Preview only show first 10 pages with watermark. For full document please download

Ubgc2 Sealed Lead-acid Battery

   EMBED


Share

Transcript

UPG No. 45966 Sealed Lead-Acid Battery Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20567. UBGC2 Maintenance-Free Specification Nominal Voltage 6 volts 77º F (25º C) Nominal Capacity 20-hr. (10.0A) 200 Ah 10-hr. (18.6 A) 186 Ah 5-hr. (34 A) 170 Ah 1-hr. (120 A) 120 Ah Approximate Weight 62.4 lbs (28.3 kgs) Internal Resistance (approx.) 4 mŸ Shelf Life (% of normal capacity at 77º F (25º C)) 3 Months 6 Months 12 Months 91% 82% 64% (20 hour rate) Temperature Dependancy of Capacity 104º F 77º F 32º F 5º F 65% 102% 100% 85% AGM Operational Temperature Charge 32 F to 104 F (0 C to 40 C) Discharge 5 F to 113 F (-15 C to 45 C) AGM Storage Temperature 5 F to 104 F (-15 C to 40 C) Charge Method (Constant Voltage) Cycle Use (Repeating Use) Initial Current 60 A or smaller Control Voltage 7.20 - 7.5 V Float Use Control Voltage 6.8 - 6.9 V Physical Dimensions: in (mm) 9.72 (247) 10.67 (271) Terminals 7.09 (180) 10.24 (260) L: 10.24in (260 mm) W: 7.09in (180 mm) H: 9.72in (247 mm) TH: 10.67in (271 mm) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Discharge Characteristics Cell voltage (V/Cell) Discharge Time vs. Discharge Current (Minute) (Hour) Discharge time www.upgi.com 488 S. Royal Lane All specifications are subject to change Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected] A1326-1 UPG No. 45966 UBGC2 Maintenance-Free Battery Charging Characteristics for Cyclic Use Battery Charging Characteristics for Standby Use Cell charge voltage Cell charge voltage ( V/Cell ) 1 Discharge 100 % (0.1CA*10h) -- 50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.45V/cell Charge current : 0.3CA 3 Temperature : 25 (77 ) Charge current (CA) Charge volume Charge volume (%) Cell charge voltage ( V/Cell ) Charge current (CA) Charge volume (%) Cell charge voltage Charge volume 1 Discharge 100 % (0.1CA*10h) --50 % (0.1CA*5h) 2 Constant voltage charging Charge voltage : 2.275V/cell Charge current : 0.1CA (77 ) 3 Temperature : 25 Charge current Charge current Charge Time (hr) Charge Time (hr) Shelf Life & Storage Cycle Life vs Depth of Discharge Open Circuit Voltage vs Residual Capacity Effect of Temperature on Capacity Charge Current & Final Discharge Voltage Application Charge Voltage(V/Cell) Set Point Allowable Range Cycle Use Temperature 25 (77 ) 2.45 2.40~2.50 Standby 25 (77 ) 2.325 2.30~2.35 Max.Charge Current Final Discharge Voltage V/Cell 1.75 1.70 1.60 1.30 0.35C Discharge Current(A) 0.2C>(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C Let UPG Power Your Life. www.upgi.com 488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 [email protected]