Preview only show first 10 pages with watermark. For full document please download

Ucs1002 Datasheet Rev B

   EMBED


Share

Transcript

MODEL 1002 Universal Chassis System The EdgeAccess® Universal Chassis System (UCS) Model 1002 is a Carrier-class chassis designed to accommodate the Canoga Perkins 2U-sized products. The UCS 1002 is NEBS Level 3 tested and certified, ensuring a robust and fault-tolerant platform for multiple services. Multiple services can be offered in one chassis with end-to-end management of all modules. Each module inserted in the UCS 1002 is SNMP manageable, and can be managed via the Canoga Perkins graphical user interface (GUI), CanogaView®. Enterprise and Campus environments can benefit by the UCS 1002’s small footprint, manageability, density and low entry cost. The chassis design allows accommodation of up to 14 hot-swappable products. Single or redundant power supply settings are available. Eight UCS 1002 Chassis can be linked together to form a fully managed domain of up to 224 local and remote modules. FEATURES: • • • • • World Headquarters 20600 Prairie Street Chatsworth, CA 91311-6008 Phone (818) 718-6300 • Fax (818) 718-6312 E-mail: [email protected] • Fully Modular Carrier-class Chassis System Up to 14 Hot-swappable Modules in One Chassis Fault Tolerant and Redundant SNMP Management, CanogaView® Extensive Modularity and Compact Size for Reduced Cost Cost-effective Low Entry Price MODEL 1002 Universal Chassis System SPECIFICATIONS CHASSIS • DOMAIN MANAGEMENT MODULE • PHYSICAL Dimensions Weight - 3.5”H x 19.0”W x 10.5”D (88.9 x 482.6 x 266.7mm) 10 lbs (4.5kg) (with one AC Power Supply) • POWER • OPERATING ENVIRONMENT PHYSICAL Dimensions Weight • LEDs • SWITCHES STA - Green Amber Red ACT - Green LNK - Green Rx - Green AC Power Supply - 100W 90 to 264VAC @ 1.5A Max. 50/60Hz Input DC Power Entry Module - 100W -36 to -58VDC @ 3A Max. Input Temperature - 0˚ to 50˚C Humidity Up to 95% (Noncondensing) CHASSIS INTERCONNECT MODULE • PHYSICAL Dimensions Weight - • 3.0”H x 1.0”W x 9.0”D (76.2 x 25.4 x 228.6mm) 0.3 lb (0.1kg) LEDs STA MAJ MIN CLK - Green Amber Red Red Amber Green Red • SWITCH • CONNECTORS • CHASSIS LINK = = = = = = = Normal Alarm Relay Latched Nonoperational Major Alarm Detected Minor Alarm Detected Active Clock Source Clock Source Failed 3.0”H x 1.0”W x 9.0”D (76.2 x 25.4 x 228.6mm) 0.3 lb (0.1kg) = = = = = = Normal Blinking Boot-up Self-test Nonoperational Management Activity Ethernet 10BASE-T Link-up Ethernet 10BASE-T Receive Activity EIA-232 10BASE-T - MDM/TRM MDI/MDX Reset - Management Module • CONNECTORS • REGULATORY COMPLIANCE EIA-232 10BASE-T ETL, ETLc (UL 60950 CAN/CSA C.22 No. 60950, EN/IEC 60950) IEC 60825-1 FCC Part 15B/IC-003/VCCI Class A C-Tick (AS/NZS 3548), EN 55022 Class A EN 61000-3-2, EN 61000-3-3 EN 55024 R&TTE Directive (EN 300 386) NEBS Level 3 Tested and Certified Reset Alarm Relay Major Alarm Relay Normally Open/Closed Minor Alarm Relay Normally Open/Closed Proprietary 8-pin• World Headquarters 20600 Prairie Street Chatsworth, CA 91311-6008 Phone (818) 718-6300 • Fax (818) 718-6312 E-mail: [email protected] ISO 9001 Registered 66052500 Rev B www.canoga.com Specifications are subject to change without notice. The trademarks, service marks, and logos (”Marks”) displayed herein are the property of Canoga Perkins Corporation or other third parties.These Marks may not be used without the prior written consent of Canoga Perkins Corporation or a third party, which may own the Mark. Copyright© Canoga Perkins Corporation 2005. All rights reserved.