Preview only show first 10 pages with watermark. For full document please download

User Manual

   EMBED


Share

Transcript

Desktop 1D Image Barcode Scanner User Manual Please read it carefully before using and take good care of it in order for checking in the future. V:1509 7 1 2 1 2 4 0 0 0 1 CONTENT Technical Parameters Warning Prompt Sound Reading Skills Caution Connecting the Barcode Scanner Interface Mode Configuration Code On/Off Default Configuration User Configuration Scanning Mode Normal Mode Screen Reading Mode Auto Sleeping Suffix Buzzer Setting Volume Control Turn on Prompt Sound-On/Off Good Read Prompt Sound-On/Off Good Read Prompt Sound-Tone Good Read Prompt Sound-Duration Error Warning Sound-Tone LED Indicator light Repetitive Bar Codes Test Choose Bar Code Type Codabar Codabar Start/Stop CHARS Code 39 Code 39 Check Digit Code 32 (Need Code 39 on) Interleaved 2 of 5 (14 digits) Interleaved 2 of 5 Check Digit Industrial 2 of 5 Matrix 2 of 5 Code 93 Code 128 GS1-128 UPC-A UPC-A Check Digit UPC-E UPC-E Check Digit EAN/JAN-8 EAN/JAN-13 UPC/EAN/JAN Supplement EAN13 Convert into ISBN EAN13 Convert into ISSN GS1 DataBar(RSS14) GS1 DataBar Limited GS1 DataBar Expanded 1 1 2 2 2 2 2 3 3 3 3 3 3 4 5 5 5 5 5 6 6 6 6 7 7 7 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 11 11 11 11 Technical Parameters Reading Skills Physical Parameters If the bar code is in small size, please make it closer to the scanner window. If the bar code is in big size, please make it farther to make a good read. If the bar code is with high reflectivity (e.g. coating film), it should be at a right angle of slope, then can read successfully. Material Size Power Supply Weight ABS+PC L*W*H 150mm*143mm*82mm DC 5V/2A 500±5g (without cable) Caution This barcode scanner has a bright light when it is working. To avoid discomfort and harm, please do not stare at it or aim at the eyes. Performance Parameters Support Interface USB, USB virtual serial port Sensor Planar CMOS sensor Connecting the Barcode Scanner Light Source White LED (lighting) Connect the barcode scanner to the incidental special connector, and then insert the USB port to the PC. Processor Decoding Capability Resolution Depth of Field 32-bit ARM MCU + DSP Codabar, Code39, Code32, InterLeaved 2 of 5 (14CHARS), Industrial 2 of 5, Matrix 2 of 5, Code93, Code128, Gs1-128, UPC-A, UPC-E, EAN/JAN-8, EAN/JAN-13, ISSN, GS1 DATABAR(RSS14), GS1 DATABAR Limited, Gs1databar Expanded Code39 3mil,PDF417 5mil,PCS45% 5MIL CODE39: 3--11 CM 13MIL UPC-A : 4--27 CM 20MIL CODE39 : 7.5--35 CM 6.7MIL PDF417 : 3.5--9 CM 10MIL DATAMATRIX: 3--10 CM 15MIL DATAMATRIX: 3--17 CM Interface Mode This barcode scanner supports USB keyboard mode and USB convert to RS232 mode. Scan the below bar code to set up the scanner as USB keyboard mode. This is the default mode. USB keyboard (default) Scan the below bar code to set up the scanner as USB convert to RS232 mode. (Need to install driver. Please contact our sales team.) Scanning Speed 500scans/sec Scanning Method Auto-sensing Scanning Area If the bar code configuration is off, please refer to ‘Configuration Code ON/OFF’ on page 2 and scan ‘ON’. 5 * 5 cm² -- 30 * 30 cm² Prompting Mode Buzzer, indicator light(LED) USB convert to RS232 Printing Contrast No lower than 35% Scanning Angle Roll 0-360°, pitch ±65°, yaw ±60° Configuration Code On/Off Environment Parameters IP Grade IP 54 Operating Temperature 0 to 50 ºC / 32 to 122 ºF Storage Temperature Operating Humidity ESD Protection Shock Resistance 0 to 50 ºC / 32 to 122 ºF When this function is on, all setup bar codes can be scanned to configure the scanner. When this function is off, all setup bar codes can’t be scanned to configure the scanner. Re-scan ‘ON’ then the scanner can read the setup bar codes and start settings. 5 - 95% (non-condensing ) 15kv air discharge 1m free fall on concrete surface ON (default) Warning Prompt Sound When the data transmission is abnormal, the scanner will have four continuous warning prompt sounds. If this situation should occur, please check whether the cable connection is correct. 1 OFF 2 Default Configuration Scan the below bar code to reset configuration to defaults. 1 minute Reset factory defaults 2 minutes User Configuration Scan the below code can save the current parameters as user configuration 5 minutes Save user configuration Scan the below bar code can reset the saved user configuration 10 minutes Reset user configuration 20 minutes Scanning Mode Normal Mode This mode is suitable for most of the scanning environment. Normal code (default) 30 minutes Suffix Screen Reading Mode When this mode is on, the scanner will read the bar codes on mobile phone screen or computer screen. Please note that this mode will probably lower the scanning speed of reading bar codes on paper. Cancel CR/LF suffix Screen reading mode Add CR suffix Auto Sleeping When the scanner has no bar code to be read, according to the settings the scanner can auto enter into sleeping mode in order to save power. When the scanner is in the sleeping condition, it won’t read bar codes until pressing the button on the top of the cover. The scanner is set to non-sleep as default. Add LF suffix Add CR+LF suffix (default) Non-sleep (default) 3 4 Buzzer Setting Good Read Prompt Sound-Duration Volume Control Long Low Short (default) High (default) Error Warning Sound-Tone When it fails to upload data, there will be four beeping sound. When it can’t identify the setup bar code, there will be one beeping sound. Turn on Prompt Sound-On/Off Off Low (default) On (default) Medium Good Read Prompt Sound-On/Off High Off LED Indicator light On (default) Good Read LED Indicator Light Off Good Read Prompt Sound-Tone Good Read LED Indicator Light On (default) Low Repetitive Bar Codes Test Medium High 5 This function is to configure the interval time of decoding the same bar codes. If it is within the limit time, all the same bar codes will be only decoded one time. Interval Time 300ms 6 Code 39 Interval Time 500ms (default) Code 39/On(default) Interval Time 750ms Code 39 /Off Code 39 Check Digit Interval Time 1s Code 39 Verify On, not transmit check digit Code 39 Verify Off (default) Interval Time 2s Code 39 Verify On, transmit check digit Choose Bar Code Type Code 32 (Need Code 39 on) All barcode type Off Code 32 On (default) Codabar Codabar On Code 32 Off Interleaved 2 of 5 (14 digits) Codabar Off (default) Interleaved 2 of 5/off Interleaved 2 of 5/on (default) Codabar Start/Stop CHARS Interleaved 2 of 5 Check Digit Not transmit Codabar start/stop CHARS(default) ITF 2 of 5 Verify on, not transmit check digit ITF 2 of 5 Verify off (default) Transmit Codabar start/stop CHARS ITF 2of 5 Verify on, transmit check digit 7 8 UPC-E Industrial 2 of 5 Interleaved 2 of 5/off Interleaved 2 of 5/on (default) Matrix 2 of 5 UPC-E off UPC-E on (default) UPC-E Check Digit Matrix 2 of 5/off Matrix 2 of 5/on (default) Not transmit UPC-E check digit Transmit UPC-E check digit (default) EAN/JAN-8 Code 93 EAN/JAN-8 on (default) Code 93 on EAN/JAN-8 off EAN/JAN-13 Code 93 off (default) EAN/JAN-13 /off EAN/JAN-13 on (default) Code 128 UPC/EAN/JAN Supplement Code 128 off Code 128 on (default) No UPC/EAN/JAN Supplement (default) GS1-128 GS1-128 off GS1-128 on (default) Decode UPC/EAN/JAN Supplement UPC-A UPC/EAN/JAN self-adaption UPC-A off UPC-A on (default) EAN13 Convert into ISBN UPC-A Check Digit Convert EAN13 into ISBN enable Convert EAN13 into ISBN disable (default) Not transmit UPC-A check digit Transmit UPC-A check digit (default) 9 10 EAN13 Convert into ISSN Convert EAN13 into ISSN enable Convert EAN13 into ISSN disable (default) GS1 DataBar(RSS14) GS1DataBar off GS1DataBar on (default) GS1 DataBar Limited GS1 DataBar Limited on GS1 DataBar Limited off (default) GS1 DataBar Expanded GS1DataBar Expanded on GS1DataBar Expanded off (default) 11