Preview only show first 10 pages with watermark. For full document please download

Udskriv Datablad

   EMBED


Share

Transcript

6FM100D-X 12V 95.5Ah(10hr) The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid General Features ● ● ● ● ● ● ● ● Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge. Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 330 / 12.99 171 / 6.73 215 / 8.46 220 / 8.66 32 / 70.5 Performance Characteristics Nominal Voltage Number of cell Design Life Nominal Capacity 77oF(25oC) 12V 6 10 years 10 hour rate (9.55A, 10.8V) 95.5Ah 5 hour rate (17.4A, 10.5V) 87.0Ah 1 hour rate (65.2A, 9.6V) 65.2Ah Internal Resistance 5mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 900A(5s) Max. Discharge Current 77 F(25 C) Short Circuit Current 2100A Charge Methods: Constant Voltage Charge Cycle use Maximum charging current Temperature compensation Standby use Temperature compensation 77oF(25oC) 14.4-14.7V 30A -30mV/oC 13.6-13.8V -20mV/oC Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V 5min 10min 15min 30min 45min 1h 3h 5h 10h 298 281 257 230 210 220 212 192 180 168 180 173 159 148 139 105 101 93.6 90.7 88.7 78.9 77.1 71.5 69.9 68.6 65.2 61.6 60.6 59.6 56.5 27.6 27.4 26.9 26.6 25.1 18.9 18.2 17.9 17.4 17.1 9. 75 9. 70 9. 65 9. 60 9. 55 Discharge Constant Power (Watts at 77oF25oC) End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V 5min 10min 15min 30min 45min 1h 2h 3h 5h 520 491 454 419 394 376 364 346 339 316 311 306 290 285 271 194 183 178 173 167 147 143 134 131 128 122 116 112 109 102 69.7 66.9 65.9 63.7 61.7 52.3 50.7 50.4 48.6 48.0 35.6 35.2 34.8 34.2 33.8 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. page1 of 2 www.vision-batt.com Current Charged Volume O Discharge characteristic (25 C) Voltage 6FM100D-X 12V95.5Ah Charge characteristic curve Constant voltage charge characteristic (0.25CA,25 oC) (%) (XCA) (V) Battery voltage(V) 12.0 140 26.6A17.4A 9.6 9.55A 120 0.25 100 0.20 80 90A 65.2A 185A 0.15 1 2 3 5 10 min 20 30 60 2 3 5 10 20 0.10 20 0.05 0 0 h CHARGED VOLUME 14.0 CHARGE VOLTAGE 13.0 60 40 0 15.0 12.0 11.0 0 Discharge time (V/8V) (V/6V) (V/4V) (V/CELL) 7.8 5.2 2.6 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 13.2 8.8 6.6 4.4 2.2 CY CL 10 12 14 16 18 20 ND B EU SE Y US 12 14 16 18 Storage time: months 20 90 80 70 60 E 40 oC 30 o C 20 o C 50 0 10 20 30 40 50 Ambient temperature( oC) 40 60 0 2 4 6 8 10 Cycle service life in relation to depth of discharge Life characteristics of standby use 120 120 100 100 Capacity(%) Capacity(%) 8 110 -10 80 60 Testing conditions: floating voltage: 2.27 to 2.30V/Cell o o ambient temperature: 25 C(77 F) 80 60 40 40 20 20 0 4 6 Life(year) 100% D.O.D. 0 8 200 30% Depth of discharge 50% D.O.D. 400 600 800 1000 1200 1400 1600 Number of cycles(cycles) Temperature effects on float life Temperature effects on capacity 120 15 100 2.30V/Cell 10 Capacity (%) Life(years) 6 100 S TA 0 4 Self-discharge characteristic Capacity(%) (V/12V) 10.4 15.0 2 Charging time (hours) Relationship between charging voltage and temperature 15.6 CHARGING CURRENT 5 C 0 .0 5 0 .1 C 0 .2 C 80 60 1.0C 2.0C 40 20 0 10 20 30 40 0 50 -20 -10 o Temperature( C) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2000 MH25860 0 10 20 Temperature( oC) 30 40 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9) Page 2 of 2 50