USER INSTRUCTIONS FOR IMMEDIATE RESPONSE TECHNOLOGIES, INC. M96 CARTRIDGE PART NO. S-70020 NSN: 4240-01-574-9568 This cartridge shall only be used with NIOSH approved IMMEDIATE RESPONSE TECHNOLOGIES systems. The NIOSH approval label (see reverse) outlines the NIOSH-approved systems, and their components, that may be used with the M96 Cartridge. Complete maintenance of systems and operating instructions are detailed in your system’s user manual. The restrictions and limitations are outlined on the NIOSH approval label (see reverse) and must be followed strictly. Failure to do so may cause severe bodily injury or death.
Pre-Use Failure to change the cartridges when needed reduces the user’s protection, comfort, and may cause severe bodily injury or death. Make sure: 1)that the cartridge is appropriate for your application by checking with your Local Safety Program Administrator 2)verify that the packaging is intact and confirm the following: that the cartridge part number on the wrap-around label is S-70020, the word NIOSH is apparent, the expiration date date has not been passed 3)verify that the cartridge housing is not damaged. Using damaged Cartridges may cause contamination to enter the system and cause serious bodily injury or death; 4)verify that the filter seal for the Facepiece cartridge inlet or the rubber gasket for the Powered Air Blower Assembly cartridge port is in place and in good condition, and install/replace if necessary; 5)carefully thread the cartridge into the Facepiece or Powered Air Blower Assembly cartridge inlet until snug.
Storage This cartridge shall be used as soon as possible after opening. However, the M96 Cartridge has an extended storage life if stored unopened, out of direct sunlight and in a dry environment. Note the expiration date on the cartridge body.
S-Special Use Limitations Apply The IRT M96 Cartridge, when used with the C420 and FlexAir PAPR Systems, meets NIOSH approval for organic vapors, ammonia, acid gases (Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide and Sulfur Dioxide), Formaldehyde, Methylamine and as an HE Filter for powered air purifying respirator (PAPR). The M96 Cartridge, when used with the Promask 2000 full facepiece and the M95 full facecepiece, meets NIOSH approval for organic vapors, ammonia, acid gases (Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide and Sulfur Dioxide), Formaldehyde, Methylamine and as a P100 Filter for an air purifying respirator (APR). The C420 PAPR System, Promask 2000 facepiece, M95 facepiece (APRs) and M96 cartridge have been tested at canister levels for Tear Gas (CS & CN) and Phosphine and can therefore be used as a gas mask for Tear Gas and Phosphine only.
Disposal These cartridges MUST be disposed of in strict accordance with local, state and/or federal regulations.
Failure to comply and follow the Disposal, Storage, Use, Pre-use or Duration instructions as outlined in these instructions may cause serious bodily injury or DEATH to oneself or others.
Duration The cartridge’s duration is determined by the atmosphere and contaminant in which it is being used. Refer to your user’s manual for specific details outlining the method of use and your actions. However, the user: 1) must leave the contaminated area immediately if he/ she notices an increase in resistance or can detect (Taste or Smell) an odor. The person must then follow the system’s user manual’s instructions for cartridge changeout; 2)must change the cartridge if exposed to water.
Immediate Response Technologies, Inc. 7100 Holladay-Tyler Road Glenn Dale, MD 20769 800 598-9711
P/N C-85095-001, Rev. 9
This manual could contain technical inaccuracies or typographical errors. Updates are made periodically to the information herein. If you have comments please forward them to Immediate Response Technologies, Inc. Thank you.
IMMEDIATE RESPONSE TECHNOLOGIES, INC. 7100 HOLLADAY-TYLER ROAD GLENN DALE, MD 20769 (800) 598-9711
Immediate Response Technologies IRT M96 CARTRIDGE This Cartridge is approved only in the following configurations:
RESPIRATOR COM PONENTS
CAUTIONS AND PROT ECT ION1
TC-
LIMITATIONS
23C-2457
HE/AM/CD/CL/FM /HC/HF/HS X /MA/OV/PH/SD/CS/CN
X
X
X
84A-5036
P100/AM/CD/CL/FM/HC/HF/ HS/MA/OV/PH/SD/CS/CN
X
X
X
23C-2458
HE/AM/CD/CL/FM /HC/HF/HS /MA/OV/SD
84A-5175
P100/AM/CD/CL/FM/HC/HF/ HS/MA/OV/PH/SD/CS/CN
23C-2484
HE/AM/CD/CL/FM /HC/HF/HS /MA/OV/SD
23C-2486
HE/AM/CD/CL/FM /HC/HF/HS /MA/OV/PH/SD/CS/CN
23C-2497
HE/AM/CD/CL/FM /HC/HF/HS /MA/OV/SD
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
ABCHJLMNOPSLL
X
X
OV - Organic Vapor
CL - Chlorine PH - Phosphine
FM - Formaldehyde SD - Sulfur Dioxide
HC - Hydrogen Chloride
HF - Hydrogen Fluoride
cs - Chlorobenzylidene Malononitrile
2. Cautions and Limitations A- Not for use in atmospheres containing less than 19.5% oxygen B- Not for use in atmospheres immediately dangerous to life or health. C- Do not exceed maximum use concentrations established by regulatory standards F- Do not use respirator if airflow is less than 115 lpm ( 4CFM) for tight fitting facepieces or 170 lpm (6CFM) for hoods and/or helmet. H- Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. I- Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J- Failure to properly use and maintain this product could result in injury or death. L- Follow the manufacturer's User's Instructions for changing cartridges, canisters and/or filters. M-All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA and other applicable regulations. N- Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O- Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P- NIOSH does not evaluate respirators for use as surgical masks. S- Special or critical User's Instructions and/or specific use limitations apply. Refer to User's Instructions before donning. LL- This respirator contains filter or cartridge components that are not approved for all protections in all configurations. Check the specific row on the NIOSH approval label to ensure proper use.
© 01/10 by Immediate Response Technologies, Glenn Dale, Maryland. All rights reserved.
ABCHJLMNOPSLL
X
X
ABCFHIJLMNOPLL
X
ABCFHIJLMNOPSLL
X
X
P100 - Particulate Filter (99.97% filter efficiency level) effective against all particulate aerosols CD - Chlorine Dioxide
ABCFHIJLMNOPLL
X
HE - High Efficiency Particulate Air Filter For Powered, Air-purifying Respirators
MA - Methylamine
ABCFHIJLMNOPSLL
X
1. Protection
AM - Ammonia
2
HS - Hydrogen Sulfide
CN - Chloroacetophenone
X
ABCFHIJLMNOPLL