Transcript
UPS Catalog
KEHUA TECH
HISTORY
2
2012 Set up 30,000 M Xiamen new factory 2
Set up 80,000 M Jiaomei factory for wind turbine and solar system producing
2011 Introduced ERP systems for processing management. 2010 Kehua officially went public and listed in Shenzhen Stock Exchange Joint-venture company NHEOLIS was set up, which is mainly producing wind turbine.
2009 Recognized as “UPS Well-known Trademark” by government 2008 Passed Ohsas18001 authentication 2
2006 Set up 70,000 M production base Complied with RoHS requirement
2005 Passed ISO14001 authentication 2002 Implemented 6sigma management system 2001 Set up EMC test center 2000 Developed no-master-slave parallel UPS and won the national patent 1999 Transformed into private enterprise 1997 Exported UPS to Japan, America etc. 1995 Passed the ISO9001 authentication 1988 Company established
CONTENTS
Kehua Group ----------------------------------------------02 Applications / Qualifications ------------------------------------03 Products---------------------------------------------------FR-UK11 Series Online UPS (1-15kVA) ----------------------------------------04 FR-UK31 Series Online UPS(10-50kVA) ----------------------------------------06 FR-UK33 Series Online UPS(10-500kVA) ---------------------------------------08 FR-UK33A Series Online UPS(10-200kVA) --------------------------------------10 KR11 Series Online UPS (1-10kVA) ------------------------------------------12 KR11A Series Online UPS (1-10kVA) -------------------------------------------14 KR-J Series Online UPS (1-10kVA) --------------------------------------------16 KRA-J Series Online UPS (1-5kVA) -------------------------------------------18 KR31 Series Online UPS (10-20kVA) -------------------------------------------20 KR33 Series Online UPS (10-60kVA) -------------------------------------------22 KR33 Series Online UPS (80-120kVA) ------------------------------------------24 MR Series Modular UPS(10-480kVA) -------------------------------------------26 KI Series Sine-wave line interactive UPS (1-5kVA) ---------------------------------27 Mini-guard Series Off line UPS (500-2000VA) -------------------------------------28 DJN Series 48Vdc Inverter (1kVA-12kVA) ----------------------------------------29 DXB Series 48Vdc Inverter (3kVA-30kVA) ----------------------------------------30 Li UPS Series Sine Wave UPS ------------------------------------------------31 KTS dual input redundant static switch -------------------------------------------32 MMBM-3 Intelligent battery monitoring system ------------------------------------32
The Option for UPS and other products ---------------------------33
Kehua Group
Telecom
Industry
Finance
Electric Power
Traffic
Medical Device
Data Center
Renewable Energy
KEHUA TECH ------ CREDIBLE POWER PROTECTOR Stock NO.: 002335 Kehua, as the leading high-end power solution provider in mainland China, was founded in 1988. On Jan. 13th 2010, Kehua officially went public and was listed on the Shenzhen Stock Exchange, which is the first public UPS manufacturer in mainland China. With 25 years’ expertise in power technology, Kehua’s products have been installed in more than 80 countries and regions. Covering 180,000㎡ land areas, Kehua owns 5 subsidiaries, 1 joint venture company, 4 production bases, 3 research centers, one EMC test center and UL Witness Test Data Program, over 2000 employees, including more than 250 R&D engineers. Products range: Line-interactive UPS, Online double conversion UPS (1kVA to 500kVA), Modular UPS (10kVA to 480kVA), Outdoor UPS, EPS, Telecom inverter, On-grid & Off-grid solar system, Wind turbine and Hybrid wind-solar street light and etc.
Listed on Shenzhen Stock Exchange
Zhangzhou factory
Shenzhen factory
Xiamen factory
Jiaomei factory
Applications /Qualifications
Applications With high reputation and good service in electrical & electronic field, Kehua has participated and undertaken many power projects for key events, such as The 16th Asian Games, 2010 Shanghai EXPO, Angolan Luanda Stadium (for 2010 African Cup football games), 2008 Beijing Olympic Games, The Golden Tax Project…
Qualifications Being the qualified high-end UPS manufacturer, Kehua passed ISO9001 authentication in 1995, ISO14001 in 2005 and OHSAS18001 in 2008. With years’ efforts in extending global market, UPS with CE, CB, TUV, KC, SONCAP certificates are available to meet different market requirements.
OHSAS 18001
ISO9001
ISO14001
03
FR-UK 11 Series Online UPS (1-15kVA)
FR-UK 11 Series Online UPS (1-15kVA)
Main Features: ●
Online double conversion
●
Output isolation transformer
●
Wide input voltage range
●
Full protection function
●
High reliability and performance
●
Intelligent RS232 /RS485& DB9 dry contact communication port
●
Management software (optional)
●
External battery bank (optional)
●
SNMP adapter or USB (optional)
Application:
04
●
IT device
●
Data center
●
Commercial facility
●
Telecommunication
●
Industry
Specification:
MODEL
FR-UK10/ FR-UK10L
FR-UK20/ FR-UK20L
FR-UK30/ FR-UK30L
FR-UK50/ FR-UK50L
FR-UK60/ FR-UK60L
FR-UK1110S/ FR-UK1110
FR-UK1115S/ FR-UK1115
INPUT Voltage (Vac)
220/230/240V MODEL:165-275
Frequency (Hz)
110/120V MODEL: 85~137
50/ 60±5% (50/60Hz settings)
Phase
Single phase three wires OUTPUT
Capacity(VA/W)
1000/700
2000/1400
Voltage range(Vac)
3000/2100
5000/3500
6000/4200
10000/7000
15000/10500
32×7Ah12V/ External
48×7Ah12V/ External
220/230/240±2% or 110/120±2%
Frequency (Hz)
50 / 60 ±0.5%(battery mode)
Waveform
Pure Sine wave,THD<3% (Linear load )
Transfer Time
0
Overload
125% load for 60 seconds , 150% load for 1second BATTERY
Voltage (Vdc) BATT Type Charger Current(A)Max
48
96/192
192
4×7Ah12V/ External
8×7Ah12V/ External
8×7Ah12V/ External
16×7Ah12V/ External
16×7Ah12V/ External
1/4.5
1/4.5
1/4.5
1/4.5
1/4.5
3/4.5
OTHER Communication Interface Display
RS232,dry contact ( USB and SNMP adapter are optional) LCD display input voltage, output voltage, load capacity, battery voltage, etc.LED indicates running status
Alarm
Overload, abnormal AC input, low battery
Protection
Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
Noise ( dB )
≤55
Working Temperature
0~40℃
Relative humidity Dimension (W×D×H)(mm) Weight (kg) Standard/ Long backup
0~95%(no condensation) 230×620 × 470 48/36
230×635× 690/230×620× 470 74/49
82/44
90/45
91/47
400×800×1180/ 300×590×700
400×800×1180
210/85
288/145
◆ Specification is subject to change without prior notice. ◆ 110V, 120V systems are available with some different parameters.
05
FR-UK 31 Series Online UPS (10-50kVA)
FR-UK31 Series Online UPS(10-50kVA)
Main Features: ● Online double conversion ● IGBT inverter and output isolation transformer ● High reliability DSP control ● Wide input voltage range ● DC cold start function ● Full protection function ● Intelligent RS232 /RS485 & DB9 dry contact communication port ● SNMP adapter (optional) ● Advanced no-master-slave parallel technology (optional) ● Intelligent battery monitors system - MMBM (optional)
Application:
06
●
Computer room
●
Data center
●
Precision instrument
●
Intelligent equipment
Specification:
MODEL
FR-UK3110S/ FR-UK3110
FR-UK3315S/ FR-UK3115
FR-UK3120
FR-UK3130
FR-UK3140
FR-UK3150
INPUT Voltage(Vac)
380 ±25%
Frequency(Hz)
50/60 ±5%
Phase
Three phase in single phase out(L1,L2,L3,N,G) OUTPUT
Capacity (KVA / KW)
10/7
15/10.5
20/16
Voltage (V)
40/32
50/40
220 ±1%
Frequency(Hz)
50/60±0.5% (battery mode)
Waveform Overload
30/24
Pure sine wave THD <3% (linear load) 125% load for 1 minute, 150% load for 1 second
125% load for 1 minute, 150% load for 20 seconds
Transfer Time
0 BATTERY
Voltage (Vdc) BATT Type
192 32×7Ah12V/ External
Charger Current(A)Max
348 48×7Ah 12V/ External
External
3/5
10~20 setting OTHER
Maintenance Bypass Switch
Optional
Communication Interface Display
Standard
RS232/RS485 and dry contact (MODBUS and SNMP adapter are optional) LCD Display indicates frequency, voltage, load, battery voltage, etc.LED indicates running status
Alarm
Low battery, abnormal AC input, overload, UPS failure
Protection
Low battery, overload, output over voltage, short-circuit, over temperature
Noise (dB)
<60
<65
Working Temperature
0 ~ 40℃
Relative Humidity Dimension (W×D×H)(mm) Weight (kg) Standard/ Long backup
0 ~ 95%, No condensation 400×800×1180/ 350×780×720
230/130
320/160
400×800×1180 205
230
270
300
◆ Specification is subject to change without prior notice. ◆ For Parallel system, Maintenance Bypass Switch is not available.
07
FR-UK 33 Series Online UPS(10-500kVA)
FR-UK 33 Series Online UPS(10-500kVA)
Main Features: ●
Online double conversion
●
IGBT inverter and output isolation transformer
●
3 phases UPS allow 100% unbalance load
●
Fully DSP control,high reliability and performance
●
Wide input voltage range
●
DC cold start function
●
Advanced battery charging management
●
Intelligent fan speed control
●
ECO mode and EPO function.
●
Intelligent RS232/RS485,DB9 Dry contactor communication port
●
SNMP adapter (optional)
●
Advanced no-master-slave parallel technology (optional)
●
Intelligent battery monitor system - MMBM (optional)
●
12 Pulse rectifier (optional)
●
Bypass isolation transformer (optional)
Application: ●
Computer room
●
Data center
●
Precision instrument
● Intelligent equipment
08
Specification:
MODEL
FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK FR-UK 3310/FR- 3320/FR- 3330/FR3350 3360 3380 33100 33120 33160 33200 33300 33400 33500 UK3310S UK3320S UK3330S 3340
INPUT Voltage(Vac)
380/400/415±20%
Rectifier Frequency
40~65
SYNC Frequency Tracking
50/60±5% (±10% optional)
Phase
3φ4W+PE OUTPUT
Capacity (KVA/KW)
10/8
20/16
30/24
40/32
50/40
60/48
Power Factor
80/64
100/80 120/96 160/128 200/160 300/240 400/320 500/400
0.8 (PF=0.9 optional)
Phase
3φ4W+PE
Voltage (Vac)
L-N:220/230/240±1%, L-L:380/400/415±1%,
Frequency(Hz)
50/60±0.5% (battery mode)
Waveform
Pure sine wave, THD≤3% (linear load)
3 Phases 100% Load Unbalance Voltage Stability
≤2%,allow 100% unbalance
Overload
110% load for 30 mins, 125% load for 10 mins, 150% load for 1min. BATTERY
Voltage (Vdc) BATT Type
12V×29=348 External /Max 7Ah 12V 58pcs
External
Charger Current(A)Max
10~40A setting
Battery Self-testing
20~80A setting
Automatically alarm and estimate battery status in battery abnormal status OTHER
Maintenance Bypass
Yes
Communication Interface Display
RS232/RS485 and dry contact(MODBUS and SNMP adapter are optional) LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
Alarm
Overload, abnormal AC input, low battery, UPS failure
Protection
Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
Noise (dB)
< 65
Working Temperature
0 ~ 40℃
Relative Humidity Dimension (W×D×H)(mm) Weight(kg)
0 ~ 95%, No condensation 500×800×1180/ 500×800×1700 200/380 240/420 290/470
800×800×1600
450
470
490
1600x1000 4200×1000 2200×1000×2000 x1800 ×2000
1000×800×1800
690
730
780
980
1190
2350
2580
3300
◆ Specification is subject to change without prior notice.
09
FR-UK 33A Series Online UPS(10-200kVA)
FR-UK 33A Series Online UPS(10-200kVA)
Main Features: ●
Online double conversion
●
IGBT inverter and output isolation transformer
●
3 phases UPS allow 100% unbalance load
●
Fully DSP control, high reliability and performance
●
Wide input voltage range
●
DC cold start function
●
Advanced battery charging management
●
Intelligent fan speed control
●
ECO mode and EPO function.
●
Intelligent RS232/RS485 communication port
●
SNMP adapter (optional)
●
Advanced no-master-slave parallel technology (optional)
●
Intelligent battery monitor system - MMBM (optional)
●
Bypass isolation transformer (optional)
Application: ●
Computer room
●
Data center
●
Precision instrument
● Intelligent equipment
10
Specification:
MODEL
FR-UK 3310A/FRUK3310AS
FR-UK 3320A/FRUK3320AS
FR-UK 3330A/FRUK3330AS
FR-UK 3340A
FR-UK 3350A
FR-UK 3360A
FR-UK 3380A
FR-UK 33100A
FR-UK 33120A
FR-UK 33160A
FR-UK 33200A
100/80
120/96
160/128
200/160
INPUT Voltage(Vac)
208/220 ±20% (±25% optional)
Rectifier Frequency
40~65
SY N C Fre quenc y Tracking
50/60±5% (±10% optional)
Phase
3φ4W+PE OUTPUT
Capacity (KVA/KW)
10/8
20/16
30/24
40/32
50/40
60/48
Phase
80/64
3φ4W+PE
Voltage (Vac)
L-N:120/127±1%, L-L:208/220±1%,
Frequency(Hz)
50/60±0.5% (battery mode)
Waveform
Pure sine wave, THD≤3% (linear load)
3 Phases 100% Load Unbalance Voltage Stability
≤2%,allow 100% unbalance
Overload
110% load for 30 mins, 125% load for 10 mins, 150% load for 1 min. BATTERY
Voltage (Vdc) BATT Type
12V×16=192
12V×29=348
External /Max 7Ah 12V 64pcs
External
Charger Current(A) Max
10~40A setting
Battery Self-testing
Automatically alarm and estimate battery status in battery abnormal status OTHER
Maintenance Bypass
Yes
Communication Interface
RS232/RS485 and dry contact (MODBUS and SNMP adapter are optional)
Display
LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
Alarm
Overload, abnormal AC input, low battery, UPS failure
Protection
Low battery, overload, over temperature, short circuit, output over voltage, output low voltage
Noise (dB)
<65
Working Temperature
0 ~ 40℃
Relative Humidity Dimension (W×D×H)(mm) Weight(Kg)
0 ~ 95%, No condensation 500×800×1180 /500×800×1700 300/500
325/530
340/540
800×800×1600
590
620
1600×1000 ×2000
1400×800×1800
670
970
1000
1200
1450
1700
◆ Specification is subject to change without prior notice.
11
KR11 Series Online UPS (1-10kVA)
KR11 Series Online UPS (1-10kVA)
Main Features: ●
Online double conversion
●
High input power factor
●
Wide input voltage range
●
Full protection function
●
Automatic bypass
●
High reliability and performance
●
Intelligent RS232 communication port
SNMP
SIGNAL
NetAgent Mini
● 6KVA & 10KVA have ECO&EPO function
1
RS232
RS232
USB
RS232
● THDi≤5% (6KVA & 10KVA) 3 ● UPS management software (optional) ●
SNMP or USB or dry contact (optional)
●
External battery bank (optional)
●
Output transformer for 6KVA&10KVA (optional) 2
RS232
5
Application:
AC OUTPUT 4.5A Max.
AC INPUT
4
●
Data center
●
Point-of-sale
Application:
FUSE 250V/10A
3
1
●
Router
●
Hub and other network device
●
Commercial facility
●
Precision instrument
1kVA Rear panel:
RS232
1. Communication interface 2 5
2. AC output sockets 3. External battery connector 4. AC input socket
AC OUTPUT 4.5A Max.
AC INPUT
4 FUSE 250V/10A
12
5. Fan
Specification:
MODEL
KR1000/KR1000L
KR2000/KR2000L
KR3000/KR3000L
KR6000/KR6000L
KR1110S/KR1110
INPUT Voltage (Vac)
120-295 (120-140:50% load;140-160:75% load; 160-295:100% load)
Frequency (Hz)
120~276 (120-140:50% load;140-160:75% load;160-276:100% load)
50/60± 5% (50/60Hz ±10%settings)
Power Factor
≥0.99 OUTPUT
Capacity(VA/W)
1000/700
Power Factor
2000/1400
3000/2100
0.7 (PF=0.8 or 0.9 optional)
Voltage (Vac)
10000/8000
0.8(PF=0.9 optional) 220/230/240±2%
Frequency(Hz)
50/60±0.2%(battery mode)
Waveform
Pure sine wave THD < 3% (linear load )
Transfer Time Overload
6000/4800
0 105%~129% for 60 seconds, 130%~150% for 30 seconds, above 150% for 300ms
105%~129% for 10minutes, 130~150% for 1 minute, above150% for 1 second.
BATTERY Voltage(Vdc) BATT Type Charger Current(A)Max
36
72
96
192
3×7Ah12V/ External
6×7Ah12V/ External
8×7Ah12V/ External
16×7Ah 12V/External
1/5
1/5
1/5
1/6
OTHER Communication Interface Display
RS232 (Dry contact, USB and SNMP adapter is optional)
RS232+USB+EPO (Dry contact, SNMP, MBS are optional)
LED indicates the status of UPS (LCD is optional)
LCD & LED display
Alarm
Low battery, abnormal AC input, UPS failure
Protection
Low battery, overload, short-circuit and over temperature
Noise (dB)
< 45
Working Temperature
0 ~ 40℃
Relative Humidity Dimension (W×D×H) mm Standard/ Long backup Weight (kg) Standard/ Long backup
< 60
0 ~ 95%, No condensation 156×400×220 13/7
255×565×700/255×565×500
198×490×347 25/14
29/15
69/23
70/24
◆ Specification is subject to change without prior notice.
13
KR 11A Series Online UPS (1-10kVA)
KR 11A Series Online UPS (1-10kVA)
Main Features: ●
Online double conversion
●
High input power factor
●
Wide input voltage range
●
Full protection function
●
Automatic bypass
●
High reliability and performance
●
Isolation output transformer for 6 and 10KVA
●
THDi≤5% (6KVA and 10KVA)
●
Dual Output 208V/120V voltage (6KVA and 10KVA)
●
Intelligent RS232 communication port
●
UPS management software (optional)
●
SNMP or USB or dry contact (optional)
●
EPO for 5KVA, 6KVA and 10KVA
●
Manual bypass switch optional for 5KVA,6KVA and 10KVA
●
External Battery Bank (optional)
Application:
Application:
14
●
Data center
●
Point-of-sale
●
Router
●
Hub and other network device
●
Commercial facility
●
Precision instrument.
Specification:
MODEL
KR1000A/ KR1000AL
KR2000A/ KR2000AL
KR3000A/ KR3000AL
KR5000A/ KR5000AL
KR6000T/ KR6000TL
KR1110T
INPUT Voltage (Vac)
80~148
60~138
Frequency (Hz)
120~276 (L1, L2, G)
50/60Hz±5%
Power Factor
>0.99 at full load OUTPUT
Capacity(VA/W)
1000/700
2000/1400
3000/2100
5000/3500
6000/4200
10000/7000
Power Factor
0.7 (PF=0.8 optional)
0.7
Voltage (Vac)
100/110/120/127±2%
200/208/220/230/240±2% or 110/120±3%
Frequency(Hz)
50/60±0.2%(battery mode)
Waveform
Pure sine wave THD < 3% (linear load )
Transfer Time Overload
0ms 105%~129% for 60 seconds, 130%~150% for 30 seconds, above 150% for 300ms
105%-129% load for 10 minutes 130%-149% load for 1 minute above 150% load for 1 second
105%~129% for 10minutes, 130~150% for 1 minute, above150% for 1 second.
BATTERY Voltage(Vdc) Internal BATT Type Charger Current(A)Max
36
72
96
3×7Ah12V / External
6×7Ah12V / External
1/5
1/5
8×7Ah12V/ External
192 16×7Ah12V/ External
16×7Ah12V/ External
External
1/5
5
1/5 OTHER
Communication Interface
RS232 (USB or Dry contact or SNMP adapter is optional)
Display
LCD display parameters of UPS
Alarm
Low battery, abnormal AC input, UPS failure
Protection
Low battery, overload, short-circuit and over temperature
Noise (dB)
< 45
< 60
Working Temperature
0 ~ 40℃
Relative Humidity Dimension (W×D×H) mm Weight (kg)
0 ~ 95%, No condensation 156×400×220 13/7
198×490×347 28/16
34/17
255×565×700/255×565×500 70/24
255×650×790 147/105
107
◆ Specification is subject to change without prior notice.
15
KR-J Series Online UPS (1-10kVA)
KR-J Series Online UPS (1~10kVA)
Main Features: ●
Online double conversion
●
Rack and tower convertible
●
High input power factor
●
Wide input voltage range
●
Compact and light weight
●
High reliability and performance
●
Full protection function &Automatic bypass
●
Intelligent RS232 communication port
●
6KVA & 10KVA UPS have ECO&EPO function
●
THDi≤5% (6KVA & 10KVA)
●
UPS management software (optional)
●
SNMP, USB, dry contact (optional)
●
External battery bank, Tower housing, Rack kits (Optional)
Application: ● 19”rack device
● Computer room
● Data center
● Point-of-sale
Application:
● Hub and network device ● Precision instrument. SNMP
1kVA Rear panel:
SIGNAL
RS232
RS232
USB
NetAgent Mini
● Router ● Commercial facility
AC INPUT
USB
AC OUTPUT 10A Max.
NetAgent Mini
RS232
RS232
RS232
SNMP
SIGNAL
DC INPUT FUSE 250V/10A
1 AC INPUT
RS232
AC OUTPUT 10A Max.
2
6
3
4
5
DC INPUT FUSE 250V/10A
2
3
16
4
5
1. DC input cover
4. AC output socket
2. DC input port
5. Fan
3. AC input socket
6. Communication interface
6
Specification:
MODEL
KR1000-J/ KR1000L-J
KR2000-J/ KR2000L-J
KR3000-J/ KR3000L-J
KR6000-J/ KR6000L-J
KR1110S-J/ KR1110-J
INPUT Voltage (Vac)
120-295 (120-140:50% load;140-160:75% load; 160-295:100% load)
Frequency (Hz)
120~276 (120-140:50%load; 140160:75%load; 160-276:100% load)
50/60± 5% (50/60Hz ± 10%settings)
Power Factor
≥0.99 OUTPUT
Capacity (VA/W)
1000/700
Power Factor
2000/1400
3000/2100
0.7 (0.8 or 0.9 optional)
10000/8000
0.8 (0.9 optional)
Voltage (Vac)
220/230/240±2%
Frequency (Hz)
50/60±0.2%(battery mode)
Waveform
Sine wave, THD<3% at linear load
Transfer Time Overload
6000/4800
0 105%~129% for 60 seconds, 130%~150% for 30 seconds, above 150% for 300ms
105%~129% for 10minutes, 130%~150% for 1 minute, above 150% for 1 second.
BATTERY Voltage (Vdc) BATT Type Charger Current(A)Max
36
72
96
192
3×7Ah12V/ External
6×7Ah12V/ External
8×7Ah12V/ External
16×7Ah 12V/External
1/5
1/4
1/4
1.5 (2.5A is optional)
OTHER Communication Interface Display
RS232 (Dry contact, USB or SNMP adapter is optional)
RS232+USB+EPO (Dry contact or SNMP are optional)
LED indicates the status of UPS (LCD is optional)
LCD & LED display
Alarm
Low battery, abnormal AC input, UPS failure
Protection
Low battery, overload, short-circuit and over temperature
Working Temperature
0~40℃
Relative Humidity Dimension (W×D×H) mm Standard/ Long backup Weight (kg) Standard/ Long backup
0~95%,No condensation 440×500×2U
440×500×2U(UPS)+ 440×500×2U (Battery pack)/ 440×500×2U(UPS)
14/7
10+22/12
11+28/13
440×550×3U(UPS)+ 440×550×3U (Battery pack)/ 440×550×3U(UPS) 21+53/ 21
◆ Specification is subject to change without prior notice.
17
KRA-J Series Online UPS (1~5kVA)
KRA-J Series Online UPS (1~5kVA)
Main Features: ●
Online double conversion
●
Rack and tower convertible
●
High input power factor
●
Wide input voltage range
●
Compact and light weight
●
High reliability and performance
●
Full protection function &Automatic bypass
●
Intelligent RS232 communication port
●
5KVA UPS has ECO&EPO function
●
UPS management software (optional)
●
SNMP, USB, dry contact (optional)
●
External battery bank, Tower housing, Rack kits (Optional)
Application: ● Computer room
● Data center
● Point-of-sale
● Router
● Hub and network device
● Commercial facility
● Precision instrument.
Application:
SNMP
1kVA Rear panel:
SIGNAL
RS232
RS232
USB
NetAgent Mini
● 19”rack device
AC INPUT
USB
AC OUTPUT 10A Max.
NetAgent Mini
RS232
RS232
RS232
SNMP
SIGNAL
DC INPUT FUSE 250V/10A
1 AC INPUT
RS232
AC OUTPUT 10A Max.
2
6
3
4
5
DC INPUT FUSE 250V/10A
2
3
18
4
5
1. DC input cover
4. AC output socket
2. DC input port
5. Fan
3. AC input socket
6. Communication interface
6
Specification:
MODEL
KR1000A-J/KR1000AL-J KR2000A-J/ KR2000AL-J KR3000A-J/ KR3000AL-J KR5000A-J/ KR5000AL-J INPUT
Voltage (Vac)
80~148
60~138
Frequency (Hz)
50/60± 5% (50/60Hz ± 10%settings)
Power Factor
≥0.99 OUTPUT
Capacity (VA/W)
1000/700
2000/1400
Power Factor
3000/2100
0.7 (PF=0.8 optional)
Voltage (Vac)
110/120±2%
Frequency (Hz)
50/60±0.2%(battery mode)
Waveform
Sine wave, THD<3% at linear load
Transfer Time Overload
5000/3500
0ms 105%~129% for 60 seconds, 130%~150% for 30 seconds, above 150% for 300ms
105%~125% for 10minutes, 125~150% for 1 minute, above150% for 1 second.
BATTERY Voltage (Vdc) BATT Type Charger Current(A)Max
36
72
96
96
3×7Ah12V/ External
6×7Ah12V/ External
8×7Ah12V/ External
16×7Ah 12V/External
1/5
1/4
1/4
1/3
OTHER Communication Interface
RS232 (Dry contact, USB or SNMP adapter is optional)
RS232+USB+EPO (Dry contact or SNMP are optional)
LED indicates the status of UPS
LCD & LED display
Display Alarm
Low battery, abnormal AC input, UPS failure
Protection
Low battery, overload, short-circuit and over temperature
Working Temperature
0~40℃
Relative Humidity
0~95%,No condensation
Dimension (W×D×H)(mm) Standard/Long backup
440×500×2U
Weight(kg) Standard/long backup
14/7
440×500×2U(UPS)+ 440×500×2U(Battery pack)/ 440×500×2U(UPS) 10+22/12
11+28/13
440×550×3U(UPS)+ 440×550×3U(Battery pack)/ 440×550×3U(UPS) 18+48/18
◆ Specification is subject to change without prior notice.
19
KR31 Series Online UPS (10-20kVA)
KR31 Series Online UPS (10-20kVA)
Main Features: ●
Online double conversion
●
High reliability DSP control
●
Advanced PFC technology
●
Wide input voltage range
●
DC cold start function
●
Intelligent fan speed control
●
Full protection function
●
Advanced battery charging management
●
Intelligent RS232+USB+EPO communication port
●
SNMP adapter or dry contact (optional)
●
Advanced no-master-slave parallel technology (optional)
Application: ● IT device ● Data center ● Precision instrument ● Intelligent equipment
20
Specification:
MODEL
KR3110S/KR3110
KR3115
KR3120
INPUT Voltage (Vac)
380/400/415±25%(-45% in half load)
Frequency (Hz)
50/60 ±10%
Power Factor
≥0.95
Phase
3φ4W+PE
Bypass Voltage (Vac)
180-255 OUTPUT
Capacity (KVA/KW)
10/8
15/10.5
Voltage(Vac)
20/14
220/230/240 ±2%
Frequency(Hz)
50/60±0.2%(battery mode)
Waveform
Pure sine wave THD <3% (Linear load)
Overload
105%~125% load for 10 mins,126%~150% load for 1 min, above150% load for 1 second
Transfer Time
0
Efficiency
90%(linear load)
Crest Factor
3:1 BATTERY
BATT Voltage(Vdc) BATT Type Charger Current(A )Max
192
240
16×7Ah 12V/ External
External
1/6
2.5 OTHER
Maintenance Bypass Switch
Optional
Communication Interface Display
Standard
RS232+USB+EPO (SNMP adapter, Dry contact are optional) LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
Alarm
Low battery, abnormal AC input, Overload, UPS failure
Protection
Low battery, overload, short-circuit, UPS failure, and input over/low voltage
Noise(dB)
<60
Working Temperature
0 ~ 40℃
Relative Humidity Dimension (W×D×H) mm Standard/Long backup Weight (kg) Standard/ Long backup
0 ~ 95%, No condensation 255×565×700/255×565×500 71/23
255×740×790 62
63
◆ Specification is subject to change without prior notice.
21
KR33 Series Online UPS (10-60kVA)
KR33 Series Online UPS (10-60kVA)
Main Features: ●
Online double conversion
●
Fully DSP control
●
Advanced PFC technology, high input power factor
●
High reliability and performance
●
Wide input voltage range
●
DC cold start function
●
Advanced battery charging management
●
Intelligent fan speed control
●
ECO mode and EPO function
●
Full protection function
●
Intelligent RS232 /RS485 Communication Port
●
DB9 dry contact, maintenance Bypass
●
SNMP adapter (optional)
●
Advanced no-master-slave parallel technology (optional)
●
Intelligent battery monitor system - MMBM (optional)
Application: ● Computer room ● Data center ● Precision instrument ● Commercial facility ● Intelligent equipment
22
Specification:
MODEL
KR3310S/ KR3310
KR3320S/ KR3320
KR3330S/ KR3330
KR3340
KR3350
KR3360
50/40
60/48
INPUT Voltage (Vac)
380/400/415±25% (-45% in half load)
Frequency (Hz)
50/60 ±10%
Bypass Voltage (Vac)
380/400/415+15%(+20% can choose)/-25%
Power Factor
≥0.99
Phase
3φ4W+PE OUTPUT
Capacity (KVA/KW)
10/8
20/16
30/24
Power Factor
40/32
0.8 (PF=0.9 optional)
Voltage (Vac)
L-N:220/230/240±2%
Frequency (Hz)
L—L:380/400/415±2%
50/60±0.2%(battery mode)
Phase
3φ4W+PE
U n b a l a n c e t h re e - p h a s e voltage stabilization with full load
≤2%
Waveform
Pure sine wave, THD<3% at linear load
Transfer Time
0
Efficiency
≥91%
Overload
130% load for 1 minute, 150% load for 10 seconds BATTERY
Battery voltage (Vdc) BATT Type Charging Current (A) Max
348 29×7Ah12V/ External
58×7Ah12V/ External
58×7Ah12V/ External
External
1/3
2/5
2/5
3A(6A is optional)
OTHER Maintenance Bypass
Yes
Communication Interface Display
RS232/RS485, DB9 dry contact (MODBUS and SNMP adapter are optional) LCD Display indicates frequency, voltage, load, battery voltage, etc. LED indicates running status
Alarm Protection
AC input abnormal, low battery, overload, failure Output short-circuit, overload, over-temperature, battery low voltage, output over/low voltage
Noise(dB)
<65
Working Temperature
0~40
Relative Humidity Dimension (W×D×H) mm Standard/ Long backup Weight (kg) Standard/ Long backup
0 ~ 95%, No condensation 400×800×1600 / 400×800×1180 200/105
210 / 115
330 / 125
500×800×1600 215
235
255
◆ Specification is subject to change without prior notice.
23
KR33 Series IGBT UPS (80-120kVA)
KR33 Series IGBT UPS (80-120kVA)
Main Features: ●
Online double conversion, three phases input, three phases output
●
IGBT rectifier, high input power factor
●
High reliability and performance
●
Wide input voltage range
●
DC cold start function
●
Advanced battery charging management
●
Intelligent fan speed control
●
ECO mode and EPO function
●
Full protection function
●
Intelligent RS232 /RS485 & dry contact communication function
●
Maintenance Bypass
●
SNMP adapter (optional)
●
Advanced no-master-slave parallel technology (optional)
●
Intelligent battery monitor system - MMBM (optional)
Application: ● Computer room ● Data center ● Precision instrument ● Commercial facility ● Intelligent equipment
24
Specification:
MODEL
KR3380/ KR/B3380
KR33100/ KR/B33100
KR33120/ KR/B33120
INPUT Voltage range(Vac)
380/400/415±25%
Rectifier frequency(Hz)
50/60±10%Hz
B y p a s s sy n c h r o n i z a t i o n tracking range(Hz)
50/60±5%(±10% option)
Bypass voltage range(V)
+15%(+20% optional)/-25%
Power factor(PF)
≥0.99
THDI
<5%
Phase
3φ4W+PE
Battery voltage(VDC)
480V(32~40 Selectable)
Charging current(A)
10A (18A-option) OUTPUT
Capacity(kVA/KW)
80/64
100/80
Power Factor
120/96
0.8 (PF=0.9 optional)
Phase
3φ4W+PE
Waveform
Pure sine wave
Voltage(Vac)
L-N: 220/230/240±1%, L-L: 380/400/415±1%
Frequency(Hz)
50/60±0.2%(battery mode)
Three phase difference
≤2 degrees
Waveform distortion
THD≤3%(Linear load)
Static bypass transfer time(ms)
0
System efficiency
≥92.0%
Parallel mode
Advanced no-master-slave parallel technology, N+1 redundancy
Overload capacity
130% load for 1 minute, 150% load for 10 seconds OTHER
Maintenance bypass
With no transfer time maintenance bypass switch
DC cold start function LCD display
Yes Three-phase input voltage, input frequency, three-phase output voltage, load, battery voltage, battery charge and discharge current, etc.
LED display
UPS working status and fault indication
Alarm function Communication function Battery monitoring(option) Protection function
Input abnormal, battery undervoltage, overload, fault. Provides dry contact communication and RS232/RS485 (SNMP options to achieve a smart UPS monitoring). MMBM battery monitoring system, real-time monitoring of single-cell work status Output short circuit protection, overload protection, over temperature protection, Battery low voltage protection, output overvoltage / undervoltage protection
EMC
Meet CE requirement
Noise(dB)
≤67 (1 meter from the front cabinet)
Cooling
Forced air cooling
Working temperature(℃)
0-40
Dimension(WxDxH)(mm) Weight(kg)
850×800×1800 470
480
480
◆ Specification is subject to change without prior notice.
25
MR Series Modular UPS(10-480kVA)
MR Series Modular UPS(10-480kVA) Main Features: ●
Modular parallel redundant N+X design for easy expansion
●
Hot swappable modules ensure online maintenance
●
Power modules share one battery bank
●
Multi-setting of 4 kinds of working modes: (3/3, 3/1, 1/1, 1/3)
●
Green power design: efficiency ≥95%
●
Clean power: input PF ≥0.99, THDi ≤5%
●
Input/output isolation transformer and EPO (optional)
Specification: Model Maximum Capacity Power Module I N P U T
MR-100 100KVA MRJ-10
MR-150 150KVA MRJ-15
MR-200 200KVA
Configuration
3 phase 4 wires + ground
Power Range
380/400/415±25%
Frequency Range
≥0.99
THDi
≤5%
Batteries(Vdc)
Frequency Range Voltage Stability
±384Vdc 0.8 Synchronizing with AC input when its frequency are within 50/60Hz±2% with phase shift less than 3 degree. 50/60Hz±0.2% at battery mode 380/400/415±1% (static), 380/400/415±2% (Load 0~100%)
Transient Recovery Time
20ms(loads 0~100%)
Overload
125% loads for 10 minutes, 150% loads for 1 minute
Transfer Time
0ms
Efficiency
O T H E R S
≥95%(AC-AC)
Communication Interface
Dry contact, RS232/RS422
SNMP Adapter
Yes
Display
LCD + LED
Working Temperature
-5℃~40℃
Relative Humidity
≤95% No condensation
Protection Degree
IP30
Noise Power Module Dimension (W×D×H) mm Power module weight (kg) Cabinet Size (W×D×H) mm Cabinet Weight (kg)
≤55dB 482×465×133 16kgs
18kgs
20kgs
600×800×2000
1400×800× 2000
2000×800× 2000
200
450
700
◆ Specification is subject to change without prior notice. 26
MR-480 480KVA
50/60Hz ± 10%
PF
PF
O U P U T
MR-240 240KVA MRJ-20
KI Series Sine-wave Line Interactive UPS (1~5kVA)
KI Series Sine-wave line interactive UPS (1~5kVA) Main Features: ● Digital technology ● Intelligent battery charger ● Reliable online interactive design ● Intelligent regulation system on utility power voltage ● Fully functional protection ● Intelligent RS232 Communication Port ● UPS management software (optional) ● External SNMP or USB or Dry contactor (optional) ● External battery bank (optional)
Specification: MODEL
KI1000
KI1000L
KI2000
KI2000L
KI3000
KI3000L
KI5000L
INPUT Voltage (Vac)
150-300
Frequency (Hz)
50/60 ± 5% (50/60Hz settings) OUTPUT
Capacity(VA/W)
1000/700
2000/1400
Voltage (Vac)
3000/2100
5000/3500
220/230/240±2% (battery mode)
Frequency (Hz)
50 /60± 0.1% (battery mode)
Waveform
Pure sine wave, THD < 3%
Transfer Time
Typically 4ms (Synchronous switch-over)
15ms
Utility mode: 150% for 5 minutes, above 200% for 3 seconds Battery mode: 120% for 30 seconds, above 150% for 1 second
Overload
BATTERY Voltage (Vdc) BATT Type Charger Current(A)Max
24
48
72
48
2×7Ah12V
External
4×7Ah12V
External
6×7Ah12V
External
External
1
10
1
10
1
10
30
OTHER Communication Interface
RS232. (Dry contact, USB and SNMP adapter are optional)
Display
LED or LCD display operation status of UPS
Alarm
Low battery, abnormal AC input, UPS failure
Protection
Low battery, overload, short-circuit and over temperature
Dimension (W×D×H)mm
156×450×220
Weight (kg)
16
13
255×590×495
198×525×347 35
26
44
30
52
◆ Specification is subject to change without prior notice.
27
Mini-guard Series Off line UPS (500-2000VA)
Mini-guard Series Off line UPS (500-2000VA) Main Features: ●
Advanced digital control technology
●
Streamline, colorful appearance design
●
Comprehensive net equipment protection
●
Green idea environmental design
●
Flexible and practical cold start function
●
Wide voltage range for intellectual regulating (SMART AVR)
●
Intelligent power management (optional)
Specification:
MODEL
UPS500
UPS700/ UPS1000/ UPS1600/ UPS2000/ SUPS500 UPS700L UPS1000L UPS1600L UPS2000L
SUPS700 SUPS1200
INPUT Voltage(Vac)
140~280 / 90~145
Frequency (Hz)
190~265
50/60 ± 10% OUTPUT
Power(VA/W)
500/300
Voltage(Vac)
220/230±10% ;110/120±10% (on battery mode)
Frequency(Hz) Transfer Time
700/420
1000/600 1600/960 2000/1200
500/300
700/420
1200/720
220/230±10%(on battery mode) Synchronizing with input AC while it is normal, and 50±0.5% or 60 ± 0. 5% on battery mode Typical 6ms, including detection time and switching time (Synchronous switchover)
Waveform
Square wave
Pure sine wave
BATTERY Voltage (Vdc) BATT Type Charger Current(A)Max
12 1×7Ah 1
12
12/24
36
36/48
1×7Ah/ 2×7Ah/ 3×7Ah/ 3×9Ah/ External External External External 1/8
1/6
1/5
12
24
1×7Ah
1/5
24 2×7Ah
1
OTHER Communication Interface
RS232, RJ11 / RJ45 (USB and SNMP adapter are RS232 (USB,SNMP adapter optional) are optional)
Display
LCD display show status of AC input, inverter, low battery, overload and battery capacity, or LED indicators show status of AC input, inverter, low battery, overload
Dimension (W×D×H) Weight(kg)
90×325×165/ 120×395×220 5
5.5/8
120×395 ×220 11/8
156×450×220 17/13
18/14
◆ Specification is subject to change without prior notice.
28
120×250 ×170 5
120×380×170 8
9
DJN Series 48Vdc Inverter (1kVA-12kVA)
DJN Series 48Vdc Inverter (1kVA-12kVA) DJN series inverters adapt to telecom systems with 48VDC power supply, adopting high efficiency SPWM inversion technology. DJN series inverter can be connected to teleprinter, telegraph terminal, wireless paging equipment, data switching exchange, local exchange, microwave communication equipment, program controlled exchange charging system, fax machine and all kinds of AC instrument, computer equipment and various communication equipment. Meanwhile, DJN-K Series inverter "on ECO mode" can be used for air conditioner, such as 3KVA for 1.5P and 5KVA inverter for 3P air conditioner.
Main Features: ●
Compliant with communication standard of AC and DC power supply system
●
High performance SPWM inversion technology
●
Wholesome protective measures
●
Low DC end current noise
Specification: Model
DJN1000-K / DJN2000-K / DJN3000-K / DJN3000-P / DJN1500-K DJN5000-K DJN1000-J DJN2000-J DJN3000-J DJN-S12 INPUT
Voltage (Vdc)
40-57
46-56
OUTPUT Capacity (VA/W)
1000/700
1500/1050
Voltage (Vac)
2000/1400
3000/2100
5000/3300
3000/2100 (N+X)
110/220/230±2%
Waveform
Sine wave, THD<3%
Frequency (Hz)
50/60±0.5%
50/60±1%
OTHER Panel Display Protection
LED indicators show status of inverter’s operation Low battery, over voltage, overload, short-circuit and over temperature.
Communication Interface
dry contact / RS232
dry contact
Dimension (WxDxH) (mm)
440×286×1U / 440×465×2U
440×360×1U
6/10
8
Weight (kg)
dry contact +RS232 / RS232
dry contact +RS232 / RS232
dry contact + dry contact + RS232 RS232 (system)
440×460×2U / 440×460×2U / 435×358×2U / 440×440×3U 440×465×2U 440×465×2U 445×335×10U 10/11
10/12
14
8.5/15
◆ Specification is subject to change without prior notice.
29
DXB Series 48Vdc Inverter (3KVA -30KVA)
DXB Series 48Vdc Inverter (3KVA -30KVA) DXB Series inverters are suitable for the power circumstance equipped with 48Vdc source such as post, telecommunication, railway and sailing. These inverters allow direct AC or DC power from power room. Internal isolated transformer isolates AC and DC terminal completely. It can save large investment by joining the rectifier and inverter in one equipment.
Main Features: ●
Meet the standard of telecommunication AC&DC power supply
●
Intelligent RS232 communication function
●
AC and DC complete isolation
●
Perfect protection measures
●
User-friendly panel
●
Low cost
Specification:
MODEL
DXB 11-3KVA
DXB 12-6KVA
DXB DXB DXB DXB 19-10KVA 19-15KVA 19-20KVA 19-30KVA
INPUT Voltage (Vac)
165~275
380/400±20%
Frequency (Hz) Phase
50/60±5% Single phase three wires
Three phase five wires
Battery voltage (Vdc)
48 OUTPUT
Capacity (VA/W)
3000/2100
6000/4200
10000/7000
Voltage (Vac)
15000/ 10500
20000/ 16000
30000/ 24000
220/230±2%
Frequency (Hz)
50/60±0.5% (battery mode)
Waveform
Sine wave, THD<3%
Overload capacity
125% load lasts for 1 minute; 150% load lasts for 1 second OTHER
Transfer Time (ms)
0
Alarms Protection functions
Low battery, abnormal AC input, inverter failure Low battery, over voltage, overload, short circuit and over temperature
Panel Indicators
LED & LCD display
Communicationinterface Dimension (W×D×H)(mm) Weight (kg)
RS232, RS485 and dry contact; SNMP is optional 230×620×470 230×635×690 50
70
480×860×1090
480×860×1090(inverter) + 480×860×1090(boost box)
175
203+105
◆ Specification is subject to change without prior notice.
30
210
225+130
Li UPS Series Sine Wave UPS
Li UPS Series Sine Wave UPS Li UPS is intelligent UPS with Lithium batteries. Li UPS has high performance, reliable and fully protection function. With small and exquisite appearance, visual display and easy operation feature, LiUPS provide pure and stable AC power to computers and peripheral equipment. Lithium batteries have higher safety, more reliability and longer lifetime. It is a good replacement to lead-acid battery which has pollution, low energy ratio, big size and short cycling lifetime.
Main Features: ●
Anti-feedback function, double output is available: AC output and 48V DC output
●
Low THD, with pure sine wave output
●
Advanced digital control technique
●
Comprehensive net equipment protection
●
Special Li battery charger
●
DC cold start and automatic start at low voltage
●
Intelligent power management (optional)
●
Green power, high efficiency
Specification: Model
UPS500S UPS500Li
UPS1000S UPS1000Li
UPS1500Li
UPS2000Li
UPS3000Li
UPS5000Li
INPUT Voltage(Vac)
220/230 ± 20%
220/230 ± 25%
Input frequency (Hz)
50/60 ± 10%
DC input(VDC)
24V
48V OUTPUT
Power(VA/W) AC Voltage(Vac)
500VA/350W
1000VA/700W
1500VA/1050W
220/230±10%(on battery mode)
Frequency(Hz)
2000VA/1400W
3000VA/2100W
5000VA/3300W
220/230±2%(on battery mode) 50/60 ± 0. 5%
Transfer Time
<6ms
<10ms
Waveform
Pure Sine Wave BATTERY
Voltage (Vdc)
24V
48V
BATT Type
Lithium battery / External
External
Charger Current(A)Max
0.7-1A / Max. 4A(external BAT)
2.5±0.5A OTHER
Communication Interface
RS232 or dry contact
Display
RS232 and dry contact(SNMP is optional)
LED indicators show status of AC input, inverter, low/high battery
Dimension (W×D×H)
440×300×1U
440×300×1U
440×350×1U
Weight(kg)
4
5
5
UPS 440×350×1U Charger+PDU&MBS: 440×350×2U 9
10
UPS 440×350×3U Charger+PDU& MBS: 440×350×2U
13
◆ Specification is subject to change without prior notice. 31
KTS dual input redundant static switch KTS010: as below
●
Dual input route design, Dual AC input are completely isolated;
●
Synchronization;
●
Flexible control panel location (Front or Rear);
●
It ensures the high MTBF and the system reliability of Inverter system or UPS system
Specification: Item
KTS010
KTS032
Input voltage(Vac)
KTS032: as below:
110/220±25%
Input frequency(Hz)
50/60Hz±6Hz
Rated output capacity 110V
1KVA/0.7KW
3KVA/2.1KW
Rated output capacity 220V
2KVA/1.4KW
6KVA/4.2Kw
Overload
125%, not limited; 150%≥60S
Output voltage(Vac)
110/220±25%
Transfer time (mS)
≤8
Dimension(mm)(W×D×H)
≤10 440×286×1U
Weight(kg)
4
◆ Specification is subject to change without prior notice.
MMBM-3 Intelligent battery monitoring system ● Perfect protection&Alarm detection function ● With LAN, RS232 & RS485 communication port ● Module design. ● Perfect management analysis
Specification: Item System composition
2V battery system Monitoring module MCU-3+ Sampling module BM02-3
Voltage detection accuracy Voltage detection range
≤±0.2% 1.5~3.0 V
Current detection accuracy
0~±1000 A
Internal resistance detection accuracy
±(2.5%+25 μΩ )
Internal resistance detection range
0.1mΩ~100 mΩ Large screen, backlit LCD display, up to 320 × 240 lattice, the viewable area 118 x 88mm
Temperature detection accuracy Cell monitoring
±0.5℃ Each monitor can monitor total max. 240 cells.For 2V system, each sampling module can collect total 27 cells battery information;For 12V system, each sampling module can collect total 24 cells battery information;
Communication port
LAN、RS232、RS485
Input insulation resistance Communication protocol
500M 1000VDC CDT, POLLING or MODBUS(only one of them can be chosen)
Working power
AC/DC220V±15%(standard)
Nominal ambient temperature
32
9~16 V ≤±1.0%
Current detection range
Operation mode
12V battery system Monitoring module MCU-3+ Sampling module BM12-3
-10 ℃ ~ +55 ℃
Ambient humidity
40% ~ 70% Relative humidity
Dimension/Weight
Sampling module :BM02-3: 420×200×43(mm); (for 2V battery) / ( 2.3kg);BM12-3: 483×200×44(mm); (for12V battery) / ( 2.5kg); Monitoring module : MCU-3: 322×140×48(mm) / (2 kg)
◆ Specification is subject to change without prior notice.
Option
Other products
●
UPSilon 2000 software
●
Solar system
●
SNMP adapter
●
Integrated Data Center (IDC)
●
MODBUS
●
Wind turbine
●
Dry contact
●
Hybrid street light
●
MMBM-3 Intelligent Battery Monitor System
●
Power distribution cabinet
●
Extendable charger board
●
Reverse energy absorber
●
External battery bank
●
Lightning arrester
●
12 pulses rectifier
●
ATS
●
Parallel
●
Charger
●
Remote monitor
●
Battery
English book 20131010/01
2000
Xiamen Kehua Hengsheng Co., Ltd. Zhangzhou Kehua Technology Co., Ltd.
ADD: Beidou Industrial Zone, Jingfeng Industrial District, Zhangzhou, Fujian, China P.C.: 363000 Tel:
0086-596-2673217
Fax: 0086-596-2895827 E-mail:
[email protected]/
[email protected] www.kehua.com