Transcript
Vehicle Generators
High Performance
Emergency Services
Extremely Quiet Water-Cooled Compact Broadcasting
Light
Events & Tradeshows
Mobile Homes
Railways
Commercial Marine
Power Systems for Mobile and Stationary Applications
Panda Vehicle Generators
Mobile and Stationary Applications
Fischer Panda GmbH manufactures compact and quiet diesel generators for marine and vehicle applications. These are sold in over sixty countries worldwide under the trade name “Fischer Panda.”
Developed for use in special and diverse areas of the vehicle industry, Fischer Panda generators can be found supplying power to a vast range of applications worldwide.
Recreational & Touring
The company, based in Paderborn-Germany, was originally founded in 1977 under the name Icemaster GmbH and renamed to Fischer Panda GmbH in 2007.
Motorized RVs Expedition Vehicles Mobile Homes
The water-cooled diesel generators from Fischer Panda are renowned worldwide for being innovative, reliable and extremely quiet. The product range includes over two hundred different generators and covers a performance range from 2.5 kW to 200 kW.
Luxury Motor Coaches Limousine Coaches Holiday Homes
Fischer Panda generators feature an effective water-cooling system and a lightweight compact construction. This ensures Fischer Panda generators are the No. 1 in Europe for mobile super-silent diesel generators. These highly-proven marine and vehicle generators supply power to on-board electrical systems, electric drives and complete mobile energy systems.
Mobile Broadcasting & Communications Mobile Stages Trade Show Vehicles
Communications & Promotion
Formula 1 Team Vehicles Border Control & Customs Commercial Vehicles
Emergency & Specialist Services Emergency Command Centres Police / Ambulance / Fire -Fighting Mobile Blood Donor Units
Easy to operate
Compact Construction
100% Water-cooling
Sound Insulation
Environmental Monitoring Railway & Track Maintenance Tactical Shelters
Efficient Diesel Engines
Fischer Panda generators can be found installed in the smallest and tightest places onboard. Simple to maintain
2
Preinstalled connections
Power - just like at home
3
Compact, Quiet Vehicle Generators The most significant advantage of the Fischer Panda generator is the very low sound level. There are many components required to work together to achieve this result. As no cooling air flow inside of the capsule is required, this also ensures that ambient temperatures remain constant. An efficient watercooling system requires that the radiator be installed separately from the generator.
Vehicle Installation - roof-mounted radiator The radiator must be installed where good access for fresh air circulation is guaranteed. The best location is horizontally on the roof of the vehicle. The radiator has an integrated expansion tank.
Roof-mounted radiator with integrated expansion tank
Panda Generator
Vehicle Installation - side-mounted radiator A radiator can be fitted to the vehicle‘s side if there is no room on the roof.
Less space required for installation Water-cooled winding Can be installed anywhere onboard Hermetically sealed capsule All connections prefitted on capsule
Modular design ensures installation flexibility No appreciable warming of the installation area Super-silent sound insulation system Water-cooled silencer (up to 25 kW) No cooling air circulating within capsule
Expansion tank (optional) Side-mounted radiator
Super-Silent Sound Insulation System Fischer Panda generators up to 25 kW are delivered with a GFK sound insulation capsule with “3D” sound insulation material as standard (optional: sound insulation material “4DS”). From 30 kW, the capsule is delivered as a stainless steel-version MPL. The MPL sound insulation casing can be split up and consists of 6 - 11 parts, depending on the size of the generator. The MPL capsules are also available at an extra cost for generators from 6 kW to 25 kW. Different versions of sound insulation material are available: 3D 3 layers, up to 25 mm thick 4DS up to 5 layers, up to 40 mm thick 6DS up to 6 layers, up to 60 mm thick
Water-cooled Exhaust Silencer PVMV-N, PVK-U and PVK-UK generators (up to 25 kW) are fitted with a water-cooled exhaust silencer.
Panda Generator
Vehicle Installation - underneath chassis It may be possible to mount a radiator under the chassis if it is not possible to mount the radiator on the roof or the vehicle‘s side. Note: Sufficient clearance must be available to allow the air to circulate correctly so that warm air does flow back over the radiator.
Expansion tank
Radiator mounted underneath vehicle Panda Generator
water-cooled pre-silencer hot exhaust gases
main silencer cooled exhaust gases
4
Marine Installation - keel cooling An interesting alternative to seawater cooling for marine vessels is using a Fischer Panda vehicle generator in conjuction with a keel cooler. This eliminates the need for raw water pumps, strainers and an inboard heat exchanger.
Expansion tank
Panda Generator
5
Reliable
High Performance Windings
All the benefits of the Asynchronous Generator and more....
Available in three different versions:
230 V - 50 Hz AC or 120 V / 240 V - 60 Hz The HP1 is the standard version for 230 Volt 50 Hz ( 120 / 240 V - 60 Hz) AC. This is available up to 25 kW. From 12 kW, a three phase version should be considered, as the Panda generator permits dissymmetrical loads up to 50% per phase. A check should always be made as to whether a DC-AC Power System would be the better solution for small to middle ranged power systems. (See DC-AC Power System)
High protection rating High control precision No rotating coils No diodes No signal noise Highly efficient
lighting
satellite receivers
boilers
ventilators
air conditioners
ovens
compressors
electric motors
lighting
satellite receivers
Single Phase
Single Phase - HP1
Water-cooled Overload protection Short-circuit stability
The Panda offers all the advantages of the classic asynchronous generator and with the patented Voltage Control System (VCS), produces control precision that cannot be beaten by a conventional synchronous generator. The excellent qualities of the conOverload trolled Panda asynchronous generator have been impressively proven in many tests over the past years.
Water-cooled Protection
The asynchronous generator has always set high standards with regard to operational security and its lifespan. Therefore, the asynchronous generator is often the compulsory choice where a high degree of safety and reliability is demanded. This is of particular importance for professional applications, emergency services and technical response units. Fischer Panda even warrants the rotor with a lifetime guarantee - the rotor is often the most sensitive part of other generator systems. As the components which produce the most heat are located on the stator, the asynchronous generator continues to be the best suited for water-cooling. The electrical generator is warranted with a 5 year guarantee against corrosion.
Monitoring and Operation The generator switches itself off when any of these functions are not in the normal state. The standard remote control panel can be upgraded with a additional automatic module to enable the generator to be started (and stopped) by external devices such as timers etc.
The 400 Volt three phase winding has the highest level of efficiency and the best qualities. Also, this winding can supply single phase AC with the appropriate phase distribution. This enables each phase to be overloaded by up to 50 %. A three-phase generator should always be chosen above 25 kW (from Panda 30 NE). Dual Voltage System (DVS)
Combined unit with single and three phase windings The “DVS” Combi-Winding is a special version for 50 Hz generators consisting of two separate coils without additional costs. A 400 Volt three-phase winding is combined with a one phase winding. This permits the use of three phase motors (i.e. compressors for air conditioners and power tools etc). The separate one phase winding can supply the full nominal performance of the generator without “dissymmetrical load problems” to a phase, which simplifies the electrical installation.
air conditioners
ovens
Note: Generators with a DVS winding supply approximately 85% of the nominal performance compared with the HP1 or HP3 windings.
Single Phase + Three Phase
400 V - 50 Hz AC or 208 V - 60 Hz AC
Three Phase
Three Phase - HP3
Brushless Perfect sine wave Highest operating protection Patented VCS Voltage Control System
Dual Volta Syste ge (DVS) m - only from Fische r Pand a
Extremely Clean Sine Wave Remote Control Panel P4 Plus
The standard version remote control panel (from Panda 6000 ND upwards) monitors the following 6 functions: Engine coolant temperature Engine exhaust temperature Engine oil pressure
Generator Control Panel
Battery charging 230 Volt AC Cooling water leak (optional)
The Panda asynchronous generator supplies a particularly clean sine wave and achieves the best result from numerous tests in this category. This guarantees the smooth running of electronic devices such as air conditioners, charging devices, etc.
The outstanding sine wave of the Fischer Panda generator
Tolerance of ±3V with patented Voltage Control System The Fischer Panda Voltage Control System (VCS) has been used for more than ten years to regulate the generator and engine. The engine speed is progressively adjusted which ensuring that the voltage of the asynchronous generator has a tolerance of ± 3 volts. The Fischer Panda generator combines all the advantages of the asynchronous generator with the voltage control of a synchronous generator.
(for Panda Generator 6000ND and above)
6
7
Complete Program - AC and DC Generators Professional solutions for all recreational and commercial power applications
DC Generators for battery charging and power circuits onboard
AC Generators for supplying standard power circuits onboard
AC direct
Fischer Panda has a wide range of generator types for use in mobile power applications: 1. Panda Asynchronous Generators (PSA and PSA-HD), which directly produce alternating current (AC) whilst running. These generators are ideal if your power is required in continuous operation. 2. Permanent Magnet Generators (AGT-DDC) produce direct current (DC) and function as part of a DC Hybrid Power System. A battery bank is used with an inverter within this system to supply the power circuit onboard. The level of the batteries can be monitored and the batteries can be automatically charged by an AGT Generator. This system is optimal if your power is required in interval operation throughout the day.
AC indirect
3000 rpm - The ideal speed for powering up to 30 kW Low frequencies contain more energy and their energy-rich vibrations are transmitted to all components within the surrounding area. You will “notice” the generator throughout the whole vehicle. A correctly installed 3000 rpm generator that is housed within an insulation capsule is quieter than a slow-runner (often the opposite is presumed).
Less: Weight Fuel Consumption Reduced: Dimensions Purchase Price
Generators running at 1500 rpm are heavier and larger than their counterparts operating at 3000 rpm. As weight and space play such an important role in modern vehicle constructions, the smaller generator with 3000 rpm has considerable advantages. The high reliability and longer lifespan of a slow-runner is not always an important aspect, because the modern diesel engine operates within its ideal speed range. This is closer to 3000 / 3600 revolutions per minute than 1500 / 1800. As a result of their effective water-cooling, even at higher surrounding temperatures, Panda generators can be up to 20% more efficient than other units of a comparable size. Your individual application and installation requirements should be considered in each case. 3000 / 3600 rpm = Panda PSA 1500 / 1800 rpm = Panda PSA-HD
Hybrid Power Systems The Fischer Panda innovative and integrated energy systems provide on-board power for vehicles and marine vessels without the requirement to have a permanently running generator.
d ance r v d A o erat T) Gen (AG y g nolo Tech from a only and P r e Fisch
8
The extremely robust AGT generators have proven their reliability under extremely adverse conditions. Problems concerning empty batteries and independent power supplies are impressively solved using this Fischer Panda technology. The 75 lifeboats of the Royal Navy Lifeboat Institute are a great example of their reliability. The Fischer Panda AGT Generators installed on these boats have been in operation since 1997.
Longer lifespan for generator Reduced maintenance costs Reduced environmental pollution Reduced exhaust emissions Reduced fuel consumption Less noise onboard & outside Longer battery life Smaller battery bank possible Up to 30 % smaller and lighter Automatic start as standard (manual start as option)
Panda Advanced Generator Technology (AGT-DDC) DC Vehicle Generators
Panda Standard Asynchronous (PSA) AC Vehicle Generators
12 V / 24 V / 48 V DC (other voltages on request)
3000 rpm - 50 Hz - 230 V 3000 rpm - 50 Hz - 400 V AC 3600 rpm - 60 Hz - 120 / 240 V AC 3600 rpm - 60 Hz - 208 V AC
Panda Advanced Generator TechnologyHeavy Duty (AGT-HD) DC Vehicle Generators
Panda Standard Asynchron Heavy Duty (PSA-HD) AC Vehicle Generators
12 V / 24 V / 48 V DC (other voltages on request)
1500 rpm - 50 Hz - 230 V 1500 rpm - 50 Hz - 400 V AC 1800 rpm - 60 Hz - 120 / 240 V AC 1800 rpm - 60 Hz - 208 V AC
Battery (12/ 24/48V DC) DC Power Circuit 12V / 24V DC
Inverter
AC Power Circuit 230 V / (120/240V ) AC
Fridges / Freezers / Boiling
Domestic Electrical Appliances
Air Conditioning
9
Complete Program Fischer Panda generators are available in different versions to suit your needs Fischer Panda generators are compactly constructed and highly suited for applications which have limited space available for installation. Generators are available for internal installation within the vehicle and external mounting on the chassis. The modular versions PVMV-N, PVM-NE and PVK-U have been designed to be installed with an external radiator. The most effective cooling is usually achieved using a cooling system with a roof-mounted radiator.
Panda PVMV-N
Panda PVK-UK
Vehicle generator with sound insulation capsule, integrated water-cooled vertically mounted pre-silencer and main silencer
Panda Vehicle Generator "Compact Construction" with integrated cooling system for mounting externally on the vehicle chassis
Easy to install Requires external radiator Suitable for keel cooling on boats
Designed for external mounting Assembly bolts pre-fitted to housing Metal capsule with a heavy duty cover construction
Suitable for internal installation Best choice, when space and length are available Water-cooled silencer completely integrated within the capsule
Wide access hatch for easier access Sound insulation capsule Water-cooled exhaust silencer inside capsule
Reinforced glass fibre (GRP) capsule is standard for models up to 12 kW Stainless steel capsule (MPL) for models from 15 kW and above
No additional exhaust silencer required Integrated radiator and cooling system
Panda PVM-NE
Panda PSC (V)
The PVM-NE is similar to the PVMV-N version except that the silencer is externally mounted on the capsule which is not water-cooled. This is the standard version for generators over 30kW. No additional silencer is necessary. This version must be installed in a well-ventilated area due to the heat absorbed by the silencer. The generator is housed within a sound insulation capsule.
These fully self-contained generators are fitted with an integrated cooling system, fuel tank and electrical cabinet.
Suitable for internal installation Requires external radiator Easy to install
10
Integrated fuel tank Vertically mounted radiator Suitable for external mounting
Sound insulation capsule Water-cooled exhaust silencer inside capsule No additional exhaust silencer required Integrated radiator and cooling system
Panda PVK-U
Panda PSC (H)
Panda Vehicle Generator with internal water-cooled silencer for mounting externally on the vehicle chassis
These fully self-contained generators are fitted with an integrated cooling system, fuel tank and electrical cabinet.
Designed for external mounting Assembly bolts pre-fitted to housing Metal capsule with a heavy duty cover construction
Integrated fuel tank Horizontally mounted radiator Suitable for external mounting
Wide access hatch for easier access Water-cooled exhaust silencer mounted inside capsule No additional exhaust silencer required Requires external radiator
Sound insulation capsule Water-cooled exhaust silencer inside capsule No additional exhaust silencer required Integrated radiator and cooling system
11
Generator Nominal Performance
12
Capsule Dimensions L x W x H (mm)
Weight incl. Capsule (kg)
Standard Capsule Type
Standard Sound Insulation
Capsule Dimensions L x W x H (mm)
Weight incl. Capsule (kg)
Standard Capsule Type
Standard Sound Insulation
309
1
54/64/68
750x420x420
133
MPL
4DS
request
150
MPL
4DS
1270x439x440
176
MPL
4DS
-
±3V
Kubota
EA300
309
1
54/64/68
750x420x420
133
MPL
4DS
request
150
MPL
4DS
1270x439x440
176
MPL
4DS
150 GFK
4DS
request
request
MPL
4DS
request
request
MPL
4DS
Standard Sound Insulation
EA300
Standard Capsule Type
Kubota
Weight incl. Capsule (kg)
±3V
1-phase 3-phase
Capsule Dimensions L x W x H (mm)
(kVA)
Standard Sound Insulation
(kW)
Weight incl. Capsule (kg)
(kVA)
Capsule Dimensions L x W x H (mm)
(kW)
Standard Capsule Type
50 Hz
7m / 3m / 1m (dbA)
50 Hz
No. of Cylinders
230/400 V 1plus 3-phase 50 Hz
PVK-UK
Displacement cm3
400 V 3-phase
PVK-U
Engine Type
230 V 1-phase
PVM-NE
Engine Manufactuter
Model / Type
PVMV-N
DVS Voltage Tolerance
Panda Generator
HP3
Sound Level
HP1
Inverter Line - Panda Generators with fixed speed technology Panda 4000i
4.0
4.7
-
-
-
-
Inverter Line - Panda Generators with variable speed technology Panda 4000i
0-4.0
4.7
-
-
-
-
-
-
±3V
Kubota
Z482
479
2
52/62/67
760x515x609
-
-
-
±3V
Kubota
D 902
898
3
request
request
request
GFK
4DS
request
request
MPL
4DS
request
request
MPL
4DS
Panda 6000i
0-6.0
7.0
Panda 12000i
0-12.0
14.1
-
-
Basic Line - Panda ND Generators - 3000 rpm - 50 Hz Panda Vehicle Generators without electronic regulation Panda 4,5 ND
3.8
4.5
-
-
-
-
±8%
Farymann
18W430
298
1
54/64/68
765x445x570
161
GFK
4DS
800x440x570
195
MPL
4DS
1245x440x570
240
MPL
4DS
Panda 6000 ND
5.1
6.0
5.1
6.0
-
-
±8%
Kubota
Z 482
479
2
52/62/67
865x515x635
241
GFK
4DS
870x520x620
284
MPL
4DS
1260x520x590
352
MPL
4DS
Premium Line Panda NE Generators - 3000 rpm - 50 Hz Panda Vehicle Generators with VCS Voltage Control System Panda 5000 LPE 1)
4.0
4.8
4.0
4.8
3.5
3.5
±3V
Kubota
EA 300
309
1
54/64/68
730x580x430
221
MPL
4DS
730x580x430
226
MPL
4DS
1070x580x480
266
MPL
4DS
Panda 8.000 NE
6.8
8.0
6.8
8.0
6.0
6.0
±3V
Kubota
Z 482
479
2
52/62/67
865x515x635
230
GFK
4DS
870x523x580
279
MPL
4DS
1330x522x620
352
MPL
4DS
Panda 10.000 NE
8.0
9.0
8.0
9.0
7.0
7.0
±3V
Kubota
Z 602
599
2
52/62/67
GFK
4DS
request
request
MPL
4DS
request
request
MPL
4DS
Panda 12.000 NE
10.2
12.0
10.2
12.0
9.0
9.0
±3V
Kubota
D 722
719
3
53/63/67
950x515x625
253
GFK
4DS
960x530x625
317
MPL
4DS
1566x530x625
411
MPL
4DS
Panda 15.000 NE
12.7
15.0
12.7
15.0
11.1
11.1
±3V
Kubota
D 902
898
3
54/64/68
950x515x625
298
GFK
4DS
1000x530x630
377
MPL
4DS
1606x522x630
436
MPL
4DS
Panda 18 NE
15.3
18.0
15.3
18.0
13.5
13.5
±3V
Kubota
D 1105
1123
3
55/65/69
1100x540x680
415
MPL
4DS
1100x560x680
440
MPL
4DS
1737x560x680
544
MPL
4DS
request
Panda 24 NE
20.4
24.0
20.4
24.0
18.0
18.0
±3V
Kubota
V 1505
1498
4
55/65/69
1220x540x680
465
MPL
4DS
1225x542x684
492
MPL
4DS
1854x542x684
492
MPL
4DS
Panda 30 NE
25.5
30.0
25.5
30.0
22.4
22.4
±3V
Kubota
V 1505T
1498
4
55/65/69
1270x570x700
512
MPL
4DS
1270x570x690
530
MPL
4DS
1970x564x640
687
MPL
4DS
Panda 35 YA
-
-
28.0
35.0
-
-
±3V
Yanmar
4TNV88
2190
4
57/67/71
1398x640x780
650
MPL
4DS
1420x640x730
644
MPL
4DS
request
request
MPL
4DS
Panda 47 YA
-
-
40.0
47.0
-
-
±3V
Yanmar
4TNV84T
1995
4
57/67/71
1415x650x780
760
MPL
4DS
request
request
MPL
4DS
request
request
MPL
4DS
Panda 60 MB
-
-
51.0
60.0
-
-
±3V
Merc.Benz
OM 605A
2497
5
58/68/72
1665x730x810
933
MPL
4DS
request
request
MPL
6DS
request
request
MPL
6DS
Panda 75 MB
-
-
63.7
75.0
-
-
±3V
Merc.Benz OM603A 3.5
3500
6
58/68/72
1845x730x830
1100
MPL
4DS
request
request
MPL
6DS
request
request
MPL
6DS
Panda 100 MB
-
-
85.0
100.0
-
-
±3V
Merc.Benz OM603A 3.5
3500
6
58/68/72
1720x780x860
1150
MPL
4DS
request
request
MPL
6DS
request
request
MPL
6DS
3
52/62/66
MPL
4DS
request
request
MPL
4DS
Panda HD - 1500 rpm - 50 Hz Panda Vehicle Heavy Duty Generators with VCS Voltage Control System Panda 7,5-4 HD
6.5
7.6
6.5
7.6
-
-
±3V
Kubota
D1005
1001
1055x515x665
338
GFK
4DS
request
Panda 9-4 HD
8.0
9.4
8.0
9.4
-
-
±3V
Kubota
D 1105
1123
3
52/62/66
1055x515x670
389
MPL
4DS
1100x560x680
Panda 12-4 HD
10.5
12.3
10.5
12.3
-
-
±3V
Kubota
V 1505
1498
4
52/62/66
1170x540x680
488
MPL
4DS
request
544
MPL
4DS
request
request
MPL
4DS
MPL
4DS
request
request
MPL
4DS
Panda 17-4 HD
14.7
17.5
14.7
17.5
-
-
±3V
Kubota
V 2203
2197
4
53/63/67
1300x620x800
581
MPL
4DS
request
MPL
4DS
request
request
MPL
4DS
Panda 22-4 HD
18.6
21.9
18.6
21.9
-
-
±3V
Kubota
V2403M
2434
4
53/63/67
1390x610x770
643
MPL
4DS
1390x600x760
643
MPL
4DS
request
request
MPL
4DS
Panda 30-4 HD
25.0
29.4
25.0
29.4
-
-
±3V
Kubota
V3300
3318
4
request
1473x690x890
400
MPL
4DS
request
request
MPL
4DS
request
request
MPL
4DS
Panda 40-4 HD
-
-
35.0
41.1
-
-
±3V
Kubota
V3300T
3318
4
request
1560x710x950
867
MPL
4DS
request
request
MPL
4DS
request
request
MPL
4DS
40.0
47.0
±3V
Kubota
V3800T
3769
4
request
1760x800x900
891
MPL
4DS
request
request
MPL
4DS
request
request
MPL
4DS
Panda 60-4 DZ
-
-
50.4
59.3
-
-
±3V
Deutz
BF4M2012C
4040
4
request
1500x790x1000
1298
MPL
6DS
request
request
MPL
6DS
request
request
MPL
6DS
Panda 70-4 DZ
-
-
61.6
72.5
-
-
±3V
Deutz
BF4M1013E
4764
4
request
request
request
MPL
6DS
request
request
MPL
6DS
request
request
MPL
6DS
Panda 85-4 DZ
-
-
73.6
86.6
-
-
±3V
Deutz
BF4M1013EC 4764
4
request
1650x830x1100
1589
MPL
6DS
request
request
MPL
6DS
request
request
MPL
6DS
Panda 110-4 DZ
-
-
92.8
109.2
-
-
±3V
Deutz
7146
6
request
request
request
MPL
6DS
request
request
MPL
6DS
request
request
MPL
6DS
Panda 130-4 DZ
-
-
111.2
130.8
-
-
±3V
Deutz
BF6M1013EC 7146
6
request
request
request
MPL
6DS
request
request
MPL
6DS
request
request
MPL
6DS
Capsule Dimensions L x W x H (mm)
Weight incl. Capsule (kg)
Standard Capsule Type
Standard Sound Insulation
Capsule Dimensions L x W x H (mm)
Weight incl. Capsule (kg)
Standard Capsule Type
Standard Sound Insulation
Capsule Dimensions L x W x H (mm)
Standard Sound Insulation
Panda 50-4 HD
BF6M1013E
Standard Capsule
Standard Sound Insulation
Standard Capsule Type
Weight incl. Capsule (kg)
Capsule Dimensions L x W x H (mm)
Sound Level
N0. of Cylinders
Displacement cm3
Engine Type
Engine Manufactuter
Voltage Tolerance
Engine Revolutions
Constant current rate (A)
Weight incl. Capsule (kg)
AGT 4000-24
Nominal voltage (DC)
AGT Standard Generator with sound insulation capsule AGT 4000-12
Continuous Performance (kW)
Panda AGT-DDC Battery Charging Generators with VCS Voltage Control System Nominal Performance (kW)
Technical Data for Vehicle Generators ND Versions The ND versions of the Fischer Panda generators are an ideal for the priceconscious customer. The generators are identical to the NE models in respect of all main components, such as engine, generator, sound insulation casing, water-cooling etc. ND generators are not fitted with an electronic speed control. The voltage tolerance lies therefore within an acceptable range of ±8 %. This is similar to a land power connection. NE (and HD) Versions The Panda generator NE version has been fitted for many years with the tried and tested Voltage Control System (VCS) whereby the motor speed is progressively controlled. This has an enormously positive effect on the exhaust emission and ensures that the generator achieves up to 15 % more effective performance than other noncontrolled generators. The VCS adjusts the voltage with a tolerance of ±3 volts in the range up to 80% of the nominal performance. An external AC control box contains the VCS and the capacitors which are used for boosting the starting current (standard for Panda 5000 LPE up to Panda18 NE). 1) LP = Low Profile (especially low construction) Fischer Panda GmbH reserves the right to change technical information without prior notice. All performance data relates to air and water temperatures of 20°. Performance reduction (approx 1% per 100 m height and approx 2% per 5°C air temperature and approx. 1% per 1°C water temperature above 20°C). The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets.
MPL
4DS
114
MPL
4DS
4
3.2
12
220
2400-3000
±3V
Kubota
EA 300
309
1
55/65/69
750x420x420
119
MPL
3D
request
request
MPL
4DS
request
4
3.2
24
110
2400-3000
±3V
Kubota
EA 300
309
1
52/62/67
750x420x420
119
MPL
3D
request
request
MPL
4DS
1115x420x420
3.6
12
250
1800-2200
±3V
Kubota
Z 482
479
2
52/62/67
750x505x615
189
GFK
4DS
request
request
MPL
4DS
request
MPL
4DS
4DS
4DS 4DS
AGT 5000-12
4.5
AGT 6000-24
5.5
4.8
24
170
2400-3200
±3V
Kubota
Z 482
479
2
52/62/67
760x515x609
189
GFK
4DS
request
request
MPL
request
MPL
AGT 8000-24
8
6.4
24
220
2200-2600
±3V
Kubota
D 722
719
3
53/63/67
860x505x635
216
GFK
4DS
request
request
MPL
4DS
request
MPL
AGT 12000
12
request
request
±3V
Kubota
D 902
898
3
54/64/68
request
GFK
4DS
request
request
MPL
4DS
request
MPL
4DS
AGT 14000
14
request
request
±3V
Kubota
D 1105
1123
3
55/65/69
request
GFK
4DS
request
request
MPL
4DS
request
MPL
4DS
request
request
±3V
Kubota
V1505
1498
4
55/65/69
1100x550x690
MPL
4DS
request
request
MPL
4DS
request
MPL
4DS
4DS
request
MPL
4DS
4DS
request
MPL
4DS
AGT 16000
16
AGT 25000
25
request
request
±3V
Kubota
V1505 T
1498
4
55/65/69
AGT 28000
28
request
request
±3V
Yanmar
4TNV88
2190
4
57/67/71
366
request
MPL
4DS
request
request
MPL
request
MPL
4DS
request
request
MPL
13
Complete Program - Radiator Options
AGT 28.000-96
AGT 25.000-72
AGT 16.000-48
AGT 14.000-48
AGT 12.000-48
AGT 8.000-24
AGT 6.000-24
AGT 5.000-12
AGT 4.000-24
AGT 4.000-12
Panda 130-4 DZ
Panda 110-4 DZ
Panda 85-4 DZ
Panda 70-4 DZ
Panda 60-4 DZ
Panda 50-4 HD
Panda 40-4 HD
Panda 30-4 HD
Panda 22-4 HD
Panda 17-4 HD
Panda 12-4 HD
Panda 09-4 HD
Panda 7,5-4 HD
Panda 100 MB
Panda 75 MB
Panda 60 MB
Panda 47 YA
Panda 35 YA
Panda 30 NE
Panda 24 NE
Panda 18 NE
Panda 15.000 NE
Panda 12.000 NE
Panda 10.000 NE
Panda 8.000 NE
Panda 5000 LPE
Panda 6000 ND
Panda 4,5 ND
Panda 12000i
Panda 6000i
Approx. Dimensions (L x B x H) mm
Panda 4000i
1)
Radiator Weight (dry) kg
Roof mounted Radiators
RD 1.2
RD-D: DC Roof mounted radiators RD 1.2
705 x 390 x 308
18
RD 2.2
930 x 515 x 317
28
RD 3.2
1055 x 515 x 312
32
RD 3.2 Trop
1055 x 515 x 352
x
x
x
x
x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
RD-A: AC Roof mounted radiators
RD6 / 2.2
RD3.3 - S350
1055 x 515 x 349
x
x
x
x
x
x
x
x
x
x
RD3.3 Trop - S350
1055 x 515 x 393
x
x
x
x
x
x
x
x
x
x
RD4.2 - FE040
659 x 610 x 370
32
x
x
x
x
x
x
x
x
x
x
RD16.2 - 2xFE040
1000 x 600 x 335
56
RD6/2.2 - 2xFE040
1350 x 550 x 360
57
RD6/2.2 - 2xFE045
1500 x 600 x 380
67
RD7.2 - FE071
1000 x 880 x 517
RD8.2 - FE063
1100 x 1080 x 537
RD P75 MB - 2xFE056
1900 x 990 x 531
x
request
RD P75 MB - FE080
on request
x
request
RD P100 MB - 2xFE056
on request
Side mounted Radiators
x
x x
x x
x
x
x
x
x x
x x
x
x x
x
x
x
x
RD2.2
x
x
x
x
request
1)
Expansion Tank
RV-D: Side-/underneath (chassis mounted) radiators DC x
x
x
x
RV1.2
615 x 330 x 214
13
RV2.2
760 x 450 x 224
21
RV3.2
900 x 450 x 224
24
x
x
x
RV3.2 Trop
900 x 450 x 254
30
x
x
x
x
x
x
x
x
x
x
x
x x
x
x
x
x
x
x
RV-A: Side mounted Radiators AC RV 3.3 -S350 RV 3.3 Trop - S350
900 x 450 x 294
RV 5.2 - FE040
610 x 580 x 358
32
RV 13.160 - FE050
600 x 719 x 436
52
RV 6/2.2 - 2xFE040
1200 x 550 x 270
RV 6/2.2 - 2xFE045
1200 x 550 x 285
RV 14.120 - FE056
780 x 690 x 420
48
RV 14.160 - FE056
780 x 690 x 460
55
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x
RV13.160
x
x
x x
x
x x x
x
x
x
x
x
x x
x
x
x
x
x x
x
x
RV3.2
x x
1000 x 800 x 420
63
1100 x 1000 x 420
78
RV P75 MB - 2xFE056
1900 x 1070 x 421
x
RV P75 MB - FE080
1270 x 1100 x 455
x
on request
x
x
x
RV 7.2 - FE071
1)
x
x
RV 8.2 - FE063
RV P100 MB - 2xFE056
14
x
900 x 450 x 254
x
x request request
x
request
No value = on request. Fischer Panda GmbH reserves the right to change technical information without prior notice.
15
- Power - wherever you are
Vehicle Generators - PVMV-N With integrated water-cooled primaryand secondary silencer. Suitable for stationary operation. The PVMV-N generator is a compact, standard solution for use in vehicle applications. Vehicle Generators PVK-U Generators housed in sound-insulated stainless steel capsules which are suitable for mounting externally beneath vehicles. Vehicle Generators PVK-UK Extremely compact and quiet generating set for vehicles featuring an integrated radiator. Suitable for mounting externally beneath vehicle. AGT DC Battery Charging Generators Diesel battery-charging generators with 12, 24 or 48 V. The “AGT” technology is available from 2.5 to approx. 50 kW. Very efficient, compact with hidden cooling system and only available from Fischer Panda. AGT-DE Drive Generators Specially designed generators for dieselelectric drive systems. Highly efficiency and economical operation are particular characteristics of this generator. High-Performance Alternators Compact “High Output” alternators up to 3.2 kW, charging rate up to 260 A at 12 V DC. Available in 12 or 24 volt DC. Radiators and Installation Parts All vehicle and stationary generators are cooled either via an integrated or external DC/AC radiator. Solutions for specific customer requirements are possible. Installation parts for vehicle and marine generators are part of the standard product range.
Whisperprop-System with DieselElectric Drive Complete drive system comprising generator and electric motor with control. The AGT-DE Generator and permanent magnet motor are extremely efficient and compact. Can completely replace existing on-board power systems when combined with a Victron Power System.
Aziprop
Shaft
Saildrive
AC Distribution Boxes A reliable and safe electrical supply is an absolute “must”. For a safe supply from multiple sources such as shore power, generator and inverter to each of the electrical consumers and serves as a central location for the AC system’s circuit breakers. Parallel Transfer Units These units are designed for synchronizing two Fischer Panda AC Generators in parallel so the load can be switched or combined to double the total power available. VICTRON Battery Chargers, Inverters and Combi-units up to 12,5 kW Fischer Panda in cooperation with Victron Energy. Victron inverters are available for 12, 24 and 48 V DC which can supply up to 12.5 kW parallel or be switched to a 3phase system. Professional charging units in 12, 24 and 48 V DC with up to 600A. Combi-units including high performance battery chargers are also available. Battery Monitors Easy to use and convenient battery monitoring. The charge level is displayed and prevents batteries from being unexpectedly discharged. This device can automatically start and stop the generator. System Control Board Features a touch screen and gives you full control of your on board devices and displays status including level indicators for batteries, supply, fuel and water levels of devices on board. Devices, including generator, can be switched “on” and “off” via the panel. vehicle_combined.indd stand:20100226
Marine Generators - PMS The world famous Panda Generators with sea-water cooled heat exchanger, dual-circuit cooling and wet exhaust.