Preview only show first 10 pages with watermark. For full document please download

Uputstvo Za Ugradnju Motora Za Kliznu Kapiju Achilles 4000

   EMBED


Share

Transcript

Istruzioni, instructions, instrucciones Attention! • This user guide is addressed exclusively to technical personnel, qualified in the installation area and not to the final user, i.e. the installer is fully responsible for informing user about all the instructions for the proper use of the device, potential hazards which can occur afterwards as well as the necessity of the periodical maintenance. • The process of installation must be executed exclusively by qualified personnel, fully observing instructions concerning automatic gates, particularly compliance with the 89/392 directive and EN 12453 - EN 12445 standards. • ACHILLES was conceived as device of the sliding gate automation management, thus it is strictly forbidden to use the product in an improper way or for any other use not complying with the goals set by the producer. • Only use of the original components is authorized. Stagnoli excludes any responsibility for the damage caused by the use of not original components. • Please ensure that the structure of the gate is reliable and adaptable to be motorized. • Please ensure that the gate, while moving, is not subjected to friction at any point and there is no possibility to derail the gate. • Please ensure, before any action is taken at the gate, that the power supply is cut off. • Connect tension cable exclusively to the voltage lines equipped with the proper electric protections; particularly, the gate must be provided with a device allowing complete disconnection from the power and having a distance between contacts of at least 3.5 mm. • Evaluate with particular attention safety devices and the places they should be installed; furthermore, always ensure an emergency stop device allowing obligatory disconnection from the power. • All maintenance operations, particularly the access to the internal parts of the gear motor must be executed exclusively by the qualified personnel. • Non reversibility of the gear motor avoids the installation of any electrical locks, in 8 Istruzioni, instructions, instrucciones case any black-out occurs, the manual release allows manual opening and closing of the gate. Technical specification The ACHILLES 4000 gear motor by Stagnoli, is adapted for the automation of sliding gates up to 4000 kg of weight. Following table presents technical specification of the various models: Technical data Power supply ACHILLES-4000 ACHILLES-4000 230Vac 400Vac 230V~ / 50 Hz 400V~ / 50 Hz 6.4 3.75 Motor supply 230V~ 400V~ three-phase Engine power (W) 1500 W 1500 W N° engine revolutions (rpm) 1400 1400 Reduction ratio 1/30 1/30 11 m/min 11 m/min Working temperatures (°C) -20° < > +60° -20° < > +60° Working cycle (%) intensive (50) intensive (50) 44 44 Max. thrust force 3200 N 3200 N Max. gate weight 4000 kg 4000 kg 59 59 Power absorption (A) Min. speed with full load Level of IP protection Weight (Kg) 9 Istruzioni, instructions, instrucciones Dimensions and height 327 Before starting installation process, please check the gear motor placement area in relation to its heights and dimensions (fig.1). 111 605 570 400 392 Fig.1 Fixing of the foundation plate Unscrew four lateral screws in order to remove the cover of Achilles 4000 (fig.2). Before fixing Achilles 4000 body, prearrange one or more sheathing to allow shifting of cables. After having checked optimal conditions for the body placement position on the six clamps and insert it in the concrete (fig.3). Fig. 2 10 Istruzioni, instructions, instrucciones Fig.3 Installation of the gear motor Fix the gear motor on the flange slots to the body of the foundation (fig.4). Before locking completely four nuts, please adjust the distance from the gate. Take the first section of the rack and position it above the gear, ensure a space of at least 1 mm between the gear itself and the rack, than fix it to the gate with screws. Control the correct positioning by sliding door manually (fig.5). Fig.4 1mm Fig. 5 Continue fixing process of the remaining rack with respect of the gap between one joint and another (fig.6). Position limit brackets on the rack and adjust position of the brackets by sliding the door in relation of the desired opening and closing, 11 Istruzioni, instructions, instrucciones afterwards fix the brackets definitely Fig.6 Manual release In order to execute any manual manoeuvre proceed as follows (fig.7): 1. Rotate the key clockwise. 2. Lift the door. 3. Using the hexagonal key, size 22, unscrew the nut positioned at the edge of the cylinder, till it is not easily taken out from its seating inside the body of the gear motor. 2 1 Fig.7 Adjustment of the mechanical friction (exclusively for the model with friction SA41000000 – SA412304041) + In order to adjust the mechanical friction use an allen spanner, size 6, for cylinder head screws with the hexagonal cavity situated in the superior part of the motor (fig.8). Loading: Screw the screws. Release: Unscrew the screws. Fig.8 12