Preview only show first 10 pages with watermark. For full document please download

Vehicle Generators

   EMBED


Share

Transcript

Vehicle Generators High Performance Emergency Services Extremely Quiet Water-Cooled Compact Broadcasting Light Events & Tradeshows Mobile Homes Railways Commercial Marine Power Systems for Mobile and Stationary Applications Panda Vehicle Generators Mobile and Stationary Applications Fischer Panda GmbH manufactures compact and quiet diesel generators for marine and vehicle applications. These are sold in over sixty countries worldwide under the trade name “Fischer Panda.” Developed for use in special and diverse areas of the vehicle industry, Fischer Panda generators can be found supplying power to a vast range of applications worldwide. Recreational & Touring The company, based in Paderborn-Germany, was originally founded in 1977 under the name Icemaster GmbH and renamed to Fischer Panda GmbH in 2007. Motorized RVs Expedition Vehicles Mobile Homes The water-cooled diesel generators from Fischer Panda are renowned worldwide for being innovative, reliable and extremely quiet. The product range includes over two hundred different generators and covers a performance range from 2.5 kW to 200 kW. Luxury Motor Coaches Limousine Coaches Holiday Homes Fischer Panda generators feature an effective water-cooling system and a lightweight compact construction. This ensures Fischer Panda generators are the No. 1 in Europe for mobile super-silent diesel generators. These highly-proven marine and vehicle generators supply power to on-board electrical systems, electric drives and complete mobile energy systems. Mobile Broadcasting & Communications Mobile Stages Trade Show Vehicles Communications & Promotion Formula 1 Team Vehicles Border Control & Customs Commercial Vehicles Emergency & Specialist Services Emergency Command Centres Police / Ambulance / Fire -Fighting Mobile Blood Donor Units Easy to operate Compact Construction 100% Water-cooling Sound Insulation Environmental Monitoring Railway & Track Maintenance Tactical Shelters Efficient Diesel Engines Fischer Panda generators can be found installed in the smallest and tightest places onboard. Simple to maintain 2 Preinstalled connections Power - just like at home 3 Compact, Quiet Vehicle Generators The most significant advantage of the Fischer Panda generator is the very low sound level. There are many components required to work together to achieve this result. As no cooling air flow inside of the capsule is required, this also ensures that ambient temperatures remain constant. An efficient watercooling system requires that the radiator be installed separately from the generator. Vehicle Installation - roof-mounted radiator The radiator must be installed where good access for fresh air circulation is guaranteed. The best location is horizontally on the roof of the vehicle. The radiator has an integrated expansion tank. Roof-mounted radiator with integrated expansion tank Panda Generator Vehicle Installation - side-mounted radiator A radiator can be fitted to the vehicle‘s side if there is no room on the roof. Less space required for installation Water-cooled winding Can be installed anywhere onboard Hermetically sealed capsule All connections prefitted on capsule Modular design ensures installation flexibility No appreciable warming of the installation area Super-silent sound insulation system Water-cooled silencer (up to 25 kW) No cooling air circulating within capsule Expansion tank (optional) Side-mounted radiator Super-Silent Sound Insulation System Fischer Panda generators up to 25 kW are delivered with a GFK sound insulation capsule with “3D” sound insulation material as standard (optional: sound insulation material “4DS”). From 30 kW, the capsule is delivered as a stainless steel-version MPL. The MPL sound insulation casing can be split up and consists of 6 - 11 parts, depending on the size of the generator. The MPL capsules are also available at an extra cost for generators from 6 kW to 25 kW. Different versions of sound insulation material are available: 3D 3 layers, up to 25 mm thick 4DS up to 5 layers, up to 40 mm thick 6DS up to 6 layers, up to 60 mm thick Water-cooled Exhaust Silencer PVMV-N, PVK-U and PVK-UK generators (up to 25 kW) are fitted with a water-cooled exhaust silencer. Panda Generator Vehicle Installation - underneath chassis It may be possible to mount a radiator under the chassis if it is not possible to mount the radiator on the roof or the vehicle‘s side. Note: Sufficient clearance must be available to allow the air to circulate correctly so that warm air does flow back over the radiator. Expansion tank Radiator mounted underneath vehicle Panda Generator water-cooled pre-silencer hot exhaust gases main silencer cooled exhaust gases 4 Marine Installation - keel cooling An interesting alternative to seawater cooling for marine vessels is using a Fischer Panda vehicle generator in conjuction with a keel cooler. This eliminates the need for raw water pumps, strainers and an inboard heat exchanger. Expansion tank Panda Generator 5 Reliable High Performance Windings All the benefits of the Asynchronous Generator and more.... Available in three different versions: 230 V - 50 Hz AC or 120 V / 240 V - 60 Hz The HP1 is the standard version for 230 Volt 50 Hz ( 120 / 240 V - 60 Hz) AC. This is available up to 25 kW. From 12 kW, a three phase version should be considered, as the Panda generator permits dissymmetrical loads up to 50% per phase. A check should always be made as to whether a DC-AC Power System would be the better solution for small to middle ranged power systems. (See DC-AC Power System) High protection rating High control precision No rotating coils No diodes No signal noise Highly efficient lighting satellite receivers boilers ventilators air conditioners ovens compressors electric motors lighting satellite receivers Single Phase Single Phase - HP1 Water-cooled Overload protection Short-circuit stability The Panda offers all the advantages of the classic asynchronous generator and with the patented Voltage Control System (VCS), produces control precision that cannot be beaten by a conventional synchronous generator. The excellent qualities of the conOverload trolled Panda asynchronous generator have been impressively proven in many tests over the past years. Water-cooled Protection The asynchronous generator has always set high standards with regard to operational security and its lifespan. Therefore, the asynchronous generator is often the compulsory choice where a high degree of safety and reliability is demanded. This is of particular importance for professional applications, emergency services and technical response units. Fischer Panda even warrants the rotor with a lifetime guarantee - the rotor is often the most sensitive part of other generator systems. As the components which produce the most heat are located on the stator, the asynchronous generator continues to be the best suited for water-cooling. The electrical generator is warranted with a 5 year guarantee against corrosion. Monitoring and Operation The generator switches itself off when any of these functions are not in the normal state. The standard remote control panel can be upgraded with a additional automatic module to enable the generator to be started (and stopped) by external devices such as timers etc. The 400 Volt three phase winding has the highest level of efficiency and the best qualities. Also, this winding can supply single phase AC with the appropriate phase distribution. This enables each phase to be overloaded by up to 50 %. A three-phase generator should always be chosen above 25 kW (from Panda 30 NE). Dual Voltage System (DVS) Combined unit with single and three phase windings The “DVS” Combi-Winding is a special version for 50 Hz generators consisting of two separate coils without additional costs. A 400 Volt three-phase winding is combined with a one phase winding. This permits the use of three phase motors (i.e. compressors for air conditioners and power tools etc). The separate one phase winding can supply the full nominal performance of the generator without “dissymmetrical load problems” to a phase, which simplifies the electrical installation. air conditioners ovens Note: Generators with a DVS winding supply approximately 85% of the nominal performance compared with the HP1 or HP3 windings. Single Phase + Three Phase 400 V - 50 Hz AC or 208 V - 60 Hz AC Three Phase Three Phase - HP3 Brushless Perfect sine wave Highest operating protection Patented VCS Voltage Control System Dual Volta Syste ge (DVS) m - only from Fische r Pand a Extremely Clean Sine Wave Remote Control Panel P4 Plus The standard version remote control panel (from Panda 6000 ND upwards) monitors the following 6 functions: Engine coolant temperature Engine exhaust temperature Engine oil pressure Generator Control Panel Battery charging 230 Volt AC Cooling water leak (optional) The Panda asynchronous generator supplies a particularly clean sine wave and achieves the best result from numerous tests in this category. This guarantees the smooth running of electronic devices such as air conditioners, charging devices, etc. The outstanding sine wave of the Fischer Panda generator Tolerance of ±3V with patented Voltage Control System The Fischer Panda Voltage Control System (VCS) has been used for more than ten years to regulate the generator and engine. The engine speed is progressively adjusted which ensuring that the voltage of the asynchronous generator has a tolerance of ± 3 volts. The Fischer Panda generator combines all the advantages of the asynchronous generator with the voltage control of a synchronous generator. (for Panda Generator 6000ND and above) 6 7 Complete Program - AC and DC Generators Professional solutions for all recreational and commercial power applications DC Generators for battery charging and power circuits onboard AC Generators for supplying standard power circuits onboard AC direct Fischer Panda has a wide range of generator types for use in mobile power applications: 1. Panda Asynchronous Generators (PSA and PSA-HD), which directly produce alternating current (AC) whilst running. These generators are ideal if your power is required in continuous operation. 2. Permanent Magnet Generators (AGT-DDC) produce direct current (DC) and function as part of a DC Hybrid Power System. A battery bank is used with an inverter within this system to supply the power circuit onboard. The level of the batteries can be monitored and the batteries can be automatically charged by an AGT Generator. This system is optimal if your power is required in interval operation throughout the day. AC indirect 3000 rpm - The ideal speed for powering up to 30 kW Low frequencies contain more energy and their energy-rich vibrations are transmitted to all components within the surrounding area. You will “notice” the generator throughout the whole vehicle. A correctly installed 3000 rpm generator that is housed within an insulation capsule is quieter than a slow-runner (often the opposite is presumed). Less: Weight Fuel Consumption Reduced: Dimensions Purchase Price Generators running at 1500 rpm are heavier and larger than their counterparts operating at 3000 rpm. As weight and space play such an important role in modern vehicle constructions, the smaller generator with 3000 rpm has considerable advantages. The high reliability and longer lifespan of a slow-runner is not always an important aspect, because the modern diesel engine operates within its ideal speed range. This is closer to 3000 / 3600 revolutions per minute than 1500 / 1800. As a result of their effective water-cooling, even at higher surrounding temperatures, Panda generators can be up to 20% more efficient than other units of a comparable size. Your individual application and installation requirements should be considered in each case. 3000 / 3600 rpm = Panda PSA 1500 / 1800 rpm = Panda PSA-HD Hybrid Power Systems The Fischer Panda innovative and integrated energy systems provide on-board power for vehicles and marine vessels without the requirement to have a permanently running generator. d ance r v d A o erat T) Gen (AG y g nolo Tech from a only and P r e Fisch 8 The extremely robust AGT generators have proven their reliability under extremely adverse conditions. Problems concerning empty batteries and independent power supplies are impressively solved using this Fischer Panda technology. The 75 lifeboats of the Royal Navy Lifeboat Institute are a great example of their reliability. The Fischer Panda AGT Generators installed on these boats have been in operation since 1997. Longer lifespan for generator Reduced maintenance costs Reduced environmental pollution Reduced exhaust emissions Reduced fuel consumption Less noise onboard & outside Longer battery life Smaller battery bank possible Up to 30 % smaller and lighter Automatic start as standard (manual start as option) Panda Advanced Generator Technology (AGT-DDC) DC Vehicle Generators Panda Standard Asynchronous (PSA) AC Vehicle Generators 12 V / 24 V / 48 V DC (other voltages on request) 3000 rpm - 50 Hz - 230 V 3000 rpm - 50 Hz - 400 V AC 3600 rpm - 60 Hz - 120 / 240 V AC 3600 rpm - 60 Hz - 208 V AC Panda Advanced Generator TechnologyHeavy Duty (AGT-HD) DC Vehicle Generators Panda Standard Asynchron Heavy Duty (PSA-HD) AC Vehicle Generators 12 V / 24 V / 48 V DC (other voltages on request) 1500 rpm - 50 Hz - 230 V 1500 rpm - 50 Hz - 400 V AC 1800 rpm - 60 Hz - 120 / 240 V AC 1800 rpm - 60 Hz - 208 V AC Battery (12/ 24/48V DC) DC Power Circuit 12V / 24V DC Inverter AC Power Circuit 230 V / (120/240V ) AC Fridges / Freezers / Boiling Domestic Electrical Appliances Air Conditioning 9 Complete Program Fischer Panda generators are available in different versions to suit your needs Fischer Panda generators are compactly constructed and highly suited for applications which have limited space available for installation. Generators are available for internal installation within the vehicle and external mounting on the chassis. The modular versions PVMV-N, PVM-NE and PVK-U have been designed to be installed with an external radiator. The most effective cooling is usually achieved using a cooling system with a roof-mounted radiator. Panda PVMV-N Panda PVK-UK Vehicle generator with sound insulation capsule, integrated water-cooled vertically mounted pre-silencer and main silencer Panda Vehicle Generator "Compact Construction" with integrated cooling system for mounting externally on the vehicle chassis Easy to install Requires external radiator Suitable for keel cooling on boats Designed for external mounting Assembly bolts pre-fitted to housing Metal capsule with a heavy duty cover construction Suitable for internal installation Best choice, when space and length are available Water-cooled silencer completely integrated within the capsule Wide access hatch for easier access Sound insulation capsule Water-cooled exhaust silencer inside capsule Reinforced glass fibre (GRP) capsule is standard for models up to 12 kW Stainless steel capsule (MPL) for models from 15 kW and above No additional exhaust silencer required Integrated radiator and cooling system Panda PVM-NE Panda PSC (V) The PVM-NE is similar to the PVMV-N version except that the silencer is externally mounted on the capsule which is not water-cooled. This is the standard version for generators over 30kW. No additional silencer is necessary. This version must be installed in a well-ventilated area due to the heat absorbed by the silencer. The generator is housed within a sound insulation capsule. These fully self-contained generators are fitted with an integrated cooling system, fuel tank and electrical cabinet. Suitable for internal installation Requires external radiator Easy to install 10 Integrated fuel tank Vertically mounted radiator Suitable for external mounting Sound insulation capsule Water-cooled exhaust silencer inside capsule No additional exhaust silencer required Integrated radiator and cooling system Panda PVK-U Panda PSC (H) Panda Vehicle Generator with internal water-cooled silencer for mounting externally on the vehicle chassis These fully self-contained generators are fitted with an integrated cooling system, fuel tank and electrical cabinet. Designed for external mounting Assembly bolts pre-fitted to housing Metal capsule with a heavy duty cover construction Integrated fuel tank Horizontally mounted radiator Suitable for external mounting Wide access hatch for easier access Water-cooled exhaust silencer mounted inside capsule No additional exhaust silencer required Requires external radiator Sound insulation capsule Water-cooled exhaust silencer inside capsule No additional exhaust silencer required Integrated radiator and cooling system 11 Generator Nominal Performance 12 Capsule Dimensions L x W x H (mm) Weight incl. Capsule (kg) Standard Capsule Type Standard Sound Insulation Capsule Dimensions L x W x H (mm) Weight incl. Capsule (kg) Standard Capsule Type Standard Sound Insulation 309 1 54/64/68 750x420x420 133 MPL 4DS request 150 MPL 4DS 1270x439x440 176 MPL 4DS - ±3V Kubota EA300 309 1 54/64/68 750x420x420 133 MPL 4DS request 150 MPL 4DS 1270x439x440 176 MPL 4DS 150 GFK 4DS request request MPL 4DS request request MPL 4DS Standard Sound Insulation EA300 Standard Capsule Type Kubota Weight incl. Capsule (kg) ±3V 1-phase 3-phase Capsule Dimensions L x W x H (mm) (kVA) Standard Sound Insulation (kW) Weight incl. Capsule (kg) (kVA) Capsule Dimensions L x W x H (mm) (kW) Standard Capsule Type 50 Hz 7m / 3m / 1m (dbA) 50 Hz No. of Cylinders 230/400 V 1plus 3-phase 50 Hz PVK-UK Displacement cm3 400 V 3-phase PVK-U Engine Type 230 V 1-phase PVM-NE Engine Manufactuter Model / Type PVMV-N DVS Voltage Tolerance Panda Generator HP3 Sound Level HP1 Inverter Line - Panda Generators with fixed speed technology Panda 4000i 4.0 4.7 - - - - Inverter Line - Panda Generators with variable speed technology Panda 4000i 0-4.0 4.7 - - - - - - ±3V Kubota Z482 479 2 52/62/67 760x515x609 - - - ±3V Kubota D 902 898 3 request request request GFK 4DS request request MPL 4DS request request MPL 4DS Panda 6000i 0-6.0 7.0 Panda 12000i 0-12.0 14.1 - - Basic Line - Panda ND Generators - 3000 rpm - 50 Hz Panda Vehicle Generators without electronic regulation Panda 4,5 ND 3.8 4.5 - - - - ±8% Farymann 18W430 298 1 54/64/68 765x445x570 161 GFK 4DS 800x440x570 195 MPL 4DS 1245x440x570 240 MPL 4DS Panda 6000 ND 5.1 6.0 5.1 6.0 - - ±8% Kubota Z 482 479 2 52/62/67 865x515x635 241 GFK 4DS 870x520x620 284 MPL 4DS 1260x520x590 352 MPL 4DS Premium Line Panda NE Generators - 3000 rpm - 50 Hz Panda Vehicle Generators with VCS Voltage Control System Panda 5000 LPE 1) 4.0 4.8 4.0 4.8 3.5 3.5 ±3V Kubota EA 300 309 1 54/64/68 730x580x430 221 MPL 4DS 730x580x430 226 MPL 4DS 1070x580x480 266 MPL 4DS Panda 8.000 NE 6.8 8.0 6.8 8.0 6.0 6.0 ±3V Kubota Z 482 479 2 52/62/67 865x515x635 230 GFK 4DS 870x523x580 279 MPL 4DS 1330x522x620 352 MPL 4DS Panda 10.000 NE 8.0 9.0 8.0 9.0 7.0 7.0 ±3V Kubota Z 602 599 2 52/62/67 GFK 4DS request request MPL 4DS request request MPL 4DS Panda 12.000 NE 10.2 12.0 10.2 12.0 9.0 9.0 ±3V Kubota D 722 719 3 53/63/67 950x515x625 253 GFK 4DS 960x530x625 317 MPL 4DS 1566x530x625 411 MPL 4DS Panda 15.000 NE 12.7 15.0 12.7 15.0 11.1 11.1 ±3V Kubota D 902 898 3 54/64/68 950x515x625 298 GFK 4DS 1000x530x630 377 MPL 4DS 1606x522x630 436 MPL 4DS Panda 18 NE 15.3 18.0 15.3 18.0 13.5 13.5 ±3V Kubota D 1105 1123 3 55/65/69 1100x540x680 415 MPL 4DS 1100x560x680 440 MPL 4DS 1737x560x680 544 MPL 4DS request Panda 24 NE 20.4 24.0 20.4 24.0 18.0 18.0 ±3V Kubota V 1505 1498 4 55/65/69 1220x540x680 465 MPL 4DS 1225x542x684 492 MPL 4DS 1854x542x684 492 MPL 4DS Panda 30 NE 25.5 30.0 25.5 30.0 22.4 22.4 ±3V Kubota V 1505T 1498 4 55/65/69 1270x570x700 512 MPL 4DS 1270x570x690 530 MPL 4DS 1970x564x640 687 MPL 4DS Panda 35 YA - - 28.0 35.0 - - ±3V Yanmar 4TNV88 2190 4 57/67/71 1398x640x780 650 MPL 4DS 1420x640x730 644 MPL 4DS request request MPL 4DS Panda 47 YA - - 40.0 47.0 - - ±3V Yanmar 4TNV84T 1995 4 57/67/71 1415x650x780 760 MPL 4DS request request MPL 4DS request request MPL 4DS Panda 60 MB - - 51.0 60.0 - - ±3V Merc.Benz OM 605A 2497 5 58/68/72 1665x730x810 933 MPL 4DS request request MPL 6DS request request MPL 6DS Panda 75 MB - - 63.7 75.0 - - ±3V Merc.Benz OM603A 3.5 3500 6 58/68/72 1845x730x830 1100 MPL 4DS request request MPL 6DS request request MPL 6DS Panda 100 MB - - 85.0 100.0 - - ±3V Merc.Benz OM603A 3.5 3500 6 58/68/72 1720x780x860 1150 MPL 4DS request request MPL 6DS request request MPL 6DS 3 52/62/66 MPL 4DS request request MPL 4DS Panda HD - 1500 rpm - 50 Hz Panda Vehicle Heavy Duty Generators with VCS Voltage Control System Panda 7,5-4 HD 6.5 7.6 6.5 7.6 - - ±3V Kubota D1005 1001 1055x515x665 338 GFK 4DS request Panda 9-4 HD 8.0 9.4 8.0 9.4 - - ±3V Kubota D 1105 1123 3 52/62/66 1055x515x670 389 MPL 4DS 1100x560x680 Panda 12-4 HD 10.5 12.3 10.5 12.3 - - ±3V Kubota V 1505 1498 4 52/62/66 1170x540x680 488 MPL 4DS request 544 MPL 4DS request request MPL 4DS MPL 4DS request request MPL 4DS Panda 17-4 HD 14.7 17.5 14.7 17.5 - - ±3V Kubota V 2203 2197 4 53/63/67 1300x620x800 581 MPL 4DS request MPL 4DS request request MPL 4DS Panda 22-4 HD 18.6 21.9 18.6 21.9 - - ±3V Kubota V2403M 2434 4 53/63/67 1390x610x770 643 MPL 4DS 1390x600x760 643 MPL 4DS request request MPL 4DS Panda 30-4 HD 25.0 29.4 25.0 29.4 - - ±3V Kubota V3300 3318 4 request 1473x690x890 400 MPL 4DS request request MPL 4DS request request MPL 4DS Panda 40-4 HD - - 35.0 41.1 - - ±3V Kubota V3300T 3318 4 request 1560x710x950 867 MPL 4DS request request MPL 4DS request request MPL 4DS 40.0 47.0 ±3V Kubota V3800T 3769 4 request 1760x800x900 891 MPL 4DS request request MPL 4DS request request MPL 4DS Panda 60-4 DZ - - 50.4 59.3 - - ±3V Deutz BF4M2012C 4040 4 request 1500x790x1000 1298 MPL 6DS request request MPL 6DS request request MPL 6DS Panda 70-4 DZ - - 61.6 72.5 - - ±3V Deutz BF4M1013E 4764 4 request request request MPL 6DS request request MPL 6DS request request MPL 6DS Panda 85-4 DZ - - 73.6 86.6 - - ±3V Deutz BF4M1013EC 4764 4 request 1650x830x1100 1589 MPL 6DS request request MPL 6DS request request MPL 6DS Panda 110-4 DZ - - 92.8 109.2 - - ±3V Deutz 7146 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS Panda 130-4 DZ - - 111.2 130.8 - - ±3V Deutz BF6M1013EC 7146 6 request request request MPL 6DS request request MPL 6DS request request MPL 6DS Capsule Dimensions L x W x H (mm) Weight incl. Capsule (kg) Standard Capsule Type Standard Sound Insulation Capsule Dimensions L x W x H (mm) Weight incl. Capsule (kg) Standard Capsule Type Standard Sound Insulation Capsule Dimensions L x W x H (mm) Standard Sound Insulation Panda 50-4 HD BF6M1013E Standard Capsule Standard Sound Insulation Standard Capsule Type Weight incl. Capsule (kg) Capsule Dimensions L x W x H (mm) Sound Level N0. of Cylinders Displacement cm3 Engine Type Engine Manufactuter Voltage Tolerance Engine Revolutions Constant current rate (A) Weight incl. Capsule (kg) AGT 4000-24 Nominal voltage (DC) AGT Standard Generator with sound insulation capsule AGT 4000-12 Continuous Performance (kW) Panda AGT-DDC Battery Charging Generators with VCS Voltage Control System Nominal Performance (kW) Technical Data for Vehicle Generators ND Versions The ND versions of the Fischer Panda generators are an ideal for the priceconscious customer. The generators are identical to the NE models in respect of all main components, such as engine, generator, sound insulation casing, water-cooling etc. ND generators are not fitted with an electronic speed control. The voltage tolerance lies therefore within an acceptable range of ±8 %. This is similar to a land power connection. NE (and HD) Versions The Panda generator NE version has been fitted for many years with the tried and tested Voltage Control System (VCS) whereby the motor speed is progressively controlled. This has an enormously positive effect on the exhaust emission and ensures that the generator achieves up to 15 % more effective performance than other noncontrolled generators. The VCS adjusts the voltage with a tolerance of ±3 volts in the range up to 80% of the nominal performance. An external AC control box contains the VCS and the capacitors which are used for boosting the starting current (standard for Panda 5000 LPE up to Panda18 NE). 1) LP = Low Profile (especially low construction) Fischer Panda GmbH reserves the right to change technical information without prior notice. All performance data relates to air and water temperatures of 20°. Performance reduction (approx 1% per 100 m height and approx 2% per 5°C air temperature and approx. 1% per 1°C water temperature above 20°C). The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets. MPL 4DS 114 MPL 4DS 4 3.2 12 220 2400-3000 ±3V Kubota EA 300 309 1 55/65/69 750x420x420 119 MPL 3D request request MPL 4DS request 4 3.2 24 110 2400-3000 ±3V Kubota EA 300 309 1 52/62/67 750x420x420 119 MPL 3D request request MPL 4DS 1115x420x420 3.6 12 250 1800-2200 ±3V Kubota Z 482 479 2 52/62/67 750x505x615 189 GFK 4DS request request MPL 4DS request MPL 4DS 4DS 4DS 4DS AGT 5000-12 4.5 AGT 6000-24 5.5 4.8 24 170 2400-3200 ±3V Kubota Z 482 479 2 52/62/67 760x515x609 189 GFK 4DS request request MPL request MPL AGT 8000-24 8 6.4 24 220 2200-2600 ±3V Kubota D 722 719 3 53/63/67 860x505x635 216 GFK 4DS request request MPL 4DS request MPL AGT 12000 12 request request ±3V Kubota D 902 898 3 54/64/68 request GFK 4DS request request MPL 4DS request MPL 4DS AGT 14000 14 request request ±3V Kubota D 1105 1123 3 55/65/69 request GFK 4DS request request MPL 4DS request MPL 4DS request request ±3V Kubota V1505 1498 4 55/65/69 1100x550x690 MPL 4DS request request MPL 4DS request MPL 4DS 4DS request MPL 4DS 4DS request MPL 4DS AGT 16000 16 AGT 25000 25 request request ±3V Kubota V1505 T 1498 4 55/65/69 AGT 28000 28 request request ±3V Yanmar 4TNV88 2190 4 57/67/71 366 request MPL 4DS request request MPL request MPL 4DS request request MPL 13 Complete Program - Radiator Options AGT 28.000-96 AGT 25.000-72 AGT 16.000-48 AGT 14.000-48 AGT 12.000-48 AGT 8.000-24 AGT 6.000-24 AGT 5.000-12 AGT 4.000-24 AGT 4.000-12 Panda 130-4 DZ Panda 110-4 DZ Panda 85-4 DZ Panda 70-4 DZ Panda 60-4 DZ Panda 50-4 HD Panda 40-4 HD Panda 30-4 HD Panda 22-4 HD Panda 17-4 HD Panda 12-4 HD Panda 09-4 HD Panda 7,5-4 HD Panda 100 MB Panda 75 MB Panda 60 MB Panda 47 YA Panda 35 YA Panda 30 NE Panda 24 NE Panda 18 NE Panda 15.000 NE Panda 12.000 NE Panda 10.000 NE Panda 8.000 NE Panda 5000 LPE Panda 6000 ND Panda 4,5 ND Panda 12000i Panda 6000i Approx. Dimensions (L x B x H) mm Panda 4000i 1) Radiator Weight (dry) kg Roof mounted Radiators RD 1.2 RD-D: DC Roof mounted radiators RD 1.2 705 x 390 x 308 18 RD 2.2 930 x 515 x 317 28 RD 3.2 1055 x 515 x 312 32 RD 3.2 Trop 1055 x 515 x 352 x x x x x x x x x x x x x x x x x x x x x x x x RD-A: AC Roof mounted radiators RD6 / 2.2 RD3.3 - S350 1055 x 515 x 349 x x x x x x x x x x RD3.3 Trop - S350 1055 x 515 x 393 x x x x x x x x x x RD4.2 - FE040 659 x 610 x 370 32 x x x x x x x x x x RD16.2 - 2xFE040 1000 x 600 x 335 56 RD6/2.2 - 2xFE040 1350 x 550 x 360 57 RD6/2.2 - 2xFE045 1500 x 600 x 380 67 RD7.2 - FE071 1000 x 880 x 517 RD8.2 - FE063 1100 x 1080 x 537 RD P75 MB - 2xFE056 1900 x 990 x 531 x request RD P75 MB - FE080 on request x request RD P100 MB - 2xFE056 on request Side mounted Radiators x x x x x x x x x x x x x x x x x x x x RD2.2 x x x x request 1) Expansion Tank RV-D: Side-/underneath (chassis mounted) radiators DC x x x x RV1.2 615 x 330 x 214 13 RV2.2 760 x 450 x 224 21 RV3.2 900 x 450 x 224 24 x x x RV3.2 Trop 900 x 450 x 254 30 x x x x x x x x x x x x x x x x x x x RV-A: Side mounted Radiators AC RV 3.3 -S350 RV 3.3 Trop - S350 900 x 450 x 294 RV 5.2 - FE040 610 x 580 x 358 32 RV 13.160 - FE050 600 x 719 x 436 52 RV 6/2.2 - 2xFE040 1200 x 550 x 270 RV 6/2.2 - 2xFE045 1200 x 550 x 285 RV 14.120 - FE056 780 x 690 x 420 48 RV 14.160 - FE056 780 x 690 x 460 55 x x x x x x x x x x x x x x x x x x x x x x x x x x RV13.160 x x x x x x x x x x x x x x x x x x x x x x x RV3.2 x x 1000 x 800 x 420 63 1100 x 1000 x 420 78 RV P75 MB - 2xFE056 1900 x 1070 x 421 x RV P75 MB - FE080 1270 x 1100 x 455 x on request x x x RV 7.2 - FE071 1) x x RV 8.2 - FE063 RV P100 MB - 2xFE056 14 x 900 x 450 x 254 x x request request x request No value = on request. Fischer Panda GmbH reserves the right to change technical information without prior notice. 15 - Power - wherever you are Vehicle Generators - PVMV-N With integrated water-cooled primaryand secondary silencer. Suitable for stationary operation. The PVMV-N generator is a compact, standard solution for use in vehicle applications. Vehicle Generators PVK-U Generators housed in sound-insulated stainless steel capsules which are suitable for mounting externally beneath vehicles. Vehicle Generators PVK-UK Extremely compact and quiet generating set for vehicles featuring an integrated radiator. Suitable for mounting externally beneath vehicle. AGT DC Battery Charging Gene­rators Diesel battery-charging generators with 12, 24 or 48 V. The “AGT” technology is available from 2.5 to approx. 50 kW. Very efficient, compact with hidden cooling system and only available from Fischer Panda. AGT-DE Drive Generators Specially designed generators for dieselelectric drive systems. Highly efficiency and economical operation are particular characteristics of this generator. High-Performance Alternators Compact “High Output” alternators up to 3.2 kW, charging rate up to 260 A at 12 V DC. Available in 12 or 24 volt DC. Radiators and Installation Parts All vehicle and stationary generators are cooled either via an integrated or external DC/AC radiator. Solutions for specific customer requirements are possible. Installation parts for vehicle and marine generators are part of the standard product range. Whisperprop-System with DieselElectric Drive Complete drive system comprising generator and electric motor with control. The AGT-DE Generator and permanent magnet motor are extremely efficient and compact. Can completely replace existing on-board power systems when combined with a Victron Power System. Aziprop Shaft Saildrive AC Distribution Boxes A reliable and safe electrical supply is an absolute “must”. For a safe supply from multiple sources such as shore power, generator and inverter to each of the electrical consumers and serves as a central location for the AC system’s circuit breakers. Parallel Transfer Units These units are designed for synchronizing two Fischer Panda AC Generators in parallel so the load can be switched or combined to double the total power available. VICTRON Battery Chargers, Inverters and Combi-units up to 12,5 kW Fischer Panda in cooperation with Victron Energy. Victron inverters are available for 12, 24 and 48 V DC which can supply up to 12.5 kW parallel or be switched to a 3phase system. Professional charging units in 12, 24 and 48 V DC with up to 600A. Combi-units including high performance battery chargers are also available. Battery Monitors Easy to use and convenient battery monitoring. The charge level is displayed and prevents batteries from being unexpectedly discharged. This device can automatically start and stop the generator. System Control Board Features a touch screen and gives you full control of your on board devices and displays status including level indicators for batteries, supply, fuel and water levels of devices on board. Devices, including generator, can be switched “on” and “off” via the panel. vehicle_combined.indd stand:20100226 Marine Generators - PMS The world famous Panda Generators with sea-water cooled heat exchanger, dual-circuit cooling and wet exhaust.