Preview only show first 10 pages with watermark. For full document please download

Vibrafoam 15 - Kraiburg Relastec

   EMBED


Share

Transcript

vibrafoam 15  Product Data Sheet Nr. 94700 ‐ R ‐ 01  Edition: November 2012          1. Application Sector   DAMTEC® vibrafoam 15 is a mat for the absorption of vibrations as well as for impact sound  insulation.  It  has  unique  compression  recovery  capability  and  has  exceptionally  resilient  characteristics.  The  ideal  area  of  application  is  for  a  static  material  pressing  up  to  0,010N/mm². The dynamic working range is up to 0.015N/mm²        2. Material  Mixed cellular polyether urethane.        3. Appearance  colour:        yellow  surface:        closed        4. Dimensions/Tolerances  width:         500 mm      length:        2000 mm      thickness /:      12.5 mm and 25 mm                              The data sheet is not subject to any change service! All information is without guarantee.   Latest version of this document available on www.kraiburg‐relastec.com/damtec   KRAIBURG Relastec GmbH & Co.KG  Fuchsberger Straße 4 ∙ D‐29410 Salzwedel  Fon +49‐(0) 86 83‐701‐1 42 ∙ Fax +49‐(0) 86 83‐701‐41 42  christina.wallner@kraiburg‐relastec.com ∙ www.kraiburg‐relastec.com/damtec                               1.5 %           1.5 %        1.0 mm  Seite 1 von 6 vibrafoam 15  Product Data Sheet Nr. 94700 ‐ R ‐ 01  Edition: November 2012          5. Physical Characteristics  tensile strength:  elongation at break:    tear resistance:    flammability rating:    loss factor:      static shear modulus:   dynamic shear modulus:  rebound elasticity:    compression set:    static load:      dynamic loads:    load peaks:            6. Installation:  > 0.35 N/mm²   > 300 %     > 0.6 N/mm    B2      approx. 0.25    approx. 0.03 N/mm²  approx. 0.08 N/mm²  50%   10 %   < 5%      < 0.010 N/mm²  < 0.015 N/mm²  < 0.500 N/mm²                                              (DIN 53455‐6‐4)          (DIN 53455‐6‐4)            (DIN ISO 34‐1)         (DIN 4102)          (in acc. to DIN 53513)          (in acc. to DIN 53513)          (in acc. to DIN 53513)      (DIN EN ISO 8307)      (DIN EN ISO 1856)  Installation is to be carried out in accordance with the DAMTEC® vibra installation instructions.                          DISCLAIMER:  The information provided is intended only as a summary and general overview on matters of interest. The information is  not intended to be comprehensive nor does it constitute expert advice. KRAIBURG RELASTEC shall not be liable for  incidental and/or consequential damages directly or indirectly sustained, nor any loss caused by not complying with  relevant industry/product standards and improper use of any Damtec® products. Due to varying construction methods, any  other circumstances not stated above should be brought to the attention of KRAIBURG RELASTEC for review. For suitability  to the prevailing site conditions, it is advised that certified testing should be conducted. It is recommended to seek further  advice on your application with our technical staff prior to use.      The data sheet is not subject to any change service! All information is without guarantee.   Latest version of this document available on www.kraiburg‐relastec.com/damtec   KRAIBURG Relastec GmbH & Co.KG  Fuchsberger Straße 4 ∙ D‐29410 Salzwedel  Fon +49‐(0) 86 83‐701‐1 42 ∙ Fax +49‐(0) 86 83‐701‐41 42  christina.wallner@kraiburg‐relastec.com ∙ www.kraiburg‐relastec.com/damtec    Seite 2 von 6 vibrafoam 15  Product Data Sheet Nr. 94700 ‐ R ‐ 01  Edition: November 2012          7. Spring characteristic  0,020 25mm  12,5mm 37,5mm  50mm  specific load [N/mm²] 0,015 0,010 0,005 0,000 0 2 4 6 8 10 12 deflection [mm]   rd (recording of 3  loading, at room temperature, v= 1% the thickness per second, shape factor q=3)        8. Static and dynamic modulus of elasticity  0,40 40 Hz elastic modulus [N/mm²] 0,35 0,30 10 Hz 0,25 5 Hz 0,20 0,15 0,10 static 0,05 0,00 0,000 0,005 0,010 0,015 0,020 specific load [N/mm²] (dynamic modulus: sinusoidal excitation with an oscillating range ±0,25 mm, static modulus: tangent modulus taken from the load  deflection curve, test according to DIN 53513, shape factor q=3)      The data sheet is not subject to any change service! All information is without guarantee. Latest version of this document available on www.kraiburg‐relastec.com/damtec   KRAIBURG Relastec GmbH & Co.KG  Fuchsberger Straße 4 ∙ D‐29410 Salzwedel  Fon +49‐(0) 86 83‐701‐1 42 ∙ Fax +49‐(0) 86 83‐701‐41 42  christina.wallner@kraiburg‐relastec.com ∙ www.kraiburg‐relastec.com/damtec      Seite 3 von 6 vibrafoam 15  Product Data Sheet Nr. 94700 ‐ R ‐ 01  Edition: November 2012          9. Natural frequency  0,020 50mm 37,5mm  25mm  12,5mm  specific load [N/mm²] 0,015 0,010 0,005 0,000 5 10 15 20 25 30 natural frequency [Hz]   Natural frequency of a single‐degree‐of‐freedom system consisting of a fixed mass and an elastic bearing based on a stiff subgrade, shape  factor 3        10. Vibration insulation  120 99%/‐40dB disturbing frequency [N/mm²] 110 98%/‐35dB 97%/‐30dB 94%/‐25dB 90%/‐20dB 100 90 82%/‐15dB 80 70 69%/‐10dB 60 50 0%/0dB 40 30 20 10 0 5 10 15 20 25 30 natural frequency [Hz]       The data sheet is not subject to any change service! All information is without guarantee. Latest version of this document available on www.kraiburg‐relastec.com/damtec   KRAIBURG Relastec GmbH & Co.KG  Fuchsberger Straße 4 ∙ D‐29410 Salzwedel  Fon +49‐(0) 86 83‐701‐1 42 ∙ Fax +49‐(0) 86 83‐701‐41 42  christina.wallner@kraiburg‐relastec.com ∙ www.kraiburg‐relastec.com/damtec      Seite 4 von 6 vibrafoam 15  Product Data Sheet Nr. 94700 ‐ R ‐ 01  Edition: November 2012          11. Shape factor  For a cuboid:  with:                    2 shape factor  length  width  thickness    Correction for varying shape factors  Reference value: shape factor q=3, specific load 0.01 N/mm²    4 3 0,0105 2 variation [%] specific load [N/mm²] 0,0110 0,0100 0,0095 1 0 ‐1 ‐2 ‐3 0,0090 ‐4 0 1 2 3 4 5 6 0 1 2 shape factor static load range      3 4 5 6 shape factor           deflection    4 6 2 2 variation [%] variation [%] 4 0 ‐2 ‐4 0 ‐2 ‐6 ‐8 ‐4 0 1 2 3 4 5 0 6 shape factor dynamic elasticity modulus at 10 Hz  2 3 4 5 6 shape factor         natural frequency          The data sheet is not subject to any change service! All information is without guarantee.   Latest version of this document available on www.kraiburg‐relastec.com/damtec   KRAIBURG Relastec GmbH & Co.KG  Fuchsberger Straße 4 ∙ D‐29410 Salzwedel  Fon +49‐(0) 86 83‐701‐1 42 ∙ Fax +49‐(0) 86 83‐701‐41 42  christina.wallner@kraiburg‐relastec.com ∙ www.kraiburg‐relastec.com/damtec    1   Seite 5 von 6 vibrafoam 15  Product Data Sheet Nr. 94700 ‐ R ‐ 01  Edition: November 2012          12. Temperature dependency  0,5 machanical loss factor dynamic E‐modulus [N/mm²] 1,0 0,8 0,6 0,4 10Hz 0,2 0,0 0,4 0,3 10Hz 0,2 0,1 0,0 ‐10 0 10 20 30 40 50 60 70 ‐10 temperature [°C] 0 10 20 30 40 50 60 70 temperature [°C] dynamischer E‐modulus within the linear area           mechanical loss within the linear area        13. Influence of the load duration  0,35 dynamic E‐modulus [N/mm²] relative deflection [% of thickness] 10³ h 60 0,02N/mm² 50 0,015N/mm²  40 30 20 0,01N/mm² 10 0,005N/mm²  1 E‐02 1 E‐01 1 E+00 1 E+01 1 E+02 1 E+03 1 E+04 1 E+05 1 E+06 period of loading [h] creep behavior      compressive stress, shape factor q=3                10 h 0,30 0,25 0,1 h 0,20 0,15 0,10 0,05 0,00 0,000 0 10⁵ h 0,005 0,010 0,015 0,020 specific load [N/mm²]           dynamic creep behavior    variation of the long term dynamic E‐modulus (10 Hz)    compressive stress, shape factor q=3        The data sheet is not subject to any change service! All information is without guarantee. Latest version of this document available on www.kraiburg‐relastec.com/damtec KRAIBURG Relastec GmbH & Co.KG  Fuchsberger Straße 4 ∙ D‐29410 Salzwedel  Fon +49‐(0) 86 83‐701‐1 42 ∙ Fax +49‐(0) 86 83‐701‐41 42  christina.wallner@kraiburg‐relastec.com ∙ www.kraiburg‐relastec.com/damtec    Seite 6 von 6