SPECIFICATION SHEETS SUBJECT TO CHANGE WITHOUT NOTICE
UNDER CABINET SUBJECT TO CHANGE WITHOUT NOTICE
UNDER CABINET RANGE HOOD SPECIFICATIONS
PRH6-K Halogen lights only. This model not available with heat lamps. This model only available in Black, Biscuit, Gunsmoke, Stainless Steel, or White. Custom sizes not available.
The VP521 transition is available for top vent applications at an additional charge.
7”
7 ½”
10”
Connection Diagrams (24”, 30", 36", & 42" Widths)
”
3¼
Recommended Mounting Height*
Electrical
Electrical
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) K250 (Back Vent)
Volts
Amps
Hz
RPM
115 115
3.2 3.2
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 250 375 223 220 190 220 330 215 195 180
Minimum Round Duct Size 7" (38 in.2) 7" (38 in.2)
Sones# 7.4 7.4
All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1109A
C
UL R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS
SLH6-K Halogen lights only. This model not available with heat lamps. This model only available in Black, Biscuit, Gunsmoke, Stainless Steel, or White. Custom sizes not available.
The VP521 transition is available for top vent applications at an additional charge.
7”
7 ½”
10”
Connection Diagrams (24”, 30", 36", & 42" Widths)
”
3¼
Recommended Mounting Height*
Electrical
Electrical
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) K250 (Back Vent)
Volts
Amps
Hz
RPM
115 115
3.2 3.2
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 250 375 223 220 190 220 330 215 195 180
Minimum Round Duct Size 7" (38 in.2) 7" (38 in.2)
Sones# 7.4 7.4
All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1109A
C
UL R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS NP9/NPH9/PR9/PRH9/SL9/SLH9 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. 12”
12”
9”
4”
WID TH
12”
9”
2”
WID TH
”
21
NP9/NPH9
9”
2”
WID TH
”
21
PR9/PRH9
SL9/SLH9
Connection Diagram (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole Electrical 3 ¼”
Recommended Mounting Height*
5 ¼” Vent Holes
1 ¾”
6” Outlet
Soffit
8” Outlet
Electrical
9”
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 48" Widths) 10” Round
7 �⁄��”
5 ½”
Wall Side
Cabinets
Centerline of Hood
Centerline of Hood
7 �⁄��”
”
21
24”-27”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
*Exceeding recommended mounting height may compromise performance.
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round
Connection Diagram (48” Width) 11”
11”
5 ½”
12” Round
5 ½”
Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS F/XR9/XRH9 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. 12”
12”
9”
”
2¼
WID TH
9”
”
2¼
¾” O
ffse t
WID TH
”
21
F (Fluorescent Lights Only)
XR9/XRH9
Connection Diagram (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole Electrical 3 ¼”
Recommended Mounting Height*
5 ¼” Vent Holes
1 ¾”
6” Outlet
Soffit
8” Outlet
Electrical
9”
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 48" Widths) 10” Round
7 �⁄��”
5 ½”
Wall Side
Cabinets
Centerline of Hood
Centerline of Hood
7 �⁄��”
”
21
24”-27”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
*Exceeding recommended mounting height may compromise performance.
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round
Connection Diagram (48” Width) 11”
11”
5 ½”
12” Round
5 ½”
Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. The F hood is available with fluorescent lights only (one per single or dual blower) and the XR9/XRH9 is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
UNDER CABINET RANGE HOOD SPECIFICATIONS SL6/SLH6 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models. ” 12
2”
6”
9”
WID TH
6”
19
½”
SL6/SLH6 Connection Diagram (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole Electrical 3 ¼”
Recommended Mounting Height*
5 ¼” Vent Holes
1 ¾”
6” Outlet
Soffit
8” Outlet
Electrical
600 CFM B200 Dual Blower
(Top View)
(Top View)
Connection Diagram (42” - 48" Widths) 10” Round
7 �⁄��”
5 ½”
6”
8’ Ceiling
300 CFM B100 Single Blower
Wall Side
Cabinets
Centerline of Hood
Centerline of Hood
7 �⁄��”
9”
Sloped Bottom
21”-24”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
*Exceeding recommended mounting height may compromise performance.
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round
Connection Diagram (48” Width) 11”
11”
5 ½”
12” Round
5 ½”
Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
WALL MOUNT SUBJECT TO CHANGE WITHOUT NOTICE
WALL MOUNT RANGE HOOD SPECIFICATIONS NP18/NPH18/NPX18/NPXH18/PR18/PRH18/PRX18/PRXH18/SL18/SLH18/SLX18/SLXH18 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models (included on NP Series). X in part number indicates 27” depth. 12”
12”
12”
18”
18”
18”
6”
4”
4”
4” - 2 7” NP X - 2 P N
WID TH
4” - 2 7” PR X - 2 R P
WID TH
NP(X)18/NP(X)H18 (Includes WBAR warming light bar)
PR(X)18/PR(X)H18
SL(X)18/SL(X)H18
Connection Diagrams (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole
6” Outlet
3 ¼”
Recommended Mounting Height*
5 ¼”
Optional Duct Cover
Vent Holes
1 ¾” Electrical
8” Outlet
Electrical
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 60" Widths) 10” Round
7 �⁄��”
5 ½”
Wall Side
18”
Centerline of Hood
Centerline of Hood
7 �⁄��”
4” - 2 7” SL X - 2 L S
WID TH
30”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower)
*Exceeding recommended mounting height may compromise performance. 10” OR 12” Round
Connection Diagram (48” - 66" Widths) 11”
11”
5 ½”
12” Round
5 ½”
Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units
Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
VP562/VP563 transition centers outlet over top of hood
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS DA18/DAH18/PWV18/PWVH18/XR18/XRH18/XRX18/XRXH18 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models. X in part number indicates 27" depth. 12”
12”
12”
18”
3”
18”
3”
1½
” Off set
WID TH
18”
” Off set
WID TH
”
24
1” O
4”
1½
WID TH
”
24
DA18/DAH18 PWV18/PWVH18 Connection Diagrams (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole Electrical 3 ¼”
4” - 2 7” XR X - 2 XR
XR(X)18/XR(X)H18 Recommended Mounting Height*
5 ¼” Vent Holes
1 ¾”
6” Outlet
ffse t
8” Outlet
Electrical Centerline of Hood
Centerline of Hood
300 CFM B100 Single Blower
600 CFM B200 Dual Blower
(Top View)
(Top View)
Connection Diagram (42” - 60" Widths) 7 �⁄��” 5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
1 ¾”
1 �⁄�” Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower)
10” OR 12” Round
Connection Diagram (48” - 66" Widths) 11”
11”
5 ½”
12” Round
5 ½”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side Vent Holes
1 ¾”
*Exceeding recommended mounting height may compromise performance.
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0909A
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS CX30/CXH30/DA30/DAH30/PWV30/PWVH30/SL30/SLH30 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models. 12”
12”
30”
3”
30”
3”
1½
” Off set
WID TH
12”
12”
CX30/CXH30
” Off set
4”
1½
3”
1½ WID TH
”
24
30”
30”
” Off set
WID TH
”
24
DA30/DAH30
WID TH
”
24
PWV30/PWVH30
SL30/SLH30
Connection Diagrams (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole Electrical 3 ¼”
Recommended Mounting Height*
5 ¼” Vent Holes
1 ¾”
6” Outlet
”
24
30”
8” Outlet
Electrical Centerline of Hood
Centerline of Hood
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
30”
Connection Diagram (42” - 60" Widths) 7 �⁄��” 5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
*Exceeding recommended mounting height may compromise performance.
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round
Connection Diagram (48” - 66" Widths) 11”
11”
5 ½”
12” Round
5 ½”
Wall Side Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
VP562/VP563 transition centers outlet over top of hood
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS CW/CWH “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models.
12” WI
DT H
24”
CW/CWH Connection Diagrams (30” - 48” Widths) 1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole
5 ¼”
1 ¾” Electrical
6” Outlet
3 ¼”
Cabinets of Soffit
Vent Holes 8” Outlet
Electrical
12”
Centerline of Hood
Centerline of Hood
300 CFM B100 Single Blower
600 CFM Dual Blower
(Top View)
(Top View)
8’ Ceiling
5 ¼”
Recommended Mounting Height*
30”
Connection Diagram (42” - 60" Widths) 7 �⁄��” 5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
*Exceeding recommended mounting height may compromise performance.
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower) 10” OR 12” Round
Connection Diagram (48” - 66" Widths) 11”
11”
5 ½”
12” Round
5 ½”
Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
VP562/VP563 transition centers outlet over top of hood
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS TLH (Halogen Lights) Not available with heat lamps. TILT (Fluorescent Light) Not available with heat lamps. Cut Out For Top Vent Cut Out For Back Vent
Door Panel Must Be Supplied By Cabinet Maker
Hinge 1” From Top
H DT WI
24 ¼”
Door Panel Can Overhang
24 ¼”
11
21 Bevel Minimum1 ¼” Long ¼” Or Less o
Mounting Holes For Door Panel
¼” 8¼
Door Panel Specifications
TLH/TILT
”
Recommended Mounting Height*
Connection Diagrams (30” - 48” Widths) 5 ¼”
1 ¾”
1 3⁄8”
Wall Side
5 ½”
Wall Side
Vent Hole
5 ¼”
1 ¾” Electrical
6” Outlet
3 ¼”
Cabinets or Soffit
Vent Holes 8” Outlet
Electrical
24 ¼”
Centerline of Hood
Centerline of Hood
600 CFM B200 Dual Blower
(Top View)
(Top View)
Channel For Mounting Strip
36”
13 ½”
13 ½”
23 ¾”
10 ¾” 24 ¼”
24 ¼”
10 ¾”
12 ½” Cut Out For Back Vent
8’ Ceiling
300 CFM B100 Single Blower
11 ¼” Left End
Back View of Hood
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual
Volts
Amps
Hz
RPM
115 115
1.5 2.9
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 300 450 273 245 225 600 900 531 480 430
Minimum Round Duct Size 6" (28 in.2) 8" (50 in.2)
Sones# 5.4 6.5
* Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0409A
C
UL R
US
EURO-STYLE WALL MOUNT SUBJECT TO CHANGE WITHOUT NOTICE
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS PD14/PDH14/SLD14/SLDH14 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 10”
10”
OPTIONAL DUCT COVER
HEIGHT
OPTIONAL DUCT COVER
10”
8”
2 5⁄
HEIGHT
10”
3”
14”
14”
WID TH
WID TH
”
21
”
21
PD14/PDH14 SLD14/SLDH14 30” model is limited to B100 single blower only Connection Diagram (30" - 48" Widths) 1 ¾”
1 7⁄8”
Wall Side
Recommended Mounting Height
Blower Exhaust Outlet
Vent Hole
6" Round
14"
Electrical
5 ¼” 6" Outlet
Optional Duct Cover or Soffit
5"
14”
Centerline Of Hood
(Front View) 8’ Ceiling
300 CFM B100 Single Blower (Top View)
24”
Connection Diagram (36”- 48” Widths) 5 ½”
Wall Side
5 ¼”
Blower Exhaust Outlet
1 ¾”
36”
8" Round
Vent Holes
5" 14"
8” Outlet
Electrical Centerline of Hood
(Front View)
600 CFM B200 Dual Blower
*Exceeding recommended mounting height may compromise performance.
(Top View)
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual
Volts
Amps*
Hz
RPM
115 115
1.5 2.9
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 300 450 273 245 225 600 900 531 480 430
Minimum Round Duct Size 6" (28 in.2) 8" (50 in.2)
Sones# 5.4 6.5
* Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS EP(X)18/EP(X)H18/NEP(X)18/NEP(X)H18/SEP(X)18/SEP(X)H18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 12”
12”
OPTIONAL DUCT COVER
HEIGHT
OPTIONAL DUCT COVER
18”
4”
WID TH
12”
OPTIONAL DUCT COVER
18”
4”
WID TH
4” - 2 7” EP X - 2 P E
EP(X)18/EP(X)H18
12” HEIGHT
12”
HEIGHT
12”
18”
3”
WID TH
” 24 ” P - - 27 E N PX NE
NEP(X)18/NEP(X)H18
” 24 ” P - 27 SE PX SE
SEP(X)18/SEP(X)H18
(X) in part number indicates 27” depth Connection Diagram (36" - 48" Widths) 5 ½”
Wall Side
Recommended Mounting Height*
5 ¼”
Optional Duct Cover
Vent Holes
1 ¾”
18”
8” Outlet
Electrical
8’ Ceiling
Centerline of Hood
600 CFM B200 Dual Blower (Top View)
30”
Blower Exhaust Outlet 9"
8" Round
36”
18"
*Exceeding recommended mounting height may compromise performance.
(Front View)
Electrical/Mechanical Specifications For Blower Units Model B200 Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 600 900 531 480 430
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.5
* Add 0.5 amp for each halogen light. Hood is available with a single fluorescent light or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS EP(X)T18/EP(X)TH18/NEP(X)T18/NEP(X)TH18/SEP(X)T18/SEP(X)TH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover sold separately). Optional duct covers available in standard and custom sizes. HEIGHT
18”
4”
WID TH
14”
26”
OPTIONAL DUCT COVER
18”
4”
WID TH
” 24 ” T - 27 EP XT EP
EP(X)T18/EP(X)TH18
26”
OPTIONAL DUCT COVER
HEIGHT
14”
26”
HEIGHT
14”
OPTIONAL DUCT COVER
18”
3”
WID TH
4” - 2 7” PT - 2 NE PXT NE
NEP(X)T18/NEP(X)TH18
4” - 2 7” PT - 2 SE PXT SE
SEP(X)T18/SEP(X)TH18
(X) in part number indicates 27” depth Connection Diagram (42" - 66" Widths)
Recommended Mounting Height 10"
12 �⁄�”
9 �⁄�”
Wall Side
1 ¾”
Optional Duct Cover
8 ½”
Electrical (2)
18”
18"
10" Outlet Centered On Hood Top
900 CFM B200 Dual & B100 Single Blower (Top View)
VP562 Standard Transition Installed (Front View)
Connection Diagram (54” - 66” Widths)
8’ Ceiling
Centerline Of Hood
30”
12"
1 ¾” 16 ½”
5 ½”
7 ½"
Wall Side
7"
1 ¾”
Electrical (2)
12" Outlet Centered On Top Of Hood
18"
36”
Centerline Of Hood
1200 CFM Double B200 Dual Blowers
VP563 Standard Transition Installed (Front View)
(Top View) The transition shown (VP562 & VP563) is installed in the hood at the factory as a standard item. It will be located in the exact center of the duct cover (left to right & front to rear).
Duct Cover (Top of Hood)
*Exceeding recommended mounting height may compromise performance.
10" Dia. or 12" Dia. Transition Location "Centered"
Electrical/Mechanical Specifications For Blower Units Model B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115
4.4 5.8
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 900 1350 804 725 655 1200 1800 1062 960 860
Minimum Round Duct Size 10" (79 in.2) 12" (113 in.2)
Sones# 6.3 6.6
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one for each single or dual blower) or with halogen lights (3 lights: 42" - 53", 4 lights: 54" - 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
CONTEMPORARY WALL MOUNT SUBJECT TO CHANGE WITHOUT NOTICE
WALL MOUNT RANGE HOOD SPECIFICATIONS
The VP521 transition is available for top vent applications at an additional charge.
CWEH6-K Equipped with halogen lighting. This model not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Available in painted and stainless steel finishes. Available in 30", 36", 42", and 48" widths only.
OPTIONAL DUCT COVER
7”
7 ½”
”
10”
CWEH6-K
Connection Diagram
Recommended Mounting Height*
3¼
(Top View)
*Exceeding recommended mounting height may compromise performance.
(Front View)
Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent)
Volts
Amps*
Hz
RPM
115
2.2
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 250 375 223 220 190
Minimum Round Duct Size 7" (38 in.2)
Sones# 7.4
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" & 36", 3 lights: 42" & 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS GTH Equipped with halogen lighting. These models not available with heat lamps. Only available in stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Pot rail included. ”
12
The VP521 transition is available for top vent applications at an additional charge.
OPTIONAL DUCT COVER
7”
12
”
10”
”
½ 16
7 ½”
16
”
1 ¾” ”
36
21
”
”
10”
GTH (36” Width Only)
3¼
Connection Diagram 1”
Recommended Mounting Height*
3 ¼” x 10” Outlet
Wall Side
Optional Duct Cover
4 ½” 10”
Centerline of Hood
8’ Ceiling
Electrical 24”
(Top View) Outlet
36”
*Exceeding recommended mounting height may compromise performance.
6"
NOTE: DUCT COVER EXTENDS 4” INTO TOP OF HOOD.
(Front View)
Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent)
Volts
Amps
Hz
RPM
115
3.2
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 250 375 223 220 190
Minimum Round Duct Size 7" (38 in.2)
Sones# 7.4
All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS
Space Between Duct Covers
OPTIONAL DUCT COVERS
OPTIONAL DUCT COVER
CWEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover(s) (sold separately). Optional duct covers are available in standard and custom sizes.
Width A 4"
CWEH9-348
8"
CWEH9-354
10"
CWEH9-360
12"
CWEH9-448
10"
CWEH9-454
10"
CWEH9-460
12"
CWEH9-466
14"
Model CWEH9-342
Connection Diagram (30”- 48” Widths) Connection Diagram (30”- 54” Widths)
Recommended Mounting Height*
Motor Cooling Vent
Electrical
Electrical
6" Round
Motor Cooling Vent
8" Round
300 CFM B100 Single Blower
600 CFM B200 Dual Blower
(Top View)
(Top View)
Connection Diagram (42”- 60” Widths)
Model
Motor Cooling Vent
8" Round
6" Round
900 CFM B200 Dual & B100 Single Blower (Top View)
Width A
Width B
CWEH9-342
8"
8"
CWEH9-348
10"
10"
CWEH9-354
11"
11"
CWEH9-360
12"
12"
Outlet Spacing for 900 CFM Models
Connection Diagram (48”- 66” Widths)
Electrical (2) Motor Cooling Vent
8" Round
8" Round
Model
Width A
Width B
CWEH9-448
11"
11"
CWEH9-454
11"
11"
CWEH9-460
12"
12"
CWEH9-466
13"
13"
*Exceeding recommended mounting height may compromise performance.
1200 CFM Double B200 Dual Blowers
Outlet Spacing for 1200 CFM Models Electrical/Mechanical Specifications For Blower Units
(Top View)
Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS CWLH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers are available in standard and custom sizes s (sold separately). Galley rail included. od Ho ds o FM Ho 0C M 90 00CF r fo 12 ide or ”W e f 26 “ Wid 34
12
” 12
”
OPTIONAL DUCT COVER
4 ½”
12
”
4 ½”
OPTIONAL DUCT COVER
4 ½”
4 ½”
”
5¾
hs idt 8” Widths 4 & 2”, ” W ”, 4 48 36 2”, & , ” 4 0 - 3 6”, FM - 3 0 C 0CFM 0 3 60
9” 21
”
3”
hs idt s ” W idth 0 & 6 66” W 4”, -5 ,& M - 60” F 0C M 90 00CF 12
”
5¾ 9”
21
”
3”
Recommended Connection Diagram (30”- 48” Widths) Connection Diagram (36”- 48” Widths) Mounting Height* 1 ¾” 5 ¼”
½”
1 ¾”
Wall Side
4 ½”
Wall Side 5 ¼”
Vent Hole
Vent Holes
Electrical 1 ½”
6” Outlet
Optional Duct Cover
5 ¼”
Centerline of Hood
Centerline of Hood
8” Outlet
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (54”- 60” Widths) 7 �⁄��”
1 ¾”
1 �⁄�”
10” Round
Vent Holes
10” Round
17 ½”
36”
Electrical (2)
5 ¼”
6" Outlet
Centerline of Hood
8" Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower VP562 Transition (Optional) for B300 (B200 Dual & B100 Single Blower)
(Top View)
11”
12” Round
11” 5 ½”
5 ½”
12” Round
Wall Side Vent Holes
1 ¾”
16 ½”
8" Outlet
5 ¼”
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) for B400 (For Double B200 Dual Blowers)
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
*Exceeding recommended mounting height may compromise performance. 10” OR 12” Round
Connection Diagram (60”- 66” Widths)
8" Outlet
27”
7 �⁄��”
5 ½”
Wall Side
9”
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
VP562/VP563 transition centers outlet over top of hood
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS XLH12 Equipped with halogen lighting. This model not available with heat lamps. Only available in stainless steel. Optional duct covers/finished duct available in standard and custom sizes (sold separately). ”
10
HOOD WITH OPTIONAL ROUND DUCT COLLARS AND FINISHED ROUND DUCT
DUCT COVERS/FINISHED ROUND DUCT AND DUCT COLLARS PRICED SEPARATELY
10
”
1”
HOOD WITH OPTIONAL 10” X 10” DUCT COVER
12”
2”
15” ”
30
21
”
HOOD WITH OPTIONAL SQUARE DUCT COLLARS AND FINISHED ROUND DUCT
”
6 &3
2” LIP MAY BE BRASS, COPPER, STAINLESS STEEL, OR MIRROR STAINLESS STEEL
XLH12 Connection Diagram (30” & 36” Widths) 1 ¾”
4 ½”
Wall Side
Blower Exhaust Outlet
5 ¼”
Recommended Mounting Height*
8" Round
Vent Holes
5 ¼”
12"
8” Outlet
Electrical
Optional Finished Duct Pipe
3"
Centerline of Hood
12”
(Front View)
NOTE: WHEN PRICING CUSTOM FINISHED ROUND DUCT, INCLUDE THE 3” FINISHED ROUND THAT EXTENDS INTO TOP OF HOOD AND 1” THAT EXTENDS INTO CEILING (4” DUCT (REQUIRES TWO TOTAL.) TOTAL OVERALL HEIGHT CANNOT EXCEED 60” (10’ 8” CEILING). DUCT COLLARS) ROUND DUCT COLLAR SQUARE DUCT COLLAR Crimped Galvanized Connector
3”
1” Into Ceiling
10
12” For 7’ Ceiling 24” For 8’ Ceiling 36” For 9’ Ceiling
Overall Height Of Finished Round Duct
24”
3”
”
10
10
”
8’ Ceiling
(Top View)
”
”
10
36”
10” x 10” SQUARE DUCT COVER
3” Into Hood
10”
10”
HEIGHT
8” ROUND NOTE: TOP END OF FINISHED ROUND DUCT IS CRIMPED TO ALLOW FOR DUCT CONNECTION IN THE CEILING (CRIMP IS NOT INCLUDED IN THE OVERALL HEIGHT OF THE FINISHED ROUND DUCT).
CUSTOM SIZES ALSO AVAILABLE
*Exceeding recommended mounting height may compromise performance. NOTE: DUCT PIPE EXTENDS 3” INTO TOP OF HOOD AND 1” INTO CEILING.
Electrical/Mechanical Specifications For Blower Units Model B200 Dual
Volts
Amps
Hz
RPM
115
3.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 600 900 531 480 430
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.5
Hood has two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
WALL MOUNT RANGE HOOD SPECIFICATIONS ZTH Equipped with halogen lighting. These models not available with heat lamps. Only available in stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes (sold separately). Fixed pot rails included. OPTIONAL ”
12
”
12
OPTIONAL DUCT COVER
”
12
OPTIONAL DUCT COVER
12
12
12
”
”
”
”
18
”
1”
”
”
18
”
34 16
”
1”
14 3⁄8”
” 36
24
”
”
1” 14 �⁄�”
DUCT COVER
12
16
”
16
”
18
16
”
28
OPTIONAL DUCT COVER
14 �⁄�”
”
42
24
1”
”
48
24
”
”
54
14 3⁄8”
”
24
”
ZTH Connection Diagram (36”- 48” Widths) 1 ¾”
4 ½”
Wall Side
5 ¼”
Blower Exhaust Outlet
Vent Holes
5 ¼”
Recommended Mounting Height*
8” Round Optional Duct Cover
14 �⁄�”
8” Outlet
Electrical
14 �⁄�”
9”
Centerline of Hood
(Front View)
600 CFM B200 Dual Blower
8’ Ceiling
(Top View)
Connection Diagram (54” Width) 10” Round
Wall Side
6 �⁄��"
8 �⁄��"
4 ½"
1 �⁄�"
30”
10” Round
1 ¾" 36”
17 ½”
Vent Holes Electrical (2)
5 ¼"
6" Outlet
Centerline Of Hood
8" Outlet
8” Round
900 CFM B200 Dual Blower & B100 Single Blower
8” Round
6” Round
VP562 Transition (Optional) For B300 For B200 Dual and B100 Single Blower
(Top View) Blower Exhaust Outlets
8” Round
2”
*Exceeding recommended mounting height may compromise performance. NOTE:DUCT COVER EXTENDS 5 3/8” INTO TOP OF HOOD.
10”ROUND OR 12” 10” Round
6” Round
14 �⁄�” 9”
VP562 transition centers outlet over top of hood
(Front View)
Electrical/Mechanical Specifications For Blower Units Model B200 Dual B200 Dual & B100 Single
Volts
Amps
Hz
RPM
115 115
4.9 6.4
60 60
1550 1550
CFM CFM CFM Minimum Round • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 600 900 531 480 430 8" (50 in.2) 900 1350 804 725 655 VP562: 10" (79 in.2)
Sones# 6.5 6.3
Hood has four halogen lights (one light in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
RETRO STYLE SUBJECT TO CHANGE WITHOUT NOTICE
RETRO STYLE WALL MOUNT RANGE HOOD SPECIFICATIONS AH12 Halogen lights only. This model is not available with heat lamps. Painted round duct and ceiling collar are priced separately. 15”
16”
4”
12”
WID TH
Includes side wing panels and splash panel. Splash panel is 30” tall x hood width.
12”
”
27 2” x 2” Clipped Corners
AH12 Recommended Mounting Height*
Connection Diagram (30”- 48” Widths) 30” Model is Limited to B100 Single Blower Only Blower Exhaust Outlet
1 ¾”
1 7⁄8”
Wall Side
Optional Painted Round Duct
6" Round
Vent Hole
2"
Electrical
5 ¼” 6" Outlet
12”
12"
Centerline Of Hood
(Front View)
300 CFM B100 Single Blower
8’ Ceiling
(Top View)
Connection Diagram (36”- 48” Widths) 5 ½”
Wall Side
Blower Exhaust Outlet
5 ¼”
8" Round
Vent Holes
1 ¾”
2"
36”
8” Outlet
Electrical
33”
12"
Centerline of Hood
(Front View)
*Exceeding recommended mounting height may compromise performance.
Optional Ceiling Collars
NOTE: DUCT PIPE EXTENDS 2” INTO TOP OF HOOD AND 1” INTO CEILING.
600 CFM B200 Dual Blower (Top View)
Optional Painted Round Duct Crimped Galvanized Connector 1” Into Ceiling 11”
3” For 7’ Ceiling 15” For 8’ Ceiling 27” For 9’ Ceiling
Overall Height Of Finished Round Duct
6 ¼” Diameter Opening
ARC6
2” Into Hood
11”
8 1/4” Diameter Opening
ARC8
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual
Volts
Amps*
Hz
RPM
115 115
1.5 2.9
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 300 450 273 245 225 600 900 531 480 430
Minimum Round Duct Size 6" (28 in.2) 8" (50 in.2)
Sones# 5.4 6.5
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0908A
C
UL R
US
RETRO STYLE UNDER CABINET RANGEHOOD SPECIFICATIONS CLH9 Halogen lights only. 12”
9”
2”
½” Offset WID TH
”
21
CLH9 Connection Diagram (30” - 48” Widths) 5 ¼”
1 ¾”
1 �⁄�”
Wall Side
5 ½”
Wall Side
Vent Hole
5 ¼” Vent Holes
1 ¾” Electrical
6” Outlet
3 ¼”
Recommended Mounting Height* Soffit
8” Outlet
Electrical
Cabinets
Centerline of Hood
Centerline of Hood
9”
600 CFM B200 Dual Blower
(Top View)
(Top View)
8’ Ceiling
300 CFM B100 Single Blower
Connection Diagram (42” - 48” Widths) 7 �⁄��” 5 ½”
Wall Side
10” Round
7 �⁄��”
24”-27”
10” Round
1 ¾”
1 �⁄�”
36”
Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
*Exceeding recommended mounting height may compromise performance.
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower)
10” OR 12” Round
Connection Diagram (48” Width) 11”
11”
5 ½”
12” Round
5 ½”
Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Wall Side
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115 115
1.5 2.9 4.4 5.8
60 60 60 60
1550 1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 5.4 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
ISLAND SUBJECT TO CHANGE WITHOUT NOTICE
ISLAND RANGE HOOD SPECIFICATIONS ISF18/ISFH18/ISL18/ISLH18/IXR18/IXRH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12 Bo ” Les tto s T m W han idt h
”
15
12 Bo ” Les tto s T m W han idt h
”
15
18”
18” 3”
1½
”O
WI
3”
ffse t
DT H
12 Bo ” Les tto s T m W han idt h
”
15
” 27
WI
DT H
ISF18/ISFH18
ISL18/ISLH18
18”
4”
1” O
ffse t
WI
1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View)
”
27
DT H
”
27
IXR18/IXRH18 Connection Diagram (36” - 54”)
Connection Diagram (60” - 66”)
Centerline of Hood
¾”
2 �⁄�”
5” x 16” Exhaust Opening
Electrical (2) Vent Holes
Vent Holes
¾”
8" Transition Opening (2) 9" Above Top Of Hood
Centerline Of Hood
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
30”
36”
9"
8" Round
Optional Duct Cover
5" x 16" Exhaust Opening (2)
18”
8” Transition Opening 9” Above Top of Hood
Electrical
2 �⁄�”
Centerline Of Hood
11"
8’ Ceiling
Centerline of Hood
11"
Recommended Mounting Height*
8" Round
9"
18"
5"
*Exceeding recommended mounting height may compromise performance.
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
ISLAND RANGE HOOD SPECIFICATIONS PL18/PLH18/PLX18/PLXH18/PY18/PYH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12”
12 Bo ” Les tto s T m W han idt h
”
15
18”
18”
6”
3” WI
DT H
WI
1 ½”
Connection Diagram (36” - 54”)
2 �⁄�”
11"
2 �⁄�”
Centerline Of Hood
8” Transition Opening 9” Above Top of Hood
Electrical
1 ½” �⁄��” Dia. Island Duct Cover Mounting Holes (Top View)
”
27
PY18/PYH18
Connection Diagram (60” - 66”)
Centerline of Hood 5” x 16” Exhaust Opening
ffse t
DT H
“X” in model number indicates 30” depth
¾”
”O
7” -2 ” PL - 30 X PL
PL(X)18/PL(X)H18
Centerline of Hood
1½
Electrical (2) Vent Holes
Vent Holes
11" Optional Duct Cover
5" x 16" Exhaust Opening (2)
¾”
18”
8" Transition Opening (2) 9" Above Top Of Hood
Centerline Of Hood
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
8’ Ceiling
550 CFM T200 Dual Blower
9"
8" Round
Recommended Mounting Height*
30”
36”
8" Round
9"
18"
5"
*Exceeding recommended mounting height may compromise performance.
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
ISLAND RANGE HOOD SPECIFICATIONS ICX30/ICXH30/ISF30/ISFH30 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12 Bo ” Les tto s T m W han idt h
”
15
12 Bo ” Les tto s T m W han idt h
”
15
30”
30”
1½
”O
WI
3”
DT H
”O
WI
2
1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View)
Connection Diagram (36” - 54”)
11”
5" x 16" Exhaust Opening
Vent Holes 7 ¾"
”
27
ISF30/ISFH30
Connection Diagram (60” - 66”)
Centerline Of Hood
Centerline Of Hood
ffse t
DT H
7”
ICX30/ICXH30
Electrical
1½
ffse t
11”
5” x 16” Exhaust Opening (s)
Centerline of Hood
8" Transition Opening 3” Below Top of Hood
Vent Holes
30”
8” Transition Opening (2) 3” Below Top of Hood
7 ¼” Electrical (2)
Centerline of Hood
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View) 3"
8" Round
Recommended Mounting Height*
8’ Ceiling
3”
30”
36”
8" Round 30"
*Exceeding recommended mounting height may compromise performance.
9"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
ISLAND RANGE HOOD SPECIFICATIONS ISL30/ISLH30/PY30/PYH30 “H” in part number indicates halogen lighting. These models not available with heat lamps. 12 Bo ” Les tto s T m W han idt h
”
15
12 Bo ” Les tto s T m W han idt h
” 15
30”
30”
3”
3”
DT H
DT H
”
27
1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View)
Connection Diagram (36” - 54”)
Centerline Of Hood Vent Holes 7 ¾"
”
27
PY30/PYH30
Connection Diagram (60” - 66”)
Centerline Of Hood
11”
5" x 16" Exhaust Opening
ffse t
WI
ISL30/ISLH30
Electrical
”O
11”
8” Transition Opening (2) 3” Below Top of Hood
7 ¼” Vent Holes Electrical (2)
Centerline of Hood
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
30”
36”
3"
8" Round
30”
5” x 16” Exhaust Opening (s)
Centerline of Hood
8" Transition Opening 3” Below Top of Hood
Recommended Mounting Height*
8’ Ceiling
WI
1½
8" Round 30"
*Exceeding recommended mounting height may compromise performance.
9"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
ISLAND RANGE HOOD SPECIFICATIONS CO/COH “H” in part number indicates halogen lighting. This model not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. ”
20”
14
OPTIONAL DUCT COVER
” 14
2 OPTIONAL DUCT COVERS
20”
3”
3” 12”
WI
1½
”O
DT H
1½
WI
ffse t
DT H
”O
ffse t
12”
”
27
1 ½”
”
1 ½” 5⁄16” Dia.
27
CO/COH
Island Duct Cover Mounting Holes (Top View)
Connection Diagram (36” - 54”)
Connection Diagram (60” - 66”)
Recommended Mounting Height*
Centerline of Hood
11”
Centerline of Hood
¾”
2 �⁄�”
5” x 16” Exhaust Opening
Centerline of Hood
8” Transition Opening 9” Above Top of Hood
Electrical Vent Holes
11”
¾”
Electrical (2) Vent Holes
Optional Duct Cover
5” x 16” Exhaust Opening (2) 8” Transition Opening (2) 9” Above Top of Hood
2 �⁄�”
12”
550 CFM T200 Dual Blower
1100 CFM T2+ 200 Dual Blowers
(Top View)
(Top View)
8’ Ceiling
Centerline of Hood 30”
9"
8" Round
8" Round
36”
9" 12"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0209A
C
UL R
US
EURO-STYLE ISLAND SUBJECT TO CHANGE WITHOUT NOTICE
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS ISD18/ISDH18/PYD18/PYDH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 12”
12”
OPTIONAL DUCT COVER
HEIGHT
OPTIONAL DUCT COVER
12”
18”
3”
WID TH
HEIGHT
12”
18”
4”
WID TH
” 27
”
27
1 ½” �⁄��” Dia.
1 ½” Island Duct Cover Mounting Holes (Top View)
ISD18/ISDH18
PYD18/PYDH18
Connection Diagram (36" - 48" Widths)
Recommended Mounting Height*
Centerline Of Hood
Optional Duct Cover
5" x 16" Exhaust Opening
Centerline Of Hood
18”
7 ¾"
Electrical
8" Transition Opening
8’ Ceiling
Vent Holes
550 CFM T200 Dual Blower (Top View)
8" Round
30”
8" Round 36”
18"
9"
5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS EPI18/EPIH18/SEPI18/SEPIH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 12”
12”
12”
OPTIONAL DUCT COVER
HEIGHT
OPTIONAL DUCT COVER
18”
4”
WID TH
HEIGHT
12”
18”
3”
WID TH
”
30
”
30
1 ½” �⁄��” Dia.
1 ½” Island Duct Cover Mounting Holes (Top View)
EPI18/EPIH18
SEPI18/SEPIH18
Connection Diagram (36" - 48" Widths)
Recommended Mounting Height*
Centerline Of Hood
Optional Duct Cover
5" x 16" Exhaust Opening
Centerline Of Hood
18”
7 ¾"
Electrical
8" Transition Opening
8’ Ceiling
Vent Holes
550 CFM T200 Dual Blower
30”
(Top View)
8" Round
8" Round 36”
18"
9"
5"
*Exceeding recommended mounting height may compromise performance.
16"
VP565 Stadard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS EPIT18/EPITH18/SEPIT18/SEPITH18 “H” in part number indicates halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. 15”
15”
OPTIONAL DUCT COVER
HEIGHT
OPTIONAL DUCT COVER
18”
4”
WID TH
15” HEIGHT
15”
18”
3”
WID TH
”
30
1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View)
EPIT18/EPITH18
”
30
SEPIT18/SEPITH18
Connection Diagram (48" - 66" Widths)
Recommended Mounting Height*
Centerline of Hood
Optional Duct Cover
Electrical (2) Vent Holes
7 ¾”
8” Blower Outlets
Centerline of Hood
12" Transition Opening 2 ¼” Above Top of Hood
18”
8’ Ceiling
10 ½”
1100 CFM T400 Cluster Blower
30”
(Top View) 2 ¼”
12" Round
12" Round
36”
11 ¼"
8" Round
18”
8" Round
*Exceeding recommended mounting height may compromise performance.
8" Round
VP564 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T400 Island Cluster
Volts
Amps*
Hz
RPM
115
5.8
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 1100 1800 998 855 774
Minimum Round Duct Size 12" (13 in.2)
Sones# 6.4
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (two in front, two in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
CONTEMPORARY ISLAND SUBJECT TO CHANGE WITHOUT NOTICE
ISLAND RANGE HOOD SPECIFICATIONS
CIEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover(s) (sold separately). Optional duct covers available in standard and custom sizes.
OPTIONAL DUCT COVER
2 OPTIONAL DUCT COVERS
CIEH9 (1100 CFM)
CIEH9 (550 CFM)
1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View)
Recommended Mounting Height*
Connection Diagram (36”- 54” Widths) Centerline of Hood
Centerline of Hood
¾”
5” x 16” Exhaust Opening
2 �⁄�”
9" 8" Round
8" Round
8” Transition Opening 9” Above Top of Hood
Electrical Vent Holes
9"
9" 5"
16"
550 CFM T200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(Included)
(Side View)
*Exceeding recommended mounting height may compromise performance.
Connection Diagram (60”- 66” Widths) 11”
11”
Centerline of Hood
5” x 16” Exhaust Opening (2)
¾”
Electrical (2) Vent Holes
9" 8" Round
8” Transition Opening (2) 9” Above Top of Hood
2 �⁄�”
8" Round
9"
9"
Centerline of Hood
5"
16"
1100 CFM T2+200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(2 Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
C
UL R
US
ISLAND RANGE HOOD SPECIFICATIONS CILH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Galley rail included. 14 ” ” 14 14
”
14
”
OPTIONAL DUCT COVER
2 OPTIONAL DUCT COVERS
4 ½”
4”
4 ½” 4 ½”
4 ½”
3”
4” 3”
5
¾”
”
20
”
0”
5¾
ths
2 id ”W 54
30
”
FM
0C
5¾
55
”
hs
& 8”,
4 2”,
-4
30
”
5¾
-6
idt ”W
66
”
1 ½” �⁄��” Dia. 1 ½” Island Duct Cover Mounting Holes (Top View)
CILH9 (550 CFM)
FM
0C
0 11
0” &
CILH9 (1100 CFM)
Recommended Mounting Height* Optional Duct Cover
Connection Diagram (42”- 54” Widths) Centerline of Hood
¾”
5” x 16” Exhaust Opening
2 �⁄�”
8" Round
8” Transition Opening 9” Above Top of Hood
Electrical Vent Holes
9"
8" Round
8’ Ceiling
Centerline of Hood
9”
9"
9" 5"
16"
550 CFM T200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(Included)
(Side View)
36”
*Exceeding recommended mounting height may compromise performance.
Connection Diagram (60”- 66” Widths) 11”
11”
Centerline of Hood
5” x 16” Exhaust Opening (2)
¾”
Electrical (2) Vent Holes
30”
8" Round
8” Transition Opening (2) 9” Above Top of Hood
2 �⁄�”
9"
8" Round
9"
9"
Centerline of Hood
5"
16"
1100 CFM T2+200 Dual Blower
VP565 Transition
Transition Installed
(Top View)
(2 Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0908A
C
UL R
US
ISLAND RANGE HOOD SPECIFICATIONS IZTH Equipped with halogen lighting. These models not available with heat lamps. Only available in stainless steel. Shown with optional duct cover (sold separately). Optional duct covers available in standard and custom sizes. Pot rail included. OPTIONAL DUCT COVER
OPTIONAL DUCT COVER
”
15
18
”
OPTIONAL DUCT COVER
”
22
15
”
”
”
54
”
42
14”
30
”
22
15
”
”
66
14”
30
”
OPTIONAL DUCT COVER
”
OPTIONAL DUCT COVER
”
15
18
”
15
”
”
22
�⁄��” Dia. 1 ½” IZDC Island Duct Cover Mounting Holes (Top View)
”
60
”
48 14”
30
14”
30
”
14”
30
”
Recommended Mounting Height*
Connection Diagram (42" - 48" Widths) 7"
Centerline of Hood
8" Round
8" Round
5” x 16” Exhaust Opening
Centerline of Hood
Optional Duct Cover
21"
9" 6 ¼” Electrical
8” Transition Opening 7” Above Top of Hood Vent Holes
5"
14”
16"
VP565 Transition
Transition Installed
(Top View)
(Included)
(Side View) 8’ Ceiling
550 CFM T200 Dual Blower
Connection Diagram (54" - 66" Widths)
30”
Centerline of Hood 10 ½”
9 ¼"
12" Round
12" Round
Vent Holes 8” Blower Outlets
36”
Centerline of Hood
23 ¼"
11 ¼" Electrical 6 ¼”
12” Transition Opening 9 ¼” Above Top of Hood
8" Round
8" Round
8" Round
1100 CFM T400 Cluster Blower
VP564 Transition
Transition Installed
(Top View)
(Included)
(Side View)
*Exceeding recommended mounting height may compromise performance. NOTE: DUCT COVER EXTENDS 2” INTO TOP OF HOOD.
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual T400 Island Cluster
Volts
Amps*
Hz
RPM
115 115
2.9 5.8
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431 1100 1800 998 855 774
Minimum Round Duct Size 8" (50 in.2) 12" (113 in.2)
Sones# 6.0 6.4
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808C
C
UL R
US
WALL MOUNT LINER SUBJECT TO CHANGE WITHOUT NOTICE
WALL MOUNT LINER INSERT SPECIFICATIONS KHSLD LINER Halogen lights only. This model not available with heat lamps. This model only available in Black, Biscuit, Gunsmoke Gray, Stainless Steel, or White. The VP521 transition is available for top vent applications at an additional charge.
16 ½
”
AN S TH IDTH S E 5” L TOM W BOT
7” 2½
”
6”
28
18”
34 3⁄8”,
3⁄8”,
7 ½”
8” 0 3⁄
4
KHSLD
”
10”
3¼
Top Vent or Back Vent 3 ¼” x 10”
Connection Diagrams (28 3/8", 34 3/8", & 40 3/8" Widths)
Wall Cutout for Vertical Ducting Viewed from Above
Recommended Mounting Height*
Wall Cutout for Horizontal Ducting Viewed from Front
Custom Enclosure
7⁄8" Top of Liner
2 5⁄8" Back of Liner
3 ½"
5"
5 1⁄8"
5 1⁄8"
5 1⁄8"
Electrical
7" CL
6 ¼" CL
8’ Ceiling
6”
21”-24”
36”
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model K250 (Top Vent) K250 (Back Vent)
Volts
Amps
Hz
RPM
115 115
3.2 3.2
60 60
1550 1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 250 375 223 220 190 220 330 215 195 180
Minimum Round Duct Size 7" (38 in.2) 7" (38 in.2)
Sones# 7.4 7.4
All K-Series hoods have two halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0909A
C
UL R
US
WALL MOUNT LINER INSERT SPECIFICATIONS BSLD/BHSLD LINER “H” in part number indicates halogen lighting. This model not available with heat lamps. 12”
N THA TH ESS ID 6” L TOM W T BO
3”
12” 6 ”, 4
19
28
¼”
3⁄8”,
34
3⁄8 40 3⁄8”,
3⁄8”
BSLD/BHSLD
Connection Diagram (28 3/8” - 40 3/8” Widths) 5 ¼”
Recommended Mounting Height*
1 ¾”
1 3⁄8”
Wall Side Custom Enclosure
Vent Hole Electrical 6” Outlet
3 ¼”
Centerline of Hood
12”
300 CFM B100 Single Blower 8’ Ceiling
(Top View)
Connection Diagram (28 3/8” - 46 3/8” Widths) 5 ½”
Wall Side
5 ¼” Vent Holes
1 ¾”
24”-27”
36”
8” Outlet
Electrical Centerline of Hood
600 CFM B200 Dual Blower
*Exceeding recommended mounting height may compromise performance.
(Top View)
Connection Diagram (46 3/8” Width) 7 5⁄16” Wall Side
10” Round
7 5⁄16”
5 ½”
10” OR 12” Round 10” Round
1 ¾”
1 7⁄8” Vent Holes
17 ½”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B100 Single B200 Dual B200 Dual & B100 Single
Volts
Amps*
Hz
RPM
115 115 115
1.5 2.9 4.4
60 60 60
1550 1550 1550
CFM CFM CFM Minimum Round • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 300 450 273 245 225 6" (28 in.2) 600 900 531 480 430 8" (50 in.2) 900 1350 804 725 655 VP562: 10" (79 in.2)
Sones# 5.4 6.5 6.3
* Add 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 48"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0609A
C
UL R
US
WALL MOUNT LINER INSERT SPECIFICATIONS BPSLD/BHPSLD LINER “H” in part number indicates halogen lighting. This model not available with heat lamps. 12”
N THA TH ESS ID 6” L TOM W T BO
3”
12”
22
�⁄�”, 40 ”, �⁄�”, , 58 �⁄� 4 ” 3 �⁄�”, 2 �⁄� 28 �⁄�”, 5 4 �⁄�” 6 46
½”
BPSLD/BHPSLD
Connection Diagram (28 3/8” - 52 3/8” Widths) 5 ½”
Wall Side
Recommended Mounting Height*
5 ¼” Vent Holes
1 ¾”
Custom Enclosure
8” Outlet
Electrical Centerline of Hood
12”
600 CFM B200 Dual Blower 8’ Ceiling
(Top View)
Connection Diagram (46 3/8” - 58 3/8” Widths) 7 �⁄��” 5 ½”
Wall Side
10” Round
7 �⁄��”
27”-30”
10” Round
1 ¾”
1 �⁄�” Vent Holes
17 ½”
36”
Electrical (2)
5 ¼” Centerline of Hood
8” Outlet
6” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blower (Top View)
VP562 Transition (Optional) For B300 (B200 Dual Blower & B100 Single Blower)
*Exceeding recommended mounting height may compromise performance. 10” OR 12” Round
Connection Diagram (52 3/8” - 64 3/8” Widths) 11”
11”
5 ½”
12” Round
5 ½”
Wall Side Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
12” Round
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 (Double B200 Dual Blowers)
VP562/VP563 transition centers outlet over top of hood
Electrical/Mechanical Specifications For Blower Units Model B200 Dual B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115 115
2.9 4.4 5.8
60 60 60
1550 1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 600 900 531 480 430 8" (50 in.2) 6.5 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 0.5 amp for each halogen light. Hoods are available with fluorescent light (one for each single or dual blower) or with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66"). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
WALL MOUNT LINER INSERT SPECIFICATIONS BH340PSLB/B446PSLB/BH446PSLB LINER “H” in model number designates halogen lighting. BH340PSLB is available with halogen lights only. This model not available with heat lamps. 12” �⁄�” 40 �⁄�” 46
3”
12”
Recommended Mounting Height* 22
Custom Enclosure
½”
BH340PSLB/B446PSLB/BH446PSLB
12”
Connection Diagram (40-3/8" Width) 5 ½”
Wall Side
10” Round
7 �⁄��”
10” Round
8’ Ceiling
7 �⁄��”
1 ¾”
1 �⁄�” Vent Holes
17 ½”
Electrical (2)
5 ¼”
6” Outlet
Centerline of Hood
8” Outlet
8” Round
8” Round
6” Round
2”
900 CFM B200 Dual & B100 Single Blowers (Top View)
36”
VP562 Transition (Optional) For B300 (B200 Dual & B100 Single Blowers) *Exceeding recommended mounting height may compromise performance.
Connection Diagram (46-3/8" Width) 11”
12” Round
11”
5 ½”
5 ½”
10” OR 12” Round
12” Round
Wall Side Vent Holes
1 ¾”
16 ½”
8” Outlet
5 ¼” 8” Outlet
27”-30”
Centerline of Hood
Electrical (2)
8” Round
8” Round
8” Round
3”
1200 CFM Double B200 Dual Blowers (Top View)
VP563 Transition (Optional) For B400 Transition centers outlet (Double B200 Dual Blowers) over top of hood
Electrical/Mechanical Specifications For Blower Units Model B200 Dual & B100 Single Two B200 Duals
Volts
Amps*
Hz
RPM
115 115
4.4 5.8
60 60
1550 1550
CFM CFM CFM Minimum Round • CFM Sones#
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" Duct Size 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6
* Add 0.5 amp for each halogen light. The B446PSLB is available with two fluorescent lights. Both models are available with three halogen lights. • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808A
C
UL R
US
ISLAND LINER SUBJECT TO CHANGE WITHOUT NOTICE
ISLAND LINER INSERT SPECIFICATIONS TSLE/THSLE “H” in part number indicates halogen lighting. This model not available with heat lamps. 15”
AN TH DTH S S LE WI 12” TOM T BO
3”
12”
”
48 2”, ”, 4
36
27”
TSLE/THSLE Connection Diagram (36” - 48” Widths)
Recommended Mounting Height*
Centerline Of Hood
Centerline Of Hood
2 �⁄�”
¾”
5” x 16” Exhaust Opening
Custom Enclosure
8” Transition Opening 9” Above Top of Hood
Electrical Vent Holes
12”
550 CFM T200 Dual Blower 8’ Ceiling
(Top View)
30”
9" 8" Round
8" Round 36”
9"
12" 5"
16"
VP565 Standard Transition
Transition Installed
(Included)
(Side View)
*Exceeding recommended mounting height may compromise performance.
Electrical/Mechanical Specifications For Blower Units Model T200 Island Dual
Volts
Amps*
Hz
RPM
115
2.9
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 550 900 507 471 431
Minimum Round Duct Size 8" (50 in.2)
Sones# 6.0
* Add 0.5 amp for each halogen light. Hood is available with fluorescent lights (one in front, one in back) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C
UL R
US
ISLAND LINER INSERT SPECIFICATIONS TPSLE/THPSLE “H” in part number indicates halogen lighting. This model not available with heat lamps. 22”
AN TH DTH S S LE WI 16” TOM T BO
3”
12”
”
6 ”, 6
, 48”
30”
, 60 54”
TPSLE/THPSLE Connection Diagram (48” - 66” Widths)
Recommended Mounting Height*
Centerline of Hood 1 ¾" Electrical (2)
Custom Enclosure
Vent Holes
8” Blower Outlets
Centerline of Hood
5 ½"
12”
12" Transition Opening 11 ¼" Above Top of Hood
8’ Ceiling
10 ½"
1100 CFM T400 Cluster Blower (Top View)
12" Round
12" Round
30”
11 1/4" 36”
11 ¼" 12"
8" Round
8" Round
*Exceeding recommended mounting height may compromise performance.
8" Round
VP564 Standard Transition
Transition Installed
(Included)
(Side View)
Electrical/Mechanical Specifications For Blower Units Model T400 Island Cluster
Volts
Amps*
Hz
RPM
115
5.8
60
1550
CFM CFM CFM • CFM
[email protected]" Equivalent CFM
[email protected]"
[email protected]"
[email protected]" 1100 1800 998 855 774
Minimum Round Duct Size 12" (13 in.2)
Sones# 6.4
* Add 0.5 amp for each halogen bulb. Hood is available with fluorescent lights (two for each dual blower) or with halogen lights (one in each corner). • Because the Magic Lung® blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”. # Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0808B
C