Preview only show first 10 pages with watermark. For full document please download

Uberluft Flexible Communications Coax Cable - Automation-x

   EMBED


Share

Transcript

Uberluft Flexible Communications Coax Cable UBR-400-HPX Solid CCA Applications: PE – Foam Dielectric Multi-ply AL Tape Jumper assemblies in wireless communications systems Short antenna feeder runs Drop-in replacement for RG-8 air dielectric cable Perfect for any application requiring periodic/repeated flexing Tinned Copper Shield (90% Coverage) UV Resistant Black TPE Features: UBR-HPX has a solid center conductor and UV resistant black TPE jacket designed for 20 year service life. The flexible outer conductor inherent in UBR-SFX design promotes unparalleled flexibility and bendability. Superior RF shielding - multi-ply bonded foil outer conductor rated at >90 dB as opposed to 40 dB from single shielded coax. UBR-HPX exhibits extremely low signal loss, which is comparable to semirigid hard-line cables. UBR-HPX and cable assemblies are designed to resist even the harshest weather conditions for over ten years. Pre-Terminated Cable Assemblies are available in custom and standard lengths and sizes. A wide variety of connectors are also available. Electrical Specifications: Construction Specifications: Description Material Inches Metric Performance Property Units US % 86 Metric Inner Conductor Solid Copper Clad Aluminum 0.108 2.74 Velocity of Propagation Dielectric Foam Polyethylene 0.285 7.24 Dielectric Constant NA 1.38 Outer Conductor Multi-ply Aluminum Tape 0.291 7.39 Time Delay nS/ft (nS/m) 1.20 Overall Braid Tinned Copper (90% Coverage) 0.320 8.13 Impedance ohms 50 Jacket UV Resistant Thermoplastic Elastomer 0.405 10.29 Capacitance pF/ft (pF/m) 23.9 (78.4) Inductance uH/ft (uH/m) .060 (.20) Shielding Effectiveness dB >90 Inner Conductor ohms/1000ft(/km) 1.39 (4.6) Outer Conductor (5.4) Mechanical Specifications: Performance Property Units US Metric Bend Radius: Installation inches (mm) 1.00 (25.4) Bend Radius: Repeated inches (mm) 4.0 (101.6) DC Resistance ohms/1000ft(/km) 1.65 Volts DC 2500 Bending Moment ft/lb (N-m) 0.5 (0.68) Voltage Withstand Weight lb/ft (kg/m) 0.068 (0.10) Jacket Spark Volts RMS 8000 Tensile Strength lb (kg) 160 (72.6) Peak Power kW 16 Flat Plate Crush lb/in (kg/mm) 40 (0.71) Environmental Specifications: Performance Property ˚F ˚C Installation Temperature Range -40/+185 -40/+85 Storage Temperature Range -94/+185 -70/+85 Operating Temperature Range -40/+185 -40/+85 This publication summarizes product warranty and specifications which are subject to change without notice. uberluft.com (3.92) To Order: Automation-X is an authorized dealer of Uberluft products.