UPS systems
YEARS
Delivery
YEARS
5 5
UPSI-2404
Fanless Delivery
Fanless
Operation
Operation Extended
Extended
24 V DC / 6 A
Continuous battery monitoring Battery capacitance display Battery lifetime display USB communication interface
The UPSI-2404 protects connected consumer loads from supply voltage fluctuations and interruptions. The μC controlled DC UPS has a continuous battery monitoring which ensures that sufficient capacitance remains in the battery to guarantee the supply of consumer loads in case of power failure. Additionally the UPSI2404 offers a load sensor and a timer function.
Te c h n i c a l d a t a Input voltage Input current Output voltage Output current Battery charge current Charging method Protection Transfer time / limits Interface Type of battery Safety / EMC Temperature Humidity Dimensions (Wx D x H) Weight (net)
3-colour-LED for „Power ok” (green), „Power Fail” (orange), „Battery low” (red/orange flashing) and „Battery defect” (red/green flashing), short circuit at output/overload (red) Battery test is carried out in normal mode approx every 10 minutes, in case of “Battery defect“ notification the LED flashes red/green App. 80 mA Via UPS Software „UPSI Control Center“ During system start-up the shutdown signal is suppressed for app. 2 minutes. If power fails and then returns during the shutdown mode of Windows®, the reboot function restarts the system after about 10 seconds. Via UPS software „UPSI Control Center“ adjustable (0…20 W). When falling below the set load the UPS switches off after 5 seconds. Via UPS software „UPSI Control Center“ adjustable in 2 minutes-steps from 2…20 Min. (in battery mode) App. 1.5 h at 1 A / app. 25 min at 3 A / app. 15 min at 5 A (measured at +20 °C with BP-1225-B1) „UPSI Control Center“ (Windows® 7 or higher) to download at www.bicker.de (XP on request) Bicker Elektronik GmbH | 86609 Donauwörth | Deutschland Tel. +49 906 70595-0 |
[email protected] | www.bicker.de
DC UPS
Product specific data LED display Battery monitoring Power consumption Shutdown detection Shutdown-suppression Reboot-Funktion Load sensor Timerfunktion Back up time UPS software
24 V DC (22.5…28 V) 6.7 A max. In normal mode: app. 0.5 V below input voltage In battery mode: app. 29…19 V DC 6 A max. 0.65 A max. (internal battery charger) UI characteristic, with temperature regulation Deep discharge protection: 19 V DC ±2 % Overload protection at output: 9 A for 2 seconds, switch off Short-circuit protection: Switch off via µC Mains / battery 20.5 V DC ±2 %, battery / mains 22 V DC ±2 % USB (Standard B), internal USB Cyclon/Hawker / lead-fleece CE Operating: -20…+70 °C / Storage: -40…+70 °C Operating: 10…85 % RH, non-condensing / Storage: 10…90 % RH, non-condensing 119 x 114 x 24 ±0.5 mm 0.25 kg
UPS systems Drawing UPSI-2404 119,0 mm 4,0 mm
4 mm
5,8 mm
24 mm
2,5 mm
4,0 mm AK2+
1 2 3 4 5
AK2-
F2
USB
SV1 Power Connector
5,8 mm
F3
104,3 mm
5,8 mm 104,3 mm
114,0 mm
AK1-
AK1+
4,0 mm
7,5 mm
109,2 mm
109,2 mm
5,8 mm
4,0 mm
Tolerance ±0.5 mm
Connection
5 IN
4 3 2 1
OUTOUT IN
USB F2 10 A
USB
F3 10 A
AK1+ AK1- AK2- AK2+
GND IN+
AKKUNTC
BATT1 10 A BATT2 10 A
BP-1225 (not included in delivery)
+
BATT1 -
TEMP BATT NTC 10k
UPSI | Control Center The UPS software is available for download at www.bicker.de. In addtion to the current operating parameters, the software informs about the expected „battery lifetime“, too. To display the correct battery capacitance, please choose the correct type of battery in the software. Only batteries of the optional accessory are supported.
+
BATT2 -
DC connector 1 1 output (+) 2 output (–) 3 input (–) 4 input (+) 5 FG
Temperature sensor for battery charging included in delivery. Length: 500 mm
Optional accessory For detailed information please visit our website www.bicker.de and refer to the article number. Article No. Description CB-USB01 USB cable 2.0 / A/B connector / 500 mm BP-1225 Battery pack with CYCLON cells, 12 V / 2.5 Ah, -30…+70 °C (2 pieces necessary) LC-R121R3PG Battery for UPSI-2402 and UPSI-2404, 12 V / 1.3 Ah, 0…+40 °C (2 pieces necessary) LC-R122R2PG Battery for UPSI-2402 and UPSI-2404, 12 V / 2.2 Ah, 0…+40 °C (2 pieces necessary) LC-R127R2PG1 Battery for UPSI-2402 and UPSI-2404, 12 V / 7.2 Ah, 0…+40 °C (2 pieces necessary) Bicker Elektronik GmbH | 86609 Donauwörth | Deutschland Tel. +49 906 70595-0 |
[email protected] | www.bicker.de
DC UPS
Specification is subject to change without notice. Errors excepted. Windows® is a trademark of Microsoft Inc. Status as at: 23.12.2015
DC-Connector 1
IN+ IN-