Preview only show first 10 pages with watermark. For full document please download

Untitled

   EMBED


Share

Transcript

Congratulations and thank you for being a customer of Pretika! Before you start, please take a moment to get to know your OxySonic by carefully reading the Operating Instructions and Warranty Information included with your new product. OxySonic® Facial Brush Features Using OxySonic® Daily Treatment Use daily to remove the Epidermal (outer) layer of dry and flaky skin cells and reduce the appearance of fine lines and wrinkles so your skin feels smoother. Gentle enough for use as part of your daily beauty routine. Helps reduce appearance of pores, oily areas, dry skin patches and blemishes and prepares the skin to better absorb skin care treatments. Works great for removing makeup too! Your OxySonic can be used as a Facial Brush Only, a Facial Cleansing and Hydrating Sauna using the Oxygenated Hot or Cool mists only or use both features together to Exfoliate, Cleanse and Hydrate the skin – pore by pore. The OxySonic can be used separately or in combination with your daily skin care treatments. Hot Oxygenated Mist open pores to help extract impurities and help make skin healthier, smoother, glowing and vibrant. Cool Oxygenated Mist can increase the skin’s absorbance of skin care products, increase tightness of skin, close pores and help to smooth and reduce wrinkles. Oxygenated Mist helps oxygenate the fresh new skin cells exposed on the skins’ surface after exfoliation. 2 Getting Started Step 1: Filling your OxySonic® (If only using Facial Brush, skip to step 5) • Plug in the unit to wall adaptor and connect DC plug into the socket on the Make sure unit is unplugged. Press the tank release button on the top cover of the water tank. Using 2 fingers on the edge of the tank lift up. • Turn the tank upside down and open cap. • Fill the tank with distilled water (recommended) or fresh tap water to the designated level and close. base unit. • Oxygenated Mist Flow Control On/ Off located on base unit – turn clockwise for on position and adjust clockwise for higher mist flow and counterclockwise for lower mist flow. • Place the water tank back into the top cover, making sure the slots match up to the grooves and press tank release button to slide tank back into place. • In seconds you will see the Oxygenated Mist forming outside the Applicator (if no Mists are present, check water Tank level and fill), on the Facial Brush Handle – use the Oxygenated Mist Temperature Control to select cool or hot temperature. Pilot light on handle indicates the Heating Setting Button has been pressed ON. When Heat Setting Button is in OFF position – Pilot Light if OFF. Press firmly to treated area and move Facial Brush in an upward, circular motion. (See diagram on following page.) 3 Step 4: Empty Water Tank after each use. Make sure unit is unplugged. • Press the tank release button on the top cover, using 2 fingers on the edge of the tank and lift up. • Turn tank upside down and open cap, drain remaining water from tank and close cap. • Press 2 cover release buttons and carefully lift off cover. • Drain remaining water in reservoir and replace top cover by aligning into place and carefully pushing down until it snaps into place. • Place the water tank back into the top cover, making sure the slots match up to the grooves and press tank release button to slide tank back into place. Step 2: OxySonic® Exfoliate and Cleanse Turn on warm mist and hydrate face or dampen face with warm water. Press the Facial Brush to treated area and press Micro-Pulsating Cleansing On/Off button. Press firmly to treated area and move Facial Brush in an upward, circular motion. Recommended time per treated area is 20 seconds for each area - forehead, nose, chin and each cheek. Both the Micro-Pulsating Vibration Cleansing Technology and Oxygenated Mist Flow Control features can be used simultaneously – to exfoliate, cleanse, hydrate and oxygenate in on step. Step 5: Using Facial Brush Feature Only For Facial Brush operation only – simply: • Plug in the unit to wall adaptor and connect DC plug into the socket on the base unit. Step 3: for Use In Combination With Your Daily Beauty Routine OxySonic can be used with many of your daily beauty routines – from cleansers, scrubs to microdermabrasion crèmes. Turn on warm mist to hydrate face or dampen face with warm water, turn steam off and dot your face in five (5) areas: forehead, each cheek, chin and nose lightly with beauty treatments. • On the Facial Brush Handle – select either the On/Off “HI” or On/Off “LO” Micro Pulsating Cleansing Setting Buttons. Then Press firmly to treated area and move Facial Brush in an upward, circular motion. Move Facial Brush in an upward, circular motion to apply treatments. Gently rinse skin thoroughly with warm water and pat dry. 4 4. OxySonic is designed only for use on the counter top. Keep base unit away from water and do not get Facial Brush handle wet. To clean Facial brush applicators, remove from Facial Brush handle before cleaning. Replace Brush Heads as needed – they can be purchased at from your retailer or online at www.pretika.com. OxySonic® Unit Micro-Fiber Bristle Brush Heads – Attach and Remove 1. Do not use abrasive cleaners or chemi- cals to clean any part of the OxySonic. 2. Clean handle with damp cloth– using mild detergent or warm water and towel dry immediately. 3. On first use, wash water tank thoroughly. 4. After each use, remove Brush Head, drain out remaining water in tank, set the handle in compartment and keep tube in vertical position. 5. Unplug the Power Adaptor from the OxySonic unit before you clean using mild detergent or warm water and towel dry immediately. 6. Do Not bend the hose– maintain in upward or straight position during operation. If the hose does become bent, it may restrict the Oxygenated Mist Flow. If this occurs, simply hold the Facial Brush handle straight-up in the air to restore Oxygenated Mist Flow. To attach Brush Head, align “arrow” marks on the Brush Head to corresponding marks on Facial Brush handle. See illustration. Press from sides of the Brush Head and push down until it snaps into place. To remove the Brush Head, simply grip the outer plastic sides of the Brush Head Applicator firmly in one hand and the facial brush handle in the other hand– then pull-out evenly. Caring For Your OxySonic® Facial Brush Micro-Fiber Bristle Brush Heads 1. Clean Brush Heads after every use. Remove Brush Heads, rinse clean with warm water and mild soap to remove any build-up that may have accumulated, shake off excess water and towel dry – or gently rub the Brush Head against a towel for 5-10 seconds. Do not attach wet brush heads to handle. 2. Do not allow liquid cleansers or moisturizers to accumulate on Brush Heads or in the Oxygenated Mist Flow opening in the center of the brush applicator. 3. Unplug the power adaptor from unit before you clean. 5 Monthly Cleaning 1. 2. 3. 4. 5. 6. 7. Before cleaning, make sure unit is unplugged and cool. To clean base: if there is buildup on water groove, scrub off. After clean- ing, refill water tank 2/3 full, shake water tank and then open the cap to drain water. Repeat 3 or 4 times. Turn base over connect tube and handle several times until all the water comes out, repeat 3-4 times. Put handle back into holder. Keep the connecting tube upward. Plug in the unit, turn on Warm mist and try inside for 10 minutes, turn power off. BE CAREFUL NOT TO HAVE DRAIN- ING WATER FALL INTO CONTROLS OR VENT OPENINGS. DO NOT drain in any manner other than indicated. WARNING: DO NOT place directly under running faucet. Pour about 1 cup of white vinegar into water tank and allow it to soak for only 20 to 30 minutes. Remove any buildup of minerals in the water tank using a small brush, such as a toothbrush. NOTE: The buildup is due to water hardness. The harder your water, the more often this maintenance will be needed. Be careful not to use any metal blade on any plastic parts. DO NOT PLACE ON WET SURFACE 8. 9. Disinfect the water tank using a solution of one teaspoon of house hold chlorine bleach in 1 gallon of water. Let the solution sit for 20 min- utes, swishing every few minutes to wet all surfaces. Empty the tank completely; rinse thoroughly until all of the bleach smell is gone. Fill the tank with fresh, cool water (or dis- tilled water) and replace inside OxySonic base. NEVER use any metal or hard ob- jects to clean plastic parts which may cause scratching of the plastic parts. 10. Each day the reservoirs and tanks should be drained, rinsed and refilled Distilled water or with fresh tap water. 11. To clean exterior surfaces, use a solution of water and mild detergent with a wrung-out damp cloth. Rinse and wring out the cloth and wipe the exterior surfaces again. Finally, wipe with a dry cloth. Allow sufficient time to dry before plugging the electrical cord into the outlet. 12. After base is totally cleaned and dried, plug in the unit and resume normal use. Warning When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: Read all instructions before using the appliance. 1. 2. 3. 6 For external use only. Keep out of reach of children and please use as directed. Avoid contact with eyes. As with any product, dis continue use if rash, redness or itching occurs. Consult physician if irritation persists. Anyone suffering from acne or any skin disorder should consult physician before us- ing this product. Do not use on sore or injured areas. Do not apply extreme pressure when using unit or when replacing attach- ments. This could damage product. The attachments are delicate and must be attached and removed with care. Not following operating instructions carefully may result in damage to the OxySonic unit and attachments. Basic safety precautions should always be followed when using any electrical product, especially when children are present. 4. Do not place or store the adapter or unit where it can fall or be pulled into tub, sink, water or other liquid. 5. Do not reach for adapter or unit that has fallen into water, unplug immedi- ately. 6. Keep the cord away from heated surfaces. 7. Do not attempt to open the Brush Handle to clean the interior. 8. Do not plug into an incorrect voltage source outlet, use only with appro- priate voltage. 9. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 10. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers. 11. DO NOT place OxySonic near heat sources such as stoves, radiators, and heaters. DO locate your Oxy Sonic on an inside wall near an electrical outlet. 12. NEVER place OxySonic in an area where it is accessible to children. 13. WARNING: Do not attempt to refill OxySonic without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord. 14. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair. 15. Use the OxySonic appliance only for intended use as described in this manual. Any other use not recom- mended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments 7 not recommended or sold by the manufacturer may cause hazards. 16. DO NOT use outdoors. 17. Always place OxySonic on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the OxySonic. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by expo sure to water or moisture. 18. OxySonic should be unplugged when not in use. 19. NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. 20. NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the OxySonic. 21. DO NOT attempt to repair or adjust any electrical or mechanical func- tions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. 22. DO NOT place Facial Brush handle in water. Remove Applicators from Facial Brush to clean. 23. Never place housing under water flow or immerse in liquids. 24. Do not plug in the cord with wet hands: electric shock could result. 25. Do not pour water in any openings other than the water tank. 26. NEVER operate unit without water in the tank. 27. Use both hands when carrying full tank of water. 28. Fill the water tanks according to the instructions and place inside base correctly. 29. Whenever the water falls below the operating level shown on the tank, the Oxygenated Mist output will dis- sipate – indicting time to refill tank. 30. The OxySonic Oxygenated Mist Flow feature will operate as long as there is water in the tank. Storage Tips 31. DO NOT move or tilt OxySonic while it is operating. 32. The OxySonic should not be left unattended in a closed room with the Oxygenated Mist Flow feature in the ON mode since air could become saturated and leave condensation on walls or furniture. 33. This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. 34. Caution: To avoid the risk of fire, shock or personal injury, do not use an extension cord. 35. Do not add any medications to the Water Tank. Do not cover, or insert objects into, any openings on the unit. 36. Do not leave water in the base reser voir for long periods between use. Water contains minerals and other particles. During operation most of these minerals will remain in the water reservoir. Gradual buildup of deposits will coat the hot water reservoir and reduce its efficiency. The importance of routine cleaning and care can not be over-empha- sized. Hard water contains more minerals and other particles. If you do not plan to use your OxySonic for an extended period of time it is important that you follow these instructions to help prevent problems from developing in the unit. 1. Clean your OxySonic as instructed in the section title Cleaning and Main- tenance. 2. Make sure all water is emptied from the tanks and the hot and cold water reservoirs. 3. Dry your unit thoroughly. 4. Leave the tank cap off to expose the tank to air. 5. Pack your OxySonic in its original carton and store it in a cool, dry place. 8 Limited 90 Day Warranty along with a check or money order payable to Pretika Corporation in the amount of $50.00 to cover handling and processing charges. Warranted from date of purchase against defects in material and workmanship. This warranty does not include damage to the product as a result of misuse or accident. Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary, from state to state. Pretika Corporation shall not be liable for any incidental or consequential damages arising out of defects in this product, whether or not caused by its negligence. To Order Applicator Replacement Sets Visit our website at www.pretika.com– to see the innovative beauty, skin care, spa and personal care products from Pretika. Click on “Replenishment Sets” link to order using a credit card on our secure site. Mail or fax orders to: During Warranty Period with Proof of Purchase (store receipt) Should your product become defective during the warranty period, package the item securely and return it prepaid/ insured– along with proof of purchase to: Pretika Corporation Warranty Repair Department 12215 Holly Street Riverside, CA 92509 USA Pretika Corporation Replacement Parts Department 12215 Holly Street, Riverside, CA 92509 (949) 481-8818 Fax (949) 481-8828 E-Mail: [email protected] Website: www.pretika.com Customer Service For questions or assistance relating to the use of this product – or for information on all of the innovative Beauty, Skin Care, Spa and Personal Care product manufactured by Pretika, contact our Customer Service Team at 949 4918818 Phone (8:00 to 5:00 PM, Pacific Standard time, Monday through Friday), 949-481-8828 Fax or by email at [email protected]. To insure prompt repair, provide complete, legible name, address and phone number information and a note indicating the nature of the product defect. We will Repair or Replace (at our sole discretion) product at no charge. Outside Warranty Period Should your product become defective outside the warranty period – or you do not have store receipt, package the item securely and return it prepaid/insured 9 Trouble shooting Experiencing Reason What to Do Base Unit Pilot Light is not on Adaptor not connected to power socket on base unit or wall outlet or base unit cover is not on correctly Check power connections, make sure base unit cover to water reservoir is snapped into place correctly Pilot Light on without Oxygenated Mist Flow through the Facial Brush Applicator Water Tank is empty Fill water tank Oxygenated Mist has a slight odor New OxySonic unit or not fresh water A new OxySonic unit after a few uses will correct this – or change water in tank and reservoir in based unit (use Distilled or fresh tap water) Oxygenated Mist Flow output is low Clean Atomizing unit, refill Dirt on Atomizing Disc or too little water in Tank and water level (use Distilled in tank and reservoir in or fresh tap water) based unit Abnormal Noise Low water level in tank or reservoir in based unit, base unit not on flat surface. Refill to proper level in water in based unit (use Distilled or fresh tap water), place base unit on flat surface Press Heating On/Off, Vibration “HI” or “LO” Buttons on Facial Brush Handle and no activation Adaptor not connected to power socket on base unit or wall outlet or base unit cover is not on correctly Check power connections, make sure base unit cover to water reservoir is snapped into place correctly Turned ON Oxygenated Mist Flow Knob and no flow is activated through the Facial Brush Applicator Water Tank is empty, blockage in hose– restricting the Oxygenated Mist Flow Fill water tank, hold the Facial Brush handle straight-up in the air to restore Oxygenated Mist Flow through the hose Read and Save These Instructions 10 Specifications Wattage Water Tank Capacity 48W 380 mL 12.8 Fl. Oz. Cool Mist: 50F ~ 79F 10-20º C Temperature Range Warm Mist: 100F ~ 132F 40-60º C At high Oxygenated Mist Flow setting the volume output is 65mL (2.1 mL) per hour for 2 hours of use Oxygenated Mist Duration At low Oxygenated Mist Flow setting the volume output is 45mL (1.5 mL) per hour for 3 hours of use Output Rating Adaptor 24VDC, 2.0A Input : 100~240Vac 50Hz/60Hz Output : 24Vdc 2.0A 11