Transcript
®
KELine® datasheet
UTP (U/UTP) cable 4x2x0,54, Category 6, 400 MHz, LSOH, Euroclass Eca P/N: KE400U23LSOH-Eca
1
Gigabit
Cat.6
400 MHz
features
LS0H
n
n
E ca
n n n
complies with the Construction Products Regulation (CPR) EU No. 305/2011 and reaction to fire requirements according to the harmonized standards EN 50575: 2014+A1: 2016 unshielded cable with pairs separated by a cross filler, halogen-free sheath enables transmission of all high-speed protocols including 1000BASE-T tested in bandwidth up to 400 MHz
not shielded against electromagnetic interference
application n n n
primary (Campus), secondary (Riser), tertiary (Horizontal) IEEE 802.3: 10BASE-T; 100BASE-TX; 1000BASE-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM
construction Conductor
bare copper wire, 0,54 mm
Twisting Cable lay up
2 cores to the pair 4 pairs to the core
Outer cable diameter
6 mm
Insulation
Sheath
polyethylene, Ø 0,95 mm
LSOH, gray RAL7035
reaction to fire and fire safety Reaction to fire Fire safety
Eca flame retardancy smoke performance halogen acidity
IEC 60332-1-2
IEC 61034-1, IEC 61034-2 IEC 60754-2
mechanical properties Min. bending radius Temperature range Max. tensile load Weight (netto)
installation operation
installation operation
100 N (10 kg)
36 kg / km
48 mm
24 mm 0 °C to +50 °C
-20 °C to +60 °C
®
KELine® datasheet
electrical properties at 20°C Conductor resistance
-
Resistance unbalance
≤ 176 Ω/ km ≤ 2%
Insulation resistance Capacity
(500V) at 800 Hz
≥ 5000 MΩ x km nom. 48 nF/ km
Characteristic impedance
at 100 MHz
(100 ± 5) Ω
Propagation delay
Nominal
535 ns/100 m
Test voltage
(DC, 1 min) core/core; core/screen
Capacity unbalance
(pair/ground)
Nominal velocity of propagation (NVP)
≤ 1500 pF/ km
-
Delay skew
cca 67%
Nominal
20 ns/100 m
1000 V
transmission properties at 20°C f (MHz)
Attenuation (dB/100m) 1,0
4,0
10,0 16,0 20,0 31,2 62,5
100,0 125,0 155,5 175,0 200,0 250,0
300,0 400,0
max. 2,1
3,8
6,0
7,6
8,5
10,7
15,5
19,9
22,5
25,4 27,1
29,2
33,0
nom.
1,9
3,8
6,0
7,6
8,5
10,7
15,1
19,1
21,3
23,8 25,3
27,0
32,0 36,1 41,7
NEXT (dB) min.
74
65
59
56
55
52
47
44
43
42
41
40
38
PS-NEXT (dB) nom.
78
69
63
60
59
56
51
48
47
45
44
44
42 41 39
min.
72
63
57
54
53
50
nom.
75
66
60
57
56
53
ACR (dB/100m) min.
72,0
61,2
53,0
48,4
46,5
41,3
nom.
76,1
65,2
57,0
52,3
50,0
45,0
PS-ACR (dB/100m) min.
nom.
min.
nom.
59,2
62,2
56
70
70,0
51,0
46,4
44,5
39,3
73,1
54,0
49,3
47,0
42,0
42
45
24,1
28,9
22,1
33,0 25,9
40
42
16,6
21,3
14,6
18,3
38 36
41
8,8
13,5
45
48
41
44
39
41
39 38 36
31,5
20,5
13,9
10,8
5,0
36,0
25,2
19,1
16,5
10,0 4,8 -2,7
ELFEXT (dB/100m)
29,5
18,5
22,2
11,9
16,1
2,0
7,0 1,8
-5,7
68
48
44
42
38
32
82
62
58
56
52
PS-ELFEXT (dB/100m) min.
65 53 45 41
39 35
40
29 25 23
37
20
46
28
42
24
38
21
36 34 32
19 17
26
23
22
20
30
nom.
80
68
60
56 54
50 44
40
38
36 35
34
32 30 28
Return loss (dB) min.
20,0 23,0 25,0 25,0 25,0 23,6 21,5 20,1 19,5 18,8 18,4 18,0 17,3
This product is certified on a component level by 3P international independent laboratories according to ISO/IEC 11801:2011 (Ed.2.2), IEC 61156-5(Ed.2) Amd.1, EN 50173-1:2011, EN 50288-6-1:2013, ANSI/TIA 568-C.2, IEC 60332-1-2, IEC 61034-1, IEC61034-2 Amd.1, IEC 60754-2. Mass production of this product is under permanent supervision of third party international laboratories performing 3P SURVEILLANCE maintenance testing and quality assurance sites The determination of Reaction to Fire Class Performance of this cable has been performed by Product Certification Body notified by European Commision.