Preview only show first 10 pages with watermark. For full document please download

V-500 Filter Cartridge - Pittsburgh Water Cooler

   EMBED


Share

Transcript

V-500 Filter Cartridge Delivers premium quality drinking water for bottleless coolers and drinking fountains APPLICATIONS Office water filtration Drinking water station filtration Hotel guest room water filtration FEATURES AND BENEFITS Reduces viruses up to 99.9999%. Reduces bacterial up to 99.99%. Reduces chlorine taste and odor and chloramines. Reduces dirt, rust and other particulates. Reduces parasitic protozoan cysts such as Giardia, Entamoeba, Cryptosporidium. Controls even extreme levels of common “off” tastes and odors, including those which are earthy, moldy and fishy. Reduces lead to below the Federal Action Level of 15 ppb. Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs). Sanitary cartridge replacement is simple, quick and clean. Internal filter parts are never exposed to handling or contamination. A special additive prevents lime scale build-up in water-using appliances*. NSF Certified under NSF/ANSI Standards 42 and 53 and NSF P231. *As tested by Everpure V-500 Filter Cartridge: EV9798-26 OPERATIONAL TIPS Before purchasing a water treatment unit, have the water tested to determine the actual treatment needs. Change cartridges on a regular 1 year preventative maintenance program. Change cartridges when capacity is reached or when flow becomes too slow. Always flush the filter cartridge at time of installation and cartridge change. Replace cartridges when capacity is reached or when flow becomes too slow, but at least annually. Everpure Drinking Water Systems are warranted to be free of defects for a full twelve (12) months after date of purchase. A detailed warranty statement is provided wtih each system. SPECIFICATIONS Flow Rate: Temperature: Pressure: Capacity: Controlled at 0.5 gpm (1.9 L/min) 35 – 100ºF (2 – 38ºC) Cold water use only. 25 – 80 psi (1.7 – 5.5 bar), non-shock 500 gallons (1893 L) Electrical Connection: None V-500 Filter Cartridge EV9798-26 INSTALLATION TIPS Install vertically so cartridge hangs down. Space required: 5 x 5 x 22 inches (13 x 13 x 56 cm). Allow 2-1/2" clearance below the cartridge for easy cartridge replacement. A separate drinking water faucet is required. CLAIMS & NOTES* This system has been tested according to NSF/ANSI 42/53 and Protocol P231 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53 and Protocol P231. *Tested using flow rate = 0.5 gpm; pressure = 60 ± 3 psig; pH = 7.5 ±0.5; temp. = 20° ±3°C Influent Challenge Concentration Substance Max. Permissible Product Water Concentration Reduction Requirements Average Reduction System Tested and Certified by NSF International against NSF/ANSI Standard 42–Aesthetic Effects Chlorine 2.0 mg/L ±10% Chloramine 3.0 mg/L ±10% Particulate, Class I particles 0.5 to <1 µm at least 10,000 particles/mL > 50% Standard 42 and 53 for the reduction of: 98.4% 0.5 mg/L 98.4% > 85% 99.9% 99.95% 99.99% Standard 53–Health Effects Turbidity† 11 ±1 NTU Cyst Minimum 50,000/L 0.5 NTU 99.1% Lead 8.5 0.15 mg/L ±10% 0.010 mg/L 99.3% Lead 6.5 0.15 mg/L ±10% 0.010 mg/L 99.4% Methyl tert-butyl ether 0.015 mg/L ±20% 0.005 mg/L 96.6% Chloroform (VOC surrogate chemical) 0.307 mg/L 0.015 mg/L 99.8% TTHM (as Chloroform) 0.45 mg/L ±20% 0.080 mg/L 92.3% † 2.8 x 107/100 mL > 99.9999% 7.43 log Virus MS-2 (ATCC-15597-B1) 4.3 x 104/mL > 99.99% 4.64 log Std. No. 53–Health effects Chemical Reduction Taste & Odor Chlorine Chloramine Mechanical Filtration Chemical Reduction Lead MTBE VOC TTHM Mechanical Filtration Cyst Turbidity Nominal Particulate Class I System is Certified by NSF International against NSF P231 - Microbiological Water Purifiers based on the recommendations set fourth in the USEPA Guide Standard and Protocol for Microbiological Water Purifiers (OPP Task Force Report, 1987). Protocol P231–Microbiological Water Purifiers Bacteria Raoultella terringena (ATCC-33257) Std. No. 42–Aesthetic effects NTU = Nephelometric Turbidity Units WARNING: This system is not intended to convert waste water or raw sewage into potable drinking water. Everpure-Shurflo India A-25 Mohan Co-operative Industrial Estate Mathura Road New Dehli, 110 044 INDIA TEL: 011.661.188.00 FAX: 011.661.188.22 EVERPURE reserves the right to update specifications, change prices, or make substitutions without notice. Everpure-Shurflo Southeast Asia 18 Boon Lay Way #04-110/111 TradeHub 21, 609966 SINGAPORE TEL: 65.6795.2213 FAX: 65.6795.2219 Visit our website at www.everpure.com Everpure-Shurflo China Everpure-Shurflo Japan Inc. 21F Cloud 9 Plaza, No 1118, Hashimoto MN Bldg. 7F West Yan’an Road, Changning District 3-25-1 Hashimoto, Midori-ku Shanghai, 200052 Sagamihara-Shi Kanagawa 252-0143 CHINA JAPAN TEL: 86.21.3211.4588 TEL: 81.(0)42.775.3011 FAX: 86.21.3211.4580 FAX: 81.(0)42.775.3015 Pentair Filtration Solutions, LLC World Headquarters-Everpure/Shurflo North and South America Sales 1040 Muirfield Dr. Hanover Park, Illinois 60133 USA TEL: 800.323.7873 (US only) TEL: 630.307.3000 FAX: 630.307.3030 Everpure-Shurflo Australia 2 Redwood Drive Notting Hill Victoria, 3168 AUSTRALIA TEL: 011.61.39.574.4000 FAX: 011.61.39.562.7237 Everpure-Shurflo Europe bvba . Industriepark Wolfstee Toekomstlaan 30 B-2200 Herentals BELGIUM TEL: +32.(0).14.283.500 FAX: +32.(0).14.283.505 EV9798-26 AU10