Preview only show first 10 pages with watermark. For full document please download

Variable Frequency Drive (vfd) Medium Voltage

   EMBED


Share

Transcript

Find this product online: elandcables.com | Cables & Accessories Mining, Drilling & Tunnelling Cable | Variable Frequency Drive (VFD) Medium Voltage Cable Variable Frequency Drive (VFD) Medium Voltage Cable Eland Product Group: A9VF APPLICATION CABLE STANDARDS Specially designed medium voltage power cable with high EMC protection for the use on frequency control for AC drives. Generally to IEC 60092-350, IEC 60092-354, BS EN/IEC 60332-1, BS EN/IEC 60332-3, BS EN/IEC 60331 CONSTRUCTION Phase Conductor Class 2 compacted or stranded conductor, copper according to BS EN 60228 (previously BS 6360) Conductor Screening Non-metallic extruded semi-conducting XLPE Insulation XLPE (Cross-Linked Polyethylene) Insulation Screening Non-metallic extruded semi-conducting XLPE Metallic Screen Over Each Core Copper tape Earthing Conductor Split-earth conductor. Laid in the interstices of phase conductors. Insulated or uninsulated available on request The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Eland Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed. CHARACTERISTICS Voltage Rating 8kV Test Voltage 15kV Temperature Rating 0°C to +90°C Sheath Colour Red Inner Covering Polyolefin Screen Copper/polyester tape (copper side in contact with copper .braid) Braid of copper wire ISSUE NO 01-03-2014 Sheath Polyolefin UK T 020 7241 8787 | F 020 7241 8700 | [email protected] | www.elandcables.com International T +44 20 7241 8740 | F +44 20 7241 8700 | [email protected] technicalspecification | 1 of 2 Find this product online: elandcables.com | Cables & Accessories Mining, Drilling & Tunnelling Cable | Variable Frequency Drive (VFD) Medium Voltage Cable DIMENSIONS ELAND PART NO. NO. OF CORES (POWER+ EARTH) A9VFD050 3+3 NOMINAL CROSS SECTIONAL AREA mm2 Phase Earth 50 16 NOMINAL THICKNESS NOMINAL OVERALL OF INSULATION DIAMETER mm mm 3.4 47 NOMINAL WEIGHT kg/km MINIMUM BEDING RADIUS mm 4060 300 Other sizes available on request CONDUCTORS NOMINAL CROSS SECTIONAL AREA mm2 MAXIMUM DC RESISTANCE OF CONDUCTOR AT 20ºC ohms/km 50 0.387 ISSUE NO 01-03-2014 ELECTRICAL CHARACTERISTICS NOMINAL CROSS SECTIONAL AREA mm2 CURRENT RATING AT 45ºC Amps 50 130 The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances. 2 of 2 | technicalspecification UK T 020 7241 8787 | F 020 7241 8700 | [email protected] | www.elandcables.com International T +44 20 7241 8740 | F +44 20 7241 8700 | [email protected]