Preview only show first 10 pages with watermark. For full document please download

User Guide - Onvcom.com

   EMBED


Share

Transcript

USER GUIDE PoE & Optical Transmission Fiber Optical Transceiver Statement Copyright @ 2002-2013 Optical Network Video Technologies (Shenzhen) Co., Ltd All Rights Reserved This document contains proprietary information that is protected by copyright. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise without the prior written permission of Optical Network Video Technologies (Shenzhen) Co., Ltd. ® is the registered trademark of Optical Network Video Technologies (Shenzhen) Co., Ltd. The information and product specifications within this document are subject to change at any time, without notice and without obligation to notify any person of such change. Packing List Please kindly check the following items: 1 Pair/piece fiber optic transceivers 1 Piece power adapter 1 Set other accessories 1 User Guide/Conformity Certificate/Warranty Card ! Note If any shortage or damage found, please contact us in time. Product overview Product Introduction Fiber optic transceiver is the most suitable connector for the intelligence community broadband Ethernet or fiber to the desktop, widely used for expanding the network transmission distance. The series fiber optical transceivers comply with IEEE 802.3, IEEE 802.3u, IEEE 802.3ab / z standard, network transmission distance limit can be extended from the twisted pair 100M to 100KM and more, you can easily realize seamless co nnection between servers, repeaters, hubs and terminal, it can meet the needs of long-distance, high-speed, high-bandwidth Fast Ethernet workgroup users.Fiber optic transceivers can not only extend the transmission distance, but also with good isolation protection and data privacy, stable working, maintain easily, and many other advantages, it can effectively avoid lightning, surging and electromagnetic interference threaten for communications equipment in harsh environments. Feature Standard: comply with IEEE802.3 10Base-T、100Base-T、1000Base-F Fiber signal: RX、TX Ethernet port: 10/100Mbps rate auto-adaption、10/100/1000Mbps rate auto-adaption Fiber port: 155Mbps、1.25Gbps Working mode:Asynchronous working,P2P,Support full/half-duplex auto-adaption Ethernet port transmission distance:100m Fiber port transmission distance:2Km(Multi-mode),25/40/60/100Km(Single mode) Cable:UTP 5E type Fiber:Multi-mode fiber:50/125、62.5/125μm,Single-mode fiber: 8.3/125、8.7/125、9/125 or 10/125μm Fiber wave length:1310nm(2Km、25Km、40Km),1550nm(25Km、40Km、100Km),1310nm(MM2Km) Ethernet port:RJ45 Fiber port:SC、ST、FC or LC Technical Structure and Port Description r te e r t e r v e RX C TM X r rt e e v E R n T o C X V E R -F e O N s a C B 0 0 E R 1 IB & F X IT -T e a B s A B B.155M Up Link Fiber Four port 100M Fiber Media Converter (External Power Supply) e o n 2 3 4 1 2 3 4 5 6 7 8 ib e a ti n g F r C v e rt r E R T E R N V O C Eight port 100M Fiber Media Converter (External Power Supply) 28mm s ti H h ig RJ45 6 11 .00 mm Link Link PWR PWR FIBER 118mm 1 1 2 3 2 3 4 5 6 7 8 4 PWR FIBER POWER POWER C.DC5V Input FIBER 189mm SM A. Single Fiber/Dual Fiber Multi-mode Fiber B.Single Fiber/Dual Fiber single-mode Fiber mm A. 10/100/1000M Down Link Rj45 Port B.1.25G Up Link Fiber C.DC5V Input 25mm R D IA R E E T R E M RX .00 u I V M N O T RX TX 6 11 102mm 1 d C a n U L IA I D D E M SPL D M I F & LT M U M A T L & G LE rn e t G e IN th S IN E TX E S POW POW mm PWR A.Two 10/100M Down Link Rj45 Ports C.AC110-245V Input 0 1.0 FDX 12 89mm RX 0 G IG Fiber PWR NODE/HUB Link Tx2 FRX B.155M Up Link Fiber C.DC5V Input Tx1 TRX 9 Auto MDI/MDI-X mm SPD FDX PWR 0 4.0 Single Fiber/Dual Fiber(Single Mode/ MultiMode) Converter MM 0 /1 0 1 RX 100 A.10/100M Down Link Rj45 Port TX r F - e e s iv a B e 0 c 0 s 1 n & a X r T - T e s T a / B r 0 e 0 /1 ib 0 1 F TX FX TX L/A Fiber o n v n o C X TM F - r e s e a B iv 0 e 0 c 1 s & n X a T r - T e s a T / B r 0 e 0 /1 ib 0 F 1 SDP FDX TX Single port 1000M Fiber Media Converter (External Power Supply) Two port 100M Fiber Media Converter (Internal Power Supply) r Single port 100M Fiber Media Converter (External Power Supply) A.Four 10/100M Down Link Rj45 Ports B.155M Up Link Fiber C.DC5V Input A.Eight 10/100M Down Link Rj45 Ports B.155M Up Link Fiber C.DC5V Input FIBER Indicator description: Indicator PWR SPD Power On, normal Supply Long off Power off or power fault steady green normal working status Long off 100M optical transceiver: work under 10M mode; 1000M optical transceiver work under 10/100M mode steady green FX TX Link ! Description Status steady green Flashing green correct fiber connection fiber interface is transmitting or receiving data Long off wrong fiber connection steady green correct electrical interface connection electrical interface is transmitting or receiving data Flashing green Long off wrong electrical interface connection steady green Flashing green connect to 10/100/1000M network device fiber interface is transmitting or receiving data Long off no network device connected Note Notes: Equipment is with precision instrument built in, please take it gently to avoid severe vibration, so as not to affect the device performance. If you find that the device is damaged or any part is lost during transport, please notify the Company or the Company's distributor, we will properly solve this problem for you. Indicator: Indicating the working status of power, network connection, fiber interface and electrical interface. This can help engineers to check the working status of system and network, and then analyze field problems and facilitate monitoring. Power jack: connected to the power adapter. Please use 48V power, otherwise the POE switch can be damaged. Built-in 100M POE switch will need no power adapter, you can use it just by connecting to AC110V-24V/50Hz power. Ethernet interface: Auto adapt RJ45 port, all RJ45 port support auto flip, plug-and-play. You can also check the working status by seeing the indicators. PC am er IP Ca me IP a ra /T Fi Co ber nv er te CP r s A BI T R /T ET H TR ER A N N ET SC M 00 EI 0B V ED IA A ER SE CO -T 10 N V 00 ER BA TE SE R -S X G ig bi t 10 r Fib er /1 A BI T R /T ET H TR ER A N N ET SC M 00 EI 0B V ED IA A ER SE CO -T 10 N V 00 ER BA TE SE R -S X G ig bi t IG Fi Co ber nv er te IN 00 L BE G /1 A BI T R /T ET H TR ER A N N ET SC M 00 EI 0B V ED IA A ER SE CO -T 10 N V 00 ER BA TE SE R -S X G ig bi t IG 00 BE G FI /1 /1 A BI T R /T ET H TR ER A N N ET SC M 00 EI 0B V ED IA A ER SE CO -T 10 N V 00 ER BA TE SE R -S X G ig bi t IG 00 BE G FI /1 IP FI 10 10 NV /1 er /1 CP IG Fib BE /T r 00 /1 A BI T R /T ET H TR ER A N N ET SC M 00 EI 0B V ED IA A ER SE CO -T 10 N V 00 ER BA TE SE R -S X G ig bi t IG 00 BE G r FI Fi Co ber nv er te /1 /1 A BI T R /T ET H TR ER A N N ET SC M 00 EI 0B V ED IA A ER SE CO -T 10 N V 00 ER BA TE SE R -S X G ig bi t IG er G IP 10 CP 00 Fib Fi Co ber nv er te FI les /T r /1 i re BE G Fi Co ber nv er te IP 10 W r /1 Fi Co ber nv er te FI IP 10 Connection Diagram R /T CP /T CP UP K W id eA re aN et wo rk Installation guide Please make sure to use this products based on the following regulation, in order to avoid any damage to human body or to other connected products. Installation Before installation, please make sure: 1.Note the value range and the related mark on the product and the User Guide; 2.Make sure the power adapter specification matches with the product label Installation Steps: 1.Connect optical fiber patch code with Media Converter fiber port. Note fiber TX on one end should be connected to RX on the other end to Media Converter. 2.UTP wire to RJ45 port of the Media Converter. 100Base-TX requires 2 twisted pairs (1/2; 3/6), while 1000 Base-T requires 4 twisted pairs, and it must be Super Category 5 twisted pair or Super Category 6 twisted pair. 3.Connect the power adapted DC plug with Media Converter DC plug, and then insert the AC power adapter plug to AC socket, turn on the power, now the Media Converter POWER indictor is ON, the other indictors will be ON successively with the self-inspection turn. The RJ45 port will detect the connected device status to decide itself working status, if no devices are detected; Media Converter RJ45 port will be set up to be Full-duplex, which will be displayed with the LED indictor. ! Note 1 Don’t put heavy thing on the product to keep good heat dissipation status 2 Turn off the power before plugging the power 3 Don’t look straight at the fiber ports when Media Converter is powered, in case any damage to eyes. Please refer to the above solution with any problems of installation and using, or get in to touch with our technicians. Model description with details fault phenomenon detection elimination methods After making contact, twisted pair were connected, the electric port indicator “OFF” To transform the DIP switch gear or restart power source. Fiber indicator “OFF” or replacing fiber connector still “OFF” Detecting optical power of receiver, it should not lower than -36 dBM. Otherwise replacing longer distance equipment. Fiber dynamic indicator “Blink” or “OFF”, data transmission cannot be connected 1、Port optical transmit power is not enough or attenuation is too large. 2、Luminous sensitivity is not enough on receiver port. 3、Checking fiber connection loss. Both of end equipment link is faulty. Connected analog terminal by twisted-pair cable cross -connection Testing both of end equipment whether is normal. PING , packet loss happened Checking whether the twisted pair is in accordance with standard. Appendix: 2U rack can supports inserted 16 fiber optic transceiver modules, each module can be used independently with modular power supply design, dual power backup, easy maintenance, good shielding, it can effectively prevent electromagnetic interference for power supply module running. (Please visit the official website) Tel:+86-755-33376606 Fax:+86-755-33376608 Email:[email protected] Address: Room 1003, Block D , Tairan building , Chegongmiao, Futian district ,Shenzhen ,China Factory address:No 5, A building, SenYuTai S&T park, Longhua road, BaoAn district,Shenzhen, China www.onvcom.com