Transcript
Backing up your system in intelligent way
V
esta series is more than a traditional UPS. CPU controlled design, built-in AVR and smart communication interface, Vesta series not merely provides reliable power protection but also provide smart power management for increasing Internet and Ethernet applications. Vesta series is the most cost-effective solution to power-protection and power-managing your mission-critical PC, server, small network & valuable peripherals. Excellent Voltage Regulation Ability
AC Line Surge Protection and Noise Filtering
Every Vesta UPS with built-in- AVR protect the systems against voltage fluctuation. AVR will regulate the input voltage automatically within certain range without transferring to battery mode, which greatly extends the battery life.
Full-time surge protection protects hardware from damaging by surge. EMI/RFI filtering protects the hardware from interfering by electrical noise.
Smart Microprocessor Control
UPS will perform self-test either by manual or automatic control. Periodical self-test can enhance the reliability and also ensure the battery quality before next black out.
UPS Self-test Function Powerful microprocessor design integrates all power stages as well as control and communication functions that strongly enhance the functionality and reliability.
Smart Battery Management Modem/LAN Internet protection Every Vesta UPS has equipped with RJ11/RJ45 surge suppression phone jack to protect against any spike or surge coming through network or telephone wires.
Two stages Battery Low alarm will sound and shut down UPS automatically to prevent the battery from over-drain and extend the battery file.
Site Wiring Fault Indicator Smart RS-232 interface for power management By connecting with UPS monitoring software, Vesta series supports real-time power & UPS status monitoring, automatic shutdown, schedule ON/OFF and many other advanced power management functions. For more functions about the software and its applicable O/S, please contact local distributors or manufacturer.
DC Start Capability
Detect and warn for abnormal wiring status to prevent potential hazard.
Overload & Short Circuit protection Overload alarm will sound for warning the overload situation and shutdown UPS to prevent further damage. To prevent UPS and its protected devices, UPS will shutdown itself when senses short circuit situation.
With high inrush handling ability, Vesta series can be turned on without connecting to the utility power. Users may turn ON/OFF the UPS freely during power failure.
USB compatible USB compatibility and connectivity ensure quick and easy installation. It enhances automatically shutdown software and file saving.
Power Abler & Excelsior
Vesta Pro Series Technical Specification Model Input
525
625
Voltage(Vac)
1500i
115V / 230V -+ 25%
Frequency(Hz) Output(AC mode)
1000i
50/60 -+ 5Hz auto-sensing
AVR Regulation
Increase output 15% (input -9~-25%) Decrease output 15% (input +9~+25%) 115V / 230V -+ 10%
Voltage Output(INV. mode)
50/60 -+ 1%
Frequency(Hz)
Simulated Sine Wave
Waveform Capacity(VA./W)
525 / 315
625 / 375
1000 / 600
5~30 mins for typical PC Load
Autonomy Battery
1500 / 900
4ms Typical
Transfer Time(ms)
12Vdc
Voltage
24Vdc Sealed Maintenance Free Lead Acid VRLA type
Type 12V / 7AH
Capacity
12V / 7AH
1 pc
Quantity
12V / 7AH
12V / 9AH
2 pcs
2pcs
1 pc 6~8 Hours to 90%
Recharging Time DC Start
Yes
Self Diagnostics
Upon Power-on and Software Control
Site Wiring Fault Indicator
Yes (115Vac system only)
Yes
Display
2 LEDS for Line/Backup and
4 LEDS for Line, Backup, Fault, and
LEDS
Battery Low / Fault Overload (AC Mode) (Inverter Mode)
Overload
Buzzer continuously alarms.
Buzzer continuously alarms.
>100% continuously alarms
>100% continuously alarms
>110% UPS shuts down after 10 sec.
>110% UPS shuts down after 10 sec.
Protection AC Mode: Input Fuse & Electronic Circuit INV. Mode: Electronic Circuit
Short Circuit Noise Suppression
Meets EN50091-2
Spike Suppression
Meets EN61000-4-5 Two stages: Controlled Battery Low Warning & Cut off
Battery Over-drain
RJ45
Modem/Network Alarm
Physical
Line Failure, Battery Low, and Overload / Fault
Audible Dimensions(WxHxD)
95 x 171 x 354 mm (3.7” x 6.7” x 13.9)
160 x220 x 370 mm (6.3”x 8.7” x 14.5” )
Net Weight
7.0Kgs/15.5 Ibs
13Kgs/28.6 Ibs
7.5Kgs/ 16.5 Ibs
16Kgs / 35.2 Ibs
Outlets Line
0 + 2 NEMA5 - 15R
115V System
2 + 4 NEMA5 - 15R
+ Backup Environmental
0 + 2 IEC320
230V System
3 + 3 IEC320 0 - 40 degree C
Operation Temperature
95% RH Maximum, Non-condensing
Operation Humidity Computer
Interface Type
True RS232 Communication
USB Communication (True RS232 Communication as an option)
Interface
Compatible platforms
Safety Conformance
Safety Standard
Windows 95 / 98 / NT / 2000 / XP / Netware, Linux, FreeBSD, etc. EN50091-1
EMC / Surge Standard
EN50091-2, EN61000-3-2, EN61000-3-3
Mark
CE
* Specification subject to change without prior notice.
CALVINI VENTURES Hse No. C99/18 Osekan Street Abelenkpe Accra - Ghana P. O. Box NT 117 Accra Newtown Accra-Ghana Tel: +233-21-778-999 +233-20-200-3562 QUALIT