Preview only show first 10 pages with watermark. For full document please download

Usc Spec Sheet Vsu1-002.qxd - Universal Switching Corporation

   EMBED


Share

Transcript

Specification Sheet VSU1-002 CE Low Cost - High Performance 1RU 6x1 RBGS Video Router Model VSU1-4P6T September 2006 General This commercial video router product provides a unique multi-pole switching function while maintaining an uncompromising combination of high performance, small size and low cost. The VSU1-4P6T video router has a six input, one output switching configuration, but with four “poles” being switched together at the same time (ganged). These four poles can be used for switching RGB&S type video signals, or other types of signals that need to be switched as a group. Applications Compact and high performance, the VSU1-4P6T provides a cost effective, flexible switching capacity for smaller installations providing choices of two different control configurations (serial only, or serial and Ethernet). „ „ „ „ „ „ „ „ „ „ „ „ „ „ „ „ „ „ Features Complete control and status of the unit is available at both the front panel controls or remote interface(s). The front panel includes LED illuminated push-buttons (to control and status the unit), an LED illuminated super-twist LCD display, plus bi-color status LED’s. At the rear are BNC connectors, the user configurable serial port (RS-232C/422A/485), optional Ethernet port (10baseT), plus the universal AC power input and AC switch. Digital broadcast facilities or production studios Airborne surveillance systems Communication installations Imaging and animation production facilities NTSC, PAL, DS3, DVB or RGBS routing Security systems Factory automation monitoring High reliability solid-state switching >130MHz analog bandwidth High signal level capacity switching (~10V p/p) BNC signal connectors (75 ohm) Extra set of isolated output ports available Automatic “ganged” control for 4-levels Super-twist LED illuminated LCD display Field configurable serial port (RS-232C/422A/485) Optional Ethernet port (10baseT) with TCP/IP International AC power input, or optional DC Certified CE EN61010 (LVD) Configurations „ „ Model VSU1-4P6T VSU1-4P6T-E10 Configuration 6 input, 1 output 6 input, 1 output Conn BNC BNC Control Serial (note 1) Serial/Ethernet NOTE 1: The units are delivered “jumper configured” for RS-232C. The user must remove the cover and change configuration jumpers to configure the serial port for RS-422 or RS-485 protocol. NOTE 2: Simplified functional scematic shown below. There is an “off” position not shown, and the signal path is active (terminations, switch element and amplifiers not show). IN 01 J1 J2 J3 J4 J25 PO LE 1 O UTPUT J27 PO LE 2 O UTPUT J29 PO LE 3 O UTPUT J31 PO LE 4 O UTPUT J5 IN 06 J6 IN 01 J7 J8 Model VSU1-4P6T Six input, 1 output (4 pole - RGBS) J9 J10 J11 VSU IN 06 J12 IN 01 J13 J14 J15 J16 J17 IN 06 J18 IN 01 J19 J20 J21 J22 J23 IN 06 J24 G 01307 G2R04-001 7671 North San Fernando Road | Burbank CA 91505 USA Phn: +1 818-381-5111 Fax: +1 818-252-4846 Email: [email protected] Page 1 Web: uswi.com Command Protocol Serial Pin Assignment The control command protocol for the unit is simple and streamlined, yet powerful and comprehensive for a switch of its size. All commands are standard ASCII strings, and must be terminated with a . The “x”s below represent digits specific to the command. The following commands are available: Cxxxxxx Dxxxxxx Vxxxxxx STxxx RExxx clear DLOAD RESET VER MON MOF Ixx LCK UNL BPx RON ROF Axx RS-232C Version Pin Function 1 . . . . . .Not Used 2 . . . . . .Transmit Data 3 . . . . . .Receive Data 4 . . . . . .Not Used 5 . . . . . .Signal Ground 6 . . . . . .Not Used 7 . . . . . .Clear To Send 8 . . . . . .Ready To Send 9 . . . . . .Not Used Connect a source port to a destination port Disconnect source port from destination port Verify the status of connection Store switching configuration Recall switching configuration Clear all connections Download switch configuration Reset the system to factory default (clear all configuration data) Request for firmware version Enables Serial port output of commands from other ports Disables monitoring of commands from other ports Sets the baud rate of the serial communications port Locks the front panel controls Unlocks the front panel controls Controls conditions for internal beeper usage Enables the system "Auto Restore" mode Disables the system "Auto Restore" mode Changes the RS-485 address HIGH CONTRASTLED ILLUM INATED ALPHA NUM ERIC 2X20 INFORM ATION DISPLAY Pin Function 1 . . . . . .Transmit Data (-) 2 . . . . . .Transmit Data (+) 3 . . . . . .Receive Data (+) 4 . . . . . .Receive Data (-) 5 . . . . . .Signal Ground 6 . . . . . .Clear To Send (-) 7 . . . . . .Clear To Send (+) 8 . . . . . .Ready To Send (+) 9 . . . . . .Ready To Send (-) BI-COLOR STATUSLED'S STANDARD RACK M OUNTSLOTS FRONT Analog Video Router VSU1-3208 2 STATUS 3 COM M ERRO R BA TTERY US WD 4 5 6 RESET SOURCE SYSTEM RESETSW ITCH (RECESSED) USLINK CONTROL PORT FEM ALE BNC CONNECTORS (75 OHM ) ETHERNETPORT(10baseT) (OPTIONAL) REAR J1 J3 J5 J4 J7 J6 J9 J8 J11 J10 J13 J12 J15 J14 J17 J16 J19 J18 J21 J20 J23 J22 J25 J24 J27 J26 J29 J28 USlink J31 J30 J32 J3A RS232 RS422 RS485 CE Seri es VSU GND CTS RTS M AIN AC POW ER SW ITCH ROCKER TYPE Designation TXD TXD + RXD + RXD GND CTS CTS + RTS + RTS - RS-485 Multidrop Version Pin Function 1 . . . . . .TR Data (-) 2 . . . . . .TR Data (+) 3 . . . . . .Not Used 4 . . . . . .Not Used 5 . . . . . .Signal Ground 6 . . . . . .Not Used 7 . . . . . .Not Used 8 . . . . . .Not Used 9 . . . . . .Not Used Designation 485 485 + GND 10BaseT Use only with a 250V fuse J2 TXD RXD RS-422A Version LED ILLUM INATED CONTROLPUSH-BUTTONS 1 Designation 1 0 M ade in the USA AC POW ER INPUT ~90-264VAC,47-440Hz,15W M AX NOTE: The Ethernet versions use a different control protocol from shown above. Contact the factory for additional information. SERIALCONTROL/STATUSPORT W ITH RS-232C/422A/485 (DE-9S) VSU1 Specifications Array size . . . . . . . . . . . . . . . . . .Quad channel (ganged) 6x1 Switching technology . . . . . . .High reliability solid-state Type of system . . . . . . . . . . . . . .Nx1 Architecture . . . . . . . . . . . . . . . .Fixed size array Signal connector location . . . .Rear panel Frequency response . . . . . . . . .DC-130MHz (-3dB) DC-100MHz (-1dB) Crosstalk isolation . . . . . . . . . . .>75dB @ 5MHz Gain . . . . . . . . . . . . . . . . . . . . . .Unity (nominal) Input Characteristics Type . . . . . . . . . . . . . . . . . . . . . .Single-ended Signal connector . . . . . . . . . . .BNC female (75 ohm type) Coupling . . . . . . . . . . . . . . . . . .DC Impedance . . . . . . . . . . . . . . . .75 ohm Return loss . . . . . . . . . . . . . . . . ..20dB Nominal signal level . . . . . . . . .+4VDC Maximum input level . . . . . . . .+5.5VDC (no damage) Output Characteristics Type . . . . . . . . . . . . . . . . . . . . . .Single-ended Signal connector . . . . . . . . . . .BNC female (75 ohm type) Coupling . . . . . . . . . . . . . . . . . .DC Impedance . . . . . . . . . . . . . . . .75 ohm Maximum output level . . . . . . .+4.5VDC (into 75 ohm load) DC offset . . . . . . . . . . . . . . . . . .<50mV Page 2 General Specifications Switching . . . . . . . . . . . . . . . . . .Asynchronous Power supply section . . . . . . . .Universal type (non-redundant) Power supply monitoring . . . . .Included Remote control interfaces . . . .Serial (RS-232C, RS-422A or RS-485 multi-drop) Serial port connector . . . . . . . .DE-9S (D-Type female) US-Link connector . . . . . . . . . . .RJ-45 Ethernet (optional) . . . . . . . . . .RJ-45 Status LED’s . . . . . . . . . . . . . . . .Bi-Color on front panel Front panel display . . . . . . . . . .2x20 LED illuminated super-twist LCD Configuration memory . . . . . . .Lithium-back RAM Memory retention . . . . . . . . . . .>10 years Cooling . . . . . . . . . . . . . . . . . . . .Convection AC power requirements . . . . . .90-264VAC, 47-440Hz, 15Watts (max) Power cord . . . . . . . . . . . . . . . .6-foot (Belden 17250) Fuse protection . . . . . . . . . . . . .2A, 5mm (dual), AC models only Weight . . . . . . . . . . . . . . . . . . . .7 lbs Size . . . . . . . . . . . . . . . . . . . . . . .1.75H x 9.55D x 19.00W (1RU) Operating temp . . . . . . . . . . . .0 to +60C Non-operating temp . . . . . . . .-20 to +85C Humidity . . . . . . . . . . . . . . . . . . .0 to 95% (NC @ +25C) MTBF . . . . . . . . . . . . . . . . . . . . . .>170,000 hours Certifications . . . . . . . . . . . . . . .CE EN61010 Universal Switching’s policy is one of continuous development. Consequently, the company reserves the right to vary from the descriptions and specifications shown in this publication. 7671 North San Fernando Road | Burbank CA 91505 USA Phn: +1 818-381-5111 Fax: +1 818-252-4846 Email: [email protected] Web: uswi.com