .079 .157 .236 .315 .394 .472 .551 .630 Inter-relay distance , mm inch ON 10 ON 5 Pick-up voltage ON ON Drop-out voltage OFF –5 OFF –10 OFF OFF 0 15 0 OFF –10 –10 Rate of change, % ON 15 Rate of change, % 15 Rate of change, % Rate of change, % 11-(1). Influence of adjacent mounting –15 2 4 6 8 10 12 14 16 .079 .157 .236 .315 .394 .472 .551 .630 Inter-relay distance , mm inch OFF 0 OFF 2 4 6 8 10 12 14 16 .079 .157 .236 .315 .394 .472 .551 .630 Inter-relay distance , mm inch 12. Pulse dialing test (35 mA 48V DC wire spring relay load) Tested sample: TXS2-4.5V, 6 pcs. 458Ω + 0.08 µF DC48V – 0.08 µF 4 3 458Ω Wire spring relay Change of contact resistance 100 100 90 90 80 Contact resistance, mΩ Ratio against the rated voltage, %V Change of pick-up and drop-out voltage Pick-up voltage Max. Min. 70 60 50 40 Drop-out voltage 30 Max. Min. 20 70 60 50 40 Max. 30 Min. 20 10 0 80 10 10 0 20 30 40 0 50 No. of operation, ×104 0 10 20 30 50 40 No. of operation, ×104 Note: Data of surface-mount type are the same as those of PC board terminal type. DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1. Standard PC board terminal and Self clinching terminal CAD Data External dimensions (General tolerance: ±0.3 ±.012) Single side stable type 2 coil latching type Type 15.00 .591 7.40 .291 Standard PC board terminal 7.40 .291 15.00 .591 10.16 .400 2.54 .100 0.65 .026 8.20 .323 0.65 8.20 .026 .323 PC board pattern (Bottom view) (Tolerance: ±0.1 ±.004) Single side stable type 2 coil latching type 2.54 .100 12.7 .500 5.08 .200 0.50 .020 1.15 .045 5.08 .200 3.50 .138 2.54 .100 0.50 .020 1.15 .045 0.25 5.08 .010 .200 5.08 .200 2.54 .100 3.50 .138 0.25 5.08 .010 .200 8-1.0 dia. 8-.039 dia. 5.08 .200 10-1.0 dia. 10-.039 dia. Schematic (Bottom view) Single side stable + – 1 3 4 5 12 10 9 8 Direction indication (Deenergized condition) ASCTB15E 201209-T 2 coil latching + 1 – 12 3 4 5 6 10 9 8 7 + – Direction indication (Reset condition) Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ TX-S 2. Surface-mount terminal CAD Data External dimensions (General tolerance: ±0.3 ±.012) Single side stable type 2 coil latching type Type 15 .591 15 .591 7.4 .291 8.2 8.4 .323 .331 SA type 0.5 .020 0.65 .026 5.08 .200 2.54 .100 7.4 .291 8.2 8.4 .323 .331 0.25 .010 5.08 .200 9.4±0.5 .370±.020 Suggested mounting pad (Top view) (Tolerance: ±0.1 ±.004) Single side stable type 2 coil latching type 0.5 .020 0.65 .026 5.08 .200 5.08 .200 9.4±0.5 .370±.020 2.54 .100 1 3.16 .039 .124 0.25 .010 5.08 .200 2.54 .100 1 3.16 .039 .124 7.24 .285 5.08 .200 2.54 .100 7.24 .285 Schematic (Top view) Single side stable 12 10 9 8 1 3 4 5 2 coil latching 12 10 9 8 7 1 3 4 5 6 Direction indication Direction indication (Deenergized condition) (Reset condition) NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1) stripe Stopper (gray) Stopper (green) 2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions 2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500gf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less A C B mm inch 1.5 Relay polarity bar .059 (Z type) +0.1 0 +.004 0 dia. dia. 2.0 .079 1.75 .069 4.0 .157 0.4 .016 C A Relays B 11.5 .453 D 16.0 10.0 .394 .630 15.5 .610 24.0 ±0.3 ±0.2 .945 ±.012 9.2±.008 .362 Tape coming out direction (2) Dimensions of plastic reel mm inch 2.0 .079 13 dia. .512 dia. 21 dia. .827 dia. Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”. 380 dia. 14.961 dia. 80 dia. 3.150 dia. Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB15E 201209-T