Transcript
Vector V36I
SPECIFIERS GUIDE
Overview
Vector V36I Key Features IN-Ground Continuous Light Vector® V36I IPX8 IN-Ground profile IPX8 rated in-ground profile works with the V36G ground channel mounting system and incorporates a seamless edge-to-edge 8mm laminated OPX glass diffuser. V36I can be specified in standard or bespoke lengths and provides seamless linear joins for any required length. The invisible under-glass end cap design allows seamless long lengths in as many metres as required.
OPX™ Diffuser ≤ 3447 lumens/m 88 CRI max 2600 - 5000K CCT 7/13/26/40 WM 24VDC IPX8
The OPX™ diffuser in seamless edge-to-edge design is tuned specifically to provide consistent linear optical diffusion without imaging of individual LEDs. Available in power ratings from 7W per metre to 40W per metre and CCTs of 2600K, 2900K, 3300K, 3800K, 5000K along with static colours and RGB options. High output and the ability to combine up to three LED colour temperatures sideby-side makes V36I a highly versatile product. White Spectrum™ technology builtin, with standard length in 100mm increments from 110mm to 1010mm.
Vector V36I
Applications
V36I is IPX8 rated for exterior and wet locations.
Vector V36I
Performance
Performance Table 40W /m CCT
V36I-40
lumens1 /m
lumens1 /w
watts2 /m
CRI
R9
2670 - 2870K
2376
60
39.6
81
+31
2600K
2556
65
39.6
88
+56
2900K
3141
79
39.6
60
-49
3300K
2997
75
39.6
81
+30
3800K
3447
87
39.6
69
-17
5000K
3360
86
39.6
65
-53
PRE-PRODUCTION ESTIMATES 1
Maximum total LED lumens per metre excluding LOR factor.
2
Power rated at 24vdc. Data @25°C Ta
V36I-26
Performance Table 26W /m CCT
lumens1 /m
lumens1 /w
watts2 /m
CRI
R9
2670 - 2870K
1584
60
26.4
81
+31
2600K
1704
65
26.4
88
+56
2900K
2094
79
26.4
60
-49
3300K
1998
75
26.4
81
+30
3800K
2298
87
26.4
69
-17
5000K
2240
86
26.4
65
-53
PRE-PRODUCTION ESTIMATES 1
Maximum total LED lumens per metre excluding LOR factor.
2
Power rated at 24vdc. Data @25°C Ta
Light output ratio 0.40 LOR 110º beam angle
PRE-PRODUCTION ESTIMATES
Vector V36I
Performance
Performance Table 13W /m CCT
V36I-13
lumens1 /m
lumens1 /w
watts2 /m
CRI
R9
2670 - 2870K
792
60
13.2
81
+31
2600K
852
65
13.2
88
+56
2900K
1047
79
13.2
60
-49
3300K
999
75
13.2
81
+30
3800K
1149
87
13.2
69
-17
5000K
1120
86
13.2
65
-53
PRE-PRODUCTION ESTIMATES 1
Maximum total LED lumens per metre excluding LOR factor.
2
Power rated at 24vdc. Data @25°C Ta
V36I-07
Performance Table 7W /m CCT
lumens1 /m
lumens1 /w
watts2 /m
CRI
R9
2670 - 2870K
356
52
6.9
80
+31
2600K
472
68
7.0
88
+61
2900K
569
79
7.2
60
-49
3300K
588
83
7.0
67
-23
3800K
634
88
7.2
69
-17
5000K
680
97
7.0
63
-73
PRE-PRODUCTION ESTIMATES 1
Maximum total LED lumens per metre excluding LOR factor.
2
Power rated at 24vdc. Data @25°C Ta
LED 3-Chip 5450 SMT package 40W /m: 3 x 16.7mm pitch 13W /m: 1 x 16.7mm pitch
Vector V36I
26W /m: 2 x 16.7mm pitch 07W /m: 1 x 25.0mm pitch
Dimensions
Standard lengths
~100
210mm 510mm 610mm 1010mm CUSTOM*
~500
~1.4kg per metre
42
*custom lengths available on request.
XX10
36
~500
~100
70
SIDE
TOP
Vector V36I
Accessories
IP68 Cable Connection VECA-CA001-R1
IP68 KIT 1 - Cable Connection 4-Pole, 32A max @ 450V
VECA-CA002-R1
IP68 KIT 2 - Cable Termination with blanking blind-grommet
68 23
Mounting Accessories V36G-B2050-R1
V36G 2050mm Ground Channel for V36I
V36G-MB201-R1
V36G Ground Channel Spring Clips (10 pk)
V36G-MB202-R1
V36G Ground Channel End Cap Kit (pair)
V36G-JB203-R1
V36G Ground Channel Linear Joining Kit
V36I-MB204-R1
V36I Removal Tool
Vector V36I
Installation
V36G Ground Channel 48
For installation into solid floors, V36G ground channel must be used to provide a secure housing.
37
80
9
Supplied in 2m lengths, V36G can be cut and joined to suit, on-site.
Vector V36I
Installation
CLICK
Vector V36I
Drivers & Dimming
Wiring V36I-07/13 can be installed in power-through configuration lengths up to 6 metres subject to maximum cable size and length, V36I-26 is up to 3 meters and V36I-40 up to 2 metres Longer lengths can easily be achieved by running a parallel feed as shown in the 9m example below. Use only with maximum output 24 VDC voltage Class 2 power unit. 6m example 80W 24VDC
1.5m
1.5m
1.5m
1.5m
1.5m
1.5m
9m example 1.5m
1.5m
1.5m
1.5m
120W 24VDC
Voltage V36I is rated to operate at 24VDC constant voltage. Its full operating range is 19.3 to 25.6 VDC. Start-voltage is defined as the voltage measured at the furthest cable point away from the driver. When calculating maximum cable size and length limits, installers must make their own checks to ensure that the minimum start voltage is correct as shown in the table below. V36-40/26/13/07 min. start voltage
V36-40/26/13/07 Loading
V36 Length
min. start voltage
V36S Length
V36-40 A
V36-26 A
V36-13 A
V36-07 A
> 1m > 2m > 3m > 4m > 5m > 6m
20.3 VDC 20.6 VDC 21.1 VDC 21.8 VDC 22.8 VDC 23.9 VDC
>1m >2m >3m >4m >5m >6m
1.65 3.30 4.95 6.60 8.25 9.90
1.10 2.20 3.30 4.40 5.50 6.60
0.55 1.10 1.65 2.20 2.75 3.30
0.30 0.60 0.90 1.20 1.50 1.80
24VDC Minimum start-voltage check point
Vector V36I
1-10V / DALI / DMX V36I is ideally suited to dimming (via a PWM interface) with a 1-10V, DALI or DMX control signal. Maximum cable size and distance should be adjusted if using a dimming interface as shown in the wiring example tables. Typical PWM interfaces can handle 5A allowing a maximum of 9m of V36I-13 or 16m of V36I-07 per interface. Dimming Control
24VDC
Interface
max. 2m
Drivers Drivers must be of constant voltage type providing 24VDC power supply. Recommended minimum driver ratings are shown in the table above. It is recommended that only drivers with overload and short-circuit protection are used. Use only with maximum output 24 VDC voltage Class 2 power unit. Recommended minimum driver rating V36 Length*
V36-40 A
Driver VA
V36-26 A
Driver VA
V36-13 A
Driver VA
V36-07 A
Driver VA
>4m >6m >9m >12m >16m
6.6A 9.9A 15.0A 19.8A 26.4A
180W 240W 360W 480W 660W
4.4A 6.6A 10.0A 13.2A 17.6A
120W 160W 240W 320W 440W
2.2A 3.3A 5.0A 6.6A 8.8A
60W 80W 120W 160W 220W
1.2A 1.8A 2.7A 3.6A 4.8A
30W 45W 65W 90W 120W
*Parallel wiring where applicable.
Installation Notes 24VDC power supplies and dimming interfaces are often tested and verified to be EMI compliant with secondary cable lengths of up to 10m (shorter lengths on some devices). For cable lengths exceeding 10m, EMI emissions should be verified in the application. When EMI emissions exceed the allowed levels it may be possible to reduce them by using ferrite cores (not supplied). 24VDC cables should be shielded if longer than 10m total length. Recommended maximum cable lengths for dimmed circuits are based on a typical dimming interface voltage drop of 0.3V. Installers should check the specific voltage drop of the interface they are using and adjust cable length accordingly. *Recommended cable lengths shown are based on average resistance for typical copper solid core cables. Cable characteristics may vary acording to manufacturer, temperature, copper purity, connections etc. Installers must make their own checks to ensure that the minimum start voltage is correct. The start-voltage check point is located at the furthest cable point from the driver.
Vector V36I
Wiring Examples
V36I-13 Switched 40W 24VDC
1505mm 81m max. [1.5mm²]
80W 24VDC
1505mm ~3m max.
2005mm
2005mm
3m max. [2.5mm²]
2005mm
~6m max.
Cable size & maximum cable distance* V36 Length
0.5mm² 20AWG
0.75mm² 18AWG
1.0mm² 17AWG
1.5mm² 15AWG
2.5mm² 13AWG
>1m >2m >3m >4m >5m >6m
100m 48m 27m 15m 7m 1m
150m 72m 40m 22m 10m 1m
200m 96m 54m 30m 14m 1m
300m 144m 81m 45m 21m 2m
500m 240m 135m 75m 35m 3m
V36I-13 Dimmed Dimming Control
40W 24VDC
1505mm
Interface
72m max. [1.5mm²]
1505mm ~3m max.
Dimming Control
80W 24VDC
Interface
2005mm
2005mm
2m max. [2.5mm²]
2005mm
~6m max.
Cable size & maximum cable distance* V36 Length
0.5mm² 20AWG
0.75mm² 18AWG
1.0mm² 17AWG
1.5mm² 15AWG
2.5mm² 13AWG
>1m >2m >3m >4m >5m >6m
92m 42m 24m 13m 5m -
138m 63m 36m 19m 7m 1m
184m 84m 48m 26m 10m 1m
276m 126m 72m 38m 14m 1m
460m 210m 120m 64m 24m 2m
Vector V36I
V36I-07 Switched 25W 24VDC
1505mm 144m max. [1.5mm²]
60W 24VDC
1505mm ~3m max.
2005mm
2005mm
4m max. [2.5mm²]
2005mm
~6m max.
Cable size & maximum cable distance* V36 Length
0.5mm² 20AWG
0.75mm² 18AWG
1.0mm² 17AWG
1.5mm² 15AWG
2.5mm² 13AWG
>1m >2m >3m >4m >5m >6m
180m 86m 48m 28m 12m 1m
270m 129m 72m 41m 18m 1m
360m 172m 96m 55m 24m 2m
540m 258m 144m 83m 36m 2m
900m 430m 240m 138m 60m 4m
V36I-07 Dimmed Dimming Control
25W 24VDC
1505mm
Interface
84m max. [1.5mm²]
1505mm ~3m max.
Dimming Control
60W 24VDC
Interface
2005mm
2005mm
3m max. [2.5mm²]
2005mm
~6m max.
Cable size & maximum cable distance*
Vector V36I
V36 Length
0.5mm² 20AWG
0.75mm² 18AWG
1.0mm² 17AWG
1.5mm² 15AWG
2.5mm² 13AWG
>1m >2m >3m >4m >5m >6m
168m 76m 42m 23m 8m 1m
252m 114m 63m 35m 13m 1m
336m 152m 84m 46m 17m 1m
504m 228m 126m 69m 25m 2m
840m 380m 210m 115m 42m 3m
LED Specification
White Spectrum™ LED Vector LEDs with White Spectrum™ technology benefit from ultra-fine LED x,y bining coordinates to precise specifications. Testing and control of these specifications gives very accurate control of correlated colour temperatures (CCT). White Spectrum™ technology also allows us to offer our high colour rendering index rating of 88 CRI (Ra) as standard for 2600K products. Each 2600K Vector LED is ultra-fine binned from a defined x, y range bin area covering approximately 2 MacAdam steps. This is far smaller than the ANSI C78.377A Standard which equates to 7 MacAdam steps. This binning accuracy equates to a colour temperature precision of less than 2.0% tolerance giving approximately +/- 50K. White Spectrum™ is one of the leading global LED technologies. A typical warm white fine-bin from another manufacturer is typically at least 40% larger than Lumino’s White Spectrum™ ultra-fine binning.
VECTOR 2600K 2-step MacAdam
0.43
ANSI C78.377A 2700K 7-step MacAdam
0.39
0.41
0.43
26
280
00
K
0K
0.41
0.45
0.47
0.49
eQ™ LED To compliment Lumino’s White Spectrum ultra-fine bining, eQ™ offers wider binning within defined tolerances. eQ™ gives specifiers more choice and provides an economical solution where ultra-fine bining is not essential for a project. Available in 2670-2870K and 3020-3220K, eQ™.
Vector V36I
Specification Codes
Code Configuration V36I can be custom configured to suit the exact requirements of your project. Length, CCT, power, wires and connector type can all be specified as shown below.
V 3 6 I - J G F 1 0 1 0 -C 1 C K A LED CCT C D F G H B E
2600K WS 2900K WS 3300K WS 3800K WS 5000K WS 2670-2870K EQ 3020-3220K EQ
TOTAL LENGTH
LED POWER
02 05 06 10
1G 1C 2C 3C
210MM 510MM 610MM 1010MM
07 WM 13 WM 26 WM 40 WM
Swimming Pools Note, the standard powder-coat finish is not intended for chlorinated water or salt water use. Contact Lumino for advice on chemically-resistant coating options.
Vector V36I
Technology
Material specifications T6 6063 Aluminium extrusion with silver RAL9006 coating [contact us for other finishes] OPX™ Glass - EVA laminated 8mm low-iron PCB electroplated copper foil on FR4 substrate Xtra-Guard® 2 cables
Operating environment Running Temperature (Tc): Ambient Temperature (Ta): Storage Temperature: Ingress Protection rating:
Ave. 17°C above Ta -40 to +60°C -40 to +100°C IPX8
IPX8
Certification Standards Water Ingress - BS EN 60598-1:2008 IPX8 – test depth 1.3m for 72 hours High Temperature - BS EN 60068-2-2:2007 Test Bb 24 hours @ +60°C IEC 60598-1:2008 IEC 62031:2008 LED Modules for general lighting EN55015: 2006+A1 :2007 EN61547: 1995+A1 :2000 Following the provisions of EMC Directive 2004/108/EC
Testing Laboratories: PARC Test, Nemko Laboratory (UK)
Vector V36I
The information in this document is subject to change without notice Check for latest specifications at www.lumino.co.uk Copyright © 2014 Lumino Limited E&OE
Vector V36I
Vector V36I
Lumino Limited Lumino House, Lovet Road Harlow, Essex CM19 5TB United Kingdom T +44 (0) 1279 635411 E
[email protected]
www.lumino.co.uk
SG-V36I-WHI-R1403