APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 1
A P D S M W | M U LT I WAY V I D E O D O O R S TAT I O N
USER MANUAL
www.espuk.com
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 2
Contents System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Door Station Wiring Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Door Station Wiring Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Lock Connection Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Lock Connection Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Door Station Programming Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Door Station Keypad User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installer’s troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
System Cabling All system cabling (excluding mains 240vAC supply) has been tested with Cat5E UTP PVC cable.
Part Number - A8NFORCE5EUTP Find this product online: elandcables.com | Cables & Accessories | LAN Cable | Cat 5E UTP PVC Cable
2
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 3
System Components
APDSMW Multi-Way Door Station
APPOWMW System Power Supply Unit
APSEPMW Power Supply Seperator
APBC4MW System Branch Controller
Installation
1.2 m~1.5 m
90。
Site the door station a recommended 1.5 meters from the ground, or to suit application.
The camera needs to point in the direction of where a visitor will stand during operation.
Avoid areas of high sunlight and noise levels.
Surface mount the sunshield of the door station and connect the system cabling. Mount the camera to the sunshield by fixing with the supplied hex screw.
3
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 4
Door Station Wiring Example 1 System PSU
Address ID 02 +V
-V
E
L
BUS
N
System PSU Seperator
Address ID 01 BUS
4
Ensure the Address ID switches are both set to OFF
Address ID 02 BUS
MASTER
Address ID 01
1 Set up as a Master or Slave SLAVE
240vAC
BUS
Each monitor requires the following:
Cable run between door station and furthest monitor should not exceed 150 meters
Address ID 03 BUS
MASTER
Power supply to be with-in 100 meters of monitor
MASTER
No cable or connection polarity
2 Set up with a unique Address ID: 01-32 Refer to the monitor’s specific Set up guide
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 5
Door Station Wiring Example 2 System PSU Address ID 02
Address ID 03 BUS
BUS
+V
-V
E
L
Address ID 31 BUS
Address ID 01
Address ID 04 BUS
Address ID 30
1 Set up as a Master or Slave
BUS
Address ID 29
BUS
Address ID 32 BUS
Each monitor requires the following:
BUS
2 Set up with a unique Address ID: 01-32 Refer to the monitor’s specific Set up guide
N
240vAC Branch Controller
System PSU Seperator
Each branch controller requires the following;
Branch Controller
1 Adjusted dipswitch settings; ON
When in use with monitors
1 2 3 ON
When in use with door stations 1 2 3
Address ID 01
2 The branch controller at the end of the line has the impedance switch to ON the indication LED will turn amber
Branch Branch Controller Controller
When using multiple door stations ensure that each unit has a seperate Address ID BUS
Address ID 01
Address ID 02
Address ID 03
Address ID 04
The dipswitches are accessible on the rear of the door station
Cable run between door station and furthest monitor should not exceed 150 meters
Power supply to be with-in 100 meters of monitor
No cable or connection polarity
BUS
Address ID 02
5
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 6
Lock Connection Example 1
Electro-magnetic lock
Electronic lock
_ +
Lock -release time 4 3
NC
N.C for Electro-magnetic lock
+ _ + _
N.O for Electronic lock
LOCK1
At the rear of the door station ensure that the jumper links cover pins 1 and 2, on both J3 and J2 positions
VCC
3
2
1
J1
System Wiring
BUS
J2 J3
6
Image of jumper link
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 7
Lock Connection Example 2
Ï jƆƉƑƌƍƆƏƐƆƏƆƏƇƐƆƗƏƐƐƈƇƇƆƏƗƈƇƇƆƏƆƐ types of release modes for alternative applications dependent on the jumper link settings. LOCK1 options;
Ï The door station has a secondary switch. LOCK2 options;
N.O
N.O
Volt-free
Volt-free
3 2 1
3 2 1
J1 J2 J3
J1 J2 J3
N.C
N.C Image of jumper link
Volt-free 3 2 1 J1 J2 J3
Image of jumper link
Volt-free 3 2 1 J1 J2 J3
N.O
N.O
12vDC300mA MAX
12vDC300mA MAX
3 2 1 J1 J2 J3
3 2 1 J1 J2 J3
Ï Please refer to the operation guide for release instructions
7
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 8
Door Station Programming Guide Entering Administration Mode
Press
2 tones will sound
Press
2 tones will sound
Input administrator code (Default: 123456)
Administration Mode has been entered
Setting a lock release code
Enter Administration Mode
Press
2 tones will sound
Press
2 tones will sound
Enter 4 digit code required for door release
A long tone will sound
Press
For code location number
> Continue
8
Press
Re-enter 4 digit code required for door release
Press
to exit and complete setup
The Administrator code will not release the door. A lock release code is required to be programmed
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 9
Door Station Programming Guide Deleting a lock release code
Enter Administration Mode
Press
Enter code Location Number
2 tones will sound
Press
A long tone will sound
Press
to exit and complete setup
Changing the Administrator code
Enter Administration Mode
Press
Enter new 6 digit Administration Code
Press
Re-enter new 6 digit Administration Code
Press
A long tone will sound
Press
to exit and complete setup
9
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 10
Door Station Keypad User Guide Making a visitors call
Press Address ID number of monitor
Press ‘Bell’ symbol to call
Tones will sound until call is answered
Using the lock release code
Enter 4 digit lock release code
10
Press The lock will release
Begin conversation when call is accepted
Refer to monitor’s instructions for further options
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 11
Installer’s troubleshooting Guide In the event of no video or audio signals coming from the monitor, or if the call button or audio cannot be activated on the door station, check the following:
A That the system is powered sufficiently. B Each monitor needs to have set an Address ID, set to a master or slave position and configured Video Match switch. C All system cabling is secured and properly connected. D All system cabling is clear of breaks or short circuits. E Bench test the system if the issue cannot be found.
In the event of a lock release issue, check the following:
A B C D E
In event of 5 tones sounding from keypad during programming:
The user instructions and operation of the monitor has been understood. That the lock is powered sufficiently. All system cabling is secured and properly connected. All system cabling is clear of breaks or short circuits. On the rear of the door station, ensure the lock output is switching when activated by the monitor.
A Please check an incorrect command has not been entered. B The code that has been entered is already in use.
Optional Accessories
APMONW/ APMONB Monitor white/black
APMONWG / APMONBG EVBPSBB Monitor white/black Lock Power Supply
EV-EXIT Push To Release
EV-EBG Emergency Release
EV-ML-250/500XT Electro-magnetic Lock
ENTERD Electric Lock
11
APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 12
Telephone: 01527 51 51 50 Fax: 01527 51 51 43 email:
[email protected]
Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN
E&OE - Errors and omissions excepted. A16
www.espuk.com