TZ Praetorian™ Junction Model Numbers: 7140 AF and 7141 AF
ixp.tz.net
The TZ Praetorian Junction interprets relay output signals from building access control systems and converts them into RS485 serial data signals to communicate with TZ locking devices and also to supervise door position sensors, detect intrusions and override key door opening which are reported back to the building access control system through its associated relay inputs. The TZ Praetorian Junction includes quick connect pluggable termination blocks for either 12 or 24 connections to the relay I/O cards of building access control systems. It can be mounted in a 19” 1U rack space or on a wall convenient to the access control system and the structured cable patch panel. RS 485 data communication and power is provided for one or two TZ Praetorian Triggers and either 12 or 24 RJ45 ports that connect and provide power to TZ locking devices through structured category cabling.
Features
Benefits > Extends third party access control systems to provide more granular levels of security and auditable access records for PCI-DSS, HIPPA, NERC CIP and other regulatory mandates. > Allows existing third party access control systems to secure a broad range of Datacenter, IT, medical and Industrial cabinets and enclosures. > TZ locking devices do not require additional in-cabinet power, which reduces and installation time.
> Compatible with TIA/EIA structured cabling standards.
> Allows many locks to be controlled from a single credential reader.
> Quick connect style connections for 12 - 24 relay I/O from access controller.
> Capable of controlling multiple locks with one relay input.
> RJ45 with cat 5e/6 cable connections for power and data to 12 or 24 TZ locking devices. > RJ45 connections for power and data to one or two TZ Praetorian Triggers.
> Scalable system accommodates any size installation. > Serves multiple cabinets – up to 12 x two door cabinets and saves valuable in-cabinet rack space compared to other systems.
> Wide range of input voltage: 90 to 250 VAC, 50 to 60Hz. > Versions available to connect 12 or 24 TZ locking devices. > Flexible mounting options for rack, wall, or shelf to simplify installation.
A TZ Business | ixp.tz.net | © 2015 | 112278.01_F TZ® and TZ Praetorian™ are trademarks of TZ Limited
TZ Pra aetorian n™ Jun nction Mo odel Numberrs: 7140AF | 7141AF
ixp.tz.net
specifica ations overview Specifica ations subject to t change to suit s particular application requirements physical and mountin ngs
Specifications Overview Dims: 43 34.4mm x 209 9.2mm x 43.7m mm (17.1” x 8.2” x 1.72”) Weight: 1.81 (4.0 lb bs) 2.5particular kg (5.5 lbs) Specifications subject tokg change to or suit application requirements. Mounting g: Standard 19 9” rack mounttable spacing or can be wall mounted usin ng the same brackets b
Physical And Mountings CAUTION N:
Electrical
of the This prod duct should no be installed in a way that compromises the Ingress P 100 to 240VAC, (IP) rating1A, e 60Hz, IEC C14 enclosure x 209.2mm xot43.7mm input:Protection 50 to > Dims: 434.4mm > Voltage in which it is mounted. Do not drill or o otherwise prroduce metal(1A, sshavings arou und electronic equipment. (17.1” x 8.2” x 1.72”) 250VAC, 5x20mm slow blow fuse included) mental pe erformance environm kg (4.0 lbs) and or 2.5 kg (5.5 lbs) > Weight: 1.81
> IEC C13 to NEMA 5-15 input cord included
g ambient tem mperature: C to +50°C (32 2°F to 122°F) Standard 19” rack mountable 0°C spacing or can > Mounting:Operating > RS-485 multi-drop communications interface via RJ-45
be wall mounted the same brackets Storage using t temperature: -15°C to +70°°C (5°F to 158 8°F)
2 to 80% RH H, non-condensing CAUTION: Humidity (operating): 20 This productIngress shouldprotection: not be installed in a way that p IP 20 compromises the Ingress Protection (IP) rating of the MTBF: 131,400 hrs @ 25 enclosure inEstimated which itd is mounted. Do not drill 5ºC or otherwise produce metal shavings around electronic equipment. electrica al
> 12 (model 7140AF) or 24 (model 7141AF) x RJ-45 connection to TZ locking devices > 1 (model 7140AF) or 2 (model 7141AF) x RJ-45 connection to TZ Praetorian Trigger devices > 12 (model 7140AF) or 24 (model 7141AF) x analog screw terminal I/O from controller: 2 input / 2 output
Voltage input: 100 to 240VAC, 2 1A, 50 5 to 60Hz, IE EC C14 (1A, 250VAC, 2 5x20mm slow blow w fuse included d)
Environmental and Performance
IEC C13 to NEMA 5-15 5 input cord in ncluded
> Operating ambient temperature: 0°C to +50°C RS-485 multi-drop m com mmunications interface via RJ-45 R (32°F to 122°F)
CAUTION: RJ-45 ports are not Ethernet compatible
TZ Praetorian Junction has no user-serviceable parts and should only be opened by qualified service personnel
12 (mode el 7140AF) or 24 (model 714 41AF) x RJ-45 5 connection to t TZ locking devices d
> Storage temperature: -15°C to +70°C (5°F to 158°F)
1 (model 7140AF) or 2 (model 7141A AF) x RJ-45 connection c to T TZ Praetorian™ Trigger dev vices
> Humidity (operating): 20 to 80% RH, non-condensing
Standards Compliance 12 (mode inal I/O from el 7140AF) or 24 (model 714 41AF) x analo og screw term controller: c 2 in nput / 2 outputt
IP 20 > Ingress protection: CAUTION N: RJ-45 portts are not Ethe ernet compatib ble
> FCC Part 15, CE, UL (c-us) per IEC/UL/CSA 60950-1 MTBF: 131,400Juncti hrs ion @ 25ºC > EstimatedTZ Praeto orian™ has no use er-serviceable e parts and> RoHS sho ould only be opened o by qua alified service compliant, personne el
> One Year Limited Warranty
standard ds complianc ce FCC Partt 15, CE, UL (c-us) per IEC//UL/CSA 6095 50-1 RoHS co ompliant, One Year Limited W Warranty
Dimensions (mm)
dimensio ons (mm)
hown 7141AF model sh
A TZ Business | ixp.ttz.net | © Telezygology, Inc. I 2011 A TZ Business | ixp.tz.net | © 2015 | 112278.01_F 112278.01_E ™ TZ® and TZ Praetorian are trademarks of TZ Limited