Preview only show first 10 pages with watermark. For full document please download

Type P Drilmar(tm) 125-xe Power Cable, 3 Conductors, 2000 Volts

   EMBED


Share

Transcript

Type P Drilmar® 125-XE VFD Power Cable, 3 Conductors     Crosslinked Polyolefin Insulated, Drilling Rig and Marine Cable, 2000 V Application Engineered for easiest installation. Extra flexible stranding meets IEEE, UL, and CSA requirements. For use in variable frequency AC motor driver (VFD) applications. Flexible conductors for easy handling and installation, with an overall composite shield forme by a copper wire braid and an aluminum foil shield providing a 100% coverage, to contain the VFD EMI emissions, and with grounding conductors distributed symmetrical to reduce induced voltage imbalances and carry common mode noise back to the drive. Maximum conductor operating temperature: 100 °C as Type P per IEEE, and 110°C as Type X110 per UL and CSA. Meets ampacity ratings per ABS, DNV, LRS, and TCMS. DRILMAR® XLPO Insulation: • Superior oil and chemical resistance. • Sunlight resistant. • Rated at 125 ºC. • Passes Cold Bend at -55 ºC. Heavy Duty CPE Jacket: • Arctic Type XE design. • Abrasion and sunlight resistant. • Rated at 90 ºC. Completed cable offers superior flame resistance meeting: • 70,000 Btu Flame Tests IEEE 1202/FT4, IEEE 383, UL 1685, ICEA T-30-820, and IEC 332 Category A. • 210,000 Btu Flame Test ICEA T-29-520. Arctic Type design meets Cold Bend and Impact Tests at -40 ºC, exceeding the Transport Canada Marine Safety requirements. Cables meet applicable requirements of IEC 92-350. Standards IEEE 1580-2001 Recommended Practice for Marine Cable for Use on Shipboard and Fixed and Floating Platforms. UL 1309-1995 Marine Shipboard Cable. CSA C22.2 No. 245 Marine Shipboard Cable. IEEE 45-2002 Recommended Practice for Electrical Installations on Shipboard Cable. Approvals • UL and CSA, as Type P. • UL and CSA, as Type X110. • ABS, American Bureau of Shipping. • DNV, Det Norske Veritas • LRS, Lloyd’s Register of Shipping. • United States Coast Guard. • TCMS, Transport Canada Marine Safey. Engineering Information 1. Conductor: Soft annealed flexible Tin Coated Copper per IEEE, UL, and CSA. Sizes: 4 AWG up to 535.3 kcmil. 2. Separator Tape: Polyester tape as required. 1 2 3 4 5 6 7 8 3. Insulation: Flame retardant and sunlight resistant Crosslinked Polyolefin (XLPO) per IEEE. Also meets and exceeds the requirements of UL and CSA for Type X110. DRILMAR® 125-XE is a 125 °C XLPO. Rated 2 kV for power cables. 4. Grounding Conductors (x3): Three soft Annealed flexible Tin Coated Copper green insulated conductors symmetrically distributed. Rated 600/1000 volts for grounding conductors. Identification: Power cables Dark Gray with numbers. Grounding conductors Green with numbers. Assembly: Power and grounding conductors cabled round with moisture and flame retardant fillers, as required and binder tape. 5. Shield: Overall tinned copper braid plus aluminum foil/polyester tape providing 100% coverage. A binder tape is used over the shield as required. 6. CPE Jacket: Flame retardant and sunlight resistant Arctic Type Chlorosulfonated Polyethylene (CP) per IEEE, UL and CSA. 7. Armor (optional): StandardBronze. A binder tape is used over the armor as required. Optional - Aluminum or Tinned Copper Braid per IEEE, UL and CSA. 8. Overall Jacket (optional): Flame retardant and sunlight resistant Arctic Type Chlorinated Polyethylene (CPE) per IEEE, UL, and CSA. CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | www.cmewire.com | 770.623.0001 © 2014 CME Wire and Cable, Inc. All Rights Reserved. July 7, 2017 Drilmar® Marine Cable Features Type P  Drilmar® 125-XE  VFD Power Cable, 3 Conductors, 2000 V Technical Data Type P VFD Power Cable, 3 Conductors, 2000 V Conductor Size AWG / kcmil DTVPCP Unarmored Nominal OD Strands in mm Part Number 4 105 1.11 28 2 154 1.23 31 1 224 1.42 1/0 273 2/0 323 3/0 Armored Aluminum Nominal OD Net Weight lb/kft kg/km in mm Part Number DTVPCP41-3 933 1388 1.16 29 DTVPCP66-3 1243 1850 1.28 33 36 DTVPCP83-3 1651 2457 1.48 1.51 38 DTVPCP105-3 1896 2822 1.63 41 DTVPCP133-3 2178 3241 456 1.89 48 DTVPCP167-3 3084 Bronze Net Weight Net Weight lb/kft kg/km Part Number lb/kft kg/km DTVPCPA41-3 987 1469 DTVPCPB41-3 1110 1652 DTVPCPA66-3 1303 1939 DTVPCPB66-3 1439 2141 37 DTVPCPA83-3 1720 2560 DTVPCPB83-3 1877 2793 1.56 40 DTVPCPA105-3 1969 2930 DTVPCPB105-3 2136 3179 1.69 43 DTVPCPA133-3 2258 3360 DTVPCPB133-3 2437 3627 4589 1.95 49 DTVPCPA167-3 3176 4726 DTVPCPB167-3 3384 5036 4/0 551 2.21 56 DTVPCP211-3 3783 5630 2.26 57 DTVPCPA211-3 3890 5789 DTVPCPB211-3 4132 6149 262.6 646 2.32 59 DTVPCP262-3 4376 6512 2.37 60 DTVPCPA262-3 4488 6679 DTVPCPB262-3 4742 7057 313.1 779 2.48 63 DTVPCP313-3 5096 7584 2.53 64 DTVPCPA313-3 5216 7762 DTVPCPB313-3 5487 8166 373.7 925 2.62 67 DTVPCP373-3 5809 8645 2.68 68 DTVPCPA373-3 5936 8834 DTVPCPB373-3 6223 9261 444.4 1110 2.80 71 DTVPCP444-3 6701 9972 2.85 72 DTVPCPA444-3 6836 10173 DTVPCPB444-3 7141 10627 535.3 1332 3.11 79 DTVPCP535-3 8106 12063 — — — — — — — — The above data are approximate and subject to normal manufacturing tolerances. Where required, the compatibility with glands, connectors and accessories should be verified using actual dimensions of the product. Ampacities: Refer to beginning of section. Conductor Armored and Sheathed Aluminum Size AWG / kcmil Nominal OD Bronze Net Weight Net Weight Strands in mm Part Number lb/kft kg/km Part Number lb/kft kg/km 4 105 1.34 34 DTVPCPAS41-3 1207 1796 DTVPCPBS41-3 1329 1978 2 154 1.46 37 DTVPCPAS66-3 1544 2298 DTVPCPBS66-3 1680 2500 1 224 1.65 42 DTVPCPAS83-3 1995 2969 DTVPCPBS83-3 2152 3203 1/0 273 1.81 46 DTVPCPAS105-3 2372 3530 DTVPCPBS105-3 2538 3777 2/0 323 1.93 49 DTVPCPAS133-3 2689 4002 DTVPCPBS133-3 2869 4270 3/0 456 2.19 56 DTVPCPAS167-3 3670 5462 DTVPCPBS167-3 3878 5771 4/0 551 2.50 64 DTVPCPAS211-3 4459 6636 DTVPCPBS211-3 4700 6994 262.6 646 2.62 66 DTVPCPAS262-3 5084 7566 DTVPCPBS262-3 5338 7944 313.1 779 2.77 70 DTVPCPAS313-3 5849 8704 DTVPCPBS313-3 6120 9108 373.7 925 2.99 76 DTVPCPAS373-3 6797 10115 DTVPCPBS373-3 7083 10541 444.4 1110 3.10 79 DTVPCPAS444-3 7677 11425 DTVPCPBS444-3 7975 11868 The above data are approximate and subject to normal manufacturing tolerances. Where required, the compatibility with glands, connectors and accessories should be verified using actual dimensions of the product. Ampacities: Refer to beginning of section. CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | www.cmewire.com | 770.623.0001 July 7, 2017 © 2014 CME Wire and Cable, Inc. All Rights Reserved.