Vcs 500m10

   EMBED


Share

Transcript

Specification VCS 500M10 Combination Wave Generator The combination wave generator type VCS 500M10 generates high voltage transients as required by IEC 61000-4-5, Surge Immunity Requirements. The same transients are used for surge testing as per ITU recommendations for telecom equipment. emc test equipment • IEC 61000-4-5 • ITI K44 recommendations VCS 500M10 Combination Wave Voltage (open circuit) Pulse front time Pulse time to half value Current (short-circuit) Pulse front time Pulse time to half value Polarity Event counter select Pulse counter Trigger Automatic Manual External CRO trigger Synchronization Pulse repetition rate 1.2/50µs – 8/20µs 500V – 10,000V ± 10% 1.2µs ± 30% 50µs ± 20% max. 5,000A ± 10% 8µs ± 20% 20µs ± 20% Positive/negative/alternating 1 – 30,000 or endless 1 – 1,000,000 Measurements Peak voltage Peak current Test Routines Serial interface Parallel interface Safety Safety circuit Warning lamp General data Automatic pulse release Single pulse release External pulse release 5V trigger signal for oscilloscope 0° - 360°, resolution 1° 12s - 999s depends on the voltage Output Direct Interface Via HV connector; Zi = 2Ω To connect external surge coupler 10,000V in the LCD display 5,000A in the LCD display Dimensions, weight Supply voltage Fuses Interfaces RS 232, baud rate 1200 - 19200 IEEE 488, address 1 - 30 Control input (24Vdc) Floating output contact 19“ / 6HU, approx. 35kg 115/230V +10/-15% 2 x T 2AT (230V) or 2 x T4AT (115V) RS 232 and IEEE 488 (GPIB) Coupling/Decoupling networks for ac/dc power lines CNI 503A16 CNI 503A18 CNI 503A19 CNI 503A20 CNV 501S4 CNV 503S9 CNV 503S10 CNV 503S11 CNV 503S12 3phase coupler for EFT and Surge; 3x440V/16A 3phase coupler for EFT and Surge; 3x440V/32A 3phase coupler for EFT and Surge; 3x440V/63A 3phase coupler for EFT and Surge; 3x440V/100A 1phase coupler for Surge only; 250V/16A 3phase coupler for Surge only; 3x440V/16A 3phase coupler for Surge only; 3x440V/32A 3phase coupler for Surge only; 3x440V/63A 3phase coupler for Surge only; 3x440V/100A US types are for 3x480V Coupling/Decoupling networks for signal/telecom lines Quick Start Immediate start; easy to use and fast User Test Routines Change Polarity after n pulses Change voltage after n pulses by ∆V Standard Test Routines IEC 61000-4-5 Level 1,000V IEC 61000-4-5 Level 2,000V IEC 61000-4-5 Level 4,000V Manual Standard Test Routine Service Service, setup, self test CNV 504S1 CNV 504S2 CNV 508S1 CNV 508S2 4 telecom lines as per fig. 12 IEC 61000-4-5 4 signal lines as per fig. 11 IEC 61000-4-5 8 telecom lines as per fig. 12 IEC 61000-4-5 8 signal lines as per fig. 11 IEC 61000-4-5 Pulsed Magnetic Field as per IEC 61000-4-9 Antenna MS 100 for up to 5,000A/m Design and technical data subject to change without notice. EM TEST AG Sternenhofstr. 15 CH-4153 Reinach Switzerland Tel: Fax: email: URL +41 (0)61 717 91 91 +41 (0)61 717 91 99 [email protected] http://www.emtest.com vcs500m10v104.doc 05.11.04 Page 2/2