Preview only show first 10 pages with watermark. For full document please download

Ub12350fr - National Battery

   EMBED


Share

Transcript

UPG No. D5880 Sealed Lead-Acid Battery Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567. UB12350FR Maintenance-Free Specification Nominal Voltage 12 volts 77º F (25º C) Nominal Capacity 20-hr. (1.75A) 35.00 Ah 10-hr. (3.25A) 32.50 Ah 5-hr. (5.95A) 29.70 Ah 1-hr. (21A) 21 Ah Approximate Weight 22.04 lbs (10.0 kgs) Internal Resistance (approx.) 12m Shelf Life (% of normal capacity at 77º F (25º C)) 3 Months 6 Months 12 Months 91% 82% 64% (20 hour rate) Temperature Dependancy of Capacity 104º F 77º F 32º F 5º F 102% 100% 85% 65% FR=Flame Retardant, ABS, UL 94V-0 Characteristics -20 C to 45 C AGM Operational Temperature AGM Storage Temperature -20 C to 45 C Charge Method (Constant Voltage) Cycle Use (Repeating Use) Initial Current 10.5A or smaller Control Voltage 14.4 - 14.9 V Float Use Control Voltage 13.5 - 13.8 V Physical Dimensions: in (mm) Terminals L: 7.75 in (196.9 mm) W: 5.19 in (131.83 mm) H: 6.14 in (156 mm) TH: 7.13 in (181.9 mm) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Discharge Time vs. Discharge Current Discharge Characteristics B attery D isch ar g in g C u rren t V S D isch ar g in g T im e Cell voltage ( V/Cell ) Battery discharge characteristics ( Minute ) ( Hour ) Discharge time www.upgi.com 1720 Hayden Drive Carrollton, Texas 75006 U1205-1 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected] UPG No. D5880 UB12350FR Maintenance-Free Battery Charging Characteristics for Cyclic Use Battery Charging Characteristics for Standby Use Battery Charging Characteristics For Cyclic Use Battery Charging Characteristics for Standby Use Cell charge voltage Cell charge voltage ( V/Cell ) 1 Discharge 100 % (0.1CA*10h) -- 50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.45V/cell Charge current : 0.3CA 3 Temperature : 25 (77 ) Charge current (CA) Charge volume Charge volume (%) Cell charge voltage ( V/Cell ) Charge current (CA) Charge volume (%) Cell charge voltage Charge volume 1 Discharge 100 % (0.1CA*10h) --50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.275V/cell Charge current : 0.1CA (77 ) 3 Temperature : 25 Charge current Charge current Charge Time (hr) Charge Time (hr) Shelf Life & Storage Cycle Life vs Depth of Discharge Open Circuit Voltage vs Residual Capacity Effect of Temperature on Capacity Charge Current & Final Discharge Voltage Application Charge Voltage(V/Cell) Set Point Allowable Range Cycle Use Temperature 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.30 2.27~2.30 Max.Charge Current Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 0.30C Discharge Current(A) 0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C Let UPG Power Your Life. www.upgi.com 1720 Hayden Drive Carrollton, Texas 75006 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]