Preview only show first 10 pages with watermark. For full document please download

Varicontrol-s

   EMBED


Share

Transcript

V R I CO N T R OL® MONITORING SOLUTIONS VariControl-S Environmental Monitoring System CONTROLLERS Various controllers are available depending on the number of the Pro version offers an even higher management function measuring points and type of sensors required. Additionally, for increased control of your IT surroundings. Description Pro Controller with 2 sensor ports (incl. 1 temperature sensor) Sensor Dry contact Camera Extension ports ports ports ports Article No. 2 MRM0001 Controller with 4 sensor ports 4 MRM0003 Controller with 8 sensor ports 8 MRM0010 Pro controller with 8 sensor and 4 extension ports √ 8 Pro controller with 8 sensor, 4 USB camera and 2 extension √ 8 4 4 MRM0010LS 2 MRM0011L ports Controller with 8 sensor and 20 dry contact ports 8 Pro controller with 8 sensor, 20 and 4 extension ports √ Controller with 8 sensor and 60 dry contact ports Pro controller with 8 sensor, 60 dry contact and 4 extension √ 20 8 20 8 60 8 60 MRM0020 4 MRM0020LS 4 MRM0030LS MRM0030 ports Extension controller with 16 dry contact sports Environmental Monitoring System 16 Extension controller with 8 sensor ports MRM0040* 8 MRM0041* GPRS modem for SMS alarm (only i.c.w. Pro controller) MRM0042 * Extension controller, only i.c.w. a controller with extension ports Organisations are becoming increasingly dependent on computer systems. A very high uptime is one of the primary requirements for an ICT infrastructure. Absolutely ideal is a computer system that is 100% available, running 24 hours MRM0011L - front MRM0011L- rear a day. Unfortunately, that ideal can never be achieved. 99% availability may sound impressive, but it still means that your system is down for an average of 15 min each day, which translates into almost 4 days a year. Malfunctions in your computer system and networks can bring your business operations to a standstill. The product range of Minkels includes a monitoring product line that supplements an under-exposed aspect of the uptime guarantee: the Minkels MRM0020LS - rear VariControl-S System. Position Sensor Autosense Standard Pro Position Standard Pro √ √ Guest login √ √ Advanced log filter √ THE SOLUTIONS the VariControl-S series. All products work in exactly the same way. Sensor Notification Wizard The Minkels VariControl-S system can monitor the direct The different versions are characterised by the number of ports. A E-mail alerts √ √ Modbus √ surroundings of your racks. Its efficient and modular structure distinction is hereby made between intelligent ports and so-called SNMP version 1 √ √ Multilanguage web interface √ makes it suitable for a single rack or a complete server room. dry contact ports. The intelligent ports are used for measuring SNMP Version 2c and 3 The Minkels VariControl-S system can of course be seamlessly temperature, humidity and airflow, for example. The dry contact ports, SNMP Traps √ √ integrated and managed with your existing Network on the other hand, are simple on/off contacts, which can be used for SMS alerts √* √** Management Software. Various products are available within various functions, including the readout of CRAC or UPS systems, or HTTPS (SSL) used as door contacts. √ Specific Pro sensors Standard Daisy chain temperature sensor √ Skype call alerts √ Extension controllers √ Telephone alerts √** USB GPRS modem √ Keep alive e-mail √ √ Universal USB camera √ Keep alive trap √ √ Pan/Tilt USB camera dome √ Network Time Protocol (NTP) √ √ 8 ports dry contact sensor ALARM Photo Log √ Virtual sensors In case of disasters, the appropriate persons can be notified Audio log √ in different ways: e-mail, SMS, Web interface and SNMP. In * I.c.w. an external e-mail to third party SMS gateway Floor plans √ this way, VariControl-S gives you peace of mind about the ** I.c.w. GSM modem Password security conditions in your computer and server rooms. Pro √ √ √ √ √ (80) SENSORS The plug-and-play sensors are automatically recognised by the system. All sensors are powered by All sensors are connected with a RJ 45 connector. If a registered sensor is removed, a report is the VariControl-S unit itself. No separate power supply is thus required for the sensors. generated. A number of commonly used sensors are specified below. Environmental sensors Security sensors MRM0101 TEMPERATURE SENSOR WITH FIXED CABLE (1 M) Measuring range: Resolution: Resolution Pro: Comments: -55°C to +75°C 1°C 0.5°C Fixed cable, length 1m MRM0102 TEMPERATURE SENSOR WITH FIXED CABLE (2.5 M) Measuring range: Resolution: Resolution Pro: Comments: -55°C to +75°C 1°C 0.5°C Fixed cable, length 2.5m MRM0117 MRM0126 MRM0109 AIRFLOW SENSOR Measuring range: On/Off Accessories: Network cable Comments: Maximum cable length 20m MRM0118 SMOKE DETECTOR WATER LEAKAGE DETECTION LOOP EXTENSION (3.3 M) Measuring range: Specifications: Measuring range: On/Off Specifications: -20°C +60°C Accessories: Accessories: Network cable Comments: Comments: Total length 10m. Sensor length 3.3m. Maximum distance sensor to controller 30m MRM0122 MRM0119 MRM0111 SIREN & FLASHING LIGHT On/Off Detection: Photoelectric Siren: 85db @ 3m Network cable Connection via sensor port or dry contact MRM0113 Measuring range: Specifications: Accessories: Comments: On/Off Siren: 100±3db@1m Flash: 400 X / min Network cable Maximum cable length 30m MRM0124 MRM0128 HUMIDITY AND TEMPERATURE SENSOR TEMPERATURE SENSOR TEMPERATURE SENSOR (DAISY CHAIN) DRY CONTACT SENSOR WITH FIXED CABLE (5 M) DRY CONTACT SENSOR WITH 8 PORTS MAGNETIC DOOR SWITCH Measuring range: -40°C to +75°C 0 to 100% RH Resolution: 1°C (temperature) 1% (humidity) Accessories: Network cable Comments: Maximum cable length 300m Measuring range: Resolution: Resolution Pro: Accessories: Comments: Measuring range: Resolution Pro: Accessories: Comments: Measuring range: On/Off Voltage in: 0 to 5 Volt Comments: Fixed cable, length 5m. Sensor port can be configurated as Normally Open or Normally Closed Measuring range: On/Off (8x) Accessories: Network cable Comments: Only i.c.w. with pro controller, maximum cable length 300m. Measuring range: On/Off Specifications: Normally Open; With magnet contact: Normally Closed Accessories: Assembly materials Comments: Fixed cable, length 4m Connection via sensor port or dry contact MRM0130 MRM0131 -55°C to +75°C 1°C 0.5°C Network cable Maximum cable length 300m -55°C to +75°C 1°C Network cable Only i.c.w. with pro controller, max. 8 sensors per sensor port, maximum total length 150m Security sensors MRM0110 MRM0105 MRM0125 MRM0127 MOTION DETECTOR (DAISY CHAIN) WATER LEAKAGE DETECTOR WITH FIXED CABLE (4.5 M) WATER LEAKAGE DETECTOR WITH FIXED CABLE (33 M) WATER LEAKAGE DETECTION LOOP (3.3 M) Measuring range: On/Off Specifications: -20°C +60°C Comments: Fixed cable, length 4.5m Measuring range: On/Off Specifications: -20°C +60°C Comments: Fixed cable, length 33m Measuring range: On/Off Comments: Maximum total length is 30m UNIVERSAL CAMERA (USB) Measuring range: On/Off Resolution: Specifications: Detection angle 60° Comments: Max distance: 3m Accessories: Network cable Comments: Max 10 sensors per sensor port Maximum cable length 1 sensor: 300m, Maximum cable length 10 sensors: 46m, Maximum cable length between sensors: > 6m DOME CAMERA WITH PAN/TILT CONTROL (USB) 320x240 or 640x480 Resolution: Only i.c.w. with pro controller Comments: with camera ports 320x240 or 640x480 Only i.c.w. with pro controller with camera ports Other sensors MRM0112 MRM0114 MRM0116 AC-VOLT DETECTOR SENSOR CONTROLLED RELAY 4-20MA SIGNAL CONVERTER Measuring range: On/Off Specifications: 50VAC to 250VAC Accessories: Network cable Comments: Maximum cable length is 300m Measuring range: On/Off Specifications: 220 VAC, 10A, fused Accessories: Network cable Comments: Maximum cable length is 30m Measuring range: +4 mA to +20 mA Accessories: Network cable Comments: Maximum cable length is 5m CONFIGURATION The system is easy to configure with the embedded web to an external system. Additionally, alarms are also visible on the interface. Use a web browser to log into the controller for quick web-interface and LED indicators on the physical controller. The Pro system setup and maintenance. The sensors are automatically controller moreover makes it possible to relay alarms via SMS if they recognised and set. Subsequently, an automatic list is created are combined with the GPRS modem. The camera images can be of the current measurement values and a log file. The Pro viewed live with the aid of the web-interface. A photo log file can be version also allows the addition of a floor plan and camera created if a sensor event or alarm is initiated, e.g., in case a door opens, images. All sensor settings can later be adjusted to the specific movement in the computer room or a temperature alarm. These situation, such as your own names, locations or alarm values, photos can be sent by email, while a local file is maintained on the and you can activate trending graphs. After configuring the controller. This gives you immediate insight into the local situation at sensors, you can set the alarms by linking the sensors to an a remote site. We are eager to advise you on the optimal monitoring alarm relay such as e-mail, SNMP traps or via a dry contact solution for your specific situation. MINKELS NETHERLANDS MINKELS FRANCE Eisenhowerweg 12 Bâtiment D2 P.O. Box 28 19 Bd. Georges Bidault 5460 AA Veghel 77183 Croissy Beaubourg t. +31 (0)413 311 100 t. +33 (0)164 61 61 91 [email protected] [email protected] MINKELS BELGIUM MINKELS INTERNATIONAL Vaartdijk 59 Eisenhowerweg 12 3018 Wijgmaal (Louvain) P.O. Box 28 t. +32 (0)16 44 2010 5460 AA Veghel [email protected] t. +31 (0)413 311 100 [email protected] MINKELS SWITZERLAND Riedstrasse 3-5 AGENCY USA CH -6330 Cham Uptime Technology Solutions t. +41 (0)41 748 4060 1630 North Main St. #333 [email protected] Walnut Creek, CA 94596 t. +1 925-783 4668 MINKELS UK Unit 4 AGENCY GERMANY M40 Industrial Centre In der Mühlweide 20 Blenheim Road 61130 Nidderau Cressex Business Park t. +49 (0) 173 6634 862 High Wycombe Bucks, HP12 3RS t. +44 (0)1494 451706 [email protected] A N A E G I D E C O M PA N Y WWW.MINKELS.COM VCL-S-BRV02-EN