Preview only show first 10 pages with watermark. For full document please download

Vesta Series Corel Final Cut

   EMBED


Share

Transcript

Backing up your system in intelligent way V esta series is more than a traditional UPS. CPU controlled design, built-in AVR and smart communication interface, Vesta series not merely provides reliable power protection but also provide smart power management for increasing Internet and Ethernet applications. Vesta series is the most cost-effective solution to power-protection and power-managing your mission-critical PC, server, small network & valuable peripherals. Excellent Voltage Regulation Ability AC Line Surge Protection and Noise Filtering Every Vesta UPS with built-in- AVR protect the systems against voltage fluctuation. AVR will regulate the input voltage automatically within certain range without transferring to battery mode, which greatly extends the battery life. Full-time surge protection protects hardware from damaging by surge. EMI/RFI filtering protects the hardware from interfering by electrical noise. Smart Microprocessor Control UPS will perform self-test either by manual or automatic control. Periodical self-test can enhance the reliability and also ensure the battery quality before next black out. UPS Self-test Function Powerful microprocessor design integrates all power stages as well as control and communication functions that strongly enhance the functionality and reliability. Smart Battery Management Modem/LAN Internet protection Every Vesta UPS has equipped with RJ11/RJ45 surge suppression phone jack to protect against any spike or surge coming through network or telephone wires. Two stages Battery Low alarm will sound and shut down UPS automatically to prevent the battery from over-drain and extend the battery file. Site Wiring Fault Indicator Smart RS-232 interface for power management By connecting with UPS monitoring software, Vesta series supports real-time power & UPS status monitoring, automatic shutdown, schedule ON/OFF and many other advanced power management functions. For more functions about the software and its applicable O/S, please contact local distributors or manufacturer. DC Start Capability Detect and warn for abnormal wiring status to prevent potential hazard. Overload & Short Circuit protection Overload alarm will sound for warning the overload situation and shutdown UPS to prevent further damage. To prevent UPS and its protected devices, UPS will shutdown itself when senses short circuit situation. With high inrush handling ability, Vesta series can be turned on without connecting to the utility power. Users may turn ON/OFF the UPS freely during power failure. USB compatible USB compatibility and connectivity ensure quick and easy installation. It enhances automatically shutdown software and file saving. Power Abler & Excelsior Vesta Pro Series Technical Specification Model Input 525 625 Voltage(Vac) 1500i 115V / 230V -+ 25% Frequency(Hz) Output(AC mode) 1000i 50/60 -+ 5Hz auto-sensing AVR Regulation Increase output 15% (input -9~-25%) Decrease output 15% (input +9~+25%) 115V / 230V -+ 10% Voltage Output(INV. mode) 50/60 -+ 1% Frequency(Hz) Simulated Sine Wave Waveform Capacity(VA./W) 525 / 315 625 / 375 1000 / 600 5~30 mins for typical PC Load Autonomy Battery 1500 / 900 4ms Typical Transfer Time(ms) 12Vdc Voltage 24Vdc Sealed Maintenance Free Lead Acid VRLA type Type 12V / 7AH Capacity 12V / 7AH 1 pc Quantity 12V / 7AH 12V / 9AH 2 pcs 2pcs 1 pc 6~8 Hours to 90% Recharging Time DC Start Yes Self Diagnostics Upon Power-on and Software Control Site Wiring Fault Indicator Yes (115Vac system only) Yes Display 2 LEDS for Line/Backup and 4 LEDS for Line, Backup, Fault, and LEDS Battery Low / Fault Overload (AC Mode) (Inverter Mode) Overload Buzzer continuously alarms. Buzzer continuously alarms. >100% continuously alarms >100% continuously alarms >110% UPS shuts down after 10 sec. >110% UPS shuts down after 10 sec. Protection AC Mode: Input Fuse & Electronic Circuit INV. Mode: Electronic Circuit Short Circuit Noise Suppression Meets EN50091-2 Spike Suppression Meets EN61000-4-5 Two stages: Controlled Battery Low Warning & Cut off Battery Over-drain RJ45 Modem/Network Alarm Physical Line Failure, Battery Low, and Overload / Fault Audible Dimensions(WxHxD) 95 x 171 x 354 mm (3.7” x 6.7” x 13.9) 160 x220 x 370 mm (6.3”x 8.7” x 14.5” ) Net Weight 7.0Kgs/15.5 Ibs 13Kgs/28.6 Ibs 7.5Kgs/ 16.5 Ibs 16Kgs / 35.2 Ibs Outlets Line 0 + 2 NEMA5 - 15R 115V System 2 + 4 NEMA5 - 15R + Backup Environmental 0 + 2 IEC320 230V System 3 + 3 IEC320 0 - 40 degree C Operation Temperature 95% RH Maximum, Non-condensing Operation Humidity Computer Interface Type True RS232 Communication USB Communication (True RS232 Communication as an option) Interface Compatible platforms Safety Conformance Safety Standard Windows 95 / 98 / NT / 2000 / XP / Netware, Linux, FreeBSD, etc. EN50091-1 EMC / Surge Standard EN50091-2, EN61000-3-2, EN61000-3-3 Mark CE * Specification subject to change without prior notice. CALVINI VENTURES Hse No. C99/18 Osekan Street Abelenkpe Accra - Ghana P. O. Box NT 117 Accra Newtown Accra-Ghana Tel: +233-21-778-999 +233-20-200-3562 QUALIT ASSURED M FLA Y Fax: +233-21-778-999 ISO 9001 UKAS QUALITY MANAGEMENT http://www.calvini.com e-mail: [email protected] SG S 005