Transcript
U PATC H FA C T S H E E T ( PA G E 1 O F 1 )
UPatch™
100% SOLIDS EPOXY FLOOR PATCH & CRACK FILLER UPatch is a two component 100% solids epoxy crack filler designed for shallow repair on either vertical or horizontal surfaces. Available in light gray or beige, UPatch is easy to mix and use and has a non-critical mix ratio. Additionally, the product, because it is a 100% solids formulation, can be applied thicker on horizontal surfaces when required. UPatch is applied between the bond and finish coats of the UCoat epoxy base system. Apply after UCoat bond coat is completely tack-free and dry to the touch (approx 4-6 hours at 68°F). Recommended for: Repairing cracks and defects in concrete or masonry.
Physical Properties Physical properties are typical values and not specifications. Solids by Weight: Mixed=100% Solids by Volume: Mixed=100% Volatile Organic Content: Zero (0) pounds per gallon Recommended Film Thickness: 1/8” cracks or thin build repairs Coverage per Gallon: 0.13 cubic feet or 1,228 lineal feet @ 1/8” bead Mix Ratio: 1 : 1 — one Part A to one Part B by volume Available colors: Light Gray and Beige Packaging Information: This product is available in 2-quart kits (light gray or beige) and 2-gallon kits (light gray only). Shelf Life: 1 year in unopened containers Heat deflection temp: 59°C (138°F) Flexural Strength: 7,500 psi @ ASTM D790 - ½” x ½” bars span 4” Yield Compressive Strength: 8,710 psi @ ASTM D695 - ½” x ½” bars Tensile strength: 6,256 psi @ ASTM D638 - testing dimensions F=2.25”, W=0.500”, T=0.125”, D=4.5” and rate = 0.2”/minute Ultimate elongation: 2.4% Gardner variable impactor: 50 inch pounds direct - passed Abrasion resistance: Taber abraser cs-17 calibrase wheel with 1000 gram total load and 500 cycles = 36 mg loss Adhesion: 350 psi @ elcometer (concrete failure, no delamination) Hardness: Shore D = 65 Application Temperature: 60-90° F Viscosity: Mixed = >3,100,000 cps (typical)
Cure Schedule: (70°F) Pot life (2 gallon volume)............................................................. 1-3 hrs Tack free.................................................................................... 5-10 hrs Recoat or top coat.............................................. immediately if desired* Light foot traffic........................................................................ 10-24 hrs Full cure (heavy traffic)..............................................................2-7 days * for best finish results, allow UPatch to become tack-free before recoating. Chemical Resistance: Reagent........................................................................................ Rating Butanol................................................................................................. C Xylene.................................................................................................. B 1,1,1 Trichloroethane............................................................................ A MEK...................................................................................................... A Methanol............................................................................................... A Ethyl alcohol......................................................................................... A Skydrol................................................................................................. B 10% Sodium hydroxide........................................................................ E 50% Sodium hydroxide........................................................................ D 10% Sulfuric acid.................................................................................. C 70% Sulfuric acid.................................................................................. A 10% HCl (ag)........................................................................................ C 5% acetic acid...................................................................................... A Rating key: A – not recommended, B – 2hr term splash spill, C – 8 hr term splash spill, D – 72 hr immersion, E – long term immersion. Primer: None necessary. Top Coat: Optional: this product can be overcoated with most UCoat It epoxy and urethane products. DOT Classification: Part A - not regulated Part B - Corrosive liquid N.O.S., 8, UN1760,“PGIII” Limitations: • Color stability may be affected by environmental conditions such as high humidity or chemical exposure. • Colors may vary from batch to batch. • This product is not uv color stable, but has good resistance to color change for an epoxy product. Substrate temperature must be 50 F above dew point. All new concrete must be cured for at least 30 days prior to application. • Many epoxy products can be placed directly over the uncured epoxy crack filler immediately after the material is used provided that the cracks are small. If coating over repairs that are larger, it may be advisable to allow the material to become tack free prior to application of subsequent coatings.
Disclaimer: The information contained herein relates only to the specific material identified. UCoat It America, LLC (“UCoat It”) believes that such information is accurate and reliable as of the date of this MSDS sheet, but no representation, guarantee or warranty, expressed or implied, is made as to the accuracy, reliability, or completeness of the information. UCoat It urges persons receiving this information to make their own determination as to the information’s suitability and completeness to their particular application. UCoat It assumes no responsibilities for injury from the use of this product. It is the buyer’s / users responsibility to ensure that all activities comply with the appropriate federal, state, and local laws.
Distributed by: UCoat It America, LLC 1797 Atlantic Blvd., Auburn Hills, MI 48326
REVISED 07/2012
M AT E R I A L S A F E T Y D ATA S H E E T ( PA G E 1 O F 2 )
UPatch™ Part A
100% SOLIDS EPOXY FLOOR PATCH & CRACK FILLER Section 1 - Manufacturer Identification Manufacturer’s Name: UCoat It America, LLC.
Emergency Phone: Chemtrec - 1(800) 424-9300
Address: 1797 Atlantic Blvd., Auburn Hills, MI 48326
Information Phone: 1(800) 826-2848
Date Revised: 08-26-09
Name of Preparer: UCoat It America, LLC.
Section 2 - Composition / Information on Ingredients
Hazardous Components
Occupational Exposure Limits
CAS Number
OSHA PEL
ACGIH TLV
Vapor Pressure
OSHA STEL
mm Hg@ Temp
Weight Percent
Reaction Products of Epichlorohydrin
Bisphenol A
25068-38-6
None
None
None
Extender Non Hazardous in Liquid Form
None
5MG/M3
None
Extender Non Hazardous in Liquid Form
20MG/M3
20MG/M3
20MG/M3
Extender Non Hazardous in Liquid Form
None
5MG/M3
None
Benzyl Alcohol
None
None
None
100-51-6
Section 2 Notes: *No toxic chemicla(s) subject reporting requirements of section 313 of Title III and of 40 CFR 372. Section 3 - Hazards Identification Effects of Overexposure Acute Effects:
EYES: Direct contact may cause slight to moderate irritation.
SKIN: May cause allergic skin reactions and / or central nervous system depression.
INHALATION: May cause slight irritation to respiratory passages – headache – dizziness.
INGESTION: Low ingestion hazard in normal use.
Prolonged / Repeated Exposure Effects:
SKIN: May cause allergic skin reactions, defatting, drying, and dermatitis.
INHALATION: No applicable information available.
INGESTION: May cause adverse kidney effects.
OTHER: Some adverse reproduction effects have been reported in animals.
Section 4 - First Aid Measures Emergency First Aid Procedures: EYES: Flush with large volumes of water for 15 to 30 minutes. Remove contacts after the first 2 minutes of flushing. Get medical attention. SKIN: Wash with soap and water or waterless cleanser. Get medical attention if irritation develops or persists. INHALATION: Move to fresh air. Get medical attention. INGESTION: Do not induce vomiting. Seek medical attention from a physician. Never give anything by mouth to an unconscious person. OTHER: No ingredient in this product is an IARC, NTP or OSHA listed carcinogen. Section 5 - Fire Fighting Measures Flash Point: 200+°F Flammable Limits in Air (% by volume):
Upper: N/A
Lower: N/A
Method Used: Seta flash Extinguishing Media: Alcohol Foam,Carbon Dioxide, Dry Chemical, Foam, or Water Fog Unusual Fire and Explosion Hazards: None known Special Fire Fighting Procedures: Water can be used to cool fire-exposed containers. Self-contained breathing apparatus and protective clothing should always be worn when fighting large fires involving chemicals.
M AT E R I A L S A F E T Y D ATA S H E E T ( PA G E 2 O F 2 )
UPatch™ Part A
100% SOLIDS EPOXY FLOOR PATCH & CRACK FILLER Section 6 - Accidental Release Measures In the Case of Accidental Release or Spill: Follow all recommendations regarding Personal Protective Equipment. Preferred method would be to scrape up spilled material and place in secondary container for disposal. Smaller spills can also be wiped up. Residual material can be removed with the assistance of hot water and soap. White water should be captured and contained for disposal. Disposal Method: All material must be disposed in accordance with Federal, State, and Local Regulations. This includes any white water created in the cleaning of the spill. Section 7 - Handling and Storage Handling And Storage: Store in a cool, dry place. Keep away from food, feed, or drinking water. Keep container closed when not in use. Section 8 - Exposure Controls / Personal Protection Personal Protection: RESPIRATORY PROTECTION: Use a NIOSH approved respirator as required to prevent over exposure to vapor in accordance with 29 CFR 1910.134. General exhaust is usually in lieu of NIOSH respirator. SKIN PROTECTION: Chemical resistant gloves are recommended for prolonged exposure. Clothing should be such that it protects skin from direct contact with sealant. EYE PROTECTION: Safety glasses with side shields (ANSIZ87.1 or approved equivalent). Other Protective Equipment: None required. Section 9 - Physical and Chemical Properties Appearance: Viscous Paste - Negligible odor . Boiling Point: 200°F to 401°F Vapor Density (Air = 1): N/A Evaporation Rate: N/A Water Solubility: Negligible Section 10 - Stability and Reactivity Stability: Stable Conditions to Avoid: Avoid excessive heat or open flames Incompatibility (Material to Avoid): Can react vigorously with strong oxidizing agents and strong lewis acids or mineral acids. Hazardous Polymerization: Will not occur Hazardous Decomposition Or By-Products: CO2, aldehydes, acids, reaction with some suring agents can generate large amounts of heat Section 11 - Disposal Considerations Waste Disposal Method: All waste must be disposed in accordance with Federal, State, and Local Regulations (see 40 CFR Part 268).
Disclaimer: The information contained herein relates only to the specific material identified. UCoat It America, LLC (“UCoat It”) believes that such information is accurate and reliable as of the date of this MSDS sheet, but no representation, guarantee or warranty, expressed or implied, is made as to the accuracy, reliability, or completeness of the information. UCoat It urges persons receiving this information to make their own determination as to the information’s suitability and completeness to their particular application. UCoat It assumes no responsibilities for injury from the use of this product. It is the buyer’s / users responsibility to ensure that all activities comply with the appropriate federal, state, and local laws.
Distributed by: UCoat It America, LLC 1797 Atlantic Blvd., Auburn Hills, MI 48326
REVISED 07/2012
M AT E R I A L S A F E T Y D ATA S H E E T ( PA G E 1 O F 2 )
UPatch™ Part B
100% SOLIDS EPOXY FLOOR PATCH & CRACK FILLER HMIS Hazard Classification Health: 2 Flammability: 1
Reactivity: 0
Personal Protective Equipment: G
Section 1 - Manufacturer Identification Manufacturer’s Name: UCoat It America, LLC. Address: 1797 Atlantic Blvd., Auburn Hills, MI 48326 Date Revised: 08-26-09
Emergency Phone: Chemtrec - 1(800) 424-9300 Information Phone: 1(800) 826-2848 Name of Preparer: UCoat It America, LLC.
Section 2 - Composition / Information on Ingredients Hazardous Components
CAS Number
Triethylene Tetramine 112-24-3 Dimer/Tofa, Reaction Products with Teta 68082-29-1 Alkylated Phenol 31091-95-9 Benzyl Alcohol 100-51-6 *Xylene 1330-20-7 Carbon 1333-86-4 Extender Non Hazardous in Liquid Form Extender Non Hazardous in Liquid Form Extender Non Hazardous in Liquid Form
Occupational Exposure Limits OSHA PEL
ACGIH TLV
OSHA STEL
None None None None 100PPM 3.5PPM None 20MG/M3 None
None None None None 100PPM 3.4PPM 5MG/M3 20MG/M3 5MG/M3
None None None None 150PPM None None 20MG/M3 None
Vapor Pressure mm Hg@ Temp
Weight Percent
Section 2 Notes: *Indicates toxic chemical(s) subject to the reporting requirements of section 313 of Title III and of 40 CFR 372 are present. Xylene Acgih Stel=150PPM Section 3 - Hazards Identification Effects of Overexposure:
EYES: Will cause burns to eyes. High vapor concentrations can cause severe irritation to the eyes.
SKIN: Will cause burns to the skin.
INHALATION: High concentrations of vapor can cause irritation to the respiratory tract, nausea and dizziness.
INGESTION: Liquid can cause severe damage to mucous membrane if swallowed.
Section 4 - First Aid Measures Emergency First Aid Procedures: EYES: Flush with large volumes of water for 15 to 30 minutes. Remove contacts after the first 2 minutes of flushing. Get medical attention. SKIN: Wash with soap and water or waterless cleanser. Get medical attention if irritation develops or persists. INHALATION: Move to fresh air. Get medical attention. INGESTION: Do not induce vomiting. Seek medical attention from a physician. Never give anything by mouth to an unconscious person. OTHER: No ingredient in this product is an IARC, NTP or OSHA listed carcinogen. Section 5 - Fire Fighting Measures Flash Point: 200+°F Flammable Limits in Air (% by volume):
Upper: N/A
Lower: N/A
Method Used: Seta flash Extinguishing Media: Alcohol Foam,Carbon Dioxide, Dry Chemical, Foam, or Water Fog Unusual Fire and Explosion Hazards: None known Special Fire Fighting Procedures: Water can be used to cool fire-exposed containers. Self-contained breathing apparatus and protective clothing should always be worn when fighting large fires involving chemicals.
M AT E R I A L S A F E T Y D ATA S H E E T ( PA G E 2 O F 2 )
UPatch™ Part B
100% SOLIDS EPOXY FLOOR PATCH & CRACK FILLER Section 6 - Accidental Release Measures In the Case of Accidental Release or Spill: Follow all recommendations regarding Personal Protective Equipment. Preferred method would be to scrape up spilled material and place in secondary container for disposal. Smaller spills can also be wiped up. Residual material can be removed with the assistance of hot water and soap. White water should be captured and contained for disposal. Disposal Method: All material must be disposed in accordance with Federal, State, and Local Regulations. This includes any white water created in the cleaning of the spill. Section 7 - Handling and Storage Handling and Storage: Store in a cool, dry place. Keep away from food, feed, or drinking water. Keep container closed when not in use. Section 8 - Exposure Controls / Personal Protection Personal Protection: RESPIRATORY PROTECTION: Use a NIOSH approved respirator as required to prevent over exposure to vapor in accordance with 29 CFR 1910.134. General exhaust is usually in lieu of NIOSH respirator. SKIN PROTECTION: Chemical resistant gloves are recommended for prolonged exposure. Clothing should be such that it protects skin from direct contact with sealant. EYE PROTECTION: Safety glasses with side shields (ANSIZ87.1 or approved equivalent). Other Protective Equipment: None required. Section 9 - Physical and Chemical Properties Appearance: Viscous Paste with amine odor Boiling Point: 279°F to 401°F Vapor Density (Air = 1): N/A Specific Gravity (H2o=1): 1.5 Evaporation Rate: N/A Water Solubility: Negligible Section 10 - Stability and Reactivity Stability: Stable Conditions to Avoid: Avoid open flames and all sources of ignition and sparks Incompatibility (Material to Avoid): Avoid contact with strong oxidizing agents mineral acids and epoxy resins in uncontrolled amounts. Hazardous Polymerization: Will not occur Hazardous Decomposition Or By-Products: CO2, CO amd NOX Section 11 - Disposal Considerations Waste Disposal Method: All waste must be disposed in accordance with Federal, State, and Local Regulations (see 40 CFR Part 268).
Disclaimer: The information contained herein relates only to the specific material identified. UCoat It America, LLC (“UCoat It”) believes that such information is accurate and reliable as of the date of this MSDS sheet, but no representation, guarantee or warranty, expressed or implied, is made as to the accuracy, reliability, or completeness of the information. UCoat It urges persons receiving this information to make their own determination as to the information’s suitability and completeness to their particular application. UCoat It assumes no responsibilities for injury from the use of this product. It is the buyer’s / users responsibility to ensure that all activities comply with the appropriate federal, state, and local laws.
Distributed by: UCoat It America, LLC 1797 Atlantic Blvd., Auburn Hills, MI 48326
REVISED 07/2012