Preview only show first 10 pages with watermark. For full document please download

Vector V12s - Designplan Lighting

   EMBED


Share

Transcript

Vector V12S 79 Trenton Avenue Frenchtown, NJ 08825 Tel: (908) 996-7710 Fax: (908) 996-7042 SPECIFIERS GUIDE Overview Vector V12S Key Features ≤ 1149lm/m 350lm/ft ≤ 13w/m 4w/ft Optimum performance in a 12.0 by 12.0mm (0.5in) profile with a single strip PCB using LEDs in White Spectrum™ or EQ™ performance grades. ≤ 88lm/w ≤ 88 CRI High output V12S-13 model gives up to 1149lm per metre (350lm/ft) output while V12S-07 model provides up to 634lm per metre (193lm/ft). 2600 - 5000K CCT Ideally suited to concealed lighting applications such as coving, uplighting, shelves, under ledges etc. IP67 version for wet locations with clear or opal cover. PowerTHRU Length increments of 100mm (4in) up to 2005mm (6ft 7in) with Click-Connect PowerTHRU connectors allowing longer light runs. Fixed mount or rotation mount allowing up to 90º rotation for light throw adjustment. IP50 CLICK-CONNECT 24VDC CV IP67 Specification Codes IP50 Type 03 06 09 12 LENGTH 12.01" (305 MM) 23.82" (605 MM) 35.63" (905 MM) 47.44" (1205 MM) POWER FEED C 150mm PowerTHRU D 150mm Single Feed G 500mm PowerTHRU H 500mm Single Feed V 1 2 S- C D D 2 0 -C 1 C C B LED CCT FINISH D E F SILVER WHITE BLACK COVER D E OPAL CLEAR C D F G H B E 2600K WS 2900K WS 3300K WS 3800K WS 5000K WS 2670-2870K EQ 3020-3220K EQ IP67 Type 03 06 09 12 LED CONNECTORS 1G 07 WM 1C 13 WM A B No Connectors CLICK-CONNECT POWER FEED C 150mm PowerTHRU D 150mm Single Feed G 500mm PowerTHRU H 500mm Single Feed LENGTH 12.01" (305 MM) 23.82" (605 MM) 35.63" (905 MM) 47.44" (1205 MM) V 1 2 S- I D D 2 0 -C 1 C C A LED CCT FINISH D E F SILVER WHITE BLACK COVER D E OPAL CLEAR C D F G H B E 2600K WS 2900K WS 3300K WS 3800K WS 5000K WS 2670-2870K EQ 3020-3220K EQ LED 1G 07 WM 1C 13 WM Applications V12S is ideally suited to exterior or interior spaces where diffused output is required. Clockwise from top: 1. Concealed handrail Imperial War Museum London 2. Exterior uplighting 8 Chifley Sydney 3. Underhelf lighting Corinthia Hotel London 4. Lift lighting 99 Bishopsgate London Application Guides Concealed Coving 5.91" (150) 5.91" (150) 5.91" (150) 5.91" (150) Illuminated Slots SolidEdge 5.91" (150) 3.15" (80) SolidEdge is Lumino’s unique plaster-board edging system. Designed for full compatibility with Vector V12S www.lumino.co.uk/products/solidedge Minimum recommended distances shown in mm Under Shelf 5.91" (150) 5.91" (150) Uplighter 5.91" (150) 5.91" (150) Bar-top Hand-rail 1.97" (50) Minimum recommended distances shown in mm Performance Performance Table 13W /m lumens1 /3.28' CCT V12S-13 lumens1 /w watts2 /3.28' CRI R9 2670 - 2870K 792 60 13.2 81 +31 2600K 852 65 13.2 88 +56 2900K 1047 79 13.2 60 -49 3300K 999 75 13.2 81 +30 3800K 1149 87 13.2 69 -17 5000K 1120 86 13.2 65 -53 1 Maximum total LED lumens per metre excluding LOR factor. 2 Power rated at 24vdc. Data @25°C Ta V12S-07 Performance Table 7W /m CCT lumens1 /3.28' lumens1 /w watts2 /3.28' CRI R9 2670 - 2870K 356 52 6.9 80 +31 2600K 472 68 7.0 88 +61 2900K 569 79 7.2 60 -49 3300K 588 83 7.0 67 -23 3800K 634 88 7.2 69 -17 5000K 680 97 7.0 63 -73 1 Maximum total LED lumens per metre excluding LOR factor. 2 Power rated at 24vdc. Data @25°C Ta Light output ratio LED 0.65 LOR 98º Opal diffuser 0.99 LOR 70º Clear diffuser 110º beam angle 3-Chip 5450 SMT package V12S-13: 0.66" (16.7mm) LED pitch V12S-07: 0.98" (25.0mm) LED pitch Photometric Data x 4.70 y 4.75 4.80 30° 0° 30° 120° 120° 90° 90° 4.15 2600K 4.10 45cd 2 SDCM 4.05 60° 60° C90° C0° 75cd 30° CIE 1931 X & Y Chromaticity hrs 10,000 30,000 30° 50,000 lm% ft 120 100 80 L70 60 40 0° Polar Distribution* fc 1.64 20 3.28 5 4.92 2 6.56 1 8.20 .8 49,500hrs 20 9.84 .6 dh dv Lumen maintenence* @25°C Ta Illuminance at a distance* Lumen output tests conducted by the National Physical Laboratory. Additional testing and photometric data conducted by independent UKAS accredited test laboratory, LUX-TSI. Test duration approx 17 minutes at ambient temperature of 25.2C with 24 hour burn-in time. Stabilisation period, approx. 45 minutes. Humidity <65%RH. Voltage 24.01VDC, current 0.145A. *Testing on production sample V12S 2600K 505mm 13w/3.28'. Mounting Fixed Mount 0.59" (15) 0.55" (14) V12S-MA520-R1 Fixing hole Ø0.16" (4.0mm) Rotation Mount 0.91" (23) 0.55" (14) 160° V12S-MA620-R1 Fixing hole Ø0.16" (4.0mm) Three mounts per metre average recommended End to end or corner alignments with connectors alongside Dimensions Standard lengths ~170g per metre 0.54" 0.47" 12.01" (305mm) 5.91" ~ 19.69" 23.82" (605mm) ~3.94"** 35.63" (905mm) 47.44" (1205mm)* 4.13" ~ 78.94" *Other lengths available on request. ~3.94"** 5.91" ~ 19.69" 0.89" 0.31" 0.31" Options & Accessories Powerfeed Options CLICK-CONNECT Powerfeeds for IP50 CB - 5.91" (150mm) WIRE PowerThru GB - 19.69" (500mm) WIRE PowerThru HB - 19.69" (500mm) WIRE Single CLICK-CONNECT 5.91" 5.91" 19.69" 19.69" 19.69" Extenders for IP50 VECA-CA025-R1 - 9.84" (250mm) 9.84" VECA-CA100-R1 - 39.37" (1000mm) 39.37" No Connector for IP67 GA - 19.7" (500mm) WIRE PowerThru HA - 19.7" (500mm) WIRE Single VECA-CA901-R1 Pair of 3M Scotchlok™ IDC sealant connectors providing effective moisture and water protection 0.60"x0.28"x0.28" (15.0 x 7.0 x 7.0 mm) 19.7" 19.7" 19.7" Drivers & Dimming Wiring V12S can be installed in power-through configuration lengths up to 19.7" (6 metres) subject to maximum cable size and length. Longer lengths can easily be achieved by running a parallel feed as shown in the 9m example below. Use only with maximum output 24 VDC voltage Class 2 power unit. 19.7" example 80W 24VDC 4.92' 4.92' 4.92' 4.92' 4.92' 4.92' 29.5" example 4.92' 4.92' 4.92' 4.92' 120W 24VDC Voltage V12S is rated to operate at 24VDC constant voltage. Its full operating range is 19.3 to 25.6 VDC. Startvoltage is defined as the voltage measured at the furthest cable point away from the driver. When calculating maximum cable size and length limits, installers must make their own checks to ensure that the minimum start voltage is correct as shown in the table below. V12S-13/07 Minimum start voltage V12S-13/07 Loading V12S Length min. start voltage V12S Length V12S-13 A V12S-07 A > 3.28' > 6.56' > 9.84' > 13.1' > 16.4' > 19.7' 20.3 VDC 20.6 VDC 21.1 VDC 21.8 VDC 22.8 VDC 23.9 VDC > 3.28' > 6.56' > 9.84' > 13.1' > 16.4' > 19.7' 0.55 1.10 1.65 2.20 2.75 3.30 0.30 0.60 0.90 1.20 1.50 1.80 24VDC Minimum start-voltage check point 1-10V / DALI / DMX V12S is ideally suited to dimming (via a PWM interface) with a 1-10V, DALI or DMX control signal. Maximum cable size and distance should be adjusted if using a dimming interface as shown in the wiring example tables. Typical PWM interfaces can handle 5A allowing a maximum of 29.5' (9m) of V12S-13 or 52.5' (16m) of V12S-07 per interface. Dimming Control 24VDC 59.25" Interface max. 6.56' Drivers Drivers must be of constant voltage type providing 24VDC power supply. Recommended minimum driver ratings are shown in the table above. It is recommended that only drivers with overload and short-circuit protection are used. Use only with maximum output 24 VDC voltage Class 2 power unit. Recommended minimum driver rating V12S Length V12S-13 A Driver VA V12S-07 A Driver VA >13.1' >19.7' >29.5' >39.4' >52.4' 2.2A 3.3A 5.0A 6.6A 8.8A 60W 80W 120W 160W 220W 1.2A 1.8A 2.7A 3.6A 4.8A 30W 45W 65W 90W 120W Installation Notes 24VDC power supplies and dimming interfaces are often tested and verified to be EMI compliant with secondary cable lengths of up to 32.8' (10m) (shorter lengths on some devices). For cable lengths exceeding 32.8' (10m), EMI emissions should be verified in the application. When EMI emissions exceed the allowed levels it may be possible to reduce them by using ferrite cores (not supplied). 24VDC cables should be shielded if longer than 32.8' (10m) total length. Recommended maximum cable lengths for dimmed circuits are based on a typi-cal dimming interface voltage drop of 0.3V. Installers should check the specific voltage drop of the interface they are using and adjust cable length accordingly. *Recommended cable lengths shown are based on average resistance for typical copper solid core cables. Cable characteristics may vary acording to manufacturer, temperature, copper purity, connections etc. Installers must make their own checks to ensure that the minimum start voltage is correct. The start-voltage check point is located at the furthest cable point from the driver. Wiring Examples V12S-13 Switched 40W 24VDC 59.25" 59.25" 265' max. [0.06in²] 80W 24VDC ~9.84' max. 78.94" 78.94" 9.84' max. [2.5mm²] 78.94" ~19.7" max. Cable size & maximum cable distance* V12S Length 0.02in² 20AWG 0.03in² 18AWG 0.04in² 17AWG 0.06in² 15AWG 0.1in² 13AWG >3.28' >6.56' >9.84' >13.1' >16.4' >19.7' 328' 157' 88' 49' 22' 3' 492' 236' 131' 72' 32' 3' 656' 315' 177' 98' 13' 3' 984' 472' 265' 147' 68' 6' 1640' 787' 442' 246' 114' 9' V12S-13 Dimmed Dimming Control 40W 24VDC 59.25" Interface 59.25" 236' max. [0.06in²] ~9.84' max. Dimming Control 80W 24VDC Interface 78.93" 78.93" 6.56' max. [0.1in²] 78.93" ~19.7' max. Cable size & maximum cable distance* V12S Length 0.02in² 20AWG 0.03in² 18AWG 0.04in² 17AWG 0.06in² 15AWG 0.1in² 13AWG >3' >6' >9' >13' >16' >19' 301' 137' 78' 42' 16' - 452' 206' 118' 62' 22' 3' 603' 275' 157' 85' 32' 3' 905' 413' 236' 124' 45' 3' 1509' 688' 393' 209' 78' 6' V12S-07 Switched 25W 24VDC 59.25" 472' max. [1.5mm²] 60W 24VDC 59.25" ~9.84' max. 78.93" 78.93" 13.1' max. [2.5mm²] 78.93" ~19.7' max. Cable size & maximum cable distance* V12S Length 0.02in² 20AWG 0.03in² 18AWG 0.04in² 17AWG 0.06in² 15AWG 0.1in² 13AWG >3' >6' >9' >13' >16' >19' 590' 282' 157' 91' 39' 3' 885' 423' 236' 134' 59' 3' 1181' 564' 314' 180' 78' 6' 1771' 846' 472' 272' 118' 6' 2952' 1410' 787' 452' 196' 13' V12S-07 Dimmed Dimming Control 25W 24VDC 59.25" Interface 275.59' max. [1.5mm²] 59.25" ~9.84' max. Dimming Control 60W 24VDC Interface 78.93" 78.93" 9.84' max. [2.5mm²] 78.93" ~19.69' max. Cable size & maximum cable distance* V12S Length 0.02in² 20AWG 0.03in² 18AWG 0.04in² 17AWG 0.06in² 15AWG 0.1in² 13AWG >3' >6' >9' >13' >16' >19' 551' 249' 137' 75' 26' 3' 826' 374' 206' 114' 42' 3' 1102' 498' 275' 150' 55' 3' 1653' 748' 413' 226' 82' 6' 2755' 1246' 688' 377' 137' 9' LED Specification White Spectrum™ LED Vector LEDs with White Spectrum™ technology benefit from ultra-fine LED x,y bining coordinates to precise specifications. Testing and control of these specifications gives very accurate control of correlated colour temperatures (CCT). White Spectrum™ technology also allows us to offer our high colour rendering index rating of 88 CRI (Ra) as standard for 2600K products. Each 2600K Vector LED is ultra-fine binned from a defined x, y range bin area covering approximately 2 MacAdam steps. This is far smaller than the ANSI C78.377A Standard which equates to 7 MacAdam steps. This binning accuracy equates to a colour temperature precision of less than 2.0% tolerance giving approximately +/- 50K. White Spectrum™ is one of the leading global LED technologies. A typical warm white fine-bin from other manufacturers is 40% larger than Lumino’s White Spectrum™ ultra-fine binning. VECTOR 2600K 2-step MacAdam 0.43 ANSI C78.377A 2700K 7-step MacAdam 0.39 0.41 0.43 26 00 K 280 0K 0.41 0.45 0.47 0.49 eQ™ LED To compliment Lumino’s White Spectrum ultra-fine bining, eQ™ offers wider binning within defined tolerances. eQ™ gives specifiers more choice and provides an economical solution where ultra-fine bining is not essential for a project. Available in 2670-2870K and 3020-3220K, eQ™ can be specified for V12S-13 and V12S-07. Technology Material specifications T6 6063 Aluminium extrusion PCB electroplated copper foil on FR4 substrate 22AWG wires stranded copper Operating environment Running Temperature (Tc): Ambient Temperature (Ta): Storage Temperature: Ingress Protection rating: Ave. 17°C above Ta -40 to +60°C -40 to +100°C IP50 / IP67 IP50 IP67 Certification Standards IEC 60598-2-4:1997 Luminairesused in conjuction with IEC 60598-1:2008 IEC 62031:2008 LED Modules for general lighting GOST R IEC 60598-2-4:1999 Luminaires used in conjuction with GOST R IEC 60598-1:2011 GOST R IEC 62031 EN55015: 2006+A1 :2007 EN61547: 1995+A1 :2000 Following the provisions of EMC Directive 2004/108/EC CB Testing Laboratory: Intertek Product Safety Laboratory (UK) UL Certified US/CA E364314 Low-voltage Lighting Systems, Power Units, Luminaires and Fittings Vector V12S 79 Trenton Avenue Frenchtown, NJ 08825 Tel: (908) 996-7710 Fax: (908) 996-7042 SG-V12S-R1406