User Manual - Xpelair Australia

   EMBED


Share

Transcript

Please read the user manual carefully before using the product GG52Eng USER MANUAL Split System Air Conditioner Foreword Please ensure your air conditioner is installed and repaired by an authorised technician. Unauthorised repairs or installation may result in the loss of warranty and can endanger the user and their property. This instruction manual is intended for general use with various models of split air conditioners within our product range. Please note that your product and the units found in this manual may vary slightly. For specific details about your product, please refer to the relevant sections . Please keep this manual as a reference for operation. Please note: Please note, this product is not intended for use by young children. Please ensure children using this product are supervised by an adult to ensure safe operation. Contents User Instructions Parts and Functions Remote Controller Functions Use of Remote Controller Heating Functions Maintenance Service Troubleshooting 1 3 8 19 24 25 26 27 USER MANUAL *User Instructions* Split Wall-Mounted Air Conditioner Please read the "Instruction Manual" carefully prior to the use of your air conditioner to ensure proper operation. Instructions for Installation * This appliance must be installed by a qualified installer. 1.The units are not to be installed in places where there might be a leakage of combustible gases. Make sure that the earth leakage-circuit breaker is installed. S K Earth leakagecircuit breaker Absence of the earth leakage-circuit breaker might lead to electrical and other hazards. Accumulated leaking gas creates a potential fire hazard. After the connecting the wires between the indoor unit and outdoor unit; ensure the connections are tight. Make sure that the air conditioner is properly grounded. A loose connection might result in a fire hazard. The earthing wire on the air conditioner should be tightly connected to the earth of the power source. Improper grounding might cause electric shocks or other hazards. Instructions for Operation Do not attempt to stop the unit by pulling out the power cord. Do not connect unit to a power board or use an extension lead. Do not press, stretch, damage, heat or modify the power cord. Wrong! This might cause an electrical or fire hazard. Do not operate the power point with wet hands. It might cause overheating, electrical or fire hazards, or other accidents. Before the appliance is plugged in, please ensure there is no dust on it and that it is plugged in correctly. It might cause overheating, electrical or fire hazards, etc. If the power cord is damaged or needs to be replaced, discontinue use of the unit until the cord is replaced by a qualified person. Only use the correct sized breaker copper wire It might cause an electrical hazard. If there is dust on the plug or if the plug is not in place, it might cause electric shocks or fire hazards. The use of metal or copper wires for the fuse might cause operational failures or fire hazards. 1 USER MANUAL Split Wall-Mounted Air Conditioner For greater efficiency, try to avoid direct sunlight and hot air from entering the room. Try to minimize the generation of heat while the unit is in operation. Do not use combusting apparatuses in the air-conditioned room. During the cooling operation, curtains or windowblinds should be used to shade off the sunlight. Place the heating sources out of the room. It might lead to the incomplete combustion of these apparatuses. Do not place insecticides, paints or other flammable sprays near the air conditioner, or spray them directly at the unit. When it is necessary to use the air conditioner and combusting apparatuses in the same room, air ventilation has to be provided. Prior to the maintenance of the air conditioner, please cut off the power supply first. Never clean the units when the fan is in operation. I'm scorched! Lack of oxygen! It might cause fire hazards. Insufficient ventilation might lead to lack of oxygen or some other dangers. Do not insert sticks or bars into the vents. Adjust the air direction correctly. Do not keep exposed to the cool air for long time. Dangerous! As the fan is in high-speed operation, the insertion might lead to accidents. Do not clean the air conditioner with water. It might cause electric shocks. Do not sit on the outdoor unit or place any other objects on it. Properly adjust the up/down and left/right directions of the air flow for even room temperature. Do not attach, hang or stack articles on the air conditioner. It might lead to the dislodgement of the air conditioner unit, which may result in injuries. Do not use the following substances: Hot water (over 40 C or 104°F) The use of hot water will deform the air conditioner or make it fade in color. Gasoline, paint diluent, benzene and polishing agents, etc. These substances will deform the air conditioner or cause scratches. It might cause discomfort, which may be harmful to your health. Check the supporting structures of the unit carefully. In case of damage, the supporting structures should be immediately repaired to avoid dislodgement of the unit, which might cause injuries. Pull out the plug when the unit is not in use for long time to ensure safety. 0 This may result in damage to the unit and any items that may fall off of it. When the plug is pulled out, make sure that the air conditioner is turned off. Instructions for Removal and Repair * When removal or repair is needed, please contact the dealer or an authorised technician. * In case of any abnormal occurrences (i.e. burning smell), stop operation of the unit immediately and contact the dealer or an authorised technician. 2 USER MANUAL *Parts and Functions* Split Wall-Mounted Air Conditioner This manual is intended as a guide only, some models and features may vary from the actual product. For other models please refer to supplied user manual. Indoor Unit Operational performance indicators Air return grid Takes in the indoor air Indicators of unit 1 Power indicator RUN Timer indicator TIMER d Setting temperature, timer duration and failure code indicator Left/right air flow direction adjusting fin Up/down air flow direction adjusting fin Indicators of unit 2 Air outlet TURBO operation indicator Air blows out from here Temperature setting,timer duration and malfunction code indicator Air filter Removes dust or dirt from the inlet air Drain tube Timer indicator Drains water produced from dehumidifying the air. Power indicator Outdoor Unit Receiver of remote controller signal Air inlet at sides and rear surface Refrigerant piping connection, Electric wiring cord Air discharge vent Unit operation section How to open How to close Push down the air inlet grid and then push both sides of air inlet grid at the bottom. Emergency operation key Lightly push both sides of the air inlet grid at the bottom and pull it to this side till a resistance is felt. This button can be used as an emergency measure to turn on/off unit when remote controller is not available. * Note: Do not open the grid at an angle over 60 degrees. Do not operate the unit with too much force. 3 USER MANUAL Indicators of unit 3 Split Wall-Mounted Air Conditioner Receiver of remote controller signal Turbo Timer indicator Power indicator Turbo operation indicator Indicators of unit 4 Receiver of remote control signal Indicators of unit 6 Fan speed indicator Setting temperature,timer time and malfunction code indicator Power indicator Receiver of remote control signal Indicators of unit 5 Temperature setting,timer duration and malfunction code indicator Sleep indicator TURBO operation indicator Timer indicator Power indicator Power indicator Timer indicator Setting temperature,timer duration and malfunction code indicator Sleep indicator Receiver of remote control signal Power indicator Indicators of unit 7 Receiver of remote control signal RUN TIMER Timer indicator TURBO operation indicator TURBO SLEEP SLEEP indicator Temperature setting, timer duration and malfunction code indicator Indicators of unit 8 Power indicator Timer indicator Receiver of remote control signal Temperature setting, timer duration and malfunction code indicator 4 USER MANUAL Split Wall-Mounted Air Conditioner Indicators of unit 9 Fin swinging indicator Dehumidifying indicator Heating indicator (cooling and heating model) Cooling indicator Auto mode indicator Sleeping indicator h C Fan speed indicator Temperature setting and malfunction code indicator Timer duration indicator Indoor fan motor running display Indicators of unit 10 Receiver of remote controller signal Fan speed indicator Temperature setting,timer duration and malfunction code indicator Timer indicator Indicators of unit 11 Power indicator Sleep indicator Receiver of remote controller signal Timer indicator Temperature setting,timer duration and malfunction code indicator Indicators of unit 12 Power indicator Timer indicator Temperature setting,timer duration and malfunction code indicator Receiver of remote controller signal Indicators of unit 13 Power indicator Receiver of remote controller signal Temperature setting, timer duration and malfunction code indicator Sleep indicator Timer indicator 5 USER MANUAL Split Wall-Mounted Air Conditioner Indicators of unit 15 Indicators of unit 14 Power indicator Sleep indicator Sleep indicator Temperature setting,timer duration and malfunction code indicator Timer indicator Receiver of remote controller signal Power indicator Timer indicator Temperature setting,timer duration and malfunction code indicator Indicators of unit 16 Sleep indicator Power indicator Timer indicator Temperature setting,timer duration and malfunction code indicator Receiver of remote controller signal Indicators of unit 17 Power indicator Sleeping indicator Receiver of remote controller signal Timer indicator Indicators of unit 18 Cooling indicator Timer indicator 6 Dehumidifying indicator Heating indicator (cooling and heating model) Temperature setting,timer duration and malfunction code indicator Ventilate Sleep indicator Temperature setting,timer duration and malfunction code indicator Turbo operation indicator USER MANUAL Indicators of unit 19 Split Wall-Mounted Air Conditioner Indicators of unit 21 Temperature setting,timer duration and malfunction code indicator Timer indicator Power indicator Sleep indicator Indicators of unit 20 Indicators of unit 22 Temperature setting,timer duration and malfunction code indicator Sleep indicator Timer indicator Temperature setting,timer duration and malfunction code indicator Power indicator Receiver of remote controller signal Indicators of unit 23 Power indicator Temperature setting,timer duration and malfunction code indicator Indicators of unit 24 Fan speed indicator Indicators of unit 25 Timer indicator Power indicator Temperature setting, timer duration and malfunction code indicator Indicators of unit 26 Temperature setting, timer duration and malfunction code indicator Temperature setting, timer duration and malfunction code indicator 7 USER MANUAL Split Wall-Mounted Air Conditioner *Remote Controller Functions* Attention: 1.The appearances of the following three remote controllers will vary,but the functions of the buttons are same, Please refer to the instructions for the correct remote controller of your air-conditioner. 2.The Remote Controllers 1, 2, 3, 4 and 5 are used for various models of air-conditioners. The "LAMP" and "CLEAN" button are only applicable for newly developed models. The "AIR FLOW" button is an optional function button, that only works on models with three-dimensional air flow function. Remote Controller 1 Temperature indicator FAN SPEED indicator Indicates the set temperature. Indicates the selected air speed. OPERATION MODE indicator SLEEP indicator indicates selected operation mode TIME indicator Indicates timer duration. Indicates during sleep operation. TURBO indicator AUTO COOL DRY HEAT FAN OPERATION MODE select button SLEEP LAMP MODE TURBO ON OFF CLEAN HOLD TEMP SET TEMPERATURE button ON/OFF This button sets the room temperature. ON/OFF button SWING button This button, when pressed starts operation and stops when re-pressed. FAN SPEED SWING AIR FLOW TIMER HOLD SLEEP FAN SPEED button This button set air speed. TIMER button This button is used to set the switch-on or switch-off and the timer duration. TURBO button This button changes to TURBO operation (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SWING indicator Indicates selected fin mode. Key lock indicator This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. Indicates during TURBO operation. TURBO LAMP CLEAN This button changes the fin mode:natural flow, swing or fixed. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) SLEEP button This button changes to SLEEP operation. HOLD button Press this button to lock or unlock the keyboard. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 8 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 2 Temperature indicator Indicates the set temperature. AUTO indicator SLEEP indicator COOLING indicator Indicates during sleep operation. DEHUMIDIFYING indicator TURBO indicator HEATING indicator Indicates during TURBO operation. FAN indicator Key lock indicator ON OFF SWING indicator FAN SPEED indicator Indicates selected fin mode. Indicates the selected air speed. TIME indicator ON/OFF Indicates timer duration. SET TEMPERATURE button and stops when re-pressed. This button sets the room temperature. MODE button This button changes the operation mode: AUTO,COOL, DEHUMIDIFY,HEAT,FAN. FAN SPEED button This button set air speed. TURBO button This button changes to TURBO operation (It does not work in AUTO,DEHUMIDIFY, and FAN mode.) TIMER button This button is used to set the switch-on or switch-off and the timer duration. ON/OFF button This button, when pressed starts operation SWING button MODE SWING FAN S PEED TIMER TUR BO HOLD R FLOW AI P SLEE LAMP This button changes the fin mode:natural flow ,swing or fixed. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) SLEEP button This button changes to SLEEP operation. HOLD button Press this button to lock or unlock the keyboard. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 9 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 3 FAN SPEED indicator Indicates the selected air speed. AUTO indicator COOLING indicator DEHUMIDIFYING indicator HEATING indicator FAN indicator SLEEP indicator Indicates during sleep operation. TURBO indicator Indicates during TURBO operation. ON/OFF button This button, when pressed starts operation and stops when re-pressed. MODE button This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. SWING button This button changes the fin mode:natural flow,swing or fixed wind. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) TIMER button This button is used to set the switch-on or switch-off and the timer duration. Temperature indicator Indicates the set temperature. TIME indicator Indicates timer duration. SWING indicator Indicates selected fin mode. TIME OFF indicator AIR FLOW indicator TIME ON indicator SET TEMPERATURE button This button sets the room temperature. FAN SPEED button This button set air speed. TIME SET button This button set present time. TURBO button This button changes to TURBO operation (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SLEEP button This button changes to SLEEP operation. CLOCK button This button is used to set time. RESET button This button let computer reset. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 10 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 4 Temperature indicator Indicates the set temperature. FAN SPEED indicator Indicates the selected air speed. AUTO indicator FAN indicator COOLING indicator SLEEP indicator Indicates during sleep operation. DEHUMIDIFYING indicator TURBO indicator HEATING indicator Indicates during TURBO operation. Key lock indicator TIME indicator ON/OFF button Indicates timer duration. OPERATION MODE select button This button, when pressed starts operation This button changes the operation mode: AUTO, COOL, DEHUMIDIFY, HEAT, FAN. and stops when re-pressed. FAN SPEED button This button set air speed. SWING button TIMER button This button changes the fin mode:natural flow, swing or fixed. This button is used to set the switch-on or switch-off and the timer duration. AIR FLOW button(optional) HOLD button This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) Press this button to lock or unlock the keyboard. TURBO button SLEEP button This button changes to TURBO operation This button changes to SLEEP operation. (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SET TEMPERATURE button This button sets the room temperature. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 11 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 5 Temperature indicator Indicates the set temperature. TIME indicator DEHUMIDIFYING indicator Indicates timer duration. COOLING indicator FAN SPEED indicator Indicates the selected air speed. AUTO indicator HEATING indicator TURBO indicator FAN indicator Indicates during TURBO operation. SLEEP indicator Key lock indicator Indicates during sleep operation. TURBO button SLEEP button This button changes to TURBO operation This button changes to SLEEP operation. (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) TIMER button This button is used to set the switch-on or switch-off and the timer duration. FAN SPEED button This button set air speed. HOLD button SWING button Press this button to lock or unlock the keyboard. This button changes the fin mode:natural flow, swing or fixed. AIR FLOW button(optional) ON/OFF button This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) This button, when pressed starts operation and stops when re-pressed. OPERATION MODE select button This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. SET TEMPERATURE button This button sets the room temperature. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 12 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 6 Temperature indicator Indicates the set temperature. TIME indicator DEHUMIDIFYING indicator Indicates timer duration. COOLING indicator FAN SPEED indicator Indicates the selected air speed. AUTO indicator HEATING indicator TURBO indicator FAN indicator Indicates during TURBO operation. SLEEP indicator Key lock indicator Indicates during sleep operation. SLEEP button TURBO button This button changes to SLEEP operation. This button changes to TURBO operation TIMER button (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) FAN SPEED button FOLLOW ME This button is used to set the switch-on or switch-off and the timer duration. FOLLOW ME button This button set air speed. The remote location of the temperature sensing. HOLD button SWING button Press this button to lock or unlock the keyboard. This button changes the fin mode:natural flow, swing or fixed. AIR FLOW button(optional) ON/OFF button This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) This button, when pressed starts operation and stops when re-pressed. OPERATION MODE select button This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. SET TEMPERATURE button This button sets the room temperature. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 13 USER MANUAL Split Wall-Mounted Air Conditioner Temperature indicator Indicates the set temperature. Remote Controller 7 AUTO indicator COOLING indicator DEHUMIDIFYING indicator HEATING indicator FAN indicator SLEEP indicator Indicates during sleep operation. TURBO indicator Indicates during TURBO operation. Key lock indicator FAN SPEED indicator Indicates the selected air speed. ON/OFF button MODE button This button changes the operation mode: AUTO, COOL, DEHUMIDIFY, HEAT, FAN. FAN SPEED button This button, when pressed starts operation and stops when re-pressed. SET TEMPERATURE button This button sets the room temperature. This button set air speed. TURBO button This button changes to TURBO operation (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SWING button This button changes the fin mode:natural flow ,swing or fixed wind. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) RESET button TIMER button This button is used to set the switch-on or switch-off and the timer duration. HOLD button Press this button to lock or unlock the keyboard. °C/°F button The temperature and drgree of switing This button let computer reset. CLOCK button This button is used to set time. SLEEP button This button changes to SLEEP operation. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 14 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 8 AUTO indicator COOLING indicator DEHUMIDIFYING indicator HEATING indicator FAN indicator Temperature indicator Indicates the set temperature. SLEEP indicator Indicates during sleep operation. TURBO indicator Indicates during TURBO operation. Key lock indicator FAN SPEED indicator Indicates the selected air speed. ON/OFF button MODE button This button changes the operation mode: AUTO, COOL, DEHUMIDIFY, HEAT, FAN. FAN SPEED button This button, when pressed starts operation and stops when re-pressed. SET TEMPERATURE button This button sets the room temperature. This button set air speed. TURBO button This button changes to TURBO operation (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SWING button This button changes the fin mode:natural flow ,swing or fixed. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) RESET button This button let computer reset. TIMER button This button is used to set the switch-on or switch-off and the timer duration. HOLD button Press this button to lock or unlock the keyboard. FOLLOW ME button The remote location of the temperature sensing. SLEEP button This button changes to SLEEP operation. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 15 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 9 Temperature indicator Indicates the set temperature. AUTO indicator COOLING indicator DEHUMIDIFYING indicator SLEEP indicator Indicates during sleep operation. TURBO indicator Indicates during TURBO operation. Key lock indicator HEATING indicator FAN indicator FAN SPEED indicator Indicates the selected air speed. ON/OFF button MODE button This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. This button, when pressed starts operation and stops when re-pressed. SET TEMPERATURE button This button sets the room temperature. FAN SPEED button This button set air speed. TURBO button This button changes to TURBO operation (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SWING button This button changes the fin mode:natural flow ,swing or fixed. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) 8 C HEAT button This button is used to start or stop the 8 C HEAT function. Reset button This button let computer reset. C/ F button This button is used to switch between Fahrenheit and Celsius. CLOCK button This button is used to set time. TIMER button This button is used to set the timed switchon,the timed switch-off,or cancel the timer duration. SHORT CUT button This button is used to fast switching the needed setting. SLEEP/CLEAN button This button is a composite button,when pressed shift button switches the function between sleep and clean button. ION/INTE EYE button This button is a composite button,when pressed shift button switches the function between ION and EYE button. LAMP/HOLD button This button is a composite button,when pressed shift button switches the function between LAMP and HOLD SHIFT button This button is used to shift the function on the composite button.(ION/INTE EYE, SLEEP/CLEAN,FRESH/FOLLOW ME, LAMP/HOLD.) FRESH/FOLLOW ME button This button is a composite button.when pressed shift button switches the function between FRESH and FOLLOW ME. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 16 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller10 Temperature indicator Indicates the set temperature. OPERATION MODE indicator indicates selected operation mode TIME indicator Indicates timer duration. OPERATION MODE select button This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. ON/OFF button FAN SPEED indicator Indicates the selected air speed. TURBO indicator Indicates during TURBO operation. SWING indicator Indicates selected fin mode. Key lock indicator SET TEMPERATURE button This button sets the room temperature. This button, when pressed starts operation and stops when re-pressed. FAN SPEED button This button set air speed. TIMER button This button is used to set the switch-on or switch-off and the timer duration. TURBO button This button changes to TURBO operation (It does not work in AUTO, DEHUMIDIFY, and FAN mode.) SWING button This button changes the fin mode:natural flow, swing or fixed. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) SLEEP button This button changes to SLEEP operation. CLEAN button Press this button to CLEAN. HOLD button Press this button to lock or unlock the keyboard. ION button Switch the button control negative icon function. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. 17 USER MANUAL Split Wall-Mounted Air Conditioner Remote Controller 11 Temperature indicator Indicates the set temperature. SLEEP indicator AUTO indicator COOLING indicator DEHUMIDIFYING indicator Indicates during sleep operation. TURBO indicator Indicates during TURBO operation. Key lock indicator HEATING indicator FAN indicator FAN SPEED indicator Indicates the selected air speed. ON/OFF button MODE button This button changes the operation mode: AUTO,COOL,DEHUMIDIFY,HEAT,FAN. FAN SPEED button This button, when pressed starts operation and stops when re-pressed. SET TEMPERATURE button This button sets the room temperature. This button set air speed. TURBO button This button changes to TURBO operation (It does not work in AUTO,DEHUMIDIFY, and FAN mode.) SWING button This button changes the fin mode:natural flow, swing or fixed. AIR FLOW button(optional) This button is used for selection of the left/right air flow direction. When pressed the function will change and the fins will alternate between swing or fixed. (3D Airflow models only) RESET button This button let computer reset. SLEEP button This button changes to SLEEP operation. TIMER button This button is used to set the switch-on or switch-off and the timer duration. IONIZER button Switch the button control negative icon function. HOLD button C/ F button This button is used to switch Fahrenheit and Celsius. CLOCK button This button is used to set time. Press this button to lock or unlock the keyboard. FOLLOW ME button The remote location of the temperature sensing. NOTE: * Above figure shows all operations for the indicated remote. Functions may vary depending on air conditioner model in use. ie. Cooling Only Model - HEAT function is replaced by FAN function. * When TURBO operation is in use, room temperature setting remains constant. To adjust temperature, TURBO operation must be cancelled. Transmission procedure AUTO COOL SLEEP LAMP DRY HEAT FAN MODE POWER ON OFF CLEAN HOLD TEMP ON/OFF FAN SPEED 18 SWING Air Flow TIMER HOLD SLEEP HI POWER LAMP CLEAN When each button on the remote controller is pressed whilst pointing toward the air conditioner unit, a signal is sent. When the signal is received correctly, the unit will emit a "receiving" signal. USER MANUAL Split Wall-Mounted Air Conditioner *Use of Remote Controller* OPERATING MACHINE IN SELECTED MODES Remote Controller 1, 2, 4, 5, 6, 10 and 11 1.Point the remote controller at the unit, press the ON/OFF button,then press the MODE button, select the desired mode: AUTO,COOL,DEHUMIDIFY,HEAT,or FAN. 2. Press the SET TEMPERATURE button to increase or decrease the indicator value until the desired temperature is displayed. The room set temperature range is from 16°C-32°C(61°F-90°F). (It will be automatically set at 25°C(76°F) and cannot be adjusted in AUTO and DEHUMIDIFY mode.) 3. Press the FAN SPEED button to choose the air speed you want: Low(display indicates" indicates " ", Hi(display indicates" ", Auto(display" "), Med(display "indicator flashing). (It would be automatically set at low speed and cannot be adjusted in DEHUMIDIFY mode.) 4. Press the SWING button to choose the desired up/down air flow direction: natural flow( display" flashing), swing(display" " indicator flashing), fixed (display indicates " "). Unit will be automatically set at fixed air flow direction in DEHUMIDIFY mode.) "indicator Remote Controller 3 1. Point the remote controller at the unit, press the ON/OFF button, then press the MODE button to select the desired mode: AUTO, COOL, DEHUMIDIFY, HEAT or FAN. 2. Press the SET TEMPERATURE button to increase or decrease the indicator value until the desired temperature is displayed. The room set temperature range is from 16°C-32°C(61°F-90°F). (It will be automatically set at 25°C(76°F) and cannot be adjusted in AUTO and DEHUMIDIFY mode.) 3. Press the FAN SPEED button to choose the air speed you want: Low(display indicates" indicates " ", Hi(display indicates" ", Auto(display" "), Med(display "indicator flashing). (It would be automatically set at low speed and cannot be adjusted in DEHUMIDIFY mode.) 4. Press the SWING button to choose the desired up/down air flow direction: natural flow( display" " indicator flashing), fixed (display indicates " "). flashing), swing(display" Unit will be automatically set at fixed air flow direction in DEHUMIDIFY mode.) 5. Press the AIR FLOW button to choose the desired left/right direction: swing(display" fixed (display indicates " "indicator " indicator flashing), "). To be in compliance EN61000-3-11,the product shall be connected only to a supply of the system impedance: |Zsys|=0 .141 ohms or less. Before connecting the product to public power network, please consult your local power supply authority to ensure the power network meets the above requirements. 19 USER MANUAL Split Wall-Mounted Air Conditioner *Use of Remote Controller* OPERATING MACHINE IN SELECTED MODES Remote Controller 7, 8 and 9 1. Point the remote controller at the unit,press the ON/OFF button,then press the MODE button to select the desired mode: AUTO, COOL, DEHUMIDIFY, HEAT or FAN. 2. Press the SET TEMPERATURE button to increase or decrease the indicator value until the desired temperature is displayed. The room set temperature range is from 16°C-32°C(61°F-90°F). (It will be automatically set at 25°C(76°F) and cannot be adjusted in AUTO and DEHUMIDIFY mode.) 3. Press the FAN SPEED button to choose the air speed you want: Low(display indicates" "), Med(display indicates " ", Hi(display indicates" ", Auto(display" "indicator flashing). (It would be automatically set at low speed and cannot be adjusted in DEHUMIDIFY mode.) 4. Press the SWING button to choose the desired up/down air flow direction: natural flow( display" "indicator flashing), swing(display" " indicator flashing), fixed (display indicates " "). Unit will be automatically set at fixed air flow direction in DEHUMIDIFY mode.) 5. Press the AIR FLOW button to choose the desired left/right direction: swing(display" fixed (display indicates " " indicator flashing), "). 6. Press the ION button, display indicates " " 7.Press the INTE EYE button, display indicates “ ”. 8.Press the FRESH button, no indicator displays on the screen. To be in compliance EN61000-3-11,the product shall be connected only to a supply of the system impedance: | Zsys|=0 .141 ohms or less. Before connecting the product to public power network, please consult your local power supply authority to ensure the power network meets the above requirements. *BUTTON OPERATION* Remote Controller 9 1.ON/OFF button: This button is used to activate or deactivate operation of the machine. 2.MODE button: This button is used to change the operation mode: AUTO, COOL, DEHUMIDIFY, HEAT, FAN. 3. button: This button is used to increase the temperature. 4. button: This button is used to decrease the temperature. 5. AIR FLOW button: This button is used to select the left or right air flow direction, when pressed the fin will swing or remain fixed. (Only available on 3D model.). 6.Swing button: This button is used to change the fin mode: natural flow, swing or fixed. 7.FAN SPEED button: This button is used to set air speed. 8. TIMER button: This button is used to set the timed switch on, the timed switch off, or cancel the timer setting. Press the TIMER button for the first time; the hours setting flashes on the indicator. Use to set the hours for the desired timed switch-on of the unit. Press the TIMER button for the second time; the minutes setting flashes on the indicator. Use to set the minutes for the desired timed switch-on of the unit. Press the TIMER button for the third time; the TIMER setting will be implemented by following: When the TIMER button is pressed twice, but the hours/minutes are not set using the switch on setting is cancelled. 20 buttons, the timed USER MANUAL Split Wall-Mounted Air Conditioner When the TIMER button is pressed twice, and the hours/minutes are set using the switch on is set and the signal is sent to the unit. buttons, the timed Press the TIMER button for the fourth time; the hours setting flashes on the indicator. Use the set the hours for the desired timed switch-off. Press the TIMER button for the fifth time; the minutes setting flashes on the indicator. Use the set the hours for the desired timed switch-off. Press the TIMER button for the sixth time; the TIMER setting will be implemented by following: buttons to buttons to When the TIMER button is pressed, but the hours/minutes are not set using the buttons, the timed switch off setting is cancelled. When the TIMER button is pressed, and the hours/minutes are set using the buttons, the timed switch off is set and the signal is sent to the unit. After setting the timed switch-off, pressing TIMER button again, will cancel the TIMER function setting. (timed switch-on or timed switch-off) After setting the timed switch off/on function without pressing TIMER button again, the function set time will show on the display screen (clock time will not show on the display screen). Pressing the CLOCK button, allows for the clock time to be shown on the display, but once it is released the function set time will be shown again. 9. TURBO button: This button activates the TURBO operation. The TURBO function button will only work during COOLING or HEATING functions. (Does not work in AUTO, DEHUMIDIFY and FAN modes) If the SLEEP function is activated, it will automatically cancel the TURBO function. 10.CLOCK button (CLK): This button is used to set the time. Press this button to change the CLOCK setting. The time can be changed by pressing ON-OFF button or pressing CLOCK button again to complete the time setting. The time setting will automatically complete when the indicator stops flashing after 15 seconds. 11. SHORT CUT button: This button is used for rapid setting change. A long press of the SHORT CUT button will activate the flashing indicators “ ”“ ”. Select the desired short cut parameters (operation mode, temperature, fan speed, turbo, sleep, air flow etc.). After desired selection is made, press SHORT CUT button again, and the indicator “ ”“ ” will no longer show on the display screen, meaning the selected parameters will be stored. A short press of the SHORT CUT button will set the unit to run the previously set parameters. (SHORT CUT function does not impact or store TIMER, CLOCK and HOLD functions.) 12. 8°C HEAT button: This button is used to start or stop the 8°C HEAT function. 13. SHIFT button: This button allows for the use of alternate functions on the composite buttons (ION/INTE EYE,SLEEP/CLEAN,FRESH/FOLLOW ME, LAMP/HOLD). By pressing the SHIFT button, the right arrow indicator flashes indicating the second button function is available (when a composite button is pressed). Pressing the SHIFT button again (or not pressing any buttons for 30 seconds) cancels the alternate function. 14. ION/INTE EYE button: This button is a composite button. (Pressing SHIFT switches the function between ION and INTE EYE.) ION; when pressed this button activates or cancels the ION function. INTE EYE; when pressed this button activates or cancels the INTE EYE function. 15. SLEEP/CLEAN button: This button is a composite button. Pressing SHIFT switches the function between SLEEP and CLEAN. (The CLEAN function is only effective when the remote control is turned off.) Pressing the SLEEP button activates and/or cancels the sleep function. When the sleep function is active, the fan speed will automatically switch to low. The fan speed can be changed using the FAN SPEED button. If the turbo function is activated, the sleep function will be cancelled. 21 USER MANUAL Split Wall-Mounted Air Conditioner 16. LAMP/HOLD button: This button is a composite button. (Pressing SHIFT switches the function between LAMP and HOLD). Pressing the LAMP button to activate or cancel LAMP function. There is no icon shown on the display screen when you activate or cancel LAMP function. Pressing the HOLD button locks and unlocks the keyboard. 17. RST button: This button is used to reset the microcomputer. In the unlikely instance of a function abnormality, press this button to reset the microcomputer. When pressed the remote control returns to initial factory settings. 18. FRESH/FOLLOW ME button: This button is a composite button. Pressing SHIFT switches the function between FRESH and FOLLOW ME. There is no icon shown on the display screen when the FRESH function is activated or cancelled. 19. C°/ F° button: This button is used to switch Fahrenheit and Celsius temperature display on the remote control. 22 USER MANUAL Split Wall-Mounted Air Conditioner TURBO OPERATION Pressing the TURBO button during COOLING or HEATING operation adjusts the air speed to HIGH. Pressing the TURBO button again cancels the TURBO operation. Note: During TURBO operation, the air speed cannot be changed. ADJUSTING LEFT/RIGHT AIR FLOW DIRECTION Methods 1: Manually adjust Adjust the direction by moving the left/right air flow fin by hand. Caution: Before adjusting fin direction, turn air conditioner off. Methods 2: Horizontal and vertical auto swing(three-dimensional air flow model) Adjust the direction by remote controller. Pressing the AIR FLOW button activates the left/right air flow fins in either the fixed or swinging functions. TIMER OPERATION Setting Automatic turn off timer Set the time for the unit to turn off and when the desired time is reached,the air conditioner will automatically stop. 1. During the operation of the air conditioner, press the TIMER button and the air conditioner will enter the timed switch-off mode. 2. Continually press the TIMER button to set the desired time for switching off the machine. The timer can adjust the power off time from 1-24 hours. Each press of the button, changes the turn off time in the following sequence: 1 * 2 * ........ * 24 * cancel (no indicator)* 1. 3. After the setting of the timed switch-off, the digits shown on the display screen will go down by 1 for every elapsed hour. The displayed digits indicate the remaining time prior to the timed switch-off. Setting Automatic turn on timer Set the time for the unit to turn on and when desired time is reached ,the air conditioner will automatically start. 1. When the air conditioner is in the standby mode, press the TIMER button and the air conditioner will enter the timed switch-on mode. 2. Continually press the TIMER button to set the desired time for switching on the machine. The timer can adjust the power off time from 1-24 hours. Each press of the button, changes the turn on time in the following sequence: 1 * 2 * ........ * 24 * cancel (no indicator)* 1. 3. After the setting of the timed switch-on, the digits shown on the display screen will go down by 1 for every elapsed hour. The displayed digits indicate the remaining time prior to the timed switch-on. Releasing procedure When the display screen shows "24 hours", press the TIMER button again to deactivate timed mode. SLEEP OPERATION Use this mode to reduce operation sound when sleeping,etc. Press the SLEEP button, the air flow sound from the indoor unit is decreased. Press the SLEEP button again can deactivate sleep mode. 23 USER MANUAL Split Wall-Mounted Air Conditioner NOTE: Use the sleep mode when you are going to bed. If this mode is used in the day,the capacity is reduced since the ambient temperature is too high.(COOL MODE). * During the cooling mode,the room temperature will be raised gradually by 20C(40F) higher than the setting after the machine begins to operate in the sleep mode. * During the heating mode,the room temperature will be dropped gradually 50C (90F)lower than the setting after the machine begins to operate in the sleeping mode. * REPLACEMENT OF BATTERIES * When the signal from the remote controller slid becomes weak and the indoor unit can not receive it properly;or the indicators on the slid et he ba ck cov er et he fro nt cov er display screen become blurred, remove the back cover of the remote and replace with two new batteries. * The positive and negative poles must Remote Controller 1 match the installation positions. * * CLK button New batteries of the same type have to be used within the remote. If the remote controller is not to be used for long time, remove the batteries to Remote Controller 3, 7, 8, 9 and 11 It does not work on this model. CLK RST RST button This button let computer reset. (push the RST button with the tip of a ball pen,etc) prevent them from leaking which may damage the controller. * If the remote controller is in an abnormal state, you can take out the batteries to clear and reset the display. Basic principles and performances Slide off the back Cover Remote Controller 2, 4, 5, 6 and 10 *Features of Heating Operations* * The unit absorbs heat from the outdoor air and transfer it indoors to heat the room. The heating capabilities of the heat pump go up/down with the increase/decrease of the outdoor air temperature. * The unit only needs a short time for the hot air circulation system to raise the room temperature. * When the outdoor air temperature is very low, the system can be used together with other heating devices. Good ventilation should be maintained to ensure safety and prevent accidents. Defrosting When the outdoor air temperature is very low and humidity is very high, frosting can occur on the heat exchanger of the outdoor unit, which can negatively impact the efficiency of the heating system. If this occurs, the automatic defrosting function will activate. The heating operation will be stopped for 5-10 minutes for defrosting to occur. * The fans of both the outdoor and indoor units are stopped. * During the defrosting, the outdoor unit might generate some steam. It is caused by fast defrosting, which is not a performance failure. * Upon the completion of the defrosting process, the heating operation is resumed. 24 USER MANUAL Split Wall-Mounted Air Conditioner *Maintenance* The air conditioner must be turned off and plug removed before the maintenance is to be carried out. Before the season of operation During the season of operation The cleaning of the air filter screen (Standard intervals should be once every two weeks). Check if there are no materials blocking the intake and outlet vents of the indoor and outdoor units. Remove the air filter screen from the unit. Gently press the two lower ends of the grid and open it. * Gently pull up the air filter screen and take it out in the direction of your body. * Check if the installation stand is corroded or rusty. Check if the machine is properly grounded. Clean the air filter screen. if the screen is very dirty, please use lukewarm water (about 30 C or 86°F) to clean it. Air it dry after the cleaning. Grounding terminal 0 Note: *Do not use boiling water to clean the screen. *Do not bake the screen dry over a fire. *Do not exert too much force in pulling and stretching the screen. Install the air filter screen. Check if the air filter is clean. Operating the air conditioner without the air filter screen will cause the interior of the Connect to the power source. machine to accumulate dirt which may lead to poor performance or damage to the unit. Clean the air conditioner Put batteries in the remote controller. * Use a soft and dry cloth to rub the air conditioner, or use a vacuum cleaner to clean it. * If the air conditioner is very dirty, use a piece of After the season of operation cloth and soak it with neutral home-use detergent to do the cleaning. Set the temperature at 30ºC or 86°F and operate in the FAN function for approximately half a day. To make the interior of the units dry Stop the operation of the machine and turn off the power switch. The air conditioner will consume about 5W of electric power after the machine is turned off. For the purpose of energy saving and safety, it is advisable to pull the plug out during the non-operational seasons. Clean and install the air filter screen. Note: If the air filter screen is blocked by dust or dirt, the performance of cooling and heating will be affected. This can include operation noise and increased power consumption. Please ensure the air filter screen is cleaned regularly. Clean the indoor and outdoor units. Take the batteries out from the remote controller. 25 USER MANUAL Split Wall-Mounted Air Conditioner *Service* Please check the following before requesting after-sale service from your dealer . The air conditioner does not operate at all . Is the power plug in an outlet ? Is the time set to "ON" position ? Is there a power failure or a blown fuse ? Poor cooling or heating performance . Is the room temperature setting suitable ? Are the window(s) and Are the air filters clean (Not clogged )? door(s) opened ? suitable TEMP Poor cooling performance . Is direct sunlight entering the room ? Is there a heat source Are there too many in the room ? people in the room ? Cases requiring immediate contact with the distributor Remove the power plug immediately and inform to your distributor in the following situations: Fuse or breaker often breaks off Power plug or cord is excessively hot. Covering of power plug or cord is broken . Remote does not activate unit. Abnormal noise is heard during operation Fuse often blow off Fuse often breaks off Malfunction is interfering with TV, radio or other devices . When faulty operation movement is observed after the RUN button is pressed; even after removing the power plug and restarting the operation after 3 minutes, faulty movement continues to occur. 3Minutes go by , but why 26 *Troubleshooting* The unit can not be restarted just after shut down . (RUN lamp is illuminated) Not operate USER MANUAL Split Wall-Mounted Air Conditioner Restart is stopped for 3 minutes after shut down to protect the unit . Please wait for 3 minutes . The three-minute protection timer incorporated in the microcomputer actuates automatically . Except when power is not connected, this function does not actuate . Air is not blown out at starting of heating operation. Air blow is stopped to prevent blowing out of cold air until the indoor heat exchanger is warmed .( 2 to 5 min ) ( HOT KEEP) The unit will not stop blowing out the air immediately after shut down at COOL operation(some models). The unit is undertaking a mould proofing operation and indoor fan motor runs at low speed .The louver will not close down until after 30 seconds. Air is not blown out for 6 to 12 min , at heating operation . When outdoor temperature is low and humidity is high , the unit sometimes performs defrosting automatically . Please wait . During defrosting, water or steam may appear from the outdoor unit . Air is not blown out during DEHUMIDIFY operation . Indoor fan is sometimes stopped to prevent vapor of dehumidified moisture and save energy . Mist is blown out during COOL operation . This phenomenon sometimes occurs when the temperature and humidity of the room are very high , but it will disappear as temperature and humidity are lowered. The unit is emitting an unusual smell. Air blown out during operation may smell . The smell of tobacco or cosmetics from the home can stick to the unit . A cracking sound is heard. This is caused by the refrigerant that is circulating inside the unit. A cracking sound is heard after a power stoppage or after disconnecting the power supply plug. This is caused by heat expansion or contraction of plastics. Operation can not be restarted even if the power is recovered. The memory circuit of the microcomputer is cleared. Operate the remote controller again to restart the operation . Remote control signals may not be received when signal receiver on the air conditioner body is exposed to direct sunlight or strong lighting. Ensure signal receiver is not in direct sunlight. Remote control signals are not being received by unit. Moisture may form on the air outlet grilles . If the unit is operated for a long period of time with the high humidity , moisture may form on the air outlet grilles and drip down . 27 Glen Dimplex Australia Pty Ltd Tel: Fax: Web: 1300 556 816 1800 058 900 www.xpelair.com.au 1/21 Lionel Road Mount Waverley VIC 3149