Transcript
TP-MS4x4 4 Port Gigabit PoE Injector
USER’S MANUAL
TYCON POWER SYSTEMS
User’s Manual
TP-MS4x4 V5
1. General Information The TP-MS4x4 is a DC/DC PoE (Power over Ethernet) Injector, provide up to 4 different voltage DC input and four different voltage PoE output, output power maximum 1A/port, data rate can be 10M/100M/1000M. The polarity of each PoE output can be reversed if you need to reverse the output polarity. This manual will help you to install and setting the PoE injector.
2. Hardware Description
4
3
2
1
Data in
4
3
2
1
Data + Power out
Front panel detail the port number is as the diagram shows.
Rear panel detail 2
TYCON POWER SYSTEMS
User’s Manual
TP-MS4x4 V5
*LED Indicator There are 4 LEDs on the front panel to indicate the input and output power status of each port.
LED
STATUS
1~4
Green
Description A valid power device is detected on this port. Active current is 80mA.
Red
No power device is detected on this port.
Off
No input power apply, or input source alarm. Alarm voltage is less than 58VDC, or larger than 10.5VDC. Alarm current is 2A.
*Data Input The upper ports 1-4 on the front panel are used for Gigabit Ethernet data input. All four ports with surge protection.
3
TYCON POWER SYSTEMS
User’s Manual
TP-MS4x4 V5
*Power Input The input voltage of TP-MS4x4 is 12VDC to 57VDC, it is common negative design, the green terminal (CON1) on rear panel is used for power input wiring, it can be connected to maximum 4 different sources with 4 different voltages, the jumper A, B, C, of JP1 on rear panel controls the input/output connection, its setting as below. (1=jumper on, 0=off) Jumper Input VIN1+ VIN1+
A
B
C
(1-2)
(1-3)
(1-4)
1
1
1
PoE 1/2/3/4=VIN1 (Factory setting)
1
1
0
VIN4+ VIN1+
PoE Output
PoE 1/2/3=VIN1 PoE 4=VIN4
1
0
1
PoE 1/2/4=VIN1
VIN3+
PoE 3=VIN3
VIN1+
PoE1/2=VIN1
VIN3+
1
0
0
VIN4+ VIN1+
PoE3=VIN3 PoE4=VIN4
0
1
1
PoE1/3/4=VIN1
VIN2+
PoE2=VIN2
VIN1+
PoE1/3=VIN1
VIN2+
0
1
0
PoE2=VIN2
VIN4+
PoE4=VIN4
VIN1+
PoE1/4=VIN1
VIN2+
0
0
1
PoE2=VIN2
VIN3+
PoE3=VIN3
VIN1+
PoE 1=VIN1
VIN2+
0
0
0
PoE 2=VIN2
VIN3+
PoE 3=VIN3
VIN4+
PoE 4=VIN4
4
TYCON POWER SYSTEMS
User’s Manual
TP-MS4x4 V5
*PoE Output The bottom ports 1-4 on the front panel are used for carry PoE output, the output voltage is the same as input, no regulated. Normally as detailed below: * Data pair A on line 1 and 2 * Data pair B on line 3 and 6 * Data pair C plus V+ on line 4 and 5 * Data pair D plus V- on line 7 and 8
*Output Polarity Reverse (for technician operation only) The TP-MS4x4 may deliver PoE output with reverse polarity. Just move related jumpers from pin 1-2 to pin 2-3, and then * Data pair C carry V- on line 4 and 5 * Data pair D carry V+ on line 7 and 8 Open the cover, the JP4~JP11 on the PCB responds for the output polarity of port 1~4, each two jumpers should be paired moved to ensure the path enough for the through current.
Control port
JP10 & JP11
JP8 & JP9
JP6 & JP7
JP4 & JP5
Port 1
Port 2
Port 3
Port 4
* Pin1-2(short pin1 & pin2): RJ45 pair C (pin4 & 5) carry PoE positive voltage. * Pin2-3(short pin2 & pin3): RJ45 pair C (pin4 & 5) carry PoE negative voltage.
5
TYCON POWER SYSTEMS
User’s Manual
TP-MS4x4 V5
4. Technical Information Data Rate
10M/100M/1000M
Input voltage:
12VDC to 57VDC
Maximum PoE power
Current limited – 1A/port
PoE protection
over-current, over/under voltage
LEDs:
Green-PD detect, Red-Power ready, Off-No power apply
Operating temperature
-40℃~ +75℃
Operation humidity
90% relative humidity, non-condensing
Storage temperature
-40℃~+85℃
Dimension
40mm(H) x118mm(W) x90mm(D) DIN RAIL Mountable
Surge protection on data input ports: Signal Operating Voltage
Data 5V
Clamping Voltage
Data 16.5V (@I PP =5A, t p =8/20µs, I/O pin to GND)
Peak Pulse Current
20A (tp=8/20µs)
Pin Protected
All 8 pin protected
Max. Shut Capacitance
IEC COMPATIBILITY (EN61000-4)
<3pF (VR = 0V, f = 1MHz, I/O pin to GND) < 1.5 pF (VR = 0V, f = 1MHz, Between I/O pins) IEC61000-4-2 (ESD) ±15kV (air), ±8kV (contact) IEC61000-4-4 (EFT) 40A (5/50ns) IEC61000-4-5 (Lightning) 20A (8/20µs)
6