UNICO.A.STD/ELN “G” Air cooled liquid chillers with Scroll compressors and axial fans
SCROLL compressors 20 ÷ 115 kW
RC GROUP TECHNICAL DOCUMENTATION UNCSRL_AG_GB407_0203
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans WORKING LIMITS COOLING MODE Evaporator water temperature: +6°C Leaving water minimum temperature. -6°C Leaving water minimum temperature by adding antifreeze. -15°C Leaving water minimum temperature by adding antifreeze and BRINE kit. +20°C Inlet water maximum temperature. Outdoor air temperature: -5°C minimum value. -15°C minimum value with condensing control system. +41°C maximum value for unit in full load conditions. +47°C maximum value for unit in partial load conditions. HEAT RECOVERY SYSTEMS: + 30÷48°C Outlet water temperature range value.
WARNING All limit and working values showed in the catalogue are referred to nominal conditions with water to the evaporator 12/7°C and R407C refrigerant charge. For different working conditions and/or other refrigerants, please check the limit operating conditions of the specific model with the electronic selection program RCWORLD. All the products manufactured by the RC GROUP, in its manufacturing divisions, RC CONDIZIONATORI, AMP and SIMAIR, are designed and produced with materials and components suitable to be exposed to temperatures of -40÷45°C without any damage to the material structure nor to the components and machines operational characteristics. In case it will be required that the RC GROUP products, for outdoor installations, will grant working continuity with outside temperatures lower than -15°C, a low ambient temperature kit, with features different for each product, is available upon request. RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-2-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23 norms and subsequent modifications. UNICO.A.STD: Chiller in standard version. COMPONENTS • Unit base made of epoxy painted galvanized steel sheet profiles and sandwich panel injected with noise and vibration deading material. • Housing made of anodized aluminium profile frame, jointed with reinforced PVC corners and galvanized steel sheet panelling externally coated with PVC film. • Technical compartment, fully enclosed and separate from the air flow, housing compressors, control, electric and regulation devices, to assure working continuity during ordinary service and preventive maintenance operations and to reduce the noise emissions. • Stainless steel AISI 316 welded plate evaporator, with one gas circuit for each compressor, insulated with closed cells polyurethane. • Evaporator antifreeze heater. • Direct driven axial fans protected by special safety mesh. • Condensing coil with copper tubes, continuous aluminium finning with aluminium or epoxy painted galvanized steel sheet frame. • SCROLL type hermetic compressor with built-in integral electric protection, built-in silencer on gas discharge and crankcase electric heater. • Stop valves on compressor suction and discharge. • Rubber holders for compressor. • Step-step condensing control system, acting on condenser fans, allowing the following operating conditions: - Full load with outdoor temperature from -5 to +43/46°C. - Partial load (if scheduled) with outdoor temperature up to +48/52°C. Over this limit a safety device stop the unit. • Components for each refrigerant circuit: - Thermostatic expansion valve. - Liquid and moisture indicator. - Electromagnetic valve on the liquid line. - Dryer and anti-acid gas filter. - Stop valves on the liquid line and on the evaporator. - Copper connecting pipings for liquid circuit line. - Copper suction line. - Flexible discharge line. - Flexible pipings for pressure switches connection. - High pressure safety switches. - Pressure transducers, for monitoring, control and limit functions for high and low pressure. - Pump-down stop system. - Refrigerant charge and non-freezing oil charge. • MP99 microprocessor control system. • Temperature sensors on evaporator water inlet and outlet. • Differential pressure switch on evaporator water side with protective function. • Phases monitoring relay. • IP 54 electric board equipped with: - Quick opening external panel with protective function. Safety internal panel equipped with door lock main switch, microprocessor display and auxiliary controls. - Contactors on each single load. - Magnetothermic switches on each single load (for load with nominal absorption higher than 44A, fuses are installed). - Auxiliary circuit and microprocessor feeding by transformer.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-3-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans UNICO.A.STD: Chiller in standard version. OPTIONAL • LNO kit: - Panels and technical compartment insulated by means of special sound deadening materials. - Condensing control system by stepless condenser fans speed, through electronic regulators directly driven by the proportional signal managed by MP99 microprocessor control, allowing the following operating conditions: ◊ Full load with outdoor temperature from -15 to +34/38°C. ◊ Full load with fans at max speed and noise pressure increased up to the STD units with outdoor temperature up to +43/46°C. ◊ Partial load (if scheduled) with outdoor temperature up to +48/52°C. Over this limit a safety device stop the unit. • Noise absorption plenum on fans air discharge, height 750mm. • Spring antivibration holders (not installed). • Washable metallic air filters with low pressure drops to prevent condensing coil clogging. • Modular metallic nets for condensing coil protection. • Condensing coil with marine alloy fins. • Condensing coil with epoxy coated fins. • Condensing coil with copper fins. • Condensing coil with tin coated copper fins. • Partial heat recovery gas/water heat exchanger. • Total heat recovery gas/water heat exchanger. • Condensing control system with continuous variation of the condenser fans speed through electronic regulators directly driven by the proportional signal managed by MP99 microprocessor control. • UDT, SQL o ASME VIII Div. 1 approved pressure vessels. • Compressor capacitor for power factor cosϕ 0,9. • Safety flow switch on the water circuit. • Pumping groups equipped with 1 or 2 (working+stand-by) water pumps: - PU pumping group with 2 poles water pumps. • Chilled water tank with antifreeze electric heater, unit size G0 excluded. • TR88 system for the management and the local supervision. Through RS485 serial line, every TR88 can manage max. 8 units. More TR88 can be utilized to adequate the control system to the plant units quantity. • MP99 microprocessor accessories: - TV system - Phase-lack control and line voltage displaying. - TA system - Total electric absorption indication. - RC3500 card - RS232C-RS422-RS485 serial line outlet. - RCBUS card - Serial line interface for MODBUS and JBUS communication protocols. - RC3100 "D" "N" cards - Alarms remotization. - Outdoor air temperature sensor.
WARNING RC GROUP reserves the right to accept the matching of the optional installed on the unit.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-4-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans TECHNICAL DATA UNICO.A.STD: Chiller in standard version. MODEL SIZE COOLING CAPACITY (1) kW COMPRESSORS (1) n. Power input kW Absorbed current A Max absorbed current A Starting current A FANS n. Air flow m3/h Power input kW Max absorbed current A EVAPORATOR (1) n. Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h GAS CIRCUITS n. CAPACITY STEPS n. DESUPERHEATER (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h 100% HEAT RECLAIM (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h PUMPING GROUP 1 pump group PU 1 pump group PU-LN 2 pumps group PU 2 pumps group PU-LN DIMENSIONS Lenght mm Width mm Height mm NET WEIGHT kg ENERGY EFFICIENCY INDEX (3) Nominal efficiency EER Standard capacity steps IPLV Standard capacity steps EMPE
21.Z.1 G0 20,3 1 7,2 13,5 17 130 1 9000 0,78 3,5 1 3,5 27,8 2 7,2 1 1
25.Z.1 G0 23,2 1 8,5 15,8 20 130 1 10500 0,78 3,5 1 4 36,2 2 7,2 1 1
32.Z.1 G2 32,5 1 10 17,7 24 135 2 18000 1,56 3,5 1 5,6 31,4 2 10,7 1 1
37.Z.1 G2 36,7 1 12,4 22,4 29 175 2 16500 1,56 3,5 1 6,3 16,5 4 15 1 1
50.Z.1 G2 49,3 1 16,9 29,1 38 215 2 20000 1,56 3,5 1 8,5 19,6 4 19 1 1
61.Z.1 G4 56,5 1 23,1 38,3 46 270 2 18000 1,56 3,5 1 9,7 18,1 5 23 1 1
6,3 1,1 4,7
7,2 1,3 6,1
10,1 1,8 12
11,4 2 5,5
15,4 2,7 9,9
17,6 3,1 13
3
3
3
8
8
8
27,9 4,9 31,4
32,1 5,6 41,6
42,2 7,4 48,8
49,1 8,6 22,7
66,6 11,6 24
81,9 14,3 25,7
20
20
20
16
16
28
1/1 ----
1/1 ----
1/1 ----
1/1 ----
2/1 ----
2/1 ----
1150 895 1640 330
1150 895 1640 330
2000 1040 1690 480
2000 1040 1690 540
2000 1040 1690 590
2600 1200 1690 750
2,82 4,14 3,19
2,73 4,01 3,08
3,25 4,78 3,67
2,96 4,35 3,34
2,92 4,29 3,30
2,45 3,60 2,76
1 Outdoor temperature: 35°C; Chilled water temperature outlet 7°C 2 Hot water temperature inlet 40°C. 3 IPLV: Energy efficiency index according to ARI STANDARD EMPE: Energy efficiency index according to AICARR For more informations about Energy Efficiency Indexes. please refer to “Energy Efficiency Indexes” bulletin of RC GROUP Technical Literature. SUPPLY VOLTAGE 400/3/50 + Mp On request 230/3/50 - 415/3/50. RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-5-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans TECHNICAL DATA UNICO.A.STD: Chiller in standard version. MODEL SIZE COOLING CAPACITY (1) kW COMPRESSORS (1) n. Power input kW Absorbed current A Max absorbed current A Starting current A FANS n. Air flow m3/h Power input kW Max absorbed current A EVAPORATOR (1) n. Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h GAS CIRCUITS n. CAPACITY STEPS n. DESUPERHEATER (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h 100% HEAT RECLAIM (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h PUMPING GROUP 1 pump group PU 1 pump group PU-LN 2 pumps group PU 2 pumps group PU-LN DIMENSIONS Lenght mm Width mm Height mm NET WEIGHT kg ENERGY EFFICIENCY INDEX (3) Nominal efficiency EER Standard capacity steps IPLV Standard capacity steps EMPE
36.Z.2 G2 34,6 2 11,3 21,3 28 111 2 18000 1,56 3,5 1 5,9 38 2 10,3 2 2
42.Z.2 G2 40,3 2 14,4 26,9 34 145 2 18000 1,56 3,5 1 6,9 36,3 3 12 2 2
50.Z.2 G2 45,5 2 17,1 31,8 39 148 2 16500 1,56 3,5 1 7,8 46,2 3 12 2 2
64.Z.2 G4 60,4 2 21,5 37,6 48 157 3 27000 2,34 3,5 1 10,4 51,5 4 14,4 2 2
74.Z.2 G4 69 2 25,3 45,6 58 201 3 27000 2,34 3,5 1 11,8 47,7 4 15,8 2 2
87.Z.2 G6 87,5 2 27,9 49,7 67 241 4 41000 4,4 8 1 15 22,8 10 31,3 2 2
100.Z.2 G6 97,9 2 33,6 57,8 76 249 4 41000 4,4 8 1 16,8 28,5 10 31,3 2 2
124.Z.2 G6 114,9 2 44 73,6 92 311 4 41000 4,4 8 1 19,7 32,5 12 34,4 2 2
10,8 1,9 4,5
12,6 2,2 4,6
14,2 2,5 5,9
18,9 3,3 3,7
21,5 3,8 4,9
27,3 4,8 7,8
30,5 5,3 9,8
35,8 6,2 13,4
6
6
6
16
16
16
16
16
46 8 21,3
55,4 9,6 30,9
63,5 11,1 40,6
82,6 14,4 46,6
95,1 16,6 12,3
115,3 20,1 18
131,8 23 23,6
161,6 28,1 25
40
40
40
40
32
32
32
56
1/1 -1/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
3/1 -3/2 --
2000 1040 1690 570
2000 1040 1690 590
2000 1040 1690 610
2600 1200 1690 820
2600 1200 1690 860
3600 1290 1690 1180
3600 1290 1690 1240
3600 1290 1690 1240
3,06 4,50 3,46
2,80 4,11 3,16
2,66 3,91 3,01
2,81 4,13 3,17
2,73 4,01 3,08
3,14 4,61 3,54
2,91 4,28 3,29
2,61 3,84 2,95
1 Outdoor temperature: 35°C; Chilled water temperature outlet 7°C 2 Hot water temperature inlet 40°C. 3 IPLV: Energy efficiency index according to ARI STANDARD EMPE: Energy efficiency index according to AICARR For more informations about Energy Efficiency Indexes. please refer to “Energy Efficiency Indexes” bulletin of RC GROUP Technical Literature. SUPPLY VOLTAGE 400/3/50 + Mp On request 230/3/50 - 415/3/50. RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-6-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans ACOUSTIC DATA UNICO.A.STD: Chiller in standard version. SOUND PRESSURE LEVEL (LP) Sound pressure level in free field conditions on condenser coil side. MODEL Sound pressure level 1m far 5m far 10m far MODEL Sound pressure level 1m far 5m far 10m far
dB(A) dB(A) dB(A)
dB(A) dB(A) dB(A)
21.Z.1
25.Z.1
32.Z.1
37.Z.1
50.Z.1
61.Z.1
68 54 48
68 54 48
68 54,8 48,8
70 56,8 50,8
70 56,8 50,8
70 56,8 50,8
36.Z.2
42.Z.2
50.Z.2
64.Z.2
74.Z.2
87.Z.2
100.Z.2
124.Z.2
70 56,8 50,8
70 56,8 50,8
70 56,8 50,8
70 57,5 51,6
71 58,5 52,6
71 60,5 54,6
71 60,5 54,6
72 61,5 55,6
MEAN SOUND PRESSURE LEVEL (LPm) Mean sound pressure level in free field conditions, according to ISO 3744 norm. MODEL Mean sound pressure level 1m far dB(A)
21.Z.1
25.Z.1
32.Z.1
37.Z.1
50.Z.1
61.Z.1
62
62
62
64
64
64
MODEL Mean sound pressure level 1m far dB(A)
36.Z.2
42.Z.2
50.Z.2
64.Z.2
74.Z.2
87.Z.2
100.Z.2
124.Z.2
64
64
64
64
65
65
65
66
UNICO.A.LNO: Chiller in standard version with LNO kit. SOUND PRESSURE LEVEL (LP) Sound pressure level in free field conditions on condenser coil side. MODEL Sound pressure level 1m far 5m far 10m far MODEL Sound pressure level 1m far 5m far 10m far
dB(A) dB(A) dB(A)
dB(A) dB(A) dB(A)
21.Z.1
25.Z.1
32.Z.1
37.Z.1
50.Z.1
61.Z.1
61,8 47,8 41,8
61,8 47,8 41,8
61,8 48,6 42,6
63,8 50,6 44,6
63,8 50,6 44,6
63,8 50,6 44,6
36.Z.2
42.Z.2
50.Z.2
64.Z.2
74.Z.2
87.Z.2
100.Z.2
124.Z.2
63,8 50,6 44,6
63,8 50,6 44,6
63,8 50,6 44,6
63,8 51,3 45,4
64,8 52,3 46,4
64,8 54,3 48,4
64,8 54,3 48,4
65,8 55,3 49,4
MEAN SOUND PRESSURE LEVEL (LPm) Mean sound pressure level in free field conditions, according to ISO 3744 norm. MODEL Mean sound pressure level 1m far dB(A)
21.Z.1
25.Z.1
32.Z.1
37.Z.1
50.Z.1
61.Z.1
55,8
55,8
55,8
57,8
57,8
57,8
MODEL Mean sound pressure level 1m far dB(A)
36.Z.2
42.Z.2
50.Z.2
64.Z.2
74.Z.2
87.Z.2
100.Z.2
124.Z.2
57,8
57,8
57,8
57,8
58,8
58,8
58,8
59,8
IMPORTANT For further information about units acoustic data, please refer to “The Noise” bulletin of RC GROUP Technical Literature. RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-7-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23 norms and subsequent modifications. UNICO.A.ELN: Chiller in extremely low noise version. COMPONENTS • Unit base made of epoxy painted galvanized steel sheet profiles and sandwich panel injected with noise and vibration deading material. • Housing made of anodized aluminium profile frame, jointed with reinforced PVC corners and galvanized steel sheet panelling externally coated with PVC film. • Technical compartment, fully enclosed and separate from the air flow, housing compressors, control, electric and regulation devices, to assure working continuity during ordinary service and preventive maintenance operations and to reduce the noise emissions. • Panels and technical compartment insulated by means of special sound deadening materials. • Stainless steel AISI 316 welded plate evaporator, with one gas circuit for each compressor, insulated with closed cells polyurethane. • Evaporator antifreeze heater. • Direct driven low speed axial fans protected by safety mesh. • Condensing coil with wide exchange surface with copper tubes, continuous aluminium finning with aluminium or epoxy painted galvanized steel sheet frame. • SCROLL type hermetic compressor with built-in integral electric protection, built-in silencer on gas discharge and crankcase electric heater. • Stop valves on compressor suction and discharge. • Rubber holders for compressor. • Condensing control system by stepless condenser fans speed, through electronic regulators directly driven by the proportional signal managed by MP99 microprocessor control, allowing the following operating conditions: - Full load with outdoor temperature from -15 to +37/40°C. - Full load with fans at max speed and noise pressure increased of about 5÷6 dB(A) with outdoor temperature up to +43/46°C. - Partial load (if scheduled) with outdoor temperature up to +48/52°C. Over this limit a safety device stop the unit. • Components for each refrigerant circuit: - Thermostatic expansion valve. - Liquid and moisture indicator. - Electromagnetic valve on the liquid line. - Dryer and anti-acid gas filter. - Stop valves on the liquid line and on the evaporator. - Copper connecting pipings for liquid circuit line. - Copper suction line. - Flexible discharge line. - Flexible pipings for pressure switches connection. - High pressure safety switches. - Pressure transducers, for monitoring, control and limit functions for high and low pressure. - Pump-down stop system. - Refrigerant charge and non-freezing oil charge. • MP99 microprocessor control system. • Temperature sensors on evaporator water inlet and outlet. • Differential pressure switch on evaporator water side with protective function. • Phases monitoring relay. • IP 54 electric board equipped with: - Quick opening external panel with protective function. Safety internal panel equipped with door lock main switch, microprocessor display and auxiliary controls. - Contactors on each single load. - Magnetothermic switches on each single load (for load with nominal absorption higher than 44A, fuses are installed). - Auxiliary circuit and microprocessor feeding by transformer.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-8-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans UNICO.A.ELN: Chiller in extremely low noise version. OPTIONALS • Noise absorption plenum on fans air discharge, height 750mm. • Spring antivibration holders (not installed). • Washable metallic air filters with low pressure drops to prevent condensing coil clogging. • Modular metallic nets for condensing coil protection. • Condensing coil with marine alloy fins. • Condensing coil with epoxy coated fins. • Condensing coil with copper fins. • Condensing coil with tin coated copper fins. • Partial heat recovery gas/water heat exchanger. • Total heat recovery gas/water heat exchanger. • UDT, SQL o ASME VIII Div. 1 approved pressure vessels. • Compressor capacitor for power factor cosϕ 0,9. • Safety flow switch on the water circuit. • Pumping groups equipped with 1 or 2 (working+stand-by) water pumps: - PU pumping group with 2 poles water pumps. • Chilled water tank with antifreeze electric heater, unit size G0 excluded. • TR88 system for the management and the local supervision. Through RS485 serial line, every TR88 can manage max. 8 units. More TR88 can be utilized to adequate the control system to the plant units quantity. • MP99 microprocessor accessories: - TV system - Phase-lack control and line voltage displaying. - TA system - Total electric absorption indication. - RC3500 card - RS232C-RS422-RS485 serial line outlet. - RCBUS card - Serial line interface for MODBUS and JBUS communication protocols. - RC3100 "D" "N" cards - Alarms remotization. - Outdoor air temperature sensor.
WARNING RC GROUP reserves the right to accept the matching of the optional installed on the unit.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
-9-
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans TECHNICAL DATA UNICO.A.ELN: Chiller in extremely low noise version. MODEL SIZE COOLING CAPACITY (1) kW COMPRESSORS (1) n. Power input kW Absorbed current A Max absorbed current A Starting current A FANS n. Air flow m3/h Power input kW Max absorbed current A EVAPORATOR (1) n. Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h GAS CIRCUITS n. CAPACITY STEPS n. DESUPERHEATER (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h 100% HEAT RECLAIM (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h PUMPING GROUP 1 pump group PU 1 pump group PU-LN 2 pumps group PU 2 pumps group PU-LN DIMENSIONS Lenght mm Width mm Height mm NET WEIGHT kg ENERGY EFFICIENCY INDEX (3) Nominal efficiency EER Standard capacity steps IPLV Standard capacity steps EMPE
21.Z.1 G2 19,1 1 8 14,4 17 130 1 5500 0,78 3,5 1 3,3 24,4 2 7,2 1 1
25.Z.1 G2 22 1 9,2 16,7 20 130 1 6500 0,78 3,5 1 3,8 32,5 2 7,2 1 1
32.Z.1 G2 29,2 1 11,8 20,2 24 135 2 9000 1,56 3,5 1 5 25,3 2 10,7 1 1
37.Z.1 G4 34,7 1 13,4 23,8 29 175 2 11000 1,56 3,5 1 6 14,8 4 15 1 1
50.Z.1 G4 45,8 1 18,8 31,6 38 215 3 14000 2,34 3,5 1 7,9 16,9 4 19 1 1
61.Z.1 G4 55,4 1 23,7 38,8 46 270 3 15000 2,34 3,5 1 9,5 17,4 5 23 1 1
6 1 4,2
6,9 1,2 5,5
9,1 1,6 9,7
10,8 1,9 4,9
14,3 2,5 8,6
17,3 3 12,5
3
3
3
8
8
8
27,9 4,9 31,4
32,1 5,6 41,6
42,2 7,4 48,8
49,1 8,6 22,7
66,6 11,6 24
81,9 14,3 25,7
20
20
20
16
16
28
1/1 ----
1/1 ----
1/1 ----
1/1 ----
2/1 ----
2/1 ----
2000 1040 1690 460
2000 1040 1690 460
2000 1040 1690 500
2600 1200 1690 680
2600 1200 1690 770
2600 1200 1690 790
2,39 3,51 2,70
2,39 3,52 2,70
2,47 3,64 2,80
2,59 3,81 2,93
2,44 3,58 2,75
2,34 3,44 2,64
1 Outdoor temperature: 35°C; Chilled water temperature outlet 7°C 2 Hot water temperature inlet 40°C. 3 IPLV: Energy efficiency index according to ARI STANDARD EMPE: Energy efficiency index according to AICARR For more informations about Energy Efficiency Indexes. please refer to “Energy Efficiency Indexes” bulletin of RC GROUP Technical Literature. SUPPLY VOLTAGE 400/3/50 + Mp On request 230/3/50 - 415/3/50. RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 10 -
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans TECHNICAL DATA UNICO.A.ELN: Chiller in extremely low noise version. MODEL SIZE COOLING CAPACITY (1) kW COMPRESSORS (1) n. Power input kW Absorbed current A Max absorbed current A Starting current A FANS n. Air flow m3/h Power input kW Max absorbed current A EVAPORATOR (1) n. Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h GAS CIRCUITS n. CAPACITY STEPS n. DESUPERHEATER (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h 100% HEAT RECLAIM (2) Heating capacity kW Water flow m3/h Pressure drops kPa Water content l Max water flow m3/h PUMPING GROUP 1 pump group PU 1 pump group PU-LN 2 pumps group PU 2 pumps group PU-LN DIMENSIONS Lenght mm Width mm Height mm NET WEIGHT kg ENERGY EFFICIENCY INDEX (3) Nominal efficiency EER Standard capacity steps IPLV Standard capacity steps EMPE
36.Z.2 G4 32,6 2 12,3 22,6 28 111 2 11000 1,56 3,5 1 5,6 33,9 2 10,3 2 2
42.Z.2 G4 38,2 2 15,6 28,5 34 145 3 12000 2,34 3,5 1 6,6 32,6 3 12 2 2
50.Z.2 G4 44,4 2 17,8 32,6 39 148 3 15000 2,34 3,5 1 7,6 44,1 3 12 2 2
64.Z.2 G4 54,9 2 24,6 41,7 48 157 3 15000 2,34 3,5 1 9,4 42,5 4 14,4 2 2
74.Z.2 G6 63,3 2 28,6 50,1 58 201 4 17500 3,12 7 1 10,9 40,1 4 15,8 2 2
87.Z.2 G7 80,8 2 31,8 54,8 67 241 4 26000 3,12 7 1 13,9 19,4 10 31,3 2 2
100.Z.2 G7 88,8 2 38,4 64,2 76 249 4 26000 3,12 7 1 15,2 23,4 10 31,3 2 2
124.Z.2 G7 110,1 2 46,6 76,8 92 311 4 31000 4,4 8 1 18,9 29,9 12 34,4 2 2
10,2 1,8 4
11,9 2,1 4,2
13,9 2,4 5,6
17,1 3 3,1
19,7 3,4 4,1
25,2 4,4 6,7
27,7 4,8 8,1
34,4 6 12,3
6
6
6
16
16
16
16
16
46 8 21,3
55,4 9,6 30,9
63,5 11,1 40,6
82,6 14,4 46,6
95,1 16,6 12,3
115,3 20,1 18
131,8 23 23,6
161,6 28,1 25
40
40
40
40
32
32
32
56
1/1 -1/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
2/1 -2/2 --
3/1 -3/2 --
2600 1200 1690 720
2600 1200 1690 750
2600 1200 1690 750
2600 1200 1690 820
3600 1290 1690 1120
3600 1290 2215 1230
3600 1290 2215 1290
3600 1290 2215 1340
2,65 3,90 2,99
2,45 3,60 2,77
2,49 3,67 2,82
2,23 3,28 2,52
2,21 3,25 2,50
2,54 3,74 2,87
2,31 3,40 2,61
2,36 3,47 2,67
1 Outdoor temperature: 35°C; Chilled water temperature outlet 7°C 2 Hot water temperature inlet 40°C. 3 IPLV: Energy efficiency index according to ARI STANDARD EMPE: Energy efficiency index according to AICARR For more informations about Energy Efficiency Indexes. please refer to “Energy Efficiency Indexes” bulletin of RC GROUP Technical Literature. SUPPLY VOLTAGE 400/3/50 + Mp On request 230/3/50 - 415/3/50. RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 11 -
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans ACOUSTIC DATA UNICO.A.ELN: Chiller in extremely low noise version. SOUND PRESSURE LEVEL (LP) Sound pressure level in free field conditions on condenser coil side. MODEL Sound pressure level 1m far 5m far 10m far MODEL Sound pressure level 1m far 5m far 10m far
dB(A) dB(A) dB(A)
dB(A) dB(A) dB(A)
21.Z.1
25.Z.1
32.Z.1
37.Z.1
50.Z.1
61.Z.1
56 42 36
59 45 39
57 43,8 37,8
59 45,8 39,8
60 47,5 41,6
61 48,5 42,6
36.Z.2
42.Z.2
50.Z.2
64.Z.2
74.Z.2
87.Z.2
100.Z.2
124.Z.2
59 45,8 39,8
57 44,5 38,6
61 48,5 42,6
61 48,5 42,6
59 48,5 42,6
62 51,5 45,6
62 51,5 45,6
63 52,5 46,6
MEAN SOUND PRESSURE LEVEL (LPm) Mean sound pressure level in free field conditions, according to ISO 3744 norm. MODEL Mean sound pressure level 1m far dB(A)
21.Z.1
25.Z.1
32.Z.1
37.Z.1
50.Z.1
61.Z.1
50
53
51
53
54
55
MODEL Mean sound pressure level 1m far dB(A)
36.Z.2
42.Z.2
50.Z.2
64.Z.2
74.Z.2
87.Z.2
100.Z.2
124.Z.2
53
51
55
55
53
56
56
57
IMPORTANT For further information about units acoustic data, please refer to “The Noise” bulletin of RC GROUP Technical Literature.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 12 -
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans ELECTRICAL DATA MAXIMUN ELECTRIC ABSORPTION CALCULATION Through this chapter it is possible to calculate the unit maximum electric absorption (A), according to extreme working conditions. The involved components are the following: - Cooling compressors electric motor - Condenser fans electric motor - Water pump electric motor (if present) The electric data of the components are indicated on relative technical data tables. EXAMPLE: Calculation for UNICO.A.STD. 21.Z.1 unit with PU 1/1 pumping group: MAXIMUM ELECTRIC ABSORPTION - Compressors A 17,0 + - Condenser fans (*) A 3,5 + - Water pump (*) A 1,7 = Maximum electric absorption A 22,2
To obtain the unit electric absorption values with different feeding voltage, please refer to the following coefficients:
Feeding voltage 230.3.50 415.3.50
Coefficient 1,73 0,97
IMPORTANT For water pumps and condenser fans, the values of the nominal electric absorption have been assumed to be same as plate current ones. In the normal operation the electric absorption is lower than the plate current. These values depend on the operating conditions of the unit and control of the system.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 13 -
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans OPTIONAL CHILLED WATER TANKS Available for all air cooled liquid chillers, size G0 excluded. This optional is made by 2 insulated water tanks, closed in a galvanized steel sheet box and painted. The tank is supplied assembled under the unit, ready to work and with antifreeze electric heater.
CHILLER SIZE Capacity Water inlet Water discharge Air discharge Empty weight Dimensions
l Ø Ø MPT Ø MPT kg A B C D E F G 5
Fixing holes
mm mm mm mm mm mm mm N° x Ø mm
G2 250 2" MPT 1/2" 1/2" 200
G4 360 2 1/2" MPT 1/2" 1/2" 280
G6 - G7 530 3" MPT 1/2" 1/2" 390
1.040 1.120 1.210 80 2.000 170 -4x16
1.200 1.290 1.400 200 2.600 100 -4x20
1.290 1.380 1.520 200 3.600 100 1.600 6x20
CHILLED WATER TANKS
G2 - G4 2 3 1
5
5
50
50
300 195
350
4
50
A
D
5
5
D
F
B C
E
G6 - G7 2 3 1
5
5
50
A
50
50
300 195
350
4
D F
B
G
G
5
C
5 E
1. 2. 3. 4. 5.
Water inlet. Water outlet. For exact position see the drawing of the chiller. Pipe for air discharge. Pipe for water drain. Fixing holes.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 14 -
D 5
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans OPTIONAL CONDENSING HEAT RECLAIM SYSTEMS TOTAL HEAT RECLAIM The system is totally controlled by the microprocessor. The heat reclaim exchangers are installed on every gas circuit of the unit in parallel to the main condenser. The ON-OFF heat reclaim system’s operation is subject to the supply demand of cooling capacity. The heat reclaim device is controlled by a probe placed on the water inlet of the heat reclaim exchangers which senses the water temperature coming from the plant and by a temperature differential which can be calibrated on the microprocessor. In the heat reclaim phase, a special valve which is fitted on the delivery pipeline deviates the gas towards the heat reclaim exchanger totally excluding the air cooled main condenser. In case of an anomalous condensing pressure rise which is caused, for example, by the absence of the hot water flow reclaim, the refrigerant gas is deviated on the main air cooled exchanger to guarantee the chilled water supply. If this inconvenience verifies more than three times in a certain time interval, the microprocessor disconnects the heat reclaim system and shows the anomaly by using an alarm on the display; this alarm is also available on voltage free contacts. In the units with a double refrigerant circuits, the heat reclaim hydraulic circuit is in parallel connected and the water temperature probe is already installed. A special anti-freeze heater avoids water freezing in case of a flow absence and/or in the periods of work suspension in winter season. In this series, welded plate heat exchangers in stainless steel AISI 316 are used. It is also possible to remote-control the connection or the disconnection of the total heat reclaim system thanks to the presence of special contacts on the electric box of the unit.
TOTAL HEAT RECLAIM
HEAT RECLAIM HYDRAULIC CIRCUIT
BGV
YR
SC
RU
A
YR COM B
SUCTION LINE
COM RU YR A B SC BGV
TO LIQUID RECEIVER
Compressor Manual valve Non return valve Gas/air heat exchanger Fan Heat reclaim exchanger Deviating valve
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 15 -
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans OPTIONAL CONDENSING HEAT RECLAIM SYSTEMS PARTIAL HEAT RECLAIM (desuperheaters) The partial heat reclaim exchangers are installed on every refrigerant circuit of the unit before the main condenser. The system is not regulated. In the units with double refrigerant circuit, the heat reclaim hydraulic circuit is in parallel connected. A special antifreeze heater avoids water freezing in case of a flow absence and/or in the periods of work suspension in winter season. Welded plate heat exchangers in stainless steel AISI 316 are used. The heating capacity which is supplied depends on the kind of refrigerant gas which is used and on working temperatures. Desuperheaters can produce hot water up to the maximum temperature of 70÷75°C and according to the working conditions of the unit.
PARTIAL HEAT RECLAIM
HEAT RECLAIM HYDRAULIC CIRCUIT
A
SC
B
RU
COM
TO LIQUID RECEIVER
SUCTION LINE
COM RU SC A B
Compressor Manual valve Heat reclaim exchanger Gas/air heat exchanger Fan
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 16 -
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans OPTIONAL PUMPING GROUPS In the chillers technical data tables are showed the pumping group type for each unit. The pumping group are factory assembled inside of the unit and they don't modify the water chiller dimensions. The piping line is insulated with closed cell polyurethane foam. VERSIONE AD 1 POMPA - PU.../1 Pumping group with one centrifugal pump. COMPONENTS - Control and working electric equipment built in the water chiller electric board and directly managed by the microprocessor control. - Expansion tank. - Safety valve on the water circuit. - 2 poles electric motor. TWO PUMPS VERSION - PU.../2 Pumping group with two centrifugal pumps. One pump is working and the other is in stand-by. Automatic changeover is made in case of failure. COMPONENTS - Control and working electric equipment built in the water chiller electric board and directly managed by the microprocessor control. - Expansion tank. - Safety valve on the water circuit. - 2 poles electric motor. - Ball valves. - Non return valves. - Water safety flow switch (one for each pump). - Water pressure gauges. 1 pump version 2 pumps version Min. water flow Max water flow Total pressure With min. water flow With max. water flow Installed power (1) Plate current (1) Net weight ../1 Net weight ../2 Sound pressure level (2)
m3/h m3/h
PU1/1 PU1/2 3 8
PU2/1 PU2/2 7 17
PU3/1 PU3/2 15 30
kPa kPa kW A kg kg dB(A)
205 160 0,55 1,7 50 85 69
235 180 1,5 2,9 70 110 70
225 175 2,2 5,3 74 112 70
(1) The given value is referred to the woring pump only. (2) Sound pressure level 1m far in free field conditions.
PUMPING GROUP SCHEME
PU.../1 MA
VE
PU.../2
YS
MA
P
MA
YS
FL RU
MA Manometer VE Expansion tank YS safety valve RU Manual ball valve P Water pump YR Non return valve FL Water flow switch
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
VE
RU
- 17 -
MA
P
P
FL YR
RU
FL YR
RU
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans OPTIONAL SILENCING PLENUM ON CONDENSER AIR DISCHARGE Supplied as separate accessory for installation at site. Same characteristics as the cabinet of the chiller, the plenum is supplied with built-in weatherproof noise absorption partitions. Thanks to the particular disposition of the noise absorption partitions, the air pressure drop across the plenum is zero. NOISE LEVEL REDUCTION The RC GROUP catalogues show the chillers noise pressure level on gas/air heat exchanger side. The noise pressure level on fans air discharge is always higher. With the plenum it is possible to reach, on fans air discharge side, a noise pressure level value of -3dB(A) lower than the nominal one (on gas/air heat exchanger side), for all the chillers. The plenum reduces only the noise level on fan air discharge side. No noise level reduction on the other unit sides. Example: Noise level 1m far on gas/air heat exchanger side in free field conditions for chiller UNICO.A.STD.21.Z.1 = 68 dB(A). Unit noise level 1m far on fans air discharge side in free field conditions: 68-3 = 65 dB(A).
750
SILENCING PLENUM ON AIR DISCHARGE
Chiller size Weight
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
kg
G0 50
- 18 -
G2 80
G4 110
G6 150
G7 150
UNICO.A.STD/ELN “G”
R407C
Air cooled liquid chillers with Scroll compressors and axial fans OPTIONAL SPRING ANTIVIBRATION HOLDERS Available on request for all liquid chillers. They are not installed on the chiller but supplied separately. The antivibration holders type and the positioning layout are showed in a specific drawing supplied with the chiller. The holders must be utilized only to eliminate the vibrations produced by the chiller. SPRING ANTIVIBRATION HOLDERS Type AxB C
C... Light Ø124 90
mm mm
R... Medium 114x174 90
G... Heavy 208x208 122
1 2 3 4 5 5 4 6 C
7
AxB 1. 2. 3. 4. 5. 6. 7.
Chiller frame. Hole for wrench. Screw-jack for unit levelling. Height setting nuts. Washers. Antivibration holder. Base.
RC GROUP S.p.A. - UNCSRL_AG_GB407_0203
- 19 -