Transcript
Door Station A
Door Station B
The design and specifications of this manual can be changed without notification to the user. All copyrights and interpretation rights are reserved to Evervue.
Door Station C
Door Station F
Door Station G
Basic instructions: 1. Check the contents of your order. To be able to set up a system, you must have at least the following: *One Door station *One Monitor *DPS Box (Power distributor Box) *Power Supply (PS-50 or PS-55)
2. Recommended wires are:
*14 gauge 2 conductor stranded wire. *CAT5 (MUST use a pair of wire for each conductor) Strip the ends of the wires about 1/3”. If using stranded wiresor CAT5, solder the ends to ensure a good connection. Do Not use wire nuts to connect wires(wire nuts are for power and solids wires).
good well twisted and soldered
wrong
4.1 Connect the wire to the right side of the DPS Box. Then connect the other end of that same wire to the green plug and then to the back of the monitor. Make sure that these wires do not twist too much, and that they are well isolated from each other.
5. Door Strike/Magnetic lock 5.1 Door Lock controlled by Dry Contact:
The unlock setting on monitor: 8010 - lock mode to 0 - Normally open 8011 - lock mode to 1 - Normally closed Connect one lock Remove jumper
1 2
ON
4.3. Plug in the power supply. Connect the terminal L and N to110 240V input. This can be hardwired, or you can connect a cable w ith a plug. If you have a PS-55, make sure that the voltage switch in the unit is set to 110V or 220V before turning ON (depending the country you live).
If you have a large system, it is not recommended to have the Door Station providing the power for the lock, so use a separate power supply for the door lock.
3. If multiple door stations and monitors are used, you can con nect them in series (daisy chain) or in parallel. 4. Connect the wire to the BUS connection on the Door Station ( 2 connections on the left ). Then connect the other end of that same wire to the left connectionon the DPS box.
4.2. Connect the Red Wire of the DPS Box to the Positive (24V) of the power supply, usually the V+ or the Red connection. The black wire should connect to the V- or the black connection of the power supply.
Connect two locks Remove jumper
DPS *Exit Button ( Magnetic lock only )
lock
*Exit Button ( Magnetic lock only )
lock 1
*Use Exit Bottom with magnetic lock only.
lock 2 Page 01
9. Showing video on multiple monitors: 5.2 Door Lock controlled with Internal Power - Door strike: Recommended only for 1 Door Station + 1 Monitor -The door lock is limited to 12V, 250mA -The Unlock Setting of monitor must be set to 0 (by default).
Jumper position in 1-2 Lock
You can have up to 3 or 4 monitors (depending on the distance) showing video when the door bell is pressed. Default setting is to one monitor showing video. On the monitor that you want to show video, press the “EntryVue” Logo, then press the screen for 3 seconds, and then enter the code 8006#.
10. Maximum distance: Wire used
6. Ensure to set the Dip Switches of the Door Stations and Monitors correctly. Refer to the next page.
7. Unlock Setting (set in monitor)
-You must connect the system correctly before programming the unlock setting. -It will be saved automatically, so you only need to set in onemonitor. 1. Press the “EntryVue” logo located on the bottom left of the screen. 2. Press the screen for 3 seconds,then select “Installer’s Menu .” 3. Then enter one of the following codes: 8021# : 1 second 8022# : 2 seconds 8023# : 3 seconds 8024# : 4 seconds 8025# : 5 seconds 8026# : 6 seconds 8027# : 7 seconds 8028# : 8 seconds 8029# : 9 seconds
Maximum distance between door station and monitor
CAT5 or CAT6
300 feet (100 meters)
18/2 speake wire (stranded,not shielded)
300 feet (100 meters)
14/2 speake wire (stranded,not shielded)
500 feet (150 meters)
Comment Use 1 pair for each conductor. Solder the ends of the pair together Solder connections together. Set voltage between 25-27 volt (can be adjusted on the power supply)
8.Innercall Feature;
There are 2 ways to set up the intercom function, and you need to decide which one you want during the set up. 1. You can call a specific monitor. This is the standard defau lt. 2. You can innercall up to 4 monitors. In this case, you need t o set all 4 monitors with the same dip switches and one of them needs to be set as “master”. The other 3 must be set as “slave” in the “Installer’ s Menu” (Press the “EntryVue” logo located on the bottom left of the sc reen). Page 02
VD-950 WIRING DIAGRAM AC Input POWER SUPPLY PS-50/PS55
DIP SWITCHES SETTINGS OF DOOR STATION: FIRST DOOR STATION
THIRD DOOR STATION
SECOND DOOR STATION
FOURTH DOOR STATION
Dip switches 3 and 4 are inactive, so set them OFF.
DIP SWITCHES SETTINGS OF MONITOR: 2 DPS
2
2 2
VD 950 Door Station
2
2
There are 6 Dip Switches in total,and each monitor MUST be set with the correct code. If daisy chain connection used,dip switch # 6 should be set ON only on the monitor is at the end of the line. If parallel connection used, all monitors should have the dip switch # 6 set ON.
MONITOR 1
MONITOR 9
MONITOR 2
MONITOR 10
MONITOR 3
MONITOR 11
MONITOR 4
MONITOR 12
MONITOR 5
MONITOR 13
MONITOR 6
MONITOR 14
MONITOR 7
MONITOR 15
MONITOR 8
MONITOR 16
For Door Station Model B, please refer to Dip Switches 17-32 on the next page. Page 03
If you have Door Station B, the monitors connected to the second button must be set with the following Dip Switches:
MONITOR 17
MONITOR 25
MONITOR 18
MONITOR 26
MONITOR 19
MONITOR 27
MONITOR 20
MONITOR 28
MONITOR 21 MONITOR 22 MONITOR 23 MONITOR 24
MONITOR 29 MONITOR 30 MONITOR 31 MONITOR 32
Door Station E and F - Settings Instructions:
* Use " * " to cancel, and "#" to confirm. * You should press "#” to confirm after inputting the code numb er each time, otherwise, the set up will be cancelled automatically in 10 seconds. *. Input the master code to switch the setting mode, and input the corresponding setting code to perform the function. After setting has been saved, input the next setting code to continue the set up. Press " * " at any time to exit the setting mode. * Each setting is indicated by the lighting of the LED indicators on the right side of the unit, and by the sound of the buzzer.
* When the registered code has been input on the keypad, the LED indicator (Group 1: red, group 2: blue) lights up, the buzzer s ounds, and the door strike/magnetic lock is unlocked. *User Group 1 codes are linked to the first lock, and User Group 2 codes are linked to the second lock. * If you make a mistake when inputting the user code, press “#” to cancel and input the user code again. * If 10 continuous incorrect access codes are attempted, the release function will be disabled for 60 seconds, the LED lights will stay on for 60 seconds, and the door station will beep 8 times. SETTINGS
SETTING RANGE
DEFAULT
SETTING CODE
1
Reset all settings
1,2,3,4
-
00
2
Setting the master code
1 – 12 digits Valid keys: 0 - 9
1, 2, 3, 4
01 02
3
Setting the lighting time
10 to 99 seconds
10 seconds
4
Setting the unlock time
1 – 99 seconds
1 second
03
5
Setting the unlock mode
Open
04
6
Keypad tone settings
On
05
7
Reset code settings
-
06
Normal
07
Enable
08
8
*and # settings
9
Call tone settings
0: Open 1: Closed 0: On 1: Off 1, 2, 3, 4 0: Normal 1: Reverse 0: Enable 1: Disable
Interference resistant grade settings Setting the code for Temporary 1
Valid Keys: 0 - 5
2
09
1 – 12 digits Valid Keys: 0 - 9
-
18
13
Setting the code for Temporary 2
1 – 12 digits Valid Keys: 0 - 9
-
19
14
Setting the code for User Group 1
-
20 – 59
15
Setting the code for User Group 2
-
60 - 99
10 12
1 – 12 digits Number of codes: 40 Valid Keys: 0 - 9 1 – 12 digits Number of codes: 40 Valid Keys: 0 - 9
Page 04
1.1.4 Delete all user cards:
Door Station G and H – Settings: 1. ID Card Registration: Introduction:
MASTER CARD
MASTER CARD
ADD
DELETE
*Up to 1000 user cards can be registered to the door station. *Easy management with LED status and sound hints. *There are two master cards, one MASTER CARD ADD, and one MASTER CARD DELETE. *Card reading distance is from 1 to 2 in (3 to 5 cm). *The master cards are necessary when you add or delete user cards. Please keep it for future use. 1.1 Add User Cards:
1.1.2 Control two locks:
1.3 Authorize Master Cards: When registering new master cards, the old ones will be deactivated automatically.
2. Unlock Setting: When holding the registered user card in front of the door statWhen holding the lock: red, the second lock: blue) lights up, the buzzer sounds, and the door strike/ magnetic lock will be unlocked. 1 Lock: Show the user card to the ID card window to release the lock, Red LED lights up; 2 Locks: Show the user card to the ID card window while in standby mode, the press the CALL button to release the second lock. Release the first lock
Release the second lock
Red LED lights up
Red LED lights up
1.2 Delete User Cards: 1.1.3 Delete User Cards: If 10 continuous unauthorized user cards are attempted, the release function will bedisabled for 60 seconds. If unauthorized user card is shown to the ID card window, the buzzer will beep 3 times. Page 06