Ultra-aire 70h Engineering Spec Data Sheet

   EMBED


Share

Transcript

Ultra-Aire™ 70H Ventilating Dehumidifier Specification Data Capacities and Performance Part Number: 4033730 Blower: 150 CFM @ 0.0” WG 140 CFM @ 0.2” WG 130 CFM @ 0.4” WG Power: 580 Watts @ 80°F and 60% RH Supply Voltage: 115 VAC – 1phase – 60 Hz Current Draw: 5.1 Amps Energy Factor: 2.4 L/kWh Operating Range: 49°F - 95°F Max (Inlet Air Temperature) BACK 34°F - 135°F Max (Outside Cabinet) 12” Sized for: Up to 1,800 Sq. Ft. - Typical 4033730 22” 12” 8” 3/4” Threaded Female NPT Drain Connection: Refrigerant Type: R410A (Refer to manufacturers label for more information) Refrigerant Amount: 15 oz. Dimensions: Width: Height: Length: Weight: 8” 12” 12” 8” 12” 12” Length: 28" 22" 9’, 31115 5/8"VAC, Ground Power Cord: Weight: 55 lbs. 54 lbs. 65 lbs. Internal Insulated Cabinet: Yes BACK 12” WITH COLLARS Unit With Collars Unit Without Collars Width: 12” 12” Height: 12” 12” Length: 28” 22” Weight: 55 lbs. 54 lbs. Shipping 12" 15 5/8” 12" 16” 28" 31 5/8” 55 lbs. 65 lbs. DEH 3000 Control P/N 4028539 With Remote: P/N 4028407 • Digital Control of Relative Humidity • Fan/Filter Operation • Programmable Ventilation Timer • Large, easy-to-read backlit LCD display • Easy interaction with air handler fan • High Temperature Cut-Out • Dryout Cycle Timer • Auto Reboot • Remote Sensor (DEH 3000R Only) Optional Accessories W/ OUT COLLARS 12" 12" 22" 54 lbs. 4028539 15 5/8" 4028407 16" 4030671 31 5/8" 4030734 65 lbs. 4030733 4030113 4036695 4025287 4024370 4029087 4023672 4026859 4020128 4020656 4023647 4020646 4027415 4020177 DEH 3000 Control DEH 3000R Control (with Remote) MERV 11 Filter (9"x11"x1") MERV 11 Filters 4-Pack MERV 11 Filters 12-Pack Pump Kit Hang Kit MERV 14 Filter Housing MERV 14 Filter (20"x24"x4") MERV 14 Filter 3-Pack 6" Motorized Damper 6" Flex Duct 25' 6" Flex Insulated Duct 25' 6" Inlet/Exhaust Hood 8"Gravity Damper 8" Butterfly Damper 8" Flex Duct 25' 8" Flex Insulated Duct 25' 1-800-533-7533 | www.Ultra-AireContractor.com 12” 12” Optional Air Filter: MERV-14, Embossed Pleat W/ OUT COLLARS WITH COLLARS (will need filter housing) Efficiency: ASHRAE Dust Spot Width: 12" 12" 95% 15 5/8" 8” Size: Height: 12" 12" 20” 16"x 24” x 4” FRONT 12” 8” MERV-11, Mini Pleat 65% ASHRAE Dust Spot 9” x 11” x 1” 28” 8” 8” Round Inlet; 8” Round Outlet Air Filter: Efficiency: Size: BACK 12” Duct Connections: 12” 8” 70°F and 60% RH 47 pints/day 8” 4.0 Pints/kWh 12” Minimum Performance at: 80°F and 60% RH Water Removal: 70 pints/day Efficiency: 5.0 Pints/kWh 28” 22” Ultra-Aire™ 70H Ventilating Dedicated Ultra-Aire 70 Dehumidifier Return to A/C Supply Recommended Installations Dedicated Return to HVAC Supply • Create a separate return for the Ultra-Aire 70H in a central area of the building. • Duct the supply of the Ultra-Aire 70H to the air supply of the HVAC system with a back draft damper. Whole House and Basement/Crawlspace Dedicated Return to HVAC Supply Air Handler HVAC Supply HVAC Return Fresh Air Intake (Optional) Motorized Damper Indoor Air Return Basement / Crawlspace Intall Ultra-Aire Supply Indoor Air Return Air Handler Supply • Duct the supply of the Ultra-Aire 70H to a 8” x 8”x 8” tee damper that is 20 percent open to the basement/crawlspace. • Duct the other side of the tee to the air supply of the existing HVAC system with a backdraft damper. Back Draft Damper Back Draft Damper Dry Air to Basement Gravity Damper A/C Return to A/C Supply Fresh Air Intake (Optional) Motorized Damper Ultra-Aire Supply Alternative Installations HVAC Return to HVAC Supply • Check Damper should be in place between the Return and Supply connections of the dehumidifier. • If Check Damper is not in place, the A/C fan must turn on when the dehumidifier is in operation. Optional Check Damper HVAC Return (no A/C fan needed) Air Handler HVAC Supply Dedicated Ultra-Aire 70 Return to A/C Return Fresh Air Intake (Optional) Back Draft Damper Motorized Damper Dedicated Return to HVAC Return • Create a separate return for the Ultra-Aire 70H in a central area of the building. • Installing the supply air from the Ultra-Aire 70H in the return of the HVAC system requires the HVAC fan to run when the Ultra-Aire 70H is operating. HVAC Return to HVAC Return • Check Damper should be in place between the Return and Supply connections of the dehumidifier. Ultra-Aire Supply Air Handler Fresh Air Intake (Optional) Motorized Damper Indoor Air A/C Return HVAC Return HVAC Supply Return to A/C Return Ultra-Aire Supply Optional Check Damper (no A/C fan needed) Air Handler HVAC Supply HVAC Return • If Check Damper is not in place, the A/C fan must Optional Fresh Air Intake turn on when the dehumidifier is in operation. Motorized Damper Indoor Air Return Fresh Air Intake (Optional) Motorized Damper Ultra-Aire Supply 1-800-533-7533 | www.Ultra-AireContractor.com Rev 3/24/16