Preview only show first 10 pages with watermark. For full document please download

Ub12180fr

   EMBED


Share

Transcript

UPG No. 45568 Sealed Lead-Acid Battery Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567. UB12180FR Maintenance-Free Specification Nominal Voltage 12 volts 77º F (25º C) Nominal Capacity 20-hr. (0.90A) 18 Ah 10-hr. (1.67A) 16.74 Ah 5-hr. (3.06A) 15.30 Ah 1-hr. (10.80A) 10.80 Ah Approximate Weight 11.9 lbs (5.4 kgs) Internal Resistance (approx.) 18mŸ Shelf Life (% of normal capacity at 77º F (25º C)) 3 Months 6 Months 12 Months 91% 82% 64% (20 hour rate) Temperature Dependancy of Capacity 104º F 77º F 32º F 5º F 102% 100% 85% 65% FR=Flame Retardant, ABS, UL 94V-0 Characteristics AGM Operational Temperature -20 C to 45 C AGM Storage Temperature -20 C to 45 C Charge Method (Constant Voltage) Cycle Use (Repeating Use) Initial Current 5.4 A or smaller Control Voltage 14.5 - 14.9 V Float Use Control Voltage 13.6 - 13.8 V Physical Dimensions: in (mm) 181 (7.13) T4 12.3 3 12.5 5 5.5 77 (3.01) 165 (6.50) Terminals L: 7.13in (181.1 mm) W: 3.01in (76.5 mm) H: 6.50in (165.1 mm) TH: 6.57in (166.9 mm) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Discharge Characteristics Cell voltage ( V/Cell ) Discharge Time vs. Discharge Current ( Minute ) ( Hour ) Discharge time www.upgi.com 1720 Hayden Drive Carrollton, Texas 75006 Y1205-1 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected] UPG No. 45568 UB12180FR Maintenance-Free Battery Charging Characteristics for Standby Use Battery Charging Characteristics for Cyclic Use Cell charge voltage 1 Discharge 100 % (0.1CA*10h) --50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.275V/cell Charge current : 0.1CA (77 ) 3 Temperature : 25 Cell charge voltage ( V/Cell ) Charge volume (%) Charge volume Charge current (CA) Cell charge voltage ( V/Cell ) Charge current (CA) Charge volume (%) Cell charge voltage Charge volume 1 Discharge 100 % (0.1CA*10h) -- 50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.45V/cell Charge current : 0.3CA 3 Temperature : 25 (77 ) Charge current Charge current Charge Time (hr) Charge Time (hr) Shelf Life & Storage Cycle Life vs Depth of Discharge Open Circuit Voltage vs Residual Capacity Effect of Temperature on Capacity Charge Current & Final Discharge Voltage Application Charge Voltage(V/Cell) Set Point Allowable Range Cycle Use Temperature 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.30 2.27~2.30 Max.Charge Current Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 0.30C Discharge Current(A) 0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C Let UPG Power Your Life. www.upgi.com 1720 Hayden Drive Carrollton, Texas 75006 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]