Preview only show first 10 pages with watermark. For full document please download

Vibration Converter

   EMBED


Share

Transcript

VI INDUSTRIAL NON-CONTACT DISPLACEMENT/ VIBRATION CONVERTER VI Series SPECIFICATIONS Page 1 of 2 Model Code / Additional Spec. Code( No entry if additional spec. code is not specified. ) • Sensor VS- VS- Sensor cable length 1 0.5m 2 1.0m Measured range 010 020 040 060 080 100 150 250 Directly connected type L0 to 1,000μm 0 to 2,000μm 0 to 4,000μm 0 to 6,000μm 0 to 8,000μm 0 to 10,000μm 0 to 15,000μm 0 to 25,000μm Connector type CMeasured range 040 060 080 100 150 250 0 to 4,000μm 0 to 6,000μm 0 to 8,000μm 0 to 10,000μm 0 to 15,000μm 0 to 25,000μm Sensor cable length 1 0.5m 2 1.0m 3 Without • Extension cable VW-100G- Except 25,000μm VW-100F- Cable length 1 2 3 4 Only for 25,000μm Connector type PTFE Cable length 2.5m 4.5m 2.0m 4.0m 1 2 3.0m 5.0m BNC(male) BNC(male) Note) *1 Input cable length = Sensor cable length + Extension cable length • Transmission box • Receiver VJII- B- Measured range 01 02 04 06 08 10 15 25 0 to 1,000μm 0 to 2,000μm 0 to 4,000μm 0 to 6,000μm 0 to 8,000μm 0 to 10,000μm 0 to 15,000μm 0 to 25,000μm Transmission cable length 1 100m or less 2 Over 100m SVW - /SLC Intrinsically safe VD- B- /SLC Non-intrinsically safe 0 to 1,000μm 0 to 2,000μm 0 to 4,000μm 0 to 6,000μm 0 to 8,000μm 0 to 10,000μm 0 to 15,000μm 0 to 25,000μm Transmission cable length 1 100m or less 2 Over 100m Silicon • Junction connector - Variation of cable 1 2 B- Measured range 01 02 04 06 08 10 15 25 • Transmission cable SVD- For 100m or less For over 100m VZ-1A Transmission cable length m numbers when Model VS-250C sensor is used, no junction connector is required. Interchangeability There is a possibility of performance degradation when any part of the combination of the sensor, the extension cable, the converter or the target is changed from what is specified in the test report. For more information, please refer to the instruction manual. 39618E2.1 Issued Apr.1997 Revised Sep. 2014 VI Series SPECIFICATIONS VI INDUSTRIAL NON-CONTACT DISPLACEMENT/ VIBRATION CONVERTER Page 2 of 2 SPECIFICATIONS • SVI Overall specifications Frequency response Displacement component : DC to 5kHz(-3dB) Vibration component : 5Hz to 10kHz(-3dB) Linearity Output voltage change by power voltage variation Within ±1.0% of F.S. 10% variation : Within 0.5% of F.S. • VJII Transmission box Transmission method Input Amplitude modulation Combined with sensor Carrier frequency Operating temperature range 800kHz to 4.3MHz -10 to +50°C (14 to 122°F REF.) Case Color Aluminum die-cast Munsell 7.5BG4/1.5 Weight Approx. 1.8kg • VS Sensor Measured distance 0 to 1,000μm - 25,000μm by measured range of Model Code No. Target All conductor -10 to +130°C (14 to 266°F REF.) Operating temperature range Target material Sensor cable (high-frequency coaxial cable) Sensor tip Threaded Jam nut Diameter : Length : : Ceramic : SUS304 : SUS304 ø2mm (except sensor for 25,000μm) 0.5m or 1.0m • SVD Receiver Input signal Amplitude modulation signal Signal supplied to sensor High-frequency current Peak value rectification method Vibration component computation Displacement output ×2, ×5, ×10 jumper selection (shipped at ×10 unless specified) 0 to 5VDC Frequency range Load current DC to 5kHz(-3dB) 5mA max. Output impedance Within 1kΩ 1 to 5VDC(impedance : 250Ω) 4 to 20mADC(load resistance : within 500Ω) Amplitude conversion gain Vibration output Frequency range Linear rise form 5Hz to 10kHz(-3dB) 10 points break form Output abnormal alarm Contact output 1 transfer, dry contact Alarm output Alarm contact capacity Operating temperature range AC/DC 24V 0.1ADC (load resistance) 0 to 50°C (32 to 122°F REF.) Power supply Max. power consumption 100VAC±10% 20VA Case Color Copper plate and aluminum Munsell N7 Weight 4.8kg 50/60Hz 39618E2.1 Issued Apr.1997 Revised Sep. 2014