Preview only show first 10 pages with watermark. For full document please download

User Manual Apdsmw | Multiway Video Door Station

   EMBED


Share

Transcript

APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 1 A P D S M W | M U LT I WAY V I D E O D O O R S TAT I O N USER MANUAL www.espuk.com APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 2 Contents System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Door Station Wiring Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Door Station Wiring Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Lock Connection Example 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Lock Connection Example 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Door Station Programming Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Door Station Keypad User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installer’s troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 System Cabling All system cabling (excluding mains 240vAC supply) has been tested with Cat5E UTP PVC cable. Part Number - A8NFORCE5EUTP Find this product online: elandcables.com | Cables & Accessories | LAN Cable | Cat 5E UTP PVC Cable 2 APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 3 System Components APDSMW Multi-Way Door Station APPOWMW System Power Supply Unit APSEPMW Power Supply Seperator APBC4MW System Branch Controller Installation 1.2 m~1.5 m 90。 Site the door station a recommended 1.5 meters from the ground, or to suit application. The camera needs to point in the direction of where a visitor will stand during operation. Avoid areas of high sunlight and noise levels. Surface mount the sunshield of the door station and connect the system cabling. Mount the camera to the sunshield by fixing with the supplied hex screw. 3 APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 4 Door Station Wiring Example 1 System PSU Address ID 02 +V -V E L BUS N System PSU Seperator Address ID 01 BUS 4 Ensure the Address ID switches are both set to OFF Address ID 02 BUS MASTER Address ID 01 1 Set up as a Master or Slave SLAVE 240vAC BUS Each monitor requires the following: Cable run between door station and furthest monitor should not exceed 150 meters Address ID 03 BUS MASTER Power supply to be with-in 100 meters of monitor MASTER No cable or connection polarity 2 Set up with a unique Address ID: 01-32 Refer to the monitor’s specific Set up guide APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 5 Door Station Wiring Example 2 System PSU Address ID 02 Address ID 03 BUS BUS +V -V E L Address ID 31 BUS Address ID 01 Address ID 04 BUS Address ID 30 1 Set up as a Master or Slave BUS Address ID 29 BUS Address ID 32 BUS Each monitor requires the following: BUS 2 Set up with a unique Address ID: 01-32 Refer to the monitor’s specific Set up guide N 240vAC Branch Controller System PSU Seperator Each branch controller requires the following; Branch Controller 1 Adjusted dipswitch settings; ON When in use with monitors 1 2 3 ON When in use with door stations 1 2 3 Address ID 01 2 The branch controller at the end of the line has the impedance switch to ON the indication LED will turn amber Branch Branch Controller Controller When using multiple door stations ensure that each unit has a seperate Address ID BUS Address ID 01 Address ID 02 Address ID 03 Address ID 04 The dipswitches are accessible on the rear of the door station Cable run between door station and furthest monitor should not exceed 150 meters Power supply to be with-in 100 meters of monitor No cable or connection polarity BUS Address ID 02 5 APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 6 Lock Connection Example 1 Electro-magnetic lock Electronic lock _ + Lock -release time 4 3 NC N.C for Electro-magnetic lock + _ + _ N.O for Electronic lock LOCK1 At the rear of the door station ensure that the jumper links cover pins 1 and 2, on both J3 and J2 positions VCC 3 2 1 J1 System Wiring BUS J2 J3 6 Image of jumper link APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 7 Lock Connection Example 2 Ï jŒƆƉƑƌƍƆƏ”•ƐŒƆƏƆ“Ə”ƇƐŒƆƗ””ƏƐ“Ɛƈ”•”ƇƇƆƏƗƈƇƇƆƏƆ•Ɛ types of release modes for alternative applications dependent on the jumper link settings. LOCK1 options; Ï The door station has a secondary switch. LOCK2 options; N.O N.O Volt-free Volt-free 3 2 1 3 2 1 J1 J2 J3 J1 J2 J3 N.C N.C Image of jumper link Volt-free 3 2 1 J1 J2 J3 Image of jumper link Volt-free 3 2 1 J1 J2 J3 N.O N.O 12vDC300mA MAX 12vDC300mA MAX 3 2 1 J1 J2 J3 3 2 1 J1 J2 J3 Ï Please refer to the operation guide for release instructions 7 APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 8 Door Station Programming Guide Entering Administration Mode Press 2 tones will sound Press 2 tones will sound Input administrator code (Default: 123456) Administration Mode has been entered Setting a lock release code Enter Administration Mode Press 2 tones will sound Press 2 tones will sound Enter 4 digit code required for door release A long tone will sound Press For code location number > Continue 8 Press Re-enter 4 digit code required for door release Press to exit and complete setup The Administrator code will not release the door. A lock release code is required to be programmed APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 9 Door Station Programming Guide Deleting a lock release code Enter Administration Mode Press Enter code Location Number 2 tones will sound Press A long tone will sound Press to exit and complete setup Changing the Administrator code Enter Administration Mode Press Enter new 6 digit Administration Code Press Re-enter new 6 digit Administration Code Press A long tone will sound Press to exit and complete setup 9 APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 10 Door Station Keypad User Guide Making a visitors call Press Address ID number of monitor Press ‘Bell’ symbol to call Tones will sound until call is answered Using the lock release code Enter 4 digit lock release code 10 Press The lock will release Begin conversation when call is accepted Refer to monitor’s instructions for further options APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 11 Installer’s troubleshooting Guide In the event of no video or audio signals coming from the monitor, or if the call button or audio cannot be activated on the door station, check the following: A That the system is powered sufficiently. B Each monitor needs to have set an Address ID, set to a master or slave position and configured Video Match switch. C All system cabling is secured and properly connected. D All system cabling is clear of breaks or short circuits. E Bench test the system if the issue cannot be found. In the event of a lock release issue, check the following: A B C D E In event of 5 tones sounding from keypad during programming: The user instructions and operation of the monitor has been understood. That the lock is powered sufficiently. All system cabling is secured and properly connected. All system cabling is clear of breaks or short circuits. On the rear of the door station, ensure the lock output is switching when activated by the monitor. A Please check an incorrect command has not been entered. B The code that has been entered is already in use. Optional Accessories APMONW/ APMONB Monitor white/black APMONWG / APMONBG EVBPSBB Monitor white/black Lock Power Supply EV-EXIT Push To Release EV-EBG Emergency Release EV-ML-250/500XT Electro-magnetic Lock ENTERD Electric Lock 11 APDSMW Manual.qxp_Layout 1 29/01/2016 13:01 Page 12 Telephone: 01527 51 51 50 Fax: 01527 51 51 43 email: [email protected] Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN E&OE - Errors and omissions excepted. A16 www.espuk.com