Preview only show first 10 pages with watermark. For full document please download

Victoria 12,000 Btuh

   EMBED


Share

Transcript

VICTORIA Series Powered by Submittal Data: GWH12QC-D3DNA1D Job Name Purchaser Submitted To Unit Designation 12,000 BTU/H Wall Mounted Heat- Pump System Location Engineer Reference For Schedule No. Date Approval Construction GENERAL FEATURES -Compact and Quiet Design -High Efficiency - 16 SEER -DC Inverter Technology -Wireless Remote with LCD Display -Low Ambient Cooling -Comfortable Sleep Mode -Intelligent Defrost -5 year Limited Parts Warranty Indoor Unit Data System Ratings Fan Motor Cooling Rated Capacity Capacity Range Power Input (Max) SEER EER Heating at 47° F Rated Capacity Capacity Range Power Input (Max) HSPF COP Heating at 17° F Rated Capacity Capacity (Max) Power Input (Max) COP Operating Range Cooling Heating 12,000 BTU/H 3,100-13,000 BTU/H 1,080 W 22 13.0 (Max) (Min) (Max) (Min) Power S upply Normal Operational Voltage Voltage Range Main Power Wire Size Interconnecting Cable Wire Size MCA MOCP/Breaker Size Output Power F LA 20 W 0.2 A Airflow 171/400 CFM Cooling Wet (Lo/Hi) 171/400 CFM Heating Dry (Lo/Hi) S ound Pres s ure L evel 29/45 db(A) Cooling (Lo/Hi) 13,000 BTU/H 29/45 db(A) Heating (Lo/Hi) 2,400-14,000 BTU/H 1,360 W Dimensions & Weights 33.3 x 11.1 x 8.2-in Unit Dimensions (LxHxD) 10.1 22/27 LBS Weight (Net/Shipping) 11.8 Outdoor Unit Data 7,600 BTU/H Compressor DC Inverter Driven Rotary 11,167 BTU/H Refrigerant Type R410A 1,168 W Fan Motor Output Power 30 W 8.1 F LA 0.2 A Sound Pressure Cooling 54 db(A) 115℉ (48 C) Heating 54 db(A) 0℉ (-18 C) Dimensions & Weights 75℉ (24 C) Unit Dimensions (LxHxD) 33.4 x 23.6 x 12.6-in -4℉ (-20 C) Weight (Net/Shipping) 86/93 LBS R efrigerant Piping Data 3/8-in Gas Pipe Size (OD) 208/230 V, 1 Phase, 60 Hz 1/4-in Liquid Pipe Size (OD) 187 - 253 V Flared Connection Method 14-2 AWG 66-ft M A X R e f r i g e r a n t P i p e L e n g t h 14-4 AWG 10.0 A 10-ft MIN Refrigerant Pipe Length 15 A 33-ft MAX Refrigerant Pipe Height Difference © C&H Corporation 2015 VICTORIA Series Powered by Submittal Data: GWH12QC-D3DNA1D 12,000 BTU/H Wall Mounted Heat- Pump System EXTENDED RATINGS COOLING PERFORMANCE Outdoor Ambient Temperature (DB) Indoor Entering Air Temperatures (DB) 50% RH TC 62 F SHC TC 67 F SHC TC 72 F SHC 25 F 14,898 11,045 16,102 11,631 17,181 12,381 55 F 13,326 10,288 14,201 10,647 15,221 11,127 35 F 45 F 65 F 75 F 85 F 95 F 105 F 115 F 14,566 13,840 12,869 12,368 11,884 11,267 10,646 10,024 11,026 10,625 9,995 9,651 9,398 9,006 8,644 8,297 15,466 14,800 14,175 13,329 12,737 12,125 11,483 10,663 11,295 10,969 10,736 10,230 9,838 9,650 9,134 8,636 16,250 15,856 15,023 14,314 13,782 13,225 12,448 11,372 11,726 11,477 10,986 10,564 10,334 9,932 9,564 8,879 HEATING PERFORMANCE Outdoor Ambient Temperature (DB) (80% RH) 5F 15 F 25 F 35 F 45 F 55 F 65 F TC- Total Capacity ( BtuH) SHC- Sensible Capacity (BtuH) Indoor Entering Air Temperatures (DB) 65 F 70 F 75 F TC SHC TC SHC TC 9,267 9,267 8,706 8,706 8,478 11,656 11,656 11,023 11,023 10,672 11,904 11,904 11,741 11,741 11,533 12,940 12,940 12,705 12,705 12,598 14,266 14,266 14,059 14,059 13,614 14,586 14,586 14,316 14,316 14,199 14,531 14,531 14,447 14,447 14,345 © C&H Corporation 2015 SHC 8,478 10,672 11,533 12,598 13,614 14,199 14,345 VICTORIA Series Powered by Submittal Data: GWH12QC-D3DNA1D 12,000 BTU/H Wall Mounted Heat- Pump System MINIMUM SPACING REQUIREMENTS Units: inch (mm) Units: inch (mm) © C&H Corporation 2015 DIMENSIONAL SPECIFICATIONS INDOOR UNIT DIMENSIONS GWH12QC-D3DNA1D Units: inch (mm) 8.2 (208) 33.3 (846) Liquid Line Valve Gas Line Valve Drain Connector OUTDOOR UNIT DIMENSIONS 1/4-in OD Flared 3/8-in OD Flared 5/8-in OD Units: inch (mm) 23.6 (600) Liquid Line Valve Gas Line Valve 1/4-in OD Flared 3/8-in OD Flared www.cooperandhunter.us without notice or without incurring obligations. All rights reserved. © C&H Corporation 2015