Transcript
SPECIFICATION
TYPE
DRIVERS
ColorCORE® 12w/m 4w/ft 94lm/w 24VDC CV IP50
COVER
Dimmable with a suitable driver. Constant Voltage Driver 24VDC · CV
CLEAR LOR 0.77
0.8in 20mm
0.8in 20mm
V20S KIT Installation Manual
OPAL LOR 0.54
COLOUR TEMPERATURE
P24-60-D10
0-10v
DIM to 1%
CE·UL
P24-90-D10
0-10v
DIM to 1%
CE·UL
P24-100-D10
0-10v
DIM to 1%
CE
P24-120-D10
0-10v
DIM to 1%
CE·UL
4500K Daylight horizon cool white
See full specifier guide for more detailed information.
V20S KIT
4000K Moonlight cool white
2050mm V20S Profile 4 pcs 2050mm V20S Cover 4 pcs 8m VectorFLEX Pair of End caps PowerFeed
3500K White
DALI, DMX & TRIAC Dimmingavailable. Please contact sales department.
ACCESSORIES
3000K Warm white 2700K Very warm white 2400K Sunset warm white
CHECK
INSTALLATION
VECA-CA150-R1
TURN OFF POWER! COUPER LE COURANT! STROM ABSHALTEN! CORTE CORRIENTE!
VectorFLEX End Feed 500mm tail
VECA-CA151-R1
VectorFLEX Linear Power Link
VECA-CA152-R1
VectorFLEX Linear Power Link 50mm
VECA-CA153-R1
VectorFLEX Linear Power Link 500mm
!
V20S-MB202-R1 V20S-MA520-R1
CLEAN HANDS
DO NOT TWIST
DO NOT PULL
DO NOT HAMMER OR SAW ON VECTORFLEX
CHECK THE WALL! VËRIFIER LE MUR! DIE WAND ÜBERPRÜFEN! COMPRUEBE LA PARED!
End Cap (pair)
STATIC CONTROL! CONTRÔLE STATIQUE! STATISCHE STEUERUNG! CONTROL ESTÁTICO!
Standard Mount
V20S-MA620-R1
Rotation Mount
lumino.lighting
MODEL NUMBERS
ESD PROTECTION
100 MM
DO NOT PUT PRESSURE ON THE LED CHIP
BENDING BREAKS CIRCUIT! MINIMUM BEND 100mm DIAMETER
1. Measure the length required and cut VectorFLEX.
2. Cut Profile and cover to length required.
3. Push Vector into Connector
SAFETY Use a 24VDC driver with overload and short-circuit protection. Rate drivers for at least 10% above load. USA & Canada: Use only with Class 2 power unit to UL1310 standard. Use only with maximum output 24V voltage Class 2 powerunit.
Hold the side of connector
DISCLAIMERS
Profile Length = VectorFLEX Length + 25mm(1in)
Damage will be caused by incorrect input voltage or short circuit. Ensure access and sufficient free moving air space around products and drivers. Products and power supply gear must not be live wired. Protect products from dust & paint during installation and use shielded pair of cables for dimming control signal if applicable.
50mm(2in) Increments
+
+
+
–
–
–
–
Plan for loads, driver locations, dimming and suitable cable prior to installing.
+
For technical assistance contact your local Lumino distributor.
Cover Length = Profile Length – 5mm(0.2in)
Permanent Locking
Use only with class 2 power unit to UL 1310 standard. Use only with maximum output 24VDC voltage Class 2 power unit. Installation must be carried out by qualified electrician. Electrical work to be conducted in accordance with local regulations. Power must be disconnected prior to installation work. Ensure free-moving air space around leds and drivers. Protect the leds from dust and paint during installation and use. Plan for loads, driver locations, cables sizes etc prior to installation.
4. Stick down VectorFELX
5. Put on cover and end caps
6. Connect with Driver
Leave gap 3mm(0.12in)
CONNECT
Shielded control pair required for dimming signal wires. Incorrect voltage, reverse polarity or short circuit will cause damage.
The information in this document is subject to change without notice
+
Check for latest specifications at www.lumino.lighting
–
Copyright © 2016 LUMINO E&OE
Junction Box
Peel off adhesive tape of VectorFLEX and stick it down to Profile. Leave gap 2.5mm(0.1in)
LUMINO Lumino House, Lovet Road Harlow, Essex CM19 5TB United Kingdom T +44 (0) 1279 635411 E
[email protected] DO NOT PUSH HARD ONTO LED CHIPS
CHECK POLARITY (+,–)
lumino.lighting
VECTOR WIRING GUIDE
VectorFLEX Standard wiring arrangement
Dimming with 0-10V dimmable driver
See guide for cable length
0-10v dimming signal input
<12W/m up to 8M
24VDC DRIVER
24VDC DRIVER
VectorFLEX
MAX CABLE LENGTH GUIDE
Dimming with 0-10V / DALI / DMX interface
0-10v / DALI / DMX dimming signal input
24VDC DRIVER
VectorFLEX
INTERFACE
VectorFLEX
24VDC power supply*
24 VDC Vector Length
Vector Current
Vector Power
0.3mm² 22AWG
0.8mm² 18AWG
1.3mm² 16AWG
2.0mm² 14AWG
1m / 3.3’ 2m / 6.6’ 3m / 9.8’ 4m / 13.1’ 5m / 16.4’ 6m / 19.7’ 7m / 22.9’ 8m / 26.2’
0.5A 1.0A 1.5A 2.0A 2.5A 3.0A 3.5A 4.0A
12 W 24 W 36 W 48 W 60 W 72 W 84 W 96 W
50m 33m 20m 13m 9m 5m 3m 1m
50m 50m 50m 43m 32m 25m 20m 15m
50m 50m 50m 50m 50m 45m 36m 30m
50m 50m 50m 50m 50m 50m 50m 50m
Use 24VDC drivers with overload and short-circuit protection. Rate drivers for at least 10% above load. USA & Canada: Use only with Class 2 power unit to UL1310 standard. Use only with maximum output 24VDC voltage Class 2 power unit.
EMI Emission
Installers must ensure EMI emissions do not exceed local regulated limits.
Installers must ensure voltage drop does not exceed 5%.
Shielded cables and ferrite coils can be used where applicable. Vector interconnector cables are 22AWG.
*Cable lengths are based on average resistance for typical copper cables. Cable characteristics may vary according to manufacturer, temperature, copper purity, connections etc.
Reduce max. cable lengths by 10% if dimming.
• Installation must be carried out by qualified electrician. • Electrical work to be conducted in accordance with local regulations. • Power must be disconnected prior to installation work. • Ensure free-moving air space around leds and drivers. • Protect the leds from dust and paint during installation and use. • Plan for loads, driver locations, cables sizes etc prior to installation. • Shielded control pair required for dimming signal wires.
Constant voltage LED drivers can have high inrush current at power-on. Driver inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistant problem an inrush suppressor may be required.
• Incorrect voltage, reverse polarity or short circuit will cause damage.
IMVFXS-R01
For further help regarding installation visit lumino.lighting
MAX LED LENGTH (EXCLUDING CABLE)
VectorFLEX TRIAC DIMMING TRIAC Driver
12W/m 3.7W/ft
P24-100-PH P24-200-PH
7m / 23‘ 14m / 46’
120VAC / 230VAC TRIAC leading-edge phase cutting dimmed supply
24VDC DRIVER
Max. total length (see table) continue up to max. cable and load limits VectorFLEX
VectorFLEX
up to 8m
up to 8m
0-10V DIMMING 0-10V Driver
12W/m 3.7W/ft
P24-60-D10 P24-100-D10 P24-120-D10 P24-200-D10
4m / 13‘ 7m / 23’ 8m / 26’ 14m / 46’
DALI DIMMING DALI Driver
12W/m 3.7W/ft
P24-100-DAL P24-200-DAL
7m / 23‘ 14m / 46’
IMVFXS-R01
0-10v dimming signal input Max. total length (see table) 24VDC DRIVER
continue up to max. cable and load limits VectorFLEX
VectorFLEX
up to 8m
up to 8m
DALI dimming signal input Max. total length (see table) 24VDC DRIVER
continue up to max. cable and load limits VectorFLEX
VectorFLEX
up to 8m
up to 8m
lumino.lighting/support